OMEGAMONITOR BOM-L1 TR W

Similar documents
MANUAL BMS SPEC5000 Spectrophotometer

LA-T SERIES. Fast and reliable minute granular flaw detection in winding wires. Winding Wire Granular Flaw Detector PARTICULAR USE SENSORS

OPERATING MANUAL MINIDOP ES-100VX POCKET DOPPLER

USER MANUAL FOR VISIBLE SPECTROPHOTOMETER

INSTRUCTION MANUAL Vibration Meter

Distance-setting Photoelectric Sensor

Operating Manual. Model 721N. Visible Spectrophotometer

Instruction manual SUN-PM100L. SUN-PM100L Polishing Machine English

INSTRUCTION MANUAL MODEL 21 MULTI-TESTER

SFP-550. Operating Manual MATSUHIDAI, MATSUDO-CITY, CHIBA JAPAN TEL: FAX:

Distance-setting Photoelectric Sensor

Medical Electronics Dr. Neil Townsend Michaelmas Term 2001 ( Pulse Oximetry: The story so far

D5.1 Report on the design of a fibre sensor based on NIRS

PRODUCT SHEET. fnir 2000C Imager fnir2000s Imager fnir2000p Imager

SFP-550. Operating Manual MATSUHIDAI, MATSUDO-CITY, CHIBA JAPAN TEL: FAX:

Solar Cell Parameters and Equivalent Circuit

V-Solder. Instruction manual. BON-6002 V-Cut solder machine Solder diameter φ0.6~φ1.6. (User s Manual) Preparation in April 2014.

P-CUBE-Series High Sensitivity PIN Detector Modules

PD-3000UV. INSTRUCTION MANUAL UV-VIS Spectrophotometer OMA IMPORTANT!

Infrared Endoscopy and its Practicality for Surgery. Phys 173 June 2014 Kevin Kohler A

PhO 2. Smartphone based Blood Oxygen Level Measurement using Near-IR and RED Wave-guided Light

Using the Integrating Sphere in the Multiple Application Platform (MAP)

Photonics and Optical Communication Spring 2005

Installing the detector filter assembly (G )

577 nm: The Preferred Wavelength

HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE

User instructions Compound laboratory microscope

Better diagnosis and treatment all-in-one.

E3Z-LS. Distance-settable Photoelectric Sensor. Ordering Information. Sensors. Accessories (Order Separately)

User Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com

Wireless Sensor Networks. EP2980

LX-100 SERIES. Digital Mark Sensor Amplifier Built-in. Introduction of the 3 LED mark sensor 4:1. Can detect any mark!

(a) Imaging Veins Superficial veins that are less than 3 mm deep can sometimes be seen as blue-green (often raised) areas of the skin.

User instructions Compound laboratory microscope

M302RM OPERATING MANUAL

ADAE portable X ray machine Operation manual

RAGU 81D DIGITAL MULTIMETER OPERATION MANUAL

rainbow ReSposable Pulse CO-Oximeter Sensor System Training Please see product s Directions for Use for more information 2012 Masimo Corporation

Spectroscopy of Ruby Fluorescence Physics Advanced Physics Lab - Summer 2018 Don Heiman, Northeastern University, 1/12/2018

80-MHz Balanced Photoreceivers Model 18X7

Operating mode. distance. 7 m Light ON Dark ON (selectable) 2 m [100 mm] (See note 1.) 100 mm (wide view)

An Advanced Architecture & Instrumentation for Developing the System of Monitoring a Vital Sign (Oxygen Saturation) of a Patient.

NON-AMPLIFIED PHOTODETECTOR USER S GUIDE

M-DW1. Wafer Mapping Sensor. The safe LED beam reflective type wafer mapping sensor. Safe LEDs adopted. Sensing of nitride-coated wafers possible

Laser Source. Photonic Power Module (PPM) Assembly Drawing. Key Features: Applications:

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

TABLE OF CONTENTS. Safety notes i. Care and Maintenance. ii. 1. Components Illustration Installation of Components.. 4

Label Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor

600 AAC Clamp Meter Instruction Manual

DIGITAL LASER DISTANCE METER

INSTRUCTION MANUAL PCE-222

IP Series DUAL POWER AMPLIFIERS

Directions for Use. Veinlite A. TransLite, LLC.

University of Wisconsin Chemistry 524 Spectroscopic Components *

Dawson DSM150. Digital Light Meter User s Manual

The OXY100C outputs four signals simultaneously, as shown in this graph: O 2 Saturation (beat-by-beat, CH 1) Pulse Waveform (beat-by-beat, CH 5)

High Speed Air Turbine Handpiece

User s Manual Current Probe. IM E 2nd Edition IM E

FluorCam PAR- Absorptivity Module & NDVI Measurement

MIT415 Insulation tester

Surgical Handpiece. Ti-Max Ti-Max Ti-Max Ti-Max X-SG20L X-SG25L X-SG93L X-SG93. S-Max SG M OM-C0425E

A510S Operation Manual

V-SOLDER BON-8103/8203. V-cut solder machine. Applicable solder wire diameter 0.3 ~ 0.8 mm

National 3 Physics Waves and Radiation. 1. Wave Properties

Atomscope PORTABLE VETERINARY X-RAY EQUIPMENT INSTRUCTION MANUAL. Version 1.0

88950-A Series A Series INSTRUCTION MANUAL

15-GHz & 25-GHz Photodetectors Models 1480-S & 1481-S

INSTRUCTION MANUAL MODEL 8820 Multi-Function Environment Meter

Measurement Method of High Absorbance (Low Transmittance) Samples by UH4150 INTRODUCTION

paper title : Analyzing the Components of Dark Circle by Nonlinear Estimation of Chromophore Concentrations and Shading

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

FiberLink 4040 Series

Unit 2 Semiconductor Devices. Lecture_2.5 Opto-Electronic Devices

Spectroscopy Application: Using Raman Spectroscopy to Detect Art Forgeries Detecting art forgeries using Raman spectroscopy

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

EXPRIMENT 3 COUPLING FIBERS TO SEMICONDUCTOR SOURCES

3B SCIENTIFIC PHYSICS

M-1000D DIGITAL MULTIMETER

User instructions Metallurgical microscope

Table 8 Overview light sources

User s Manual. Model MS5 Potentiometer Converter (Free Range Type) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

DISSOLVED OXYGEN TRANSMITTER

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

80-MHz Balanced Photoreceivers Model 18X7

Reprint (R37) DLP Products DMD-Based Hyperspectral Imager Makes Surgery Easier

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

YAESTJ. Antenna Rotator Model G-450XL

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

Model: &

Nuclear Associates

LlIGHT REVIEW PART 2 DOWNLOAD, PRINT and submit for 100 points

LEDs, Photodetectors and Solar Cells

AC/DC True RMS Power Clamp Meter ELECTRONIC TEST INSTRUMENTS MODEL 325

3B SCIENTIFIC PHYSICS

Ophthalmic Slit-lamp Microscope (SLM 1ER) Operation. Instruction

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

EE-SX770/771/772/870/871/872(A/P/R)

OPTO-ELECTRONIC DEVICES

ModBox - Spectral Broadening Unit

Sensors. CSE 666 Lecture Slides SUNY at Buffalo

Transcription:

Laser Tissue Blood Oxygenation Monitor OMEGAMONITOR BOM-L1TR W BA4D9013-3 OMEGAMONITOR BOM-L1 TR W USER'SMANUAL

CONTENTS Page 1. Summary 2 2. Part names and Function 3 3. Connection to Recorder and Operation 9 4. Theory 13 5. Handling and Cautions 16 6. Specifications 19 7. Guarantee 20 1

1. Summary This laser tissue blood oxygenation monitor, OMEGAMONITOR BOM-L1TRW, is an useful instrument for measuring tissue blood volume and its oxygenation in muscle, brain and internal organs. BOM-L1TRW can measure the hemodynamics continuously and non-invasively, and is used in fundamental research and in clinical applications. BOM-L1TRW has two detection system. One is for measuring the shallow part from the surface and the other is for measuring the deeper part from the surface of tissue. The differential of these two outputs can tell the hemodynamics only in the deep part. The measurement depth is relational to the distance between the incidence and receiving point, and it is almost same as the distance. BOM-L1TRW uses three semiconductor laser diodes, and their narrow bandwidth of spectrum enables high S/N ratio measurement. BOM-L1TRW outputs oxygenated hemoglobin volume, deoxygenated hemoglobin volume, total hemoglobin volume and its oxygenation continuously, then the detail of hemodynamics under study can be observed. 2

2. Part names and Functions 1) Part names Front panel 1Indicator 2Detector indicator 3Mode switch 4Set switch 5Distance switch 6Laser switch 7Indicator for detector level 8Indicator for probe level 9Optical connectors Red : Incidence Black : Receiving 10Connector for detector 11Handle Rear panel 12Gain adjustment switch nfor probe 13Gain adjustment switch for detector 14Selection switch for indicator 15Selection switch for AVG 3 16Outputs 17Power switch 18Ground terminal 19AC power input

Probe 20 Detector 21 Detector plug 4

2) Functions Indicator This indicator shows the measurement value of tissue blood oxygenation ratio and total Hb volume. The tissue blood oxygenation ratio, StO2, is showed as percentage, and total Hb volume, TOTAL Hb, is showed as 0 100.0. The oxy-hb volume, OXY HB, and deoxy-hb volume, DEDOXY Hb, are not showed in this indicator, but all of StO2, Total Hb, OXY Hb and DEOXY Hb are obtained from the output on the rear panel. Output mode has three modes. "MEA" mode is for measurement, "0" mode shows 0 (zero) on this indicator and sets the output to 0 (V), and "CAL" mode shows calibration value and outputs its voltage. The calibration value of StO2 on the indicator is 10.0 and the value of TOTAl Hb is 20.0. The calibration voltage of the output of OXY Hb, DEOXY HB and StO2 are 1.0 (V) respectively, and the voltage of TOTAL HB is 2.0(V). TOTAL Hb = OXY Hb + DEOXY Hb Detector indicator : This indicator shows the detector number selected by Selection switch for indicator. The Indicator shows the values of the detector shown on this Detector indicator. Mode switch The output mode of "MEA" "0" and "CAL" is selected by this switch. Set switch This switch is used for measuring the value of change from a point. When this switch is pushed, OXY-Hb, DEOXY-HB and TOTAL-Hb become zero. Then just the volume change is obtained. However, StO2 is not affected by this switch. The red light shows "ON". This switch is controlled when Mode switch shows "MEA", Laser switch is "ON", Detector level shows green light and Probe level shows green light. 5

Distance switch This switch is for normalizing the distance between Probe and Detector on tissue. Input the distance as the unit of "mm". Laser switch Laser power is operated by this switch. Press this switch for ON and the red light glows. 7 Indicator for detector level This indicator shows the level of detected light intensity detected by the detector. The hemodynamic values are obtained when this indicator shows green. When it shows red at L or H level, adjust the detection level using "12Gain adjusting switch for detector" to become green. L level means low detected light intensity, and H level does high intensity for processing the signal. The larger number of switch means higher gain. 8 Indicator for probe level This indicator shoes the level of detected light intensity detected by the probe. This light intensity is used to compensate the output laser power on tissue and absorption by pigment in the tissue. The hemodynamic values are obtained when this indicator shows green. When it shows red at L or H level, adjust the detection level using "11Gain adjusting switch for probe" to become green. L level means low detected light intensity, and H level does high intensity for processing the signal. The larger number of switch means higher gain. 9 Optical connectors Optical connectors to connect the probe. The plugs of standard probes are specified by RED and BLACK. Match the key of the plug of the probe with the ditch of the connector, and push and screw the plug. 6

⑩ Connector for detector Put the plug of the detector into this connector. ⑪ Handle Use this handle for carrying BOM-L1TRW. ⑫ Gain adjustment switch for probe This selection switch is used to adjust the detected light intensity level of the probe. Usually the position of "2" is widely used for many tissue. When dark tissue is measured and the indicator for probe level shows red at L, set to "3". When white tissue is measured and the indicator for probe level shows red at H, set to "1". ⑬ Gain adjustment switch for detector This selection switch is used to adjust the detected light intensity level of the detector. The detected light intensity is affected by the distance between the probe and the detector. 7

When the indicator for detector level shows red at L, turn this switch to higher number. When the indicator for detector level shows red at H, turn this switch to lower number. Selection switch for indicator This switch is for selecting which detector's value is shown on Indicator. The outputs are not affected by this switch. Selection switch for AVG The average of the output voltage can be set by this switch. The averaging time is 1, 2 or 5 sec. Outputs The three connectors output OXY Hb, DEOXY Hb and TOTAL Hb for each DET1, DET2 and DET2-1. DET1 : This outputs the signal from the shallow part of a tissue from the surface. DET2 : This outputs the signal from the deeper part of a tissue from the surface. DET2-1 : This outputs the differential value after calculating each Hb values. This DET2-1 is calculated as DET2-1 = {(DET2 L2) - (DET1 L1)} / (L2-L1). L2 and L1 : Distance between the incidence and receiving set by Distance switch. The range of the voltage is 0 10(V). When the set switch shows "ON", the range is -10 +10(V). 0 (zero) (V) is generated on each parameter on "0" mode. 1(V) is obtained for OXY Hb and DEOXY Hb on "CAL" mode. 2(V) is obtained for TOTAL Hb on "CAL" mode. Power switch This switch is used for "ON-OFF". Ground terminal To connect another instrument to make the ground level same. 8

AC power input Insert 3P power cord. Probe plug This is connected to the optical connector on BOM-L1TRW. Match the key of the plug of the probe with the ditch of the connector, and push and screw the plug. (21)Detector plug This is connected to the detector connector on BOM-L1TRW. 9

3. Connection to Recorder and Operation 1) Connection to a recorder (1) Connect the output of BOM-L1TRW to the inputs of a recorder using the signal cable having three black and red banana jacks. Black banana jacks are grounds and red ones are signals for each hemodynamics parameters. (2)Put the power source cord into the "AC power input" of BOM-L1TRW and connect to a power source. 2) Operation (1) Insert the plugs of a probe into the optical connectors of BOM-L1TRW and screw the coupling of the plugs to the right by one hand holding the black rubber boots not to turn by the other. Insert the plugs slowly and in a straight line. Do not insert the plugs slantwise by force. BOM-L1TRW has laser incidence and receiving optical connectors. Insert the red plug of the probe into the red mark connector, and the black plug into the black connector. The probe not being colored has no side. Both plugs of the probe can be inserted into either side of the optical connectors. (2) Insert the plug of the detector into the connector for the detector. (3) Put the probe and the detector on the tissue under study. To avoid the light from outside, put the optional probe holder, a black rubber sheet or venal tape over them. (4) Input the distance between the probe and detector in the distance switch. The unit is "mm". Use the small switches over and under these digital switches to input the numbers. 10

The distance between the probe and the detector 1 should be shorter than that between the probe and the detector 2. Input the distance between the probe and the detector 1 for DET1. Input the distance between the probe and the detector 2 for DET2. (5) Turn on BOM-L1TRW and the recorder by each power switch. (6) Turn "LASER" switch on. The red lamp is lighted. Confirm the green light on both the detector level and probe level. When they shows red, adjust the gain adjustment switch for the detector and probe on the rear panel. (7)Calibration Set the full scale of a recorder at 10 (V) using the range dial of the recorder. Press "MODE" switch and set at "0". Set the pen of the recorder at zero line using the zero null dial of the recorder. Press "MODE" switch again and set at CAL". OXY Hb : 10.0, DEOXY Hb : 10.0, TOTAL Hb : 20.0, St02 : 10.0 are obtained from the out put of BOM-L1 TR. The each voltage is 1 (V) for OXY Hb, DEOXY Hb and StO2, and 2(V) for TOTAL Hb. Set the pen of the recorder at an adequate point. Run the chart paper and make the calibration form showed below operating to again. 11

(7) Press "MODE" switch to set at "MEA". Measurement starts. (8) Raise the gain of the recorder if the measuring wave is too small. (9) Chose the AVG switch on the rear panel. To obtain averaged measuring wave, choose longer time-constant. Once the recorder is adjusted, this "Calibration" section will not be needed. 3) Stop Operating (1) Stop the chart of the recorder, and turn off "LASER" switch. (2) Turn off the power switch of BOM-L1TRW. (3) Remove the probe from BOM-L1TRW slowly. Do not pull the plugs out slantwise by force. (4) Cap the optical connectors. (5) Cap the plugs of the probe and keep it in the probe case. 12

4. Theory 1) NIRS (Near InfraRed Spectroscopy) The absorption spectrum of light by oxygenated hemoglobin and deoxygenated hemoglobin are different. Three kinds of laser lights illuminate tissue and the scattered light is detected at the point separated 30-50 mm from the incident point. As tissues are highly scattering materials in the wavelength range between 500 and 900 nm, photons are scattered many times in tissue, and some of them are absorbed by hemoglobin in erythrocytes. The absorption coefficient of hemoglobin depends on wavelength, and the detected light intensity can be expressed as Here, I = ηio exp [( -αvo - βvd - µ) L]. (1) I : detected light intensity Io : incident light intensity η : the coefficient of measurement system α : absorption coefficient of oxy-hemoglobin β : absorption coefficient of deoxy- hemoglobin Vo : volume fraction of oxygenated blood(hemoglobin) in tissue Vd : volume fraction of deoxygenated blood(hemoglobin) in tissue µ : attenuation(scattering + absorption) coefficient of tissue L : optode, the distance between the incident point and the detected point. Using three laser lights, we can obtain the volume fraction of oxygenated and deoxygenated blood in the tissue as Here, Vo L= A [Ln (I1/I10) - Ln (I2/I2O)] + B [Ln (I2/I20) - Ln (I3/I3O)] (2) Vd L= C [Ln (I1/I10) - Ln (I2/I2O)] + D [Ln (I2/I20) - Ln (I3/I3O)]. (3) I1 I2 and I3 are the detected light intensity of the three laser wavelengths 1, 2, and 3 respectively, 13

I10 I20 and I30 are the incident light intensity of the three laser light, A, B, C and D are the coefficients obtained from α1, α2, α3, β1, β2, and β3, α1, α2 and α3 are the absorption coefficient of oxy- hemoglobin at the three laser wavelengths, and β1, β2, andβ3 are the absorption coefficients of deoxy-hemoglobin at the three laser wavelengths. Usually, the assumption that the scattering coefficient of tissue itself are the same for each wavelength if the wavelengths are close enough to each other. The oxygenation of the blood, StO2, is calculated as StO2 = Vo / (Vo + Vd). (4) 2) Unit and Indication The indication of 1.0 and output of 0.1(V) for OXY Hb, DEOXY Hb and TOTAL Hb is equivalent to about 1 104[N/mm3] of the density of erythrocyte in tissue in the condition that the actual optical pass length in tissue is assumed 4 times of the distance between the probe and detector. The laser light is basically absorbed by hemoglobin. However, in a living tissue, hemoglobins are contained in red blood cells, and hemoglobin does not exist in blood alone. Also, the light is absorbed and scattered by red blood cells actually. Therefore, BOM-L1TRW indicates the blood volume as the number of red blood cells in a unit volume of tissue. As the volume of hemoglobin, 1[µmol/100mL] 2.2 10 4 [N/mm3]. 14

Analog output D/A converter CPU A/D converter A/D converter Laser controll circuit DC voltage + - G Lasers Power circuit Probe Fuse Noise filter Power switch Block diagram 15

5. Handling and Cautions 1) Pay attention to the next matters. (1) Keep BOM-L1TRW out of water. (2) Set BOM-L1TRW on the place where air pressure, temperature, humidity, wind, sunlight, dust, and air containing salt and sulfur do not cause bad condition. (3) Pay attention to inclination, vibration and shock. (4) Keep BOM-L1TRW out of a storeroom of chemicals and the place where gas generates. (5) Pay attention to the voltage, frequency and power of the power source which BOM- L1TRW is connected to. (6) Connect the ground correctly. 2) Pay attention to the next matters before using BOM-L1TRW. (1) Examine switch workings and meters, and confirm BOM-L1TRW working. (2) Confirm the ground being completely connected. (3) Confirm all the cables being connected correctly and completely. (4) Pay attention to using another instruments together. 3) Pay attention to the next matters in use of BOM-L1TRW. (1) Do not use over the time for diagnosis and medical treatment. (2) Always keep watch on BOM-L1TRW and a patient being not unusual. (3) Take proper measures, like turning of BOM-L1TRW, if something is unusual on BOM-L1TRW and a patient (4) Keep patients out from BOM-L1TRW. (5) Do not look at the laser light generated from BOM-L1TRW directly and through a lens. (6) Probes are made from glass fibers, and they are hardly repaired. Pay attention to the next matters for probes. Do not scrub the tip of probe and detectors. Do not bend into a circle of under 10 mm radius. 16

Do not step on probes. Keep the tip and plugs clean. Do not insert and pull the plugs slantwise by force. Use under 60 sterilization. 4) Pay attention to the next matters after using BOM-L1TRW (1) Turn off the power switch after restoring the condition of before using BOM-L1TRW along the process. (2) Do not pull the cables by force. (3) Pay attention to keeping. Keep BOM-L1TRW out of water. Set BOM-L1TRW on the place where air pressure, temperature, humidity, wind, sunlight, dust, and air containing salt and sulfur do not cause bad condition. Pay attention to inclination, vibration and shock. Keep BOM-L1TRW out of a storeroom of chemicals and the place where gas generates. (4) Put belongings, cables and probes in order after cleaning. (5) Clean BOM-L1TRW for the next using. 5) When BOM-L1TRW is out of order, do not handle. Leave it to a specialist. 17

6) Do not remodel BOM-L1TRW. 7) Maintenance (1) Inspect BOM-L1TRW regularly. (2) Confirm BOM-L1TRW being in order before using it having not used for a long time. 18

6. Specifications Laser for Measurement : Semiconductor lasers Wavelength : 780nm, 810nm and 830nm Under 7mW at the probe end Probe : Optical fiber Detector : Silicon photo-diode Measuring parameters 1)Tissue oxygenated blood volume(oxy Hb) :0 +100.0 2)Tissue deoxygenated blood volume(deoxy Hb) :0 +100.0 3)Tissue total blood volume(total Hb) :0 +100.0 4) Oxygenation ratio (StO2) : 0 100.0 % Indicator : StO2 and TOTAL Hb Analog output 1)OXY Hb : 0 10V 2)DEOXY Hb : 0 10V 3)TOTAL Hb : 0 10V 4)StO2 : 0 10V AVG : 1, 2 and 5 sec Power source : AC110±10V, 50/60Hz, 20VA Weight: 5.5kg Size : W257 H100 D322 (mm) without the handle Operation circumstance Temperature : 5-40 19

7. Guarantee 1) BOM-L1TRW cases. Repair is free within one year after the purchase of BOM-L1TRW except the next (1) Malfunction and damage due to incorrect using and inattention. (2) Malfunction and damage due to a nature calamity and a fire. 2)Probes and Detectors Repair is according to the table below at the first time. after purchase within 6 months within one year after one year cost of repair under 50% of the list price under 70% of the list price not provided 20 OMEGAWAVE, INC 2-20-3 KATAMACHI FUCHU, TOKYO, JAPAN No.