Voltage and Frequency Dependency

Similar documents
ECE 422/522 Power System Operations & Planning/Power Systems Analysis II 5 - Reactive Power and Voltage Control

LIMITS FOR TEMPORARY OVERVOLTAGES IN ENGLAND AND WALES NETWORK

Fault Ride Through Technical Assessment Report Template

TS RES - OUTSTANDING ISSUES

System Operability Framework 2014

Transient Recovery Voltage (TRV) and Rate of Rise of Recovery Voltage (RRRV) of Line Circuit Breakers in Over Compensated Transmission Lines

EH2741 Communication and Control in Electric Power Systems Lecture 2

each time the Frequency is above 51Hz. Continuous operation is required

Level 6 Graduate Diploma in Engineering Electrical Energy Systems

SYNCHRONISING AND VOLTAGE SELECTION

RfG Implementation Fault Ride Through

ESB National Grid Transmission Planning Criteria

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Wind Aggregated Generating Facilities Technical Requirements

Wind Power Facility Technical Requirements CHANGE HISTORY

ECE 692 Advanced Topics on Power System Stability 5 - Voltage Stability

Highgate Converter Overview. Prepared by Joshua Burroughs & Jeff Carrara IEEE PES

SRI VIDYA COLLEGE OF ENGG AND TECH

Facilitating Bulk Wind Power Integration Using LCC HVDC

Background on Fast Fault Current Injection

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements

Volume I Issue VI 2012 September-2012 ISSN

Chapter -3 ANALYSIS OF HVDC SYSTEM MODEL. Basically the HVDC transmission consists in the basic case of two

Impact of Distributed Generation on Network Voltage Levels

Designing Of Distributed Power-Flow Controller

ELEMENTS OF FACTS CONTROLLERS

CHAPTER 4 POWER QUALITY AND VAR COMPENSATION IN DISTRIBUTION SYSTEMS

Chapter 10: Compensation of Power Transmission Systems

Influence of Wind Generators in Voltage Dips

Joe Warner, Electric Power Industry Conference (EPIC), November 15, 2016 Advances in Grid Equipment Transmission Shunt Compensation

Improvement of Power Quality Considering Voltage Stability in Grid Connected System by FACTS Devices

Analysis of a 405 km transmission line with series compensation

Calculating and compensating for power transformer and cable (or line) losses - standard methods

ITC Holdings Planning Criteria Below 100 kv. Category: Planning. Eff. Date/Rev. # 12/09/

COMPARATIVE PERFORMANCE OF SMART WIRES SMARTVALVE WITH EHV SERIES CAPACITOR: IMPLICATIONS FOR SUB-SYNCHRONOUS RESONANCE (SSR)

Loss of Mains Protection

Electrical Power Systems

GENERATOR INTERCONNECTION APPLICATION Category 5 For All Projects with Aggregate Generator Output of More Than 2 MW

Power Quality and the Need for Compensation

FNN comments on NC HVDC submitted to ENTSO E

SELECTING NATIONAL MW BOUNDARIES

Appendix S: PROTECTION ALTERNATIVES FOR VARIOUS GENERATOR CONFIGURATIONS

Although shunt capacitors

MINISTERIE VAN ECONOMISCHE ZAKEN GENERAL COST COMPARISON BETWEEN UNDERGROUND CABLES AND O.H. LINE SYSTEMS FOR H.V. TRANSMISSION

RELEVANT ELECTRICAL STANDARDS

Address for Correspondence

Intermittent Renewable Resources (Wind and PV) Distribution Connection Code (DCC) At Medium Voltage (MV)

Determination of Optimal Account and Location of Series Compensation and SVS for an AC Transmission System

Endorsed Assignments from ERS Framework

Application of Distribution Static Synchronous Compensator in Electrical Distribution System

SYSTEM MONITORING FAULT RECORDING

Available online at ScienceDirect. Energy Procedia 53 (2014 ) 86 94

WFPS1 WIND FARM POWER STATION GRID CODE PROVISIONS

Long lasting transients in power filter circuits

Wind Power Plants and future Power System Frequency Stability

Assessment of Saturable Reactor Replacement Options

Introduce system protection relays like underfrequency relays, rate of change of frequency relays, reverse - power flow

Power System Oscillations Damping and Transient Stability Enhancement with Application of SSSC FACTS Devices

Power electronic converters in power systems. SINTEF Energy Research

STATCOM WITH POD CONTROLLER FOR REACTIVE POWER COMPENSATION Vijai Jairaj 1, Vishnu.J 2 and Sreenath.N.R 3

National Grid s commitments when undertaking works in the UK. Our stakeholder, community and amenity policy

Electrical Engineering. Power Systems. Comprehensive Theory with Solved Examples and Practice Questions. Publications

Table of Contents. Introduction... 1

Distance Protection of Cross-Bonded Transmission Cable-Systems

Generation Interconnection Requirements at Voltages 34.5 kv and Below

Power Quality enhancement of a distribution line with DSTATCOM

Comparative Analysis of Multiple-pulse VSC-Based STATCOM s for Voltage-Dip Mitigation

Dynamic Series Compensation for the Reinforcement of Network Connections with High Wind Penetration

EUROPEAN COMPLIANCE PROCESSES (post RfG Implementation) CONTENTS. (This contents page does not form part of the Grid Code) Paragraph No/Title

Grid codes and wind farm interconnections CNY Engineering Expo. Syracuse, NY November 13, 2017

MARKET ANCILLARY SERVICE SPECIFICATION

Performance Analysis of Passive Filter for Harmonics Due to Non-Linear Load in Power System

Digital Fault Recorder Deployment at HVDC Converter Stations

Static Synchronous Compensator (STATCOM) for the improvement of the Electrical System performance with Non Linear load 1

IEEE Major Revision of Interconnection Standard

GENERATOR INTERCONNECTION APPLICATION Category 3 For All Projects with Aggregate Generator Output of More Than 150 kw but Less Than or Equal to 550 kw

Parameters related to voltage issues

IEEE sion/1547revision_index.html

CPC1590 Application Technical Information

Design Strategy for Optimum Rating Selection of Interline D-STATCOM

ENTSO-E Draft Network Code on High Voltage Direct Current Connections and DCconnected

Fundamental Concepts of Dynamic Reactive Compensation. Outline

p. 1 p. 6 p. 22 p. 46 p. 58

Interline Power Flow Controller: Review Paper

Project acronym: Multi-island

Filter Considerations for the IBC

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

APPLICATION OF INVERTER BASED SHUNT DEVICE FOR VOLTAGE SAG MITIGATION DUE TO STARTING OF AN INDUCTION MOTOR LOAD

Microgrid Protection

EUROPEAN COMPLIANCE PROCESSES (post RfG Implementation) CONTENTS. (This contents page does not form part of the Grid Code) Paragraph No/Title

Network Code for HVDC Connections and DC-connected Power Park Modules Requirement Outlines

Electricity Ten Year Statement November Electricity Ten Year Statement November Appendix D

EE 340L EXPERIMENT # 5.1 SYNCHRONOUS GENERATOR (STAND-ALONE OPERATION)

International Journal of Emerging Technology in Computer Science & Electronics (IJETCSE) ISSN: Volume 8 Issue 1 APRIL 2014.

Transient stability improvement by using shunt FACT device (STATCOM) with Reference Voltage Compensation (RVC) control scheme

Comparison of the Behaviour of Wind Farms and Conventional Power Stations during Grid Failure Conditions

Is Now Part of To learn more about ON Semiconductor, please visit our website at

APPLICATION FOR INTERCONNECTION & OPERATIONS OF MEMBER-OWNED GENERATION

This document is a preview generated by EVS

Fuel cell power system connection. Dynamics and Control of Distributed Power Systems. DC storage. DC/DC boost converter (1)

Mitigation of Voltage Sag and Swell using D-STATCOM to improve Power Quality

Transcription:

Average hourly generation (GW) System Operability Framework Voltage and Frequency Dependency The demand and generation we see on the electricity network has been changing in recent years and is set to continue to change into the future. One of the affects of this change is how frequency and voltage disturbances interact with each other. They will interact more in the future, driving a dynamic voltage requirement. Executive Summary Frequency and voltage are usually considered and assessed independently in the design and operation of electrical networks. However, they are intrinsically linked. This investigation seeks to understand this relationship, how it is changing over time and how it may behave in different regions of Great Britain (GB). All faults on our system, such as a line or generator tripping, will have a combined frequency and voltage effect. In the future, with the reduction in synchronous generation, combined events will be more significant and will need to be considered. Each area studied in this assessment has a unique set of results. This shows different regions of Great Britain can display different behaviours based on the local network and generation mix. As the generation mix in each region changes in the future, so will the combined frequency and voltage effect change. Figure 1 summarises the decline in synchronous generation likely to be seen in the next 10 years, according to current trends. Our Future Energy Scenarios (FES)[1] details this further. This study has found that to support frequency and voltage recovery, additional dynamic voltage support will be required to replace that which is currently provided by synchronous generation. Distributed energy recourses (DER) could also provide this in the future, in addition to other technologies. National Grid has recently published a road map for Network Options Assessment (NOA)[2] and Product Roadmap for Reactive Power[3] laying out a path to include more operability issues in it s considerations. We are currently considering various alternatives for dynamic voltage support as part of this process. 30 28 26 24 22 20 18 16 14 12 10 Average Synchronous Generation per hour - across 10 years 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 Year We hope that you find this document, along with our other system operator publications, useful as a catalyst for wider debate. For more information please contact us: sof@nationalgrid.com Consumer Power Slow Progression Steady State Two Degrees

System Operability Framework 2 Voltage and Frequency June 2018 Background When a generator trips off the system, the frequency drops as the demand is no longer being met. This event disturbs the voltage as the power flow across the transmission system changes. Figure 3 shows what happens when a fault occurs, before protection has operated to clear the fault. If there is an overhead line fault there will be a voltage disturbance. This change in voltage will affect the power flow and can create a frequency disturbance. F mu gq pcaargt c nmu cp pcosgpck cl r addcarcb b w flmu af al ec? When the power flow is low, the transmission line/cable is capacitive, generating extra reactive power and lifting the voltage level. This needs the System Operator to facilitate absorption of the extra reactive power, e.g. switching on a shunt reactor. When the power flow is high, the transmission line/cable becomes inductive, absorbing reactive power from the network and reducing the voltage level. This requires the System Operator to facilitate generation of reactive power, such as switching on a capacitor bank. Each region of the country is unique with different transmission lines, generation and voltage support. This will also affect how the frequency and voltage recover regionally. Figures 2 through 5 show an example of a combined frequency and voltage event. At the fault location, the voltage will reduce to zero. This will affect each generation and demand type differently. The result will be a lower export from the region, which is represented by a smaller arrow, indicating the flow. Synchronous generation will provide more fault current and reactive power than non-synchronous generation. This situation will last for no longer than 140ms before protection operates to remove the fault from the system. Immediately following action of protection Figure 4 shows that the fault has been cleared from the system by disconnecting the affected transmission lines and the generator. The voltage will now start to recover, with fewer Figure 2 shows an example transmission network where the generation in the example region is higher than the demand so the area is exporting across four circuits. This is described as the steady state. transmission lines and less generation. This will affect each generation and demand type differently. The result will be an increased export from the region compared to before the fault was cleared, which can be seen in Figure 4. The overall export from the region is less than before the fault happened due to the loss of generation. Electrical fault occurs The flow on the remaining two lines will be higher than

System Operability Framework 3 Voltage and Frequency June 2018 before the fault. This loading on the line will lead to a further decline in voltage. The rate at which the frequency is falling will start to slow as power out of the area begins to increase. The frequency will continue to fall due to the overall loss of generation. Ongoing voltage and frequency recovery Figure 5 shows the interaction between frequency and voltage recovery after the fault. As the voltage declines, with the increasing loading on Example Region Generator Disconnected by fault Wider GB transmission network area 3 has the highest proportion of synchronous generation. For each of these areas, a series of studies have been run to look at how the frequency and voltage are interacting following a fault. Figure 6 shows the results for area 2 in 2020. For this study the fault is a loss of a transmission line and a generator tripping off which is shown at the red line. Following the loss of generation, the frequency falls, due to the imbalance in generation and demand, and the voltage falls due to a reduced number of circuits out of the area. At the same time the amount of power out of the area also reduces and the rate of change of frequency is high. Substation B Substation A Substation C At the blue dotted line, you can see the voltage recovering. This helps to increase the amount of power coming out of the area which in turns helps to stop the frequency falling. Fault cleared the lines, the power out of the area declines. This in turn affects the frequency causing it to decline. As the power out of the area declines, the voltage to starts to recover again. As the voltage increases so does the power out of the area and frequency then increases. This oscillation of power, voltage and frequency can last for several seconds. During this time frequency response will start to act to recover the frequency. To help reduce the impact of this combined effect dynamic voltage support can be used. This will help to recover and maintain the voltage which in turn will support the recovery of frequency. Assessment Oscillating post fault flow on remaining routes Three case studies, that represent different types of region found in Great Britain have been considered: area 1 has the highest proportion of distribution connected non synchronous generation area 2 has the highest transmission connected non synchronous generation The power out of the area is now using fewer transmission circuits, as the power increases the impedance of the circuits increase and drives the voltage down again, seen at the green dotted line. This has the effect of decreasing the power out of the area and the frequency falls again and there is a corresponding rate of change of frequency event. This effect can be seen again with a further voltage dip. From 2 seconds onwards, frequency response is having an effect and the frequency and the voltage recover to pre-fault conditions. The final part of the study looked at how quickly the frequency returned to pre-fault levels with different amounts of dynamic voltage support. This dynamic voltage support is coming from distributed energy resources (DER). The light blue line shows the recovery with no support from DER and the purple line shows the recovery with DER support. If DER dynamic voltage support is available it will help recover the frequency quicker and support the recovery of the power export out of the area. Currently frequency and voltage events are considered separately and not combined as we have done through this study. Moving forwards, with a decline in synchronous generation, a combined event will become more significant and will need to be considered. Figure 7, shows the results for all three areas studied. In areas 1 and 2, where there is a higher penetration of non-synchronous generation, there is an increasing

System Operability Framework 4 Voltage and Frequency June 2018 mix in each region directly relates to the size of this effect. Synchronous generation provides more dynamic voltage support than non synchronous generation does. This means to continue facilitating non synchronous connection, additional dynamic voltage support will be required. The amount of dynamic voltage support needed will vary between regions. Variable 2017 2020 2025 Area 1 Positive Negative Area 2 Positive Negative Area 3 Positive Positive Negative Negative Positive across SP and SS. Negative across TD and CP. Area 1 highest proportion of distribution connected non synchronous generation. Area 2 highest transmission connected non synchronous generation. Area 3 highest proportion of synchronous generation. Conclusion All faults on our system will have a combined frequency and voltage event. In the future, with the reduction in synchronous generation, combined events will be more significant and will need to be considered. To support frequency recovery additional dynamic voltage support will be required to replace that currently provided by synchronous generation. Distributed energy recourses could provide this in the future, in addition to other technologies. need to consider combined frequency and voltage events and this combined effect will drive a dynamic voltage requirement. In area 3, where synchronous generation remains dominant, the combined event drives little value. Therefore, the additional dynamic voltage requirement will be lower. These results show us that the network and generation Each area studied had a unique set of results. This shows how each region of Great Britain will display different behaviour based on local network and generation mix. As the generation mix in each region changes in the future, so will the combined frequency and voltage effect change in each area. National Grid has recently published a road map for

System Operability Framework 5 Voltage and Frequency June 2018 Network Options Assessment (NOA)[2] and a Product Roadmap for Reactive Power laying out a path to include more operability issues in this process. This effect, along with other operability challenges will be investigated this year to understand the suitability of being included in this process. Look out later in the year for further updates. We hope that you find this document, along with our other system operator publications, useful as a catalyst for wider debate. For more information please contact us: sof@nationalgrid.com Glossary Protection - a device which tells circuits where faults are located so they can be isolated from the rest of the system using circuit breakers. Synchronous generation - a machine that generates an alternating voltage coupled to the system with the ability to provide immediate fault level and inertia, without the need to measure the grid system. Non-synchronous generation - generation technologies which are de-coupled from the grid via a converter or control system and do not contribute to system inertia. Their ability to provide support to the grid system is dependant on having the time to measure the system accurately and being able to respond appropriately. Fault current (Short Circuit Level) - when there s a short circuit, there s a flow of current towards the ground which must be isolated from the system as soon as possible. The size of this fault current is determined by the size of the generation producing a voltage, which is coupled with the system and how far away this generation is electrically (this being the impedance of the grid system). Fault level is a good indicator of system strength. generators which can do both. Frequency response - the power response of the power system (or a section of the power system) to a frequency deviation; they can be dynamic (continuous and proportionate) or non-dynamic (discrete) responses. Dynamic voltage support - devices that can modify their behaviour according to voltage level and provide variable reactive power, in various time scales. Typical devices that can do this immediately, without the need for measurement, include synchronous generators and synchronous compensators. These immediate forms of support are important during a short circuit fault and in the immediate period after the fault has been cleared (0-80 milliseconds). Non-synchronous generators, static compensators and static var compensators can all further assess after that immediate period provided the are controlled carefully to support voltage recovery. Sufficient dynamic voltage support is critical to contain and recover the voltage following a disturbance, as well as to manage changes in the reactive power demand in real-time. Impedance - the total opposition to the current flow in an electrical circuit. The Impedance includes the resistance (this often being referred to as transmission losses) and the reactance (magnetic losses that can reduce voltage). References 1. Future Energy Scenarios (FES) - http:// fes.nationalgrid.com/fes-document/ 2. Network options assessment https:// www.nationalgrid.com/uk/publications/network-optionsassessment-noa 3. Product Roadmap for Reactive Power https:// www.nationalgrid.com/uk/electricity/balancing-services/ future-balancing-services Reactive power - In order to transmit active power across the grid system, it is necessary for the system to have a set of voltages which support the power transfer. These sets of voltages have to be controlled within time limits in order for the power to be supplied securely and efficiently. Voltage is increased by supplying reactive power to the grid system and is decreased by absorbing reactive power from the grid system. Devices that store energy through a magnetic field produced by a flow of current are said to absorb reactive power; those that store energy through electric fields are said to generate reactive power. There are some devices e.g.

System Operability Framework 6 July 2017 Disclaimer The information contained within the System Operability Framework document ( the Document ) is disclosed voluntarily and without charge. The Document replaces the System Operation section of the Electricity Ten Year Statement (ETYS) and is published in accordance with the relevant Licence conditions. National Grid would wish to emphasise that the information must be considered as illustrative only and no warranty can be or is made as to the accuracy and completeness of the information contained within this Document. Neither National Grid Electricity Transmission, National Grid Gas nor the other companies within the National Grid group, nor the directors, nor the employees of any such company shall be under any liability for any error or misstatement or opinion on which the recipient of this Document relies or seeks to rely other than fraudulent misstatement or fraudulent misrepresentation and does not accept any responsibility for any use which is made of the information or Document which or (to the extent permitted by law) for any damages or losses incurred. Copyright National Grid 2016, all rights reserved. No part of this Document or this site may be reproduced in any material form (including photocopying and restoring in any medium or electronic means and whether or not transiently or incidentally) without the written permission of National Grid except in accordance with the provisions of the Copyright, Designs and Patents Act 1988. Continuing the conversation Join our mailing list to receive email updates for SOF or any of our Future of Energy documents: nationalgrid.com/updates Email us with your views on the System Operability Framework: sof@nationalgrid.com Access our current and past SOF documents and data: nationalgrid.com/sof Keep up to date on key issues relating to National Grid at our Connecting website: nationalgridconnecting.com