THHN12S0LWHBL500 THHN 12 Sol White/Blue Striped 500

Similar documents
Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

THHN12STGN500 THHN 12 STR Green 500

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

THHN2BK2500 THHN 2 STR Black 2500

THHN6WH500 THHN 6 STR White 500. Features Conductor Size Current Rating 55 AMPERE (60 DEG C), 65 AMPERE (75 DEG C), 75 AMPERE (90 DEG C)

SIMpull THHN, it slips and slides - all with NoLube.

SUBMITTAL COVER SHEET

BX /2 Solid Ac/BX Aluminum Cable

The STrongeST Link to your SucceSS... From ViSion to FiniShed ProducT

Republic Wire Inc. Our Raw Materials Make A Quality Difference. Diversity Of Products Meets Customer Needs

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables

Product Index. 1 Copper Building Wire Products Flexiloy Aluminum Wire and Cable Products Power and Control Tray Cable Products 31 39

Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded. Complete the Installation. SKINTOP Strain Relief page 488

CIR (Crush & Impact Resistant) VFD Power Cable

ÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

QSLVM2500 QSLV-M Cold Shrink Insulator

Electrical submittal no data received July 1, 2015 has been reviewed by this office with the following disposition:

GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry

Instrumentation Cables

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

WIRE AND CABLE SECTION M WIRE AND CABLE. TEW / TEWN and TR-64 Wire. SPT1 / SPT2 / SEW1 AND SEW2 Wire. SVT / SJT / SO AND SOOW Cords

St. Monica Food Pantry Low Voltage (600V and less) Conductors and Cables sys-tek No

OLFLEX. Flexible Tray Cable MARYLAND METRICS. LAPP products are available from

Wire Gauge Chart. Cigar Lighter 10 to 12. Dome Light 1. Radio 2 to 4. Gauges 0.7 to 1. Instrument Lights 1.5 to 3

CP CABLE. SPECIFICATIONS: 1. CONDUCTOR: Bare, soft drawn copper, Class B stranding per ASTM B INSULATION: High molecular weight polyethylene.

SECTION Q WIRE AND CABLE Wilson Avenue, Toronto, Ontario, Canada, M9M 1A1 Ph: Fax:

14 AWG 2 AWG: 600 Volt

TIGER BRAND MINING CABLES

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

T S 15KVA 1PH 240/480 Transformer

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments

Part VIII Electrical GENERAL REQUIREMENTS CHAPTER 33

IMSA TRAFFIC SIGNAL CABLE

GEXOL WORLD CLASS OIL & GAS CABLES

600 Volt MULTICONDUCTOR XLPE MC Low Voltage Commercial & Industrial Cables

Low Voltage AIRGUARD. A proven, rugged product for harsh environments

For tough, seaworthy wire

SKINTOP ÖLFLEX CLICK & VFD CLICK FLEX. Products for Variable Frequency Drive Applications. ake the right connection

Lutze Inc. Flexible Control Cables USA Selection Guide V. 2.6

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

SECTION BUILDING WIRE AND CABLE

600 Volt MULTICONDUCTOR EPR MC Low Voltage Commercial & Industrial Cables

HOOK-UP WIRE A STYLE TO SUIT ANY NEED

DLO Flexible Power Cable

A. Product Description: Stranded conductor insulated wire.

EcoCable and EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.

EcoCable and EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded (CCW) Type Cables*)

3M Scotchlok Insulated Electrical Spring Connector B (Blue)

31375 Aqua-Gel Ii, 5-Gal Bucket

Continuous Flex Data Cable

EcoCable and EcoFlex Cable. Smaller. Lighter. 100% Recyclable.

Model Color Wire Combination Range Wire Combination Range (mm) Quantity Cat. No. Box of V. Carton of 1, Gray.

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

FSK1VDRA 1G Al DPLX RCPT CVR

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded Type Cables*)

MEDIUM VOLTAGE

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.

OKONITE CABLES STOCK CATALOG In Stock for Immediate Delivery

EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)

HELUKABEL UL-LISTED CABLES

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

TRANSMITTAL LETTER. As Builts Change Order Contract Copy of Letter Insurance. For approval Approved as submitted Resubmit copies for approval

Ideal. Ergonomic, Cushion-Grip, Vinyl Coated

Description Cast Device Box, Height Inch; Width 2.81 Inch; Depth 2.69 Inch; Capacity 25 Cu Inch; 1 Gang; 2 Hub(S); Hub Location End;

5-35kV 1/C EPR MV-105 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables

Detailed Specifications & Technical Data

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.

2. CONDUCTORS. 2.1 Strand Types. 2.2 Coatings Tensile Strength of Copper Wire Copper Strand Properties. 2.5 Aluminum Strand Properties


VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

Airport Cables & Connectors

Standards Update Notice (SUN) Issued: June 6, 2017

INSIDE COILPAKS ALUMINUM MC CABLE THHN COLORED FEEDERS CONDUIT XHHW COLORED FEEDERS PARALLELING OPTIONS INDUSTRIAL CABLE. SOUTHWIRE SIMpull SOLUTIONS

Success Depends on the Crimp

High Temperature Flexible Control Cable OLFLEX

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature

LED7DMR16D W MR16 2PIN 3000K Dimm 12V

CCW Continuously Corrugated Welded Cable ARMORED CABLE FOR HAZARDOUS LOCATIONS

2WT Tu-Wire 120V 32W T8 Ballast

Mongoose PT Platform Shale Shaker

Over 35 Years of Service. Our Commitment. Dedicated to Our Customers. Product Expertise and Specialized Services. Strategic Partnerships

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

AEE. Canada. Australia

Shielded Fire Alarm Cables

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Hendrix Tap, Tie & Ground Wire

C0ND112G 1-1/2" Gray PVC CTD Cond STL RGD

DB EN valid from: Application SERVO LK SMS FX8PLUS SIGNAL

POSEIDON SCIENTIFIC INSTRUMENTS PTY LTD 17 QUEEN VICTORIA ST, FREMANTLE WA PHONE (08) FAX (08) CAB-0XXX (SALEM CODE)

MASTER CATALOG TABLE OF CONTENTS

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Communication, Control, and Industrial Cable

Crimping and Cutting Tool for Connectors, Accommodates wire. From No. 10 to 22 Awg CRIMPING/CUTTING TOOL FOR CONNECTORS. from No.

TE Connectivity Wire Connectors

a) Determine the smallest, standard-sized circuit breaker that should be used to protect this branch circuit.

Transcription:

3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THHN12S0LWHBL500 THHN 12 Sol White/Blue Striped 500 Southwire Company Catalog Number Manufacturer Description Weight per unit Product Category Features Conductor Size Current Rating Stranding Voltage Rating Material, Color, and Finish Insulation Color Insulation Material Jacket Material Dimensions and Weight Length Length in ft Outer Diameter THHN12S0LWHBL500 Southwire Company Cable, THHN, THWN, Awm Type; 500 FT; 119 Mil Outer Diameter; Annealed Copper Conductor Material; Ul 83/758/1063/1581, Ul (Canada and Us), Csa C22.2 Approval; 600 V Voltage Rating; 20 Ampere Current Rating; 90 Deg C Temperature Rating 0.0200 (lbs/ft) THHN-T90-Sol (Solid) 12 AWG 20 AMPERE SOLID 600 V WHITE WITH BLUE STRIPE PVC NYLON 500 FT 500 W 119 MIL Descriptions Additional Information RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70 Commodity Description COPPER BUILDING WIRE-THHN-T90-SOL Description THHN 12 SOL WHITE/BLUE STRIPED 500 Long Description CABLE, THHN, THWN, AWM TYPE; 500 FT; 119 MIL OUTER DIAMETER; ANNEALED COPPER CONDUCTOR MATERIAL; UL 83/758/1063/1581, UL (CANADA AND US), CSA C22.2 APPROVAL; 600 V VOLTAGE RATING; 20 AMPERE CURRENT RATING; 90 DEG C TEMPERATURE RATING Product Type Cable Manufacturer Information Brand Copper GTIN 00032886878909 Manufacturers Part Number 61141002 UPC 032886878909

3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Taxonomies, Classifications, and Categories Category Description THHN12 & THHN14 STR & SOL Type THHN, THWN, AWM Availability minimum qty 500 Packaging Carton 2000 Package Type SPOOL Weight 23 LB/MFT Weight Per foot 0.02 Uses, Certifications, and Standards Approval UL 83/758/1063/1581, UL (Canada and US), CSA C22.2 Temperature Rating 90 DEG C

SIMpull THHN THWN 600 Volts. Copper Conductor Thermoplastic Insulation/ SIM Nylon Sheath Heat, Moisture, Gasoline, and Oil Resistant II Also Rated MTW and THWN-2 SIM Technology for Easier Pulling APPLICATIONS Southwire SIMpull THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 volts. SIMpull THHN conductors are designed to be used without application of pulling lubricant. Allowable temperatures are as follows: THHN or T90 Nylon- Dry locations not to exceed 90 C THWN-2- Wet or dry locations not to exceed 90 C or locations not to exceed 75 C when exposed to oil TWN75- Wet locations not to exceed 75 C MTW- Wet locations or when exposed to oil at temperatures not to exceed 60 C or dry locations not to exceed 90 C (with ampacity limited to that for 75 C conductor temperature per NFPA 79) AWM- Dry locations not to exceed 105 C when rated and used as appliance wiring material SPECIFICATIONS Southwire SIMpull THHN or THWN-2 or MTW (also AWM) comply with: ASTM - B3, B8 (7,19, 37, 61 Strands), B 787 (19 Wire Combination Unilay Strand) UL Standard 83, 1581, and 1063(MTW) T90 Nylon/TWN75 sizes through 1000 kcmil CSA C22.2 No. 75 NOM-ANCE 90 C Federal Specification A-A-59544 National Electrical Code, NFPA 70 VW-1 - Sizes 14 through 1 AWG CT rated in sizes 1/0 AWG and larger FT1 AWM - Sizes 14 through 6 AWG. MTW available in stranded only NEMA WC-70 Construction Requirements RoHS/REACH Compliant Construction Southwire SIMpull THHN or THWN-2 or MTW copper conductors are soft annealed copper. #14-4/0 AWG uses a combination unilay strand and 250 kcmil and larger uses a compressed copper strand. The wire is insulated with a tough heat and moisture resistant poly vinyl chloride (PVC), over which a SIM (SLIKQWIK Infused Membrane) nylon (polyamide) or UL Recognized equal jacket is applied. Available in black, white, red, blue, purple, green, yellow, orange, brown and gray. Some colors are subject to economic order quantity.marked sunlight resistant in sizes 2 AWG and larger. THWN-2 available in sizes 8 AWG and larger. Sizes 14-10 AWG are available with SIMpull Technology only in SIMpull Barrel or CoilPAK configurations. Mon Oct 13 14:41:19 EDT 2014 Page 1 of 3

SIMpull THHN Conductor Size (AWG or kcmil) Number of Strands InsulationJacket Nominal Thickness ThicknessO.D. (mils) (mils) (mils) Approx. Allowable Ampacities+ Weight 60º C 75º C 90º C Standard per 1000' Package (lbs) 14* 1 15 4 102 15 15 15 15 AC 12* 1 15 4 119 23 20 20 20 AC 10* 1 20 4 150 36 30 30 30 AC 14* 19 15 4 109 16 15 15 15 AC 12* 19 15 4 128 24 20 20 20 AC 10* 19 20 4 161 38 30 30 30 AC 8 19 30 5 213 63 40 50 55 ABCD 6 19 30 5 249 95 55 65 75 ABCD 4 19 40 6 318 152 70 85 100 ABCD 3 19 40 6 346 189 85 100 115 ABCD 2 19 40 6 378 234 95 115 130 ABCD 1 19 50 7 435 299 110 130 145 ABCD 1/0 19 50 7 474 372 125 150 170 ABCD 2/0 19 50 7 518 462 145 175 195 ABCD 3/0 19 50 7 568 575 165 200 225 ABCD 4/0 19 50 7 624 718 195 230 260 ABCD 250 37 60 8 694 851 215 255 290 ABCD 300 37 60 8 747 1012 240 285 320 ABC 350 37 60 8 797 1174 260 310 350 ABC 400 37 60 8 842 1334 280 335 380 ABC 500 37 60 8 926 1655 320 380 430 ABCD 600 61 70 9 1024 1987 350 420 475 ABC 750 61 70 9 1126 2464 400 475 535 BC 1000 61 70 9 1275 3257 455 545 615 C * Sizes 14-10 AWG available with patented Sim Technology No Lube jacket only in SIMpull Wire Barrel or CoilPAK configurations. +Allowable ampacities shown are for general use as specified by the 2011 Edition Standard Package: A - 2500' Reel B - 1000' Reel Mon Oct 13 14:41:19 EDT 2014 Page 2 of 3

SIMpull THHN of the National Electrical Code Section C - 500' Spool 310.15 and 240.4(D). Unless the equipment is marked for use at higher D - 5000' Reel temperatures the conductor shall be limited to the following per NEC 110.14(C). 60 C - When terminated to equipment for circuits rated 100 ampers or less or marked for 14-1 AWG conductors. 75 C - When terminated to equipment for circuits rated over 100 ampers or marked for conductors larger than1 AWG. 90 C - THHN dry locations and THWN wet or dry locations for ampacity adjustment purposes using NEC section 310.15. Mon Oct 13 14:41:19 EDT 2014 Page 3 of 3