SENEL TECHNOLOGIES S.A. Load Cells Electronic Indicators

Similar documents
Type PB Load Cell. Approvals OIML approval to C3 (Y = 7 500; Y = for 375 kg capacity)

Bestech Australia U14/44 Garden Blvd, Tel: Dingley VIC 3172 Fax:

Bestech Australia U14/44 Garden Blvd, Tel: Dinely VIC 3172 Fax:

Single point load cell

A shear beam load cell, with strain gauges, tested as a part of a weighing instrument. Manufacturer : Precia Molen Type : CSI.

Single point load cell

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS2000S Hermetically sealed bending beam load cell

Bestech Australia U14/44 Garden Blvd, Tel: Dingley VIC 3172 Fax:

Force and weight measuring instruments

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features

MAGTROL. LMU Series Load Monitoring Units. LMU Data Sheet. Description. Features

MAGTROL. LMU 116 Load Monitoring Unit. LMU 116 Data Sheet FEATURES DESCRIPTION SYSTEM CONFIGURATION

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features

Load Cells Page Option Option

Load Cells Page Option Option

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

MAGTROL. LMU 112 and LMU 117 Load Monitoring Units. LMU 112 / LMU 117 Data Sheet LMU 112 FEATURES LMU 117 FEATURES DESCRIPTION SYSTEM CONFIGURATION

TORKEL 900-series Battery Load Unit

PW6C. Single point load cells. Special features. Data sheet

100/200/400 t. Self-centering pendulum lead cells. Data sheet. Special features

Analog Digital Multimeter with Insulation Resistance Measurement

RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement

TORKEL 900-series Battery Load Unit

Additel 875 Series Dry Well Calibrators

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

MODEL AT-10 ANALOG TRANSMITTER

Economical Digital Indicators For Process and Electrical Measurement

Model LBS Miniature Compression Load Button

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier

Conductivity Analyzer

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

Digital Fluid Damped Single Point Load Cell

Model 3A Series 3-Axis Load Cell

Weighing Instruments

Force and weight measuring instruments

Current Clamp. 210

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Contents. Measurement and checking equipment for transformation centers Micro-ohmmeter MH-10 Page 3. Indirect earth contact simulator TL-5 Page 5

Model 1140A Thermocouple Simulator-Calibrator

Temperature Measurement

C.A 6115N. Safety at all costs. IEE 16th: Electrical installation IEC/EN I E C. Insulation RCD. Earth. Loop. Continuity.

SUBJECT TO CHANGE WITHOUT NOTICE

DN 16 ISO-KF. Dimensional drawings THERMOVAC TM 101 (mm)

Protection components

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

CALYS Transportable documenting multifunction calibrator with high accuracy 0.01%

SonoMeter 31 Energy Meters

Power Meter Series PM3200 Functions and characteristics

02/11/2015

RS /M MZ SERIES

INDEX. Micro-ohmmeter MH-10 Page 3. MI (5, 10, 15, 20 kv) Page 4 Mega-ohmmeter MD (5 kv) Page 4

1- Description CONTENTS

Model 3A Series 3-Axis Load Cell

02/11/2015

Additel 875 Series Dry Well Calibrators

Target disk flowmeter for liquids and gases

Load cell. Special features. Data sheet

E Series 9.00 (1/2) E series

02/11/2015

SITRANS T measuring instruments for temperature

CAN-IO Custom IO remote module

Ron 2000 Shackle Type Dynamometer with Remote Indicator

DG5000 series Waveform Generators

Installation and Operating Manual

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

ISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits

P5201 Universal Programmable Transmitters with Galvanic Isolation

SLW-Tri Series Sanitary Hygienic Liquid Turbine Flow Meter

AHU. Specifications. Materials. Ordering Information E UL Approved Illuminated Pushbutton. page 1

Temperature Measurement

High Performance Process & Temperature Controllers

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

LCT100. Load Cell Tester User s Guide (v1711) Anyload Transducer Co. Ltd Website:

02/11/2015

Condition-based maintenance of power transformers Complete three-phase system Turns Ratio: Recovery Voltage: Winding Resistance:

DM-III MULTITEST Power Quality Recorder

Excellent low-cost Process & Temperature Controllers

DM-III Multitest & DM-III Multitest F Power Quality Recorders

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

Custom "Compact" range with display CD20 Custom Part number

Digital conductivity transmitter

U10M. Force Transducer. Special features. Data sheet. Mounting dimensions of the connection variants in mm [inch]

ZITARES LCS Non-SELV, Constant current control gear, 1-channel, non-dimmable

1KVA-2KVA-3KVA 6KVA-10KVA. NUPS22 Series

PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES ECE R10-05

Eurotest 61557, Instaltest 61557

SPECIFICATIONS Digital Indicator 1. General

MIT480/2 Insulation testers

C.A Complete electrical network analysis at the tips of your fingers! Power Quality Monitor. Keeping up with the standards

Applications Features

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

INFOCAL 8 Energy calculator

Model Sono-Trak Transit Time

CONTENTS LOAD CELLS / FORCE TRANSDUCERS TR CM CU AM TC TU TH CC CT SB SH CB OC OD CIR CIR-D

Transcription:

2009 Load Cells Electronic Indicators

Presentation Technologies S.A., is a company that has been created to provide solutions in the field of load cells and weighing electronics, it offers the best solutions according to customer demands, prioritizing dynamic and personalized service, depending on the needs of each client with their own particularities. High technology in the manufacturing process and rigorous quality controls in addition to an extensive experience of more than 20 years in the manufacture of electronic load cells and weighing guarantee us as a competitive vanguard company, capable of meeting the more stringent requirements imposed by different sectors of industry and weighing. The products / services offered are as follows: - Design and Manufacture of load cells, analog and digital systems anti-overturn, supports, accessories, etc.. - Design and Manufacture of Electronic Weighing: electronic digital displays, electronic boards, union boxes, dispensing systems, multiplatform, etc Senel Technologies S.A. has marked itself as an objective to ensure greater competitiveness by expanding the existing market, from the manufacture of high quality, technologically innovative products, which highlighting both for its reliability as their performance over the rest of our competitors. Senel Technologies S.A. is aware that the best argument to compete in the market is a good Quality policy, which is in itself a guarantee for continuity and future of the company. Senel Technologies S.A. undertakes to meet customers' needs, with emphasis on responding to our customers' requirements which are the main driver of our business, understanding that the quality of the service is a right of the customer and is part of the style of our company team. Therefore it is vitally important to find and maintain customer confidence in our products, without forgetting that the attention given to our customers should highlight by its effectiveness, courtesy and kindness.

MN-B / MN-C Capacity (Emax) 5 7 10 15 18 20 36 40 kg Measuring element from steel alloy Protected against corrosion by nickel-plated treatment High accuracy with off-center loads 380 x 380 mm MN-B MN-C 31 2,5 31 31 31 4 15 6 19 75 M6 16 15 40 15 6 19 65 M6 15 16 40 125 6 19 6 115 6 19 6 C3 - C4 Vmin Emax / 12.000 Rated output 2 mv/v ± 10% Excitation voltage 5 to 15 V Connections Input resistance 390 Ω ± 10 Ω In + Red Output resistance 350 Ω ± 4 Ω In - Black Insulation resistance to 50V dc > 5000 MΩ Out + Green Combinated error < ± 0.02 % Salida Nominal Temperature limits OIML R60-10 to 40 ºC Out - White Protected against humidity Overload without permanent deformation Breaking load Load cell cable length IP-67 150 % Emax > 500 % Emax 5 m (MN-B model) 1 m (MN-C model)

MN-6 / MN-8 / MN-10 Capacity (Emax) MN6: 25-50 - 75-100 - 150-200 - 250 kg MN8: 50-75 - 100-150 - 200-250 - 300-500 kg MN10: 300-500 - 750-1000 kg Measuring element from stainless steel High accurancy: - MN-6 with off-center 500 x 500 mm - MN-8 with off-center 600 x 600 mm - MN-10 with off-center 800 x 800 mm MN-6 MN-8 MN-10 8 30 94 30 8 6 19 75 19 6 7 24 83 24 7 45 17 20 3,5 31 4,5 31 3,5 25 4xM6 7 45 59 20 38 38 3,5 46 46 5 15 5 35 4xM8 7 21 59 4xM10 9 41 125 6 19 6 145 7 24 7 9 170 8 30 8 C3 - C4 Vmin Emax / 12.000 Rated output 2 mv/v ± 10% Connections Excitation voltage 5 to 15 V In + Red Input resistance 390 Ω ± 10 Ω In - Black Output resistance 350 Ω ± 4 Ω Out + Green Insulation resistance to 50V dc > 5000 MΩ Out - White Combinated error < ± 0.02 % Output Temperature limits OIML R60-10 to 40 ºC Protected against humidity Overload without permanent deformation Breaking load Load cell cable length IP-67 150 % Emax > 500 % Emax 5 m

FLE-1 / FLE-2 Capacity (Emax) FLE-1: 15 25 50 100 150 200 kg FLE-2: 15 25 30 50 75 100 150 200 250 300 500 750 1000 1500 kg Measuring element from stainless steel Hermetically sealed, fully welded Protected against humidity IP68 FLE-1 120 FLE-2 136,5 53,5 45,5 53,5 52,5 22 = = 3 tal. Ø8.5 Ø30 22 3 Tal. Ø13 50 Ø50 Ø30 82,5 18 10 82,5 25 16 C3 Vmin Emax / 10.000 Rated output 2 mv/v ± 10% Connections Excitation voltage 5 to 15 V In + Red Input resistance 390 Ω ± 10 Ω In - Black Output resistance Insulation resistance to 50V dc Combinated error 350 Ω ± 4 Ω > 5000 MΩ < ± 0.02 % Output Out + Out - Green White Temperature limits OIML R60-10 to 40 ºC Protected against humidity Overload without permanent deformation Breaking load Load cell cable length IP-68 150 % Emax > 500 % Emax 5 m

CT-1 / CT-2 Capacity (Emax) CT1: 300-500 - 750-1000 - 1500 kg CT2: 2000-3000 - 4000-5000 kg Measuring element from stainless steel Protected against humidity IP67 Multicells scale assembly CT-1 CT-2 L1 19 40 L4 136 31 24 52 74 Ø 13 Ø 13 M14 = = = = L5 L2 L3 ØD ØD M20 16 25 82,5 Capacidad L1(mm) L2(mm) L3(mm) L4(mm) L5(mm) D(mm) 2000 a 4000 175 34 32 98 43 21 5000 200 45 43 123 45 20.5 C3 Vmin Emax / 10.000 Rated output 2 mv/v ± 0.1% Connections Excitation voltage Input resistance Output resistance Insulation resistance to 50V dc Combinated error 5 to 15 V 350 Ω ± 10 Ω 350 Ω ± 4 Ω > 5000 MΩ < ± 0.02 % Output In + In - Out + Out - Red Black Green White Temperature limits OIML R60-10 to 40 ºC Protected against humidity Overload without permanent deformation Breaking load Load cell cable length IP-67 150 % Emax > 500 % Emax 5 m

CT-A0 Capacity (Emax): 30-50 - 75-100 - 150-200 - 250-300 - 500 kg Measuring element from stainless steel Protected against corrosion by nickel-plated treatment Protected against humidity IP67 Multicells scale assembly 16 25,4 76,2 12,4 L1 L2 L3 Ø13,5 15,5 = = Ø13.5 (2 tal.) Capacidad L1(mm) L2(mm) L3(mm) 30 kg 55 50.5 24.5 Resto 58 45.5 26.5 31,5 16 130 M12 C3 Vmin Emax / 10.000 Rated output 2 mv/v ± 0.1% Excitation voltage 5 to 15 V Input resistance 350 Ω ± 10 Ω Output resistance 350 Ω ± 4 Ω Insulation resistance to 50V dc > 5000 MΩ Combinated error < ± 0.02 % Output Connections In + Red In - Black Out + Green Out - White Temperature limits OIML R60-10 to 40 ºC Protected against humidity Overload without permanent deformation Breaking load Load cell cable length IP-67 150 % Emax > 500 % Emax 5 m

CT-A1 Capacity (Emax): 400-500 - 750-1000 - 1500 kg Measuring element from stainless steel Multicells scale assembly Hermetically sealed, fully welded Protected against humidity IP68 Ø13,5 31,5 15,5 29 57 2,5 M12 Ø13 (2 tal.) 31,5 16 25,4 76,2 130 C3 Vmin Emax / 10.000 Rated output 2 mv/v ± 0.1% Connections Excitation voltage Input resistance Output resistance Insulation resistance to 50V dc Combinated error 5 to 15 V 350 Ω ± 5 Ω 350 Ω ± 4 Ω > 5000 MΩ < ± 0.02 % Output In + In - Out + Out - Red Black Green White Temperature limits OIML R60-10 to 40 ºC Protected against humidity Overload without permanent deformation Breaking load Load cell cable length IP-68 150 % Emax > 500 % Emax 5 m

SX-1 Capacity (Emax): 30-50 - 75-100 - 150 kg Measuring element from steel alloy Protected against corrosion by nickel-plated treatment Protected against humidity IP67 Applications: cisterns, hooks,.. 60 A = = Capacidad (kg) A (mm) 30 15 60 50 15 75 15 100 15 150 20 Ø 9,5 C3 Vmin Emax / 10.000 Rated output 2 mv/v ± 0.1% Connections Excitation voltage Input resistance Output resistance Insulation resistance to 50V dc Combinated error 5 to 15 V 350 Ω ± 5 Ω 350 Ω ± 4 Ω > 5000 MΩ < ± 0.02 % Output In + In - Out + Out - Red Black Green White Temperature limits OIML R60-10 to 40 ºC Protected against humidity Overload without permanent deformation Breaking load Load cell cable length IP-67 150 % Emax > 500 % Emax 5 m

SX-2 / SX-3 Capacity (Emax) SX2: 300-500 - 750-1000 kg SX3: 750-1000 - 1500-2000 - 2500-3000 - 5000-6000 - 10000 kg Measuring element from steel alloy Protected against corrosion by nickel-plated treatment Protected against humidity IP67 Applications: cisterns, hooks,.. SX-2 SX-3 49 = = A 80 = = A = 47 = 80 = = M12 Capacidad (kg) A(mm) B 300 20 500 26 750 26 1000 26 C3 Vmin Emax / 10.000 Rated output 2 mv/v ± 0.1% Connections Excitation voltage Input resistance Output resistance Insulation resistance to 50V dc Combinated error 5 to 15 V 350 Ω ± 5 Ω 350 Ω ± 4 Ω > 5000 MΩ < ± 0.02 % Output In + In - Out + Out - Red Black Green White Temperature limits OIML R60-10 to 40 ºC Protected against humidity Overload without permanent deformation Breaking load Load cell cable length IP-67 150 % Emax > 500 % Emax 5 m

DC-1 Capacity (Emax): 3000-4000 - 5000-7500 - 10000 kg Measuring element from stainless steel Protected against humidity IP67 Truck scales and cisterns assembly 185 75 90 65 52 67 4 tal. Ø10 C3 Vmin Emax / 10.000 Rated output 2 mv/v ± 0.1% Excitation voltage 5 to 15 V Connections Input resistance 700 Ω ± 10 Ω In + Red Output resistance 700 Ω ± 4 Ω In - Black Insulation resistance to 50V dc > 5000 MΩ Out + Green Combinated error < ± 0.02 % Output Temperature limits OIML R60-10 to 40 ºC Out - White Protected against humidity Overload without permanent deformation Breaking load Load cell cable length IP-67 150 % Emax > 500 % Emax 5 m

DC-2 Capacity (Emax): 5000-10000 - 15000-20000 - 25000 kg Measuring element from stainless steel Protected against humidity IP67 Truck scales and cisterns assembly Protected against atmospheric discharges 120 86 76 91 243 90 4 tal. Ø10 C3 Vmin Emax / 10.000 Rated output 2 mv/v ± 0.1% Connections Excitation voltage 5 to 15 V Input resistance 700 Ω ± 5 Ω Output resistance 700 Ω ± 4 Ω Insulation resistance to 50V dc > 5000 MΩ Combinated error < ± 0.02 % Output Temperature limits OIML R60-10 to 40 ºC Protected against humidity IP-67 In + Sense + In - Sense - Out + Out - Red Yellow Black Blue Green White Overload without permanent deformation Breaking load Load cell cable length 150 % Emax > 500 % Emax 15 m

INTRO PRINT VN1 - VN1/LCD Basic Configuration INOX shell Display LED 20mm (VN1) or LCD 16 characters (VN1/LCD) 10000 Divisions Minim input voltage per verification scale interval 1uV Weight - Tare Counting indicator RS232 interface Languages: Spanish, English, French, Italian & portuguese Protocols Programmable head ticket and scroll Manual and fast tare Blocking tare Numeric codes Ticket repetition Autoacumulate Options Aditional output RS485 interface RF interface Repeater output Relay output: - 4 Out - 2 In Analogic output: - 4-20mA - 0-10V - 1 In Clock-calendar III & IIII 265 60 Max. number of verification scale intervals 10000 0 net T B BAT Load cell excitation power supply 8 VDC kg 125 Max. signal voltage for dead load 0 to 16 mv T B 0 FUN Min. input voltage per verification scale interval 1 µv Measuring voltage range Load cell impedance range 10 to 24 mv 40 to 2000 Ω Temperature range -10 to 40 ºC Power supply requirements Power supply requirements (battery indicators) Sense system Load cell cable length (4 wire systems) Load cell cable length (6 wire systems) 220 VAC 12 or 24 VDC Available 5m/mm No limit

INTRO PRINT VN60 Basic Configuration INOX shell Display LED 60mm 10000 Divisions Minim input voltage per verification scale interval 1uV Weight - Tare Counting indicator RS232 interface Languages: Spanish, English, French, Italian & portuguese Protocols Programmable head ticket and scroll Manual and fast tare Blocking tare Numeric codes Ticket repetition Autoacumulate Options Aditional output RS485 interface RF interface Repeater output Relay output: - 4 Out - 2 In Analogic output: - 4-20mA - 0-10V - 1 In Clock-calendar III & IIII Max. number of verification scale intervals Load cell excitation power supply 10000 8 VDC 360 80 Max. signal voltage for dead load 0 to 16 mv 0 net T B BAT Min. input voltage per verification scale interval 1 µv Measuring voltage range 10 to 24 mv Load cell impedance range 40 to 2000 Ω 202,5 T B 0 FUN kg Temperature range -10 to 40 ºC Power supply requirements Power supply requirements (battery indicators) Sense system Load cell cable length (4 wire systems) Load cell cable length (6 wire systems) 220 VAC 12 or 24 VDC Available 5m/mm No limit

VN1/P - VN1/P_LCD Basic Configuration INOX shell Display LED 20mm (VN1) or LCD 16 characters (VN1/LCD) 10000 Divisions Minim input voltage per verification scale interval 1uV Weight - Tare Counting indicator RS232 interface Languages: Spanish, English, French, Italian & portuguese Protocols Programmable head ticket and scroll Manual and fast tare Blocking tare Numeric codes Ticket repetition Autoacumulate Options Aditional output RS485 interface RF interface Repeater output Clock-calendar III & IIII Max. number of verification scale intervals 10000 Load cell excitation power supply 8 VDC Max. signal voltage for dead load 0 to 16 mv Min. input voltage per verification scale interval 1 µv 40 265 139 96 139 Measuring voltage range Load cell impedance range 10 to 24 mv 40 to 2000 Ω 125 Temperature range -10 to 40 ºC Power supply requirements Power supply requirements (battery indicators) Sense system Load cell cable length (4 wire systems) Load cell cable length (6 wire systems) 220 VAC 12 or 24 VDC Available 5m/mm No limit

INTRO PRINT VA-1 Basic configuration INOX shell Display LED 20mm & Alphanumeric 4 lines with 20 characters per line 10000 Divisions Minim input voltage per verification scale interval 1uV Truck-weighing indicator Double RS232 interface Tares, plates, products, customers and suppliers in memory Open weighing operations and log Auto detect first and second weighing Data base customizable Data Base and PC synchronize PS/2 interface (PC keyboard) Clock-calendar included Options RS485 interface RF interface Repeater output Max. number of verification scale intervals III & IIII 10000 117 Load cell excitation power supply 8 VDC 0 net T B BAT Max. signal voltage for dead load 0 to 16 mv kg Min. input voltage per verification scale interval 1 µv T B 0 FUN 224 Measuring voltage range 10 to 24 mv Load cell impedance range 40 to 2000 Ω Temperature range -10 to 40 ºC 320 Power supply requirements Power supply requirements (battery indicators) Sense system Load cell cable length (4 wire systems) Load cell cable length (6 wire systems) 220 VAC 12 or 24 VDC Available 5m/mm No limit

VN-1/MONEDERO Basic configuration LCD display with 16 characters Selector de monedas o pulsador 10000 Divisions 1uV interval Double RS-232 interface for PC and Printer Languages: Spanish, English, French, Italian & portuguese Protocols Programmable head ticket and scroll Ticket repetition Options Alfanumeric keyboard ibutton PS/2 interface (PC keyboard) RS485 interface RF interface Repeater output Max. number of verification scale intervals Load cell excitation power supply III & IIII 10000 8 VDC 270 Max. signal voltage for dead load 0 to 16 mv Min. input voltage per verification scale interval 1 µv 400 400 Measuring voltage range 10 to 24 mv Load cell impedance range 40 to 2000 Ω 345 200 Temperature range -10 to 40 ºC Power supply requirements Power supply requirements (battery indicators) Sense system Load cell cable length (4 wire systems) Load cell cable length (6 wire systems) 220 VAC 12 or 24 VDC Available 5m/mm No limit

INTRO PRINT INTRO PRINT VN-1Rep / VN-60Rep Basic configuration INOX shell Display LED with 20mm digits Power supply for data cable Until 100 meters between repeater and indicator Options Protected against humidity IP65 265 60 0 net T B BAT kg 125 T B 0 FUN 360 80 0 net T B BAT 202,5 kg T B 0 FUN

INTRO PRINT INTRO PRINT VN-1RInt / VN-60RInt Basic configuration INOX shell Display LED with 20mm or 60mm digits RS232 interface for PC and printer connection Languages: Spanish, English, French, Italian & portuguese Protocols Programmable head ticket and scroll Manual and fast tare Blocking tare Numeric codes Ticket repetition Autoacumulate Options Aditional output RS485 interface RF interface Repeater output Relay output: - 4 Out - 2 In Analogic output: - 4-20mA - 0-10V - 1 In Clock-calendar Especial protocols VN-1 VN-60 360 80 265 60 0 net T B BAT 0 net T B BAT T B 0 FUN kg 125 202,5 kg T B 0 FUN

Load Cell - Compatibility table Sensocar Eurobil HBM Vishay Scaime Utilcell Epelsa Campesa Transdut ec Ascell MN-B BL EBL MN-C BL-C EBLC MBE MN-6 PL-50 MN-8 BS-1 MN-10 BS-2 FLE-1 FX-1 Z6 355 F60X 300 Lb2 FL-1 CFLI FLE-2 FX-2 340 Sb2 SC CTF-1A FL-1A TCC-1 GS1-A CFSI CT-1 CO-1 CTF-1A CT-2 CO-2 CTF-1B CT-A0 TA-0 3410 3510 350 Lc2 CF CFI CT-A1 TA-1 HLC ELC BLC 3420 3510 F60X 350 LC TCC-4 CS CSI DC-1 DCO-2 DC-2 DCO-3 STR CB SX-2 S2-A RSCA STC6001 ZFA TSF S TSC-1 TC SX-3 S2-B S TT

www.senel.es Pol. Industrial Cova Solera 08191 RUBI (Barcelona) Telf: +34 936 977 943 Fax: +34 936 977 944 E-mail: senel@senel.es Internet: www.senel.es