BEAM DISTORTION IN DOPPLER ULTRASOUND FLOW TEST RIGS: MEASUREMENT USING A STRING PHANTOM

Similar documents
A PILOT STUDY ON ULTRASONIC SENSOR-BASED MEASURE- MENT OF HEAD MOVEMENT

In essence we need to solve the first-kind Fredholm equation L c T

A TELE-INSTRUCTION SYSTEM FOR ULTRASOUND PROBE OPERATION BASED ON SHARED AR TECHNOLOGY

Ultrasound Physics. History: Ultrasound 2/13/2019. Ultrasound

DESIGN PRINCIPLES FOR INSULATED INTERNAL LOOPLESS MRI RECEIVERS

Interaction of Sound and. logarithms. Logarithms continued. Decibels (db) Decibels (db) continued. Interaction of Sound and Media continued

Blood Flow Analysis Using Ultrasound Doppler Technique

ACCURACY IMPROVEMENT ON NON-INVASIVE ULTRASONIC-DOPPLER FLOW MEASUREMENT BY UTILZING SHEAR WAVES IN METAL PIPE

Explain what is meant by a photon and state one of its main properties [2]

A miniature all-optical photoacoustic imaging probe

THREE-DIMENSIONAL ACCURACY ASSESSMENT OF EYE SURGEONS

AN APPROXIMATION-WEIGHTED DETAIL CONTRAST ENHANCEMENT FILTER FOR LESION DETECTION ON MAMMOGRAMS

MOVIE-BASED VR THERAPY SYSTEM FOR TREATMENT OF ANTHROPOPHOBIA

Ultrasound Beamforming and Image Formation. Jeremy J. Dahl

Nuove tecnologie per ecografia ad ultrasuoni: da 2D a 4D

12/26/2017. Alberto Ardon M.D.

The physics of ultrasound. Dr Graeme Taylor Guy s & St Thomas NHS Trust

Fig. 1

Ihor TROTS, Andrzej NOWICKI, Marcin LEWANDOWSKI

Ship echo discrimination in HF radar sea-clutter

Lesson 06: Pulse-echo Imaging and Display Modes. These lessons contain 26 slides plus 15 multiple-choice questions.

Assessment of the Acoustic Properties of Common Tissue-mimicking Test Phantoms

Loop-Dipole Antenna Modeling using the FEKO code

Lesson 12: Doppler Principles. This lesson contains 50 slides plus 26 multiple-choice questions.

Ultrasound & Artifacts

Introduction to Ultrasound Physics

Ultrasound-modulated optical tomography of absorbing objects buried in dense tissue-simulating turbid media

EFFECT OF SURFACE COATINGS ON GENERATION OF LASER BASED ULTRASOUND

Acoustic resolution. photoacoustic Doppler velocimetry. in blood-mimicking fluids. Supplementary Information

Sonic Distance Sensors

The Physics of Echo. The Physics of Echo. The Physics of Echo Is there pericardial calcification? 9/30/13

ECHO-CANCELLATION IN A SINGLE-TRANSDUCER ULTRASONIC IMAGING SYSTEM

Lesson 02: Sound Wave Production. This lesson contains 24 slides plus 11 multiple-choice questions.

Chapter 4. Pulse Echo Imaging. where: d = distance v = velocity t = time

Non-Data Aided Doppler Shift Estimation for Underwater Acoustic Communication

Sea Surface Backscatter Distortions of Scanning Radar Altimeter Ocean Wave Measurements

Acoustic Measurements of Tiny Optically Active Bubbles in the Upper Ocean

Medical Imaging. X-rays, CT/CAT scans, Ultrasound, Magnetic Resonance Imaging

New Instrument for Rock Bolt Inspection Using Guided Waves

TIME-FREQUENCY ANALYSIS OF A NOISY ULTRASOUND DOPPLER SIGNAL WITH A 2ND FIGURE EIGHT KERNEL

LASER GENERATION AND DETECTION OF SURFACE ACOUSTIC WAVES

COMPUTER PHANTOMS FOR SIMULATING ULTRASOUND B-MODE AND CFM IMAGES

Experimental Observation of RF Radiation Generated by an Explosively Driven Voltage Generator

Physics of Ultrasound Ultrasound Imaging and Artifacts รศ.นพ.เดโช จ กราพาน ชก ล สาขาหท ยว ทยา, ภาคว ชาอาย รศาสตร คณะแพทยศาสตร ศ ร ราชพยาบาล

ACOUSTO-ULTRASONIC EVALUATION OF HYBRID COMPOSITES USING

MONITORING PHYSIOLOGICAL SIGNALS DURING RUNNING EXERCISE

FPGA-BASED CONTROL SYSTEM OF AN ULTRASONIC PHASED ARRAY

Spectral Distance Amplitude Control for Ultrasonic Inspection of Composite Components

WAVELET-BASED ADAPTIVE DENOISING OF PHONOCARDIOGRAPHIC RECORDS P. Várady 1 1 Department of Control Engineering and Information Technology

Structural UT: Variables Affecting Attenuation and Review of the 2 db per Inch Model

IREAP. MURI 2001 Review. John Rodgers, T. M. Firestone,V. L. Granatstein, M. Walter

Detection of Protective Coating Disbonds in Pipe Using Circumferential Guided Waves

A Comparison of Two Computational Technologies for Digital Pulse Compression

CONTACT LASER ULTRASONIC EVALUATION OF CONSTRUCTION MATERIALS

Attenuation and velocity of ultrasound in solid state materials (transmission)

Ultrasonic Nonlinearity Parameter Analysis Technique for Remaining Life Prediction

Keywords: Ultrasonic Testing (UT), Air-coupled, Contact-free, Bond, Weld, Composites

Calibrating a 90-kHz multibeam sonar

Feasibility Study for ARL Inspection of Ceramic Plates Final Report - Revision: B

Non-Contact Ultrasound Characterization of Paper Substrates

Solar Radar Experiments

Ultrasonic Linear Array Medical Imaging System

Vectrino Micro ADV Comparison

PSEUDO-RANDOM CODE CORRELATOR TIMING ERRORS DUE TO MULTIPLE REFLECTIONS IN TRANSMISSION LINES

Report Documentation Page

ACTIVE SHIELDING IN MEASUREMENTS OF DC NEAR BIOMAGNETIC FIELDS

Proceedings of Meetings on Acoustics

Physics in Modern Medicine Fall 2010

Equipment for Attenuation and velocity of ultrasound in solid state materials (transmission), experimental set-up

Modeling Antennas on Automobiles in the VHF and UHF Frequency Bands, Comparisons of Predictions and Measurements

ANALYSIS OF A PULSED CORONA CIRCUIT

ACOUSTIC MICRO IMAGING ANALYSIS METHODS FOR 3D PACKAGES

ULTRASONIC IMAGING of COPPER MATERIAL USING HARMONIC COMPONENTS

Isolation Scanner. Advanced evaluation of wellbore integrity

Evanescent Acoustic Wave Scattering by Targets and Diffraction by Ripples

Ultrasound Bioinstrumentation. Topic 2 (lecture 3) Beamforming

S. Martel, I. Hunter BioInstrumentation Laboratory, Massachusetts Institute of Technology, Cambridge, MA, USA

NUMERICAL MODELING OF AIR-COUPLED ULTRASOUND WITH EFIT. D. E. Chimenti Center of Nondestructive Evaluation Iowa State University Ames, Iowa, USA

THE INFLUENCE OF THE TRANSDUCER BANDWIDTH AND DOUBLE PULSE TRANSMISSION ON THE ENCODED IMAGING ULTRASOUND

ENHANCEMENT OF SYNTHETIC APERTURE FOCUSING TECHNIQUE (SAFT) BY ADVANCED SIGNAL PROCESSING

Photomultiplier Tube

Doppler in Obstetrics: book by K Nicolaides, G Rizzo, K Hecher. Chapter on Doppler ultrasound: principles and practice by Colin Deane

Introduction To NDT. BY: Omid HEIDARY

Transducer product selector

IB2-1 HIGH AVERAGE POWER TESTS OF A CROSSED-FIELD CLOSING SWITCH>:< Robin J. Harvey and Robert W. Holly

ESME Workbench Enhancements

HEALTH MONITORING OF ROCK BOLTS USING ULTRASONIC GUIDED WAVES

THE MEMORY EFFECT AND PHASE RESPONSE OF MODEL SINOATRIAL NODE CELLS

Optical coherence tomography

PULSED BREAKDOWN CHARACTERISTICS OF HELIUM IN PARTIAL VACUUM IN KHZ RANGE

AN AUTOMATED ALGORITHM FOR SIMULTANEOUSLY DETERMINING ULTRASONIC VELOCITY AND ATTENUATION

Artifacts. Artifacts. Causes. Imaging assumptions. Common terms used to describe US images. Common terms used to describe US images

Practical Considerations for Radiated Immunities Measurement using ETS-Lindgren EMC Probes

Assembly and Experimental Characterization of Fiber Collimators for Low Loss Coupling

1. Introduction. 2. Mobile Ultrasonic Inspection System MUSE

Investigation of a Forward Looking Conformal Broadband Antenna for Airborne Wide Area Surveillance

Investigation of Modulated Laser Techniques for Improved Underwater Imaging

Remote Sediment Property From Chirp Data Collected During ASIAEX

EWGAE 2010 Vienna, 8th to 10th September

REFLECTION AND TRANSMISSION OF LAMB WAVES AT DISCONTINUITY IN PLATE Z. Liu NDT Systems & Services AG, Stutensee, Germany

Transcription:

BEAM DISTORTION IN DOPPLER ULTRASOUND FLOW TEST RIGS: MEASUREMENT USING A STRING PHANTOM R. Steel, P. J. Fish School of Informatics, University of Wales, Bangor, UK Abstract-The tube in flow rigs used for testing Doppler ultrasound instruments can attenuate and distort the beam and sample volume by refraction, reflection, absorption and mode conversion. The attenuation and degree of distortion has been measured by using a moving string test object and candidate tubes have been compared. s of rubber, TFE-Teflon, Perspex, heatshrink and C-Flex have been tested leading to the choice of.8mm wall C-Flex. Keywords- Doppler, ultrasound, test, flow The TMM is normally gelatine or agar based and although tubeless test objects have been built and their geometric stability over periods up to four days studied [,3], their long-term stability is unknown and thus it is usual for the flow channel to be the lumen of a tube separating BMF and TMM. This tube, usually made from a plastic or rubber, will have acoustic characteristics different from BMF and TMM and can distort the instrument s beam and sample volume [4-6]. A different ultrasound propagation speed g I. INTRODUCTION Doppler ultrasound devices are routinely used for the assessment of flow characteristics in patients and for clinical research. They can take the form of a stand-alone instrument or be incorporated into an ultrasound scanner and can be either continuous wave (CW) sensitive to flow within the region of overlap of the beams of transmitter and receiver transducers - or pulsed wave (PW) sensitive to flow within a sample volume defined by the beam width, transmitted pulse duration and received signal gating. Testing these devices as part of a quality control programme is normally carried out by the use of moving string test objects, which simulate single streamlines and can be used to determine spatial resolution (eg. beam width, sample volume size) and flow test objects which simulate flow in a blood vessel []. The general form of a flow test object is a flow channel within a tissue mimicking material (TMM) having an ultrasound propagation speed, absorption and scattering characteristics typical of soft tissue. A blood-mimicking fluid (BMF) having an ultrasound propagation speed, absorption and scattering characteristics similar to blood flows steadily through the channel from an upper to a lower reservoir or under the action of a pulsatile pump (Fig. ). TMM Probe surface BMF Pump Fig.. Flow test object. TMM Tissue mimicking medium; BMF Blood mimicking fluid.

Report Documentation Page Report Date 5 Oct Report Type N/A Dates Covered (from... to) - Title and Subtitle Beam Distortion in Doppler Ultrasound Flow Test Rigs: Measurement Using a Phantom Contract Number Grant Number Program Element Number Author(s) Project Number Task Number Work Unit Number Performing Organization Name(s) and Address(es) School of Informatics University of Wales Bangor, UK Sponsoring/Monitoring Agency Name(s) and Address(es) US Army Research, Development & Standardization Group (UK) PSC 8 Box 5 FPO AE 9499-5 Performing Organization Report Number Sponsor/Monitor s Acronym(s) Sponsor/Monitor s Report Number(s) Distribution/Availability Statement Approved for public release, distribution unlimited Supplementary Notes Papers from 3rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, October 5-8,, held in Istanbul, Turkey. See also ADM35 for entire conference on cd-rom. Abstract Subject Terms Report Classification Classification of Abstract Classification of this page Limitation of Abstract UU Number of Pages 4

Shear Incident compression wave Compression Probe Beam Transmitted compression waves on axis off axis Fig. 3. Effect of mode conversion at wall of hard tube. II. METHOD The effect of different wall material and thickness has been assessed by measuring the sensitivity variation within the beam of a 4MHz continuous wave Doppler instrument using a string phantom with and without a tube present. The relative positions of the Doppler instrument probe, tube and moving string are shown in Fig. 4. The string and tube are within a water bath and the section of tube is mounted in the test-rig such that it can be moved along the string to allow measurements without the tube being in the beam path. For the measurements reported here the beam/vessel angle was 6.5 o and the string (mm rubber O-ring) speed was.6ms -. All measurements were made with the string on the horizontal mid-line of the tube and running parallel to the tube axis. In practice it was found to be more convenient to keep the string in a fixed position and, by means of micromanipulators, to move the Doppler probe and tube together during a measurement. The Doppler signal from the CW instrument together with tube and probe position signals from Probe Beam axis scan Fig. 5. View looking along axis of tube showing relative positions of probe, tube and string for measuring beam sensitivity variation with the beam axis passing through the tube axis (left) and laterally displaced (right). potentiometers coupled to the micro-manipulators were sampled and stored using a data logger coupled to a PC. Plots of the Doppler signal power averaged for s versus string position relative to the beam axis were generated with and without the tube in the beam, for different tubes and with the Doppler beam passing through the tube axis and at number of positions displaced horizontally from the tube axis as illustrated in figure 5. Both the insertion loss (reduction in Doppler signal power resulting from the presence of the tube) and the variation of this loss across the tube are of interest. The latter is important since it is a measure of the degree to which the ultrasound beam has been distorted. In order to assess this more easily, the ratio of the powers at each string position with and without the tube were calculated and plotted to show the fractional change in signal power versus string position. Measurements have been made on the tubes shown in the first column of table. III. RESULTS AND DISCUSSION Sample graphical results [6] for 8mm ID/.6mm wall C-Flex are shown in Figs. 6 and 7. Doppler power versus string position for four beam axis positions across the tube is shown in Fig. 6. The ratio of power measured with the tube in place to that measured without for the cases shown in Fig. 6(a) and (d) is plotted in Fig. 7. These plots have been normalised to a maximum of unity. The insertion losses, with the beam passing through the tube axis and with the beam displaced by.67 of the lumen radius, are shown in table together with the range of insertion loss across the beam in brackets. Fig. 4. Measurement of beam sensitivity variation within a tube.

.5 (a).5 (b).5.5 4 6 8 4 6 4 6 8 4 6.5 (c).5 (d).5.5 4 6 8 4 6 4 6 8 4 6 Fig. 6. Doppler power (arbitrary scale) versus string position. Upper plot without tube, lower plot with tube. 8mm ID,.6mm wall, C-Flex. Beam axis displacement from tube axis (a) mm, (b).9mm, (c).8mm, (d).7mm. (a) (b).9.9.8.8 ratio/max. ratio.7.6.4 ratio/max. ratio.7.6.4.3.3.... 6 6.5 7 7.5 8 4 4.5 5 5.5 6 Fig. 7. ratio plots normalised to a maximum of unity. - 8mm ID,.6mm wall, C-Flex. Beam axis displacement from tube axis (a) mm, (b).7mm.

TABLE TUBE DIMENSIONS AND INSERTION LOSS I.D.(mm) Wall(mm) Insertion loss (db) Beam centred Beam off-axis Rubber 7.94.58 9.(.).4(3.3) Thin-wall C-Flex 8..8 4.(.) 5.5(.4) Thick-wall C-Flex 7.94.58 8.4(.9) (3.) TFE-Teflon 7.98. 4.3(.4) 7.(.7) Heatshrink..7 4.(.) 7.(3.) Perspex.. (.4) - The measurements were taken at the string position giving the greatest Doppler power without the tube. The distortion of the beam by the tube may mean that this is not the position of greatest Doppler power with the tube in place. Estimated error in insertion loss db. The figures in brackets give the range of insertion loss across the beam. The off-axis measurements are for a beam axis displaced by.67 of the tube radius. Even though there is a significant insertion loss with the tube in place (Fig. 6 and Table ), since the beam is relatively narrow (Fig.6) compared with the tube, the variation of loss across the tube is small when the beam is centred (Fig. 7a and Table ). As the beam is moved towards the side of the tube the loss - primarily as a result of absorption in this relatively soft material [6]- becomes more pronounced in the part of the beam closer to the side of the tube (Fig. 7b and Table ). The first three tubes in Table are of relatively soft materials, reasonably well impedance-matched to water [6]. The insertion losses for the two examples of C-Flex are approximately in the same ratio as the wall thickness as would be expected if the loss is dominated by absorption. TFE-Teflon is less well matched and is more highly absorbing and has a higher insertion loss at a lower wall thickness [6]. Heatshrink has been included as an example of a material that has been used for flow phantoms since it combines a thin wall with structural stability. However, even with this relatively large diameter tube the range of insertion loss across the offaxis beam is high, probably as a result of more complex beam interference effects resulting in turn from mode conversion and low critical angle. The insertion loss in the case of Perspex for the off-axis beam was too high for measurements to be made. Of the tubes measured the thin-walled C-Flex was clearly the most suitable for a Doppler flow phantom, having a low insertion loss and, probably more importantly, a low range of insertion loss across the tube. [] K.V. Ramnarine, T. Anderson, and P.R. Hoskins, Construction and geometric stability of physiological flow rate wall-less stenosis phantoms, Ultrasound Med. Biol., vol. 7, pp. 45-5,. [3] D.W. Rickey, P.A. Picot, D.A. Christopher and A.A. Fenster, A wall-less phantom for Doppler ultrasound studies, Ultrasound Med. Biol., vol., pp. 63-76, 995. [4] R.S. Thompson and G.K. Aldis, Effect of a cylindrical refracting interface on ultrasound intensity and the CW Doppler spectrum, IEEE Trans.Biomed. Eng., vol. 43, pp. 45-459, 996. [5] R.S. Thompson, G.K. Aldis, and I.W. Linnett, Doppler ultrasound spectral power density distribution: Measurement artefacts in steady flow, Med.Biol.Eng.Comput., vol. 8, pp. 6-66, 99. [6] R. Steel, An experimental and theoretical investigation of the wall-effect in Doppler ultrasound flow phantoms, 998. University of Wales. PhD. [7] R.S. Thompson, P. Tortoli, and G.K. Aldis, Selective transmission of a focused Doppler ultrasound beam through a plastic layer, Ultrasound Med.Biol., vol. 6, pp. 333-346,. IV. CONCLUSION The degree to which the tube in a Doppler flow phantom can attenuate and distort the beam of an ultrasonic flow detector is important when selecting tubes for such a device. A simple CW Doppler flow detector may be used to determine the insertion loss of the tube at a range of positions of the beam relative to the tube axis and assist in the choice of tube. REFERENCES [] P.R. Hoskins, S.B. Sherriff, and J.A. Evans, Testing of Doppler Ultrasound Equipmen. York: Institute of Physical Sciences in Medicine, 994.