HELUKABEL UL-LISTED CABLES

Similar documents
ÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables

Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded. Complete the Installation. SKINTOP Strain Relief page 488

OLFLEX. Flexible Tray Cable MARYLAND METRICS. LAPP products are available from

THHN12STGN500 THHN 12 STR Green 500

THHN2BK2500 THHN 2 STR Black 2500

14 AWG 2 AWG: 600 Volt

THHN6WH500 THHN 6 STR White 500. Features Conductor Size Current Rating 55 AMPERE (60 DEG C), 65 AMPERE (75 DEG C), 75 AMPERE (90 DEG C)

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

THHN12S0LWHBL500 THHN 12 Sol White/Blue Striped 500

Cable Solutions for Servo and Variable Frequency Drives (VFD)

CIR (Crush & Impact Resistant) VFD Power Cable

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

MachFlex Industrial Cables

Instrumentation Cables

SIMpull THHN, it slips and slides - all with NoLube.

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments

CCW Continuously Corrugated Welded Cable ARMORED CABLE FOR HAZARDOUS LOCATIONS

1 Exam Prep NFPA 70: National Electric Code 2011 Tabs and Highlights

SECTION BUILDING WIRE AND CABLE

Industrial Data. Conductor (stranding) Diameter Nom. DCR. Shielding Materials Nom. DCR. Color Code. (2)18 AWG TC Data Pair:

Lutze Inc. Flexible Control Cables USA Selection Guide V. 2.6

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

Inclinometer Selection Guide

Conductors and Raceway Design

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

How big is China s Digital Economy

SUBMITTAL COVER SHEET

SCXI High-Voltage Terminal Block

Frame through-beam sensors

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

BX /2 Solid Ac/BX Aluminum Cable

AEE. Canada. Australia

ÖLFLEX 409 P. Heavy duty control cable with PUR jacket

The STrongeST Link to your SucceSS... From ViSion to FiniShed ProducT

IMSA TRAFFIC SIGNAL CABLE

Industrial Data Solutions Industrial Data DeviceBus for ODVA DeviceNet Cables

Power-limited Circuit Cable. Features & Applications: Specification. Power-limited Circuit Cable

Through-beam ring sensors

Article 700: Emergency Systems. 2.! Audible and visual signal devices shall be provided, where practicable to indicate.

SECTION ELECTRICAL IDENTIFICATION

Product Index. 1 Copper Building Wire Products Flexiloy Aluminum Wire and Cable Products Power and Control Tray Cable Products 31 39

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE

Low Voltage AIRGUARD. A proven, rugged product for harsh environments

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9211E 4-Channel Thermocouple Input Module

RADIO AND TELEVISION SATELLITE EQUIPMENT

Wisconsin Contractors Institute Continuing Education

METAL CLAD WIRING SYSTEM

SCXI High-Voltage Terminal Block

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

Communication, Control, and Industrial Cable

SKINTOP ÖLFLEX CLICK & VFD CLICK FLEX. Products for Variable Frequency Drive Applications. ake the right connection

CUSTOM INNOVATIONS CONNECTOR + CABLE

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature

A. Product Description: Stranded conductor insulated wire.

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9853E 2-Port, High-Speed CAN Module

3-10. General Quick Selection Introduction 3-Cordsets PannelConnect Safety. Connection. Network Media

Installation Solutions. Cable assemblies according to SIEMENS 6FX standard

DLO Flexible Power Cable

INTRODUCTION PRODUCT LINES GREEN ENERGY. In drive technology, the trend is towards ever more complex

St. Monica Food Pantry Low Voltage (600V and less) Conductors and Cables sys-tek No

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9207E 16-Channel, ±20 ma/±10 V, 24-Bit Analog Input Module

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS

Part VIII Electrical GENERAL REQUIREMENTS CHAPTER 33

OVERVIEW THE INDONESIA TEXTILE INDUSTRY

FP-RLY-420. Features. Installing the FP-RLY-420. FieldPoint Operating Instructions. Eight-Channel SPST Relay Module

600 Volt MULTICONDUCTOR EPR MC Low Voltage Commercial & Industrial Cables

A. Product Data: For each electrical identification product indicated.

HARTING Han-Power T Solutions

NOTICE OF RULE MAKING PROCEEDINGS AND PUBLIC HEARING

Code Check Electrical is a field guide to common code issues in residential

Table of contents. Phone: Fax:

CONTINUING EDUC ATION

KAL-K. Electronic Flow Monitor. for liquids. Range: approx cm/s. p max : 100 bar. Temperature of medium: C Option: 0...

NGR. Guided Wave Radar Level Transmitter

Creating the world technology leader in surface solutions under one roof

OKONITE CABLES STOCK CATALOG In Stock for Immediate Delivery

IST 25. Impulse Sparktester (Dry Testing Unit) for the Insulation Test in Extrusion and Winding Processes. Complies with MIL and NEMA.

Servo Cable Selection

GLOSSARY OF ELECTRICAL INDUSTRY TERMS

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature

TIGER BRAND MINING CABLES

SECTION Q WIRE AND CABLE Wilson Avenue, Toronto, Ontario, Canada, M9M 1A1 Ph: Fax:

Medium Voltage Power Cables

EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)

MIM. Electromagnetic Flowmeter. Compact, All-metal Design

NEC 2014 Code Changes

Wiring Methods, Components, and Equipment for General Use -- OSHA Standard

Republic Wire Inc. Our Raw Materials Make A Quality Difference. Diversity Of Products Meets Customer Needs

High Temperature Flexible Control Cable OLFLEX

600 Volt MULTICONDUCTOR XLPE MC Low Voltage Commercial & Industrial Cables

Transcription:

Industrial Cables

HELUKABEL UL-LISTED CABLES Flexible = F High Flex = HF Chemical Res Sun Res Oil Res Temperature ( C) Voltage (V) Class / Group Flame Test Temperature ( C) Voltage (V) Flame Tested Standard CABLE + Multi Conductor Technical Properties TRAYCONTROL 300 CM X 300 105 FT 4 I / II 300 105 X (II) X F TRAYCONTROL 500 2277 X 1000 90 FT 4 I / II 1000 90 X (II) X F TRAYCONTROL 530 2277 X 1000 90 FT 4 I / II 1000 90 X (II) X F TRAYCONTROL 600 2277 X 1000 90 FT 4 I / II 1000 90 X (I) X X F TRAYCONTROL 670 HDP 2277 X 1000 105 FT 4 I / II 1000 105 X (II) X X F JZ-604 TC 1277 X 600 90 FT 4 I / II 600 90 X (II) X X F MULTIFLEX 600 2277 X 1000 90 FT 4 I / II 1000 90 X (II) X X HF TOPFLEX 600 VFD 2277 X 1000 90 FT 4 I / II 1000 90 X (II) X X F TOPFLEX 620 VFD 2277 X 1000 90 FT 4 I / II 1000 90 X (II) X X F TOPFLEX 650 VFD 2277 X 1000 105 FT 4 I / II 1000 105 X (II) X X F TOPFLEX 1000 VFD 2277 X 1000 90 FT 4 I / II 1000 90 X (II) X X F TOPSERV 600 VFD 2277 X 1000 105 FT 4 I / II 1000 105 X (II) X HF TOPSERV 650 VFD 2277 X 1000 105 FT 4 I / II 1000 105 X (II) X HF HELUKAT 155 UL 444 75 FT 1 75 HELUKAT 200 UL 444 75 FT 1 75 F HELUKAT 300 UL 444 75 FT 1 75 F PROFInet Type A CMG* 600* 75 FT 4 600* 75* X X PROFInet Type B CMG* 75 FT 4 600* 75* X X F PROFInet Type C CMX* X 75 FT 1 75 X X HF Profibus L2 Torsion + Festoon 444* 75* FT 4* 75* X* X* F+HF* Profibus SK CMG* 600* 75* FT 4* 600* 75* X* X* F+HF* DeviceNet CMG* 75* FT 4* 75* X* X* F+HF* Single Conductor UL-Style 1015 1015 X 600 105 FT 1 I 600 105 F FIVENORM 1063 X 600 105 FT 1 I 600 105 F THHN/THWN 1408 X 600 90 FT 1 I 600 90 X X X * - Construction Dependent X - Passes Test; X (I) - Oil Res I; X (II) - Oil Res II UL-listed Cables: UL-listed cables are suitable to the factory wiring of electrical equipment and machinery, as well as for field wiring on site. UL-isted cables already have approval for use, i.e. confirmed compliance with applicable safety regulations by UL standards. The construction must no longer be verified in the field.

HIGH FLEX, POWER APPLICATION UL cable marked flexing cul or CSA cable marked flexing New for NFPA 2012* New for NFPA 2012* UR AWM-type cable for flexing application or cable track cur or CSA-type cable for flexing application or cable track TC-ER, TC, MTW, THHN CLOSED CABLE TRAY TC, TEW, CIC HAZARDOUS LOCATION CONTROL APPLICATION Cable suitable for use in hazardous location. Attention: Cable selection depends on the area classification CMG, CM, CMX, ITC, PLTC CMG, CM, CIC, CMX

FIXED, POWER APPLICATION TC-ER TC New for NFPA 2012* New for NFPA 2012* UR AWM cable for flexing application + conduit listed (ex. LFNC) UR AWM cable for flexing application + conduit listed (ex. LFNC) INDUSTRIAL CONTROL PANEL Single conductor, AWM cable UL-Style 1015 Single conductor, MTW cable Single conductor, AWM cable UL-Style 1015 Single conductor, TEW cable IN-FLOOR CABLE TRAY OPEN CABLE TRAY TC-type cable marked Dir Bur (Direct Burial) TC-type cable marked Dir Bur (Direct Burial) TC-ER TC TC-type cable inside raceway listed for direct burial TC-type cable inside raceway listed for direct burial * ur & cur cable will comply with clause 12.9 of NFPA79

HELUKABEL UL-RECOGNIZED CABLES Flexible = F High Flex = HF Chemical Res Sun Res Oil Res Temperature ( C) Voltage (V) Class / Group Flame Test Temperature ( C) Voltage (V) Flame Tested Style CABLE + Technical Properties JZ-602 2587 X 600 90 FT 1 I/II A/B 600 90 X X F JZ-602 RC 20939 X 600 80 FT 1 I/II A/B 600 80 X X X HF JZ-603 2587 X 600 90 FT 1 I/II A/B 600 90 X X F MEGAFLEX 500 20939 X 600 80 FT 1 I/II A/B 600 80 X X X F MEGAFLEX 600 20234 X 1000 80 FT 1 I/II A/B 1000 80 X X X F COMMAND CABLE UL 2464 X 300 80 FT 1 I/II A/B 300 80 X X F MULTISPEED 500-PVC 21179 X 600 80 FT 1 I/II A/B 600 80 X X HF SUPERTRONIC-310-PVC 2464 X 300 80 FT 1 I/II A/B 300 80 X X HF MULTISPEED TRONIC-PUR 20233 X 300 80 FT 1 I/II A/B 300 80 X X X HF TOPSERV 108 PVC 2570 X 1000 80 FT 1 I/II A/B 1000 80 X X F TOPGEBER 511 PVC 20233 X 300 80 FT 1 I/II A/B 300 80 X X F TOPSERV Hybrid 21223 X 1000 80 FT 1 I/II A/B 1000 80 X X X HF X - Passes Test Note: The above UL-recognized cables are an abridged list. For a complete list of UL-recognized cables, please reference the Cables & Wires catalog or contact a local HELUKABEL representative. RECOGNIZED CABLES The products included in this category are intended as factory-installed or factory-provided components of complete equipment submitted for approval, rather than for direct separate installation in the field. The final acceptance of the component depends on its installation and use in or with complete equipment submitted to authorities having jurisdiction (AHJ). Recognized cables type AWM are regulated by clause 12.9 of NFPA79 2012. HELUKABEL UL/CSA CABLE ACCESSORIES PRODUCTS CABLE GLAND/ CONDUIT CONNECTOR UR UL CSA HELUTOP HT Series*** X X** HSK Series X X X** T&B Series X X LT Series X X X - Passes Test ** - Model Dependent ***- MFDE and MS-E models are not certified TUBING/CONDUIT UR UL CSA HELUcond PA6 X Anaconda Sealtite HTDL X X Anaconda Sealtite CNP X X LFNC-A CABLE TIE UR UL CSA E Series X Q-tie X TY-Rap X TYH X TYZ X Type T X Type W X

/ STANDARD REFERENCE FOR CABLE UL 508A Industrial Control Panel Clause 28: Field wiring Clause 29: Internal wiring NFPA79-2007 Industrial Machinery Chapter 12: Conductors, Cables and Flexible Cords 12.7 Conductors and cables used for flexing application NEW FOR NFPA79-2012 12.9 Special cables and conductors NEC 2011 Art. 310 Conductors for General Wiring Art. 320 Armored Cable : Type AC Art. 324 Flat-Conductor Cable: Type FCC Art. 328 Medium Voltage Cable: Type MV Art. 330 Metal-Clad Cable: Type MC Art. 332 Mineral-Insulated, Metal-Sheated Cable: Type MI Art. 336 Power and Control Tray Cable: Type TC Art. 340 Underground Feeder and Branch-Circuit Cable: Type UF Art. 344 Rigid Metal Conduit Art. 348 Flexible Metal Conduit Art. 350 Liquid-Tight Flexible Metal Conduit (LFMC) Art. 356 Liquid-Tight Flexible Non-Metallic Conduit (LFNC) Art. 358 Electrical Metallic Tubing: Type EMT Art. 376 Metal Wireways Art. 390 Underfloor Raceways Art. 392 Cable Trays Art. 400 Flexible Cords and Cables Art. 409 Industrial Control Panels Art. 500 Hazardous (Classified) Location, Classes I, II, III, Division 1 and 2 Art. 522 Control Systems for Permanent Amusement Attractions Art. 610 Crane and Hoist Art. 645 Information Technology Equipment Art. 670 Industrial Machinery Art. 725 Class 1, Class 2, and Class 3 Remote-Control, Signaling, and Power.Limited Circuits Art. 727 Instrumentation Tray Cable: Type ITC Art. 770 Optical Fiber Cables and Raceways Art. 800 Communication Circuits (CEC 2012) Section 4 Conductors Section 12 Wiring methods 12-100 Conductors 12-600 Armored cable 12-800 Flat conductor cable Type FCC 12-900 Raceways 12-1000 Rigid and flexible metal conduit 12-1300 Liquid-tight flexible conduit 12-1400 Electrical metallic tubing 12-1600 Surface raceways 12-1700 Underfloor raceways 12-2100 Wireways 12-2200 Cable trays 12-2250 Cablebus 12-3000 Installation of boxes, cabinets, outlets and terminal fittings Section 16 Class 1 and Class 2 circuit Section 18 Hazardous locations Section 34 Sign and outline lighting Section 54 Community antenna distribution and radio and television installations Section 56 Optical fiber cables Section 60 Electrical communication system Section 64 Renewable energy system Section 66 Amusement parks, midways, carnivals, film and TV sets, remote TV broadcasting location, and travelling system

HELUKABEL UL-LISTED CABLES CE AWM CIC TEW TC CMG CM CMX HAZ LOC AWM MTW FLEXING DIR BUR ITC/PLTC TC-ER CABLE + Multi Conductor Ratings TRAYCONTROL 300 X X X** X X X X X TRAYCONTROL 500 X X** X X X X X X X X X TRAYCONTROL 530 X X** X X X X X X X X X TRAYCONTROL 600 X X** X X X X X X X X X TRAYCONTROL 670 HDP X X** X X X X X X X X X JZ-604 TC X X X X X X X X MULTIFLEX 600 X X** X X X X X X X X X TOPFLEX 600 VFD X X** X X X X X X X X X TOPFLEX 620 VFD X X** X X X X X X X X X TOPFLEX 650 VFD X X** X X X X X X X X X TOPFLEX 1000 VFD X X** X X X X X X X X X TOPSERV 600 VFD X X** X X X X X X X X X TOPSERV 650 VFD X X** X X X X X X X X X HELUKAT 155 UL X X HELUKAT 200 UL X X HELUKAT 300 UL X X PROFInet Type A X* X X* X PROFInet Type B X* X X X* X* X* X PROFInet Type C X X X Profibus L2 Torsion + Festoon X X X* X* X Profibus SK X X X X X* X DeviceNet X* X X X X Single Conductor UL-Style 1015 X X X X X X FIVENORM X X X X X X THHN/THWN X X X X X - Passes Test * - Construction Dependent ** - Location Dependent HELUKABEL 1201 Wesemann Dr. West Dundee, IL 60118 Phone: 847-930-5118 Fax: 847-622-8766 sales@helukabel.com www.helukabel.com HELUKABEL Canada 3620B Laird Rd., #4 Mississauga, ON L5L 5Z7 Phone: 289-444-5040 Fax: 289-444-5041 sales@helukabel.ca www.helukabel.ca HELUKABEL branches: Belgium Czech Republic France Germany Italy Netherlands Poland Russia Sweden Switzerland Turkey UK China India Malaysia Singapore South Korea Thailand Indonesia UAE South Africa WM/UL-CSA/11-2013/1500/US-CA/WD

/ ACRONYMS AND DEFINITIONS TC: Tray Cable, suitable for cable tray (Art. 336 NEC, Sec. 12 CEC, Table 19 CEC) ER: Exposed Run, suitable for exposed installation (180 cm for, 30 cm for Canada, refers to TC cable) ITC: Instrumentation Tray Cable, for use only in industrial environments (Art. 727 NEC) PLTC: Power-Limited Tray Cable (Art. 725 NEC) DIR BUR: Direct Burial, suitable for direct burial in the ground MTW: Machine Tool Wire AWM: Appliance Wiring Materials HAZ LOC: Hazardous Location (Art. 500 NEC, Sec. 18 CEC) CMX: Communications cable, limited use (Art. 800 NEC, Sec. 60 CEC, Table 19 CEC) CM: Communications cable, general-purpose (Art. 800 NEC, Sec. 60 CEC, Table 19 CEC) CMG: Communications cable, general-purpose (Art. 800 NEC, Sec. 60 CEC, Table 19 CEC) TEW: Thermoplastic-Insulated Equipment Wire CIC: Control and Instrumentation Cable, non-armored (Table 19 CEC) THHN: Thermoplastic-Insulated Wire, indicates a single conductor having flame-retardant and heat-resistant thermoplastic insulation with a jacket of extruded nylon or equivalent material. The wire is rated 90 C dry only. THWN: Thermoplastic-Insulated Wire, indicates a single conductor having flame-retardant, moisture- and heat-resistant thermoplastic insulation with a jacket of extruded nylon or equivalent material. The wire is rated 75 C wet or dry. LFNC: Liquid-Tight Flexible Nonmetallic Conduit (Art. 356 NEC) STYLE: Defines a family of conductors with certain ratings. FLAME RATING: Wire: - H (Horizontal flame: internal wire) - V (Vertical flame: external wire) Cable: - Cable flame test 1061 of UL 1581 - FT 1 (Vertical flame), test in accordance with Section 1060 of UL 1581 - FT 4 (Vertical flame), test in accordance with UL 1685 CLASS: - I (internal wiring) - II (external wiring) GROUP : Crushing resistance - A (not evaluated: internal wire) - B (Evaluated: external wire) Developed in collaboration with www.aceconsulting.it Subject to technical alternations