INSTALLATION GUIDE FOR FLOOR AND ROOF FRAMING

Similar documents

INSTALLATION GUIDE FOR FLOOR AND ROOF FRAMING

WARNING: JOISTS ARE UNSTABLE UNTIL BRACED LATERALLY BRACING INCLUDES:

FRAMING DETAILS FOR FLOOR AND ROOF

Featuring TJ Rim Board and TimberStrand LSL

TRUS JOIST RIM BOARD. Featuring TJ Rim Board and TimberStrand LSL. Multiple thicknesses, grades, and products to cover all your rim board needs

TJI 110, TJI 210, TJI 230,

TJI 210 TJI TJI 360 TJI 560 JOISTS

RAPID RIVER RUSTIC, INC.

VERSA-LAM BCI INSTALLATION GUIDE LIMIT STATES DESIGN CANADA

Introducing AJSTM INSTALLATION GUIDE USA. 8 th Edition USA

RIDGE-JOIST CONNECTION 12/12 maximum slope

Use the Design Properties (100% Load Duration) Table from Page 3 for questions 1-7

SECTION: 15 ZONING RULE LOT AREA 6134 S.F S.F. BUILDING AREA (FOOTPRINT) LOT COVERAGE 20.2% 24.86' FRONT YARD SIDE YARD 8.

installation Guide What you don t Safety I-Joist Storage and Handling United states Installation Instructions for Residential Floor Systems

Main Floor Revisions: 38' 0" Rm1 H3 50' 0" Bk1 B1 Rm2 B5 (26)-2 H2 B2 H3 (3)-3 B3 (11)-4 Bk1 B1 (5)-5 Rm4 Bk1 Rm3 Bk1 24' 0" 6' 0" 20' 0" START FRAMIN

ROOF SYSTEM DESIGN GUIDE

TRUS JOIST TJI. Featuring Silent Floor Joists for Residential Applications. Uniform and Predictable. Lightweight for Fast Installation

TRUS JOIST TJI. Featuring Silent Floor Joists for Residential Applications. Uniform and Predictable. Lightweight for Fast Installation

T-BRACE / I-BRACE DETAIL WITH 2X BRACE ONLY

Beam & Header Technical Guide. LP SolidStart LVL. 2900F b -2.0E. U.S. Technical Guide U.S. TECHNICAL GUIDE

Residential I-Joist & LVL INSTALLATION GUIDE

TJI 110, TJI 210, TJI 230,

APA Performance Rated Rim Boards

EWP Product Guide. For Use With Products Manufactured by. TJI 110, 210, 230, 360, & 560 Joists.

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

3.1 General Provisions

For Use With Products Manufactured by

TJI 110, TJI 210, TJI 230, TJI 360, TJI 560 AND TJI 560D JOISTS

Fastener Schedule. a, b, c. FASTENER Roof 3-8d (2 1 / ) / ) 3-10d. 3-10d ( ) 3-16d box nails. (3 1 2 toe nails on one side

Wood I-Joists by Curtis Eck, P.E.

For Use With Products Manufactured by

FASTENERS BUILDING DEPARTMENT

Load Tables, Technical Data and Installation Instructions

LSSH179 THF17925 THO17118

Site Installation Guide

THE ENGINEERED WOOD ASSOCIATION

CONNECTOR SELECTION GUIDE

EWP Product Guide. For Use With Products Manufactured by. Corona Westampton Largo Montgomery Humble Thornhill, Ontario THFI2514

LP SolidStart LSL. LP SolidStart LSL Prescriptive Roof Framing Technical Guide 2500F b-1.75e, 2360F b -1.55E and 1730F b -1.

APPLICATION FOR A BUILDING PERMIT

Sections & Details VOCABULARY

ESR-1254 * DELETED BY CITY OF LOS ANGELES. Reissued April 1, 2006 This report is subject to re-examination in one year.

Best Barns USA. Assembly Book. 12'x 16' the Millcreek. Revised September 19, 2017

FMJ AJS 24 & BCI 60s Joist for Fire Protection of Floors Installation Guide

Best Barns USA Assembly Book

Materials. Description Quantity/Size Material Foundation Drainage material. 1.4 cu. yd. Compactible gravel

2x6. 2x8. 2x10. Size. 2-2x10 8'-5" w/ 2 NJ 7'-3" w/ 2 NJ

Best Barns USA Assembly Book

Lateral Support. Decks over 24 above grade require lateral support* *Exceptions to be discussed later

EWP Product Guide. For Use With Products Manufactured by. BCI I-Joists. Canadian Specifiers Guide. USPconnectors.com LIMIT STATES DESIGN SKH2520R-2

ESR-2403 Reissued October 1, 2009 This report is subject to re-examination in one year.

Backer Block (both sides) of web with single RFPI Joist. (12) - 10d. Backer Block. each side. 2 min. 2 min.

Prevention and Repair of Floor System Squeaks

HOW TO BUILD A 12X8 SHED

With Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e H O W B U I L D S H E D.

Best Barns USA Assembly Book

Best Barns USA Assembly Book

Exterior Wall Fastener Schedule

Best Barns USA Assembly Book

Best Barns USA Assembly Book

BUILDING THE BASIC SHED. Step A: Build the Foundation & Floor Frame

EWP Product Guide. For Use With Products Manufactured by THF23140 LSSH179 SKH1720L

A. Rough carpentry includes but is not limited to the following:

With Illustrations, Blueprints & Step By Step Details Brought To You By ShedPlansz.Com Click Here To Get More Shed Plans

SECTION ROUGH CARPENTRY 1.1 DESCRIPTION OF WORK:

Best Barns USA. Regency Deluxe. 8' x 12' Assembly Book. revised February 15, 2017

Best Barns USA Assembly Book

EWP Product Guide. For Use With Products Manufactured by. Canadian Specifiers Guide. USPconnectors.com LIMIT STATES DESIGN SKH2520R-2 LSSH35 THFI2514

Best Barns USA Assembly Book

Chapter 33: Lofts (Or Second Floors)

Chapter 23. Garage Construction

VERSA-LAM. An Introduction to VERSA-LAM Products

ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013.

SDWH TIMBER-HEX Screw

Best Barns USA Assembly Book

Best Barns USA Assembly Book

With Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e Download 12,000 More Shed Plans

8 x 10 Timber-frame Garden Shed

Best Barns USA Assembly Book

Best Barns USA. the Brookhaven 10' x 16' Assembly Book. revised March 23, 2016

Shapes Siding. Perfection Shingles. Chalk Line

Best Barns USA Assembly Book Revised October 24, 2017

Best Barns USA Assembly Book

Description. Lesson Outcomes. Assumptions. Build a Floor. Carpenter

MAT105: Floor Framing

Best Barns USA Assembly Book

Assembly Book. the Fairview. Building Size 12'x12' Revised July 25, 2012

Best Barns USA Assembly Book

Best Barns USA Assembly Book

SECTION ROUGH CARPENTRY

Call (770) STEP 6: Caulk bolt hole within the bracket for protection from the elements.

Best Barns USA Assembly Book

Installation Instructions for Standard Lap and Self-Aligning Lap Siding

Best Barns USA Assembly Book

LVL8 H1.2 GENERAL FRAMING. Eco Friendly Revolutionary H1.2 Treatment Azotek by Zelam

Best Barns USA Assembly Book

EWP Product Guide. For Use With Products Manufactured by.

Best Barns USA Assembly Book

SAMPLE INSTRUCTIONS. Best Barns USA Assembly Book. the Belmont with pocket doors. Building Size 12'x16' or 12'x20' Revised January 10, 2012

Transcription:

Reorder TJI 110 TJI 210 TJI 230 TJI 360 TJI 560 Joists May September 2013 2011 Reorder TJ-9001 TJ-9001 INSTALLATION GUIDE FOR FLOOR AND ROOF FRAMING ARNING: DO NOT walk on joists until braced. INJURY MAY RESULT. ARNING: DO NOT stack building materials on unsheathed joists. Stack only over beams or walls. IMPORTANT: PLEASE READ CAREFULLY! ARNING: DO NOT walk on joists that are lying flat. ARNING: JOISTS ARE UNSTABLE UNTIL BRACED LATERALLY Bracing Includes: Blocking, Hangers, Rim Board, Sheathing, Rim Joist, Strut Lines Lack of proper bracing during construction can result in serious accidents. Observe the following guidelines: 1. Properly install all blocking, hangers, rim boards, and rim joists at TJI joist end supports. 2. Establish a permanent deck (), fastened to the first 4 feet of joists at the end of the bay or braced end wall. 3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area and to each joist. 4. Sheathing must be completely attached to each TJI joist before additional loads can be placed on the system. 5. Ends of cantilevers require safety bracing on both the top and bottom flanges. 6. The flanges must remain straight within 1 2" from true alignment. La Sécurité Avant Tout AVERTISSEMENT Lire Attentivement Les solives non contreventées latéralement sont instables. Voir le guide d installation avant la pose des solives TJI. Ne pas circuler sur les solives TJI avant qu elles ne soient adéquatement contreventées. Risque de blessure. Ne pas empilées des matériaux sur des solives avant d avoir installé les sous-plancher. Les entreposer temporairement au-dessus des poutres et murs. La Seguridad Ante Todo ADVERTENCIA Por Favor Lea Cuidadosamente Las viguetas son inestables hasta que sean reforzadas lateralmente. Vea la guía de instalaciones antes de instalar las viguetas TJI. No camine sobre las viguetas hasta que sean apuntaladas. No ponga materiales de construcción sobre las viguetas TJI antes de instalar el triplay. Ponga materials únicamente sobre vigas o muros. This guide is intended for the products shown in dry-use conditions. woodbywy.com 1.888.453.8358

CONTENTS Floor Allowable Holes: Trus Joist TJI Joists.... 1 TJI Joist Nailing Requirements at Bearing.... 2 Installation Recommendations.... 2 TJI Joist Floor Framing.... 3 Fastening of Floor Panels.... 3 Rim Board Details and Installation.... 4 Floor Details.... 4 5 Cantilever Details... 5 Filler and Backer Blocks.... 5 eb Stiffeners.... 6 Framing Connectors.... 8 Roof and all Allowable Holes: Trus Joist TimberStrand LSL all Studs...................... 2 eb Stiffeners.... 6 Typical Roof and all Framing.... 6 Ceiling Joists.... 6 Roof Details.... 7 Framing Connectors.... 8 Shear Blocking and Ventilation Holes.. 8 TJI Joist Nailing Requirements at Bearing.... 8 1 Beam and Column Allowable Holes: Trus Joist TimberStrand LSL, Parallam PSL, Microllam LVL Headers and Beams.... 2 Beam and Column Details... 9 Beam and Header Bearings... 9 BUILD SAFELY e at eyerhaeuser are committed to working safely and want to remind you to do the same. e encourage you to follow the recommendations of OSHA (www.osha.gov) in the U.S. or provincial regulations (www.canoshweb.org/en/) in Canada regarding: Personal protective equipment (PPE) for hands, feet, head, and eyes Fall protection Use of pneumatic nailers and other hand tools Forklift safety Please adhere to the eyerhaeuser product installation details, including the installation of safety bracing on unsheathed floors and roofs. PRODUCT IDENTIFICATION 1 3 4" 2 1 16" 2 5 16" 2 5 16" 3 1 2" 1 1 4" 1 3 8" 1 1 4" 1 3 8" 1 1 4" 1 3 8" 1 3 8" 1 3 8" 9½" 9½" 9½" 9½" 11 3 8" 11 7 8" 3 8" 7 8" 3 11 8" 7 8" 11 3 8" 7 8" 7 14" 16" 14" 14" 14" 16" 16" 16" 9½" 11 7 8" 14" 16" TJI 110 joists TJI 210 joists TJI 230 joists TJI 360 joists TJI 560 joists ALLOABLE HOLES TJI JOISTS DO NOT cut holes in cantilever reinforcement. Min. distance from Table A 6" OR Min. distance from Table B 6" 1½" hole may be cut anywhere in web outside of hatched zone DO NOT cut or notch flange. 6" No field cut holes in hatched zone L 1 2 x D 1 D 1 minimum (applies to all holes except knockouts) Closely grouped round holes are permitted if the group perimeter meets requirements for round or square holes L 2 2 x L 2 minimum D 2 6" No field cut holes in hatched zone 6" Do not cut holes larger than 1 1 /2" in cantilever

Table A End Support Minimum distance from edge of hole to inside face of nearest end support Joist Depth 9 1 2" 11 7 8" 14" 16" Round Hole Size Square or Rectangular Hole Size TJI 2" 3" 4" 6 1 2" 8 7 8" 11" 13" 2" 3" 4" 6 1 2" 8 7 8" 11" 13" 110 1'-0" 1'-6" 2'-0" 5'-0" 1'-0" 1'-6" 2'-6" 4'-6" 210 1'-0" 1'-6" 2'-6" 5'-6" 1'-0" 2'-0" 2'-6" 5'-0" 230 1'-6" 2'-0" 2'-6" 5'-6" 1'-0" 2'-0" 3'-0" 5'-0" 360 1'-6" 2'-0" 3'-0" 6'-0" 1'-6" 2'-6" 3'-6" 5'-6" 560 1'-6" 2'-6" 3'-6" 7'-0" 2'-0" 3'-0" 4'-0" 6'-0" 110 1'-0" 1'-0" 1'-6" 2'-6" 5'-6" 1'-0" 1'-6" 2'-0" 4'-6" 6'-0" 210 1'-0" 1'-6" 2'-0" 3'-0" 6'-0" 1'-0" 1'-6" 2'-6" 5'-0" 6'-6" 230 1'-0" 1'-6" 2'-0" 3'-0" 6'-6" 1'-0" 2'-0" 2'-6" 5'-6" 7'-0" 360 1'-6" 2'-0" 3'-0" 4'-6" 7'-0" 1'-6" 2'-6" 3'-6" 6'-6" 7'-6" 560 1'-6" 2'-6" 3'-0" 5'-6" 8'-0" 2'-6" 3'-6" 4'-6" 7'-0" 8'-0" 110 1'-0" 1'-0" 1'-0" 1'-6" 3'-0" 5'-6" 1'-0" 1'-0" 1'-6" 3'-6" 6'-0" 8'-0" 210 1'-0" 1'-0" 1'-0" 2'-0" 3'-6" 6'-0" 1'-0" 1'-0" 2'-0" 4'-0" 6'-6" 8'-6" 230 1'-0" 1'-0" 1'-0" 2'-6" 4'-0" 7'-0" 1'-0" 1'-0" 2'-0" 4'-0" 7'-0" 9'-0" 360 1'-0" 1'-0" 1'-6" 3'-6" 5'-6" 8'-0" 1'-0" 1'-6" 2'-6" 6'-0" 8'-0" 9'-6" 560 1'-0" 1'-0" 2'-0" 4'-6" 6'-6" 9'-0" 1'-6" 3'-0" 4'-0" 7'-0" 9'-0" 10'-0" 210 1'-0" 1'-0" 1'-0" 1'-0" 2'-6" 3'-6" 6'-0" 1'-0" 1'-0" 1'-0" 3'-0" 6'-6" 8'-0" 11'-0" 230 1'-0" 1'-0" 1'-0" 1'-6" 3'-0" 4'-0" 7'-0" 1'-0" 1'-0" 1'-0" 3'-6" 7'-0" 9'-0" 11'-0" 360 1'-0" 1'-0" 1'-0" 2'-6" 4'-6" 6'-6" 9'-0" 1'-0" 1'-0" 1'-6" 5'-0" 9'-0" 10'-0" 11'-6" 560 1'-0" 1'-0" 1'-0" 2'-6" 5'-0" 7'-6" 10'-0" 1'-0" 2'-0" 3'-0" 6'-6" 10'-0" 11'-0" 12'-0" Table B Intermediate or Cantilever Support Minimum distance from edge of hole to inside face of nearest intermediate or cantilever support Joist Depth 9 1 2" 11 7 8" 14" 16" Round Hole Size Square or Rectangular Hole Size TJI 2" 3" 4" 6 1 2" 8 7 8" 11" 13" 2" 3" 4" 6 1 2" 8 7 8" 11" 13" 110 2'-0" 2'-6" 3'-6" 7'-6" 1'-6" 2'-6" 3'-6" 6'-6" 210 2'-0" 2'-6" 3'-6" 8'-0" 2'-0" 3'-0" 4'-0" 7'-6" 230 2'-6" 3'-0" 4'-0" 8'-6" 2'-0" 3'-6" 4'-6" 7'-6" 360 3'-0" 4'-0" 5'-6" 9'-0" 3'-0" 4'-6" 5'-6" 8'-0" 560 3'-6" 5'-0" 6'-0" 10'-0" 4'-0" 5'-6" 6'-6" 9'-0" 110 1'-0" 1'-0" 1'-6" 4'-0" 8'-6" 1'-0" 1'-6" 2'-6" 7'-0" 9'-6" 210 1'-0" 1'-0" 2'-0" 4'-6" 9'-0" 1'-0" 2'-0" 3'-0" 8'-0" 10'-0" 230 1'-0" 2'-0" 2'-6" 5'-0" 10'-0" 1'-0" 2'-6" 3'-6" 8'-6" 10'-6" 360 2'-0" 3'-0" 4'-0" 7'-0" 11'-0" 2'-0" 3'-6" 5'-0" 9'-6" 11'-0" 560 1'-6" 3'-0" 4'-6" 8'-0" 12'-0" 3'-0" 4'-6" 6'-0" 10'-6" 12'-0" 110 1'-0" 1'-0" 1'-0" 2'-0" 4'-6" 8'-6" 1'-0" 1'-0" 1'-0" 5'-0" 9'-0" 12'-0" 210 1'-0" 1'-0" 1'-0" 2'-6" 5'-6" 9'-6" 1'-0" 1'-0" 2'-0" 6'-0" 10'-0" 13'-0" 230 1'-0" 1'-0" 1'-0" 3'-6" 6'-0" 10'-6" 1'-0" 1'-0" 2'-6" 6'-6" 11'-0" 13'-6" 360 1'-0" 1'-0" 2'-0" 5'-6" 8'-6" 12'-6" 1'-0" 2'-0" 4'-0" 9'-0" 12'-0" 14'-0" 560 1'-0" 1'-0" 1'-6" 5'-6" 9'-6" 13'-6" 1'-0" 3'-0" 5'-0" 10'-0" 13'-6" 15'-0" 210 1'-0" 1'-0" 1'-0" 1'-0" 3'-6" 6'-0" 10'-0" 1'-0" 1'-0" 1'-0" 4'-6" 10'-0" 12'-6" 16'-0" 230 1'-0" 1'-0" 1'-0" 1'-6" 4'-0" 6'-6" 11'-0" 1'-0" 1'-0" 1'-0" 5'-0" 10'-6" 13'-6" 16'-6" 360 1'-0" 1'-0" 1'-0" 3'-0" 6'-6" 10'-0" 13'-6" 1'-0" 1'-0" 2'-0" 7'-6" 13'-0" 14'-6" 17'-0" 560 1'-0" 1'-0" 1'-0" 2'-6" 7'-0" 11'-0" 15'-0" 1'-0" 1'-0" 3'-6" 9'-0" 14'-6" 16'-0" 18'-0" Leave 1 8" of web (minimum) at top and bottom of hole. DO NOT cut joist flanges. Tables are based on uniform load tables in current design literature. For simple span (5' minimum), uniformly loaded joists used in residential applications, one maximum size round hole may be located at the center of the joist span provided that no other holes occur in the joist.

ALLOABLE HOLES BEAMS and STUDS 1.55E TimberStrand LSL Headers and Beams 1 3 depth 2 x diameter of the largest hole (minimum) Allowed hole zone 1.55E TimberStrand LSL 2 GENERAL NOTES Other Trus Joist Headers and Beams 1.3E TimberStrand LSL hole zone d GENERAL NOTES 8" 8" Allowed hole zone suitable for headers and beams with uniform and/or concentrated loads anywhere along the member. d Microllam LVL and Parallam PSL hole zone Allowed hole zone suitable for headers and beams with uniform loads only. No holes in cantilevers. Microllam LVL and Parallam PSL allowed hole zone middle 1 3 span TimberStrand LSL all Studs 2 x diameter of the largest hole (minimum) 1.3E TimberStrand LSL allowed hole zone Round holes only. No holes in headers or beams in plank orientation. Round holes only. d 1 3 depth No holes in headers or beams in plank orientation. Header or Beam Depth 91 4" 91 2" 3" 111 4" 11 7 8" 3 5 8" 14" 16" 4 5 8" See illustration for allowed hole zone. Header or Beam Depth Maximum Round Hole Size DO NOT cut, notch, or drill holes in headers or beams except as indicated in the illustrations and tables. Other Trus Joist Beams Maximum Round Hole Size 4 3 8" 1" 51 2" 1 3 4" 71 4" 20" 2" See illustration for allowed hole zone. One notch may be cut anywhere except the middle 1 3 of the length of the stud or column. Holes may be drilled anywhere along the length of the stud or column but must be at least 5 8" from the edge. 5 8" minimum edge distance Maximum diameter: 1 3 8" for 3 1 2" thick walls (1 1 8" in Canada); 2 3 16" for 5 1 2" 11 7 8" thick walls (1 13 16" in Canada) Maximum notch: 7 8" for 3 1 2" thick walls 1 3 8" for 5 1 2" 11 7 8" thick walls DO NOT cut a notch and a hole in the same cross section.

TJI JOIST NAILING REQUIREMENTS AT BEARING TJI Joist to Bearing Plate 1 1 8" TJ Rim Board or 1 1 4" TimberStrand LSL Squash Blocks to TJI Joist (Load bearing wall above) One 8d (0.113" x 2 1 2") nail each side. Drive nails at an angle at least 1 1 2" from end. One 10d (0.128" x 3") nail into each flange 1 3 4" minimum end bearing for single-family applications Increased bearing capacities may be achieved with increased bearing lengths. See plans for required bearing lengths. Shear transfer nailing: Use connections equivalent to floor panel nailing schedule. See page 4. 1 3 4" minimum bearing 3 1 2" minimum intermediate bearing; 5 1 4" may be required for maximum capacity Rim to TJI Joist 1 1 8" TJ Rim Board, 1 1 4" TimberStrand LSL, or TJI 110 rim joist: One 10d (0.131" x 3") nail into each flange TJI 210, 230, and 360 rim joist: One 16d (0.135" x 3 1 2") nail into each flange Locate rim board joint between joists TJI 560 rim joist: Toenail with 10d (0.128" x 3") nails, one each side of TJI joist flange Also see detail B2, page 5 Top View TJI 560 floor joist TJI 560 rim joist INSTALLATION RECOMMENDATIONS RECOMMENDED COMPONENTS eyerhaeuser Edge Gold floor panels TJI joists 1 1 8" TJ Rim Board or 1 1 4" TimberStrand LSL RECOMMENDED ADHESIVES eyerhaeuser recommends using solvent-based subfloor adhesives that meet ASTM D3498 (AFG-01) performance standards. hen latex subfloor adhesive is required, careful selection is necessary due to a wide range of performance between brands. Apply a 1 4" or larger bead of adhesive DON PORE DRAINAGE THIS END At abutting panel edges, apply two 1 4" beads of adhesive DON PORE DRAINAGE THIS END DON PORE DRAINAGE THIS END DON PORE DRAINAGE THIS END DON DRAINA Nail panel to joist at 12" on-center in field and 6" on-center along panel edges. Apply fasteners 3 8" from panel edges. For 3 4" panels, use 8d (0.131" x 2 1 2") or 6d (0.120" x 2") deformed-shank nails or other code-approved fasteners. For 7 8" panels, use 8d (0.131" x 2 1 2") or 8d (0.120" x 2 1 2") deformed-shank nails or other code-approved fasteners. Fully nail floor panel within 10 minutes of applying adhesive (or sooner if required by adhesive manufacturer). Screws may be substituted for the nails noted above if the screws have equivalent lateral load capacity.

TJI JOIST FLOOR FRAMING 3 TJI joist floor framing does not require bridging or mid-span blocking TJI rim joist P A2 L5 DO NOT use sawn lumber for rim board or blocking as it may shrink after installation. Use only engineered lumber. E2 B4 A1 B3 B2 B1 H2 See Filler and Backer Blocks on page 5 CS Use B1 or B2 at intermediate bearings with load bearing or shear wall from above ARNING Joists are unstable until laterally braced. See arning on cover. E1 L3 Joists must be laterally supported at cantilever and end bearings by blocking panels, hangers, or direct attachment to a rim board or rim joist. A3_ H1 Rim board joint between joists 1 1 8" TJ Rim Board or 1 1 4" TimberStrand LSL L1 End of joists at centerline of support L4 H1 L2 LA Safety bracing (1x4 minimum) at 8' on-center (6' on-center for TJI 110 joists) and extended to a braced end wall. Fasten at each joist with two 8d (0.113" x 2 1 2") nails minimum (see arning on cover). Protect untreated wood from direct contact with concrete INSTALLATION TIPS 1 1 2" knockouts at approximately 12" on-center Bearing plate to be flush with inside face of wall or beam H3 See Allowable Holes on page 1 Subfloor adhesive will improve floor performance, but may not be required. Squash blocks and blocking panels carry stacked vertical loads (details B1 and B2). Packing out the web of a TJI joist (with web stiffeners) is not a substitute for squash blocks or blocking panels. Structural See Exterior Deck Attachment on page 4 Shifted joist Plumbing drop Additional joist hen joists are doubled at non-load bearing parallel partitions, space joists apart the width of the wall for plumbing or HVAC. Additional joist at plumbing drop (see detail above).

End bearings (see page 4) A1 A2 A3_ with blocking panels with TJI rim joist with rim board Intermediate bearings* (see page 5) B1 with blocking panels to support load bearing wall above B2 with squash blocks to support load bearing wall above B3 without blocking panels or squash blocks (no wall above) Cantilever details (see page 5) E1 no reinforcement E2 3 4" reinforcement on one side DETAIL SCHEDULE E3 3 4" reinforcement both sides E4 joist reinforcement F1 deck cantilever PB1 permanent bracing Cantilevers less than 5" (see page 5) E5 3 4" reinforcement on one side, with vertical blocking E6 3 4" reinforcement both sides, with vertical blocking E7 3 4" reinforcement on one side, with horizontal blocking E8 3 4" reinforcement on both sides, with horizontal blocking Hanger Details (more connector information on page 8) H1 TJI joist to beam (see page 8) H2 TJI joist to joist (see page 5) H3 TJI joist on masonry wall or steel beam (see page 8) Other details B4 butting joists with blocking panels (see above) CS column support (see page 4) LA exterior deck attachment (see page 4) web stiffeners (see page 6) L beam details (see page 9) P column details (see page 9) *Load bearing wall must stack over wall below. Blocking panels may be required at shear walls above or below. JAVELIN SOFTARE FRAMING PLANS A_ B_ E_ eb stiffeners required on each side of joist at bearing. Refer to your Javelin framing plan. Bearing requirements as shown on the Javelin framing plan are job-specific and supersede minimum bearing requirements listed. FASTENING OF FLOOR PANELS Guidelines for Closest On-Center Spacing per Row Nail Size 110, 210, and 230 TJI (1)(2) Rim board 1 1 2" 360 and 1 560 1 8" TJ 1 1 4" TimberStrand LSL 8d (0.113" x 2 1 2"), 8d (0.131" x 2 1 2") 4" 3" 6" 4" 3" 3" 3" 10d (0.148" x 3"), 12d (0.148" x 3 1 4") 4" (3) 4" (3) 6" 4" 4" 4" 4" 16d (0.162" x 3 1 2") 6" 6" 16" 6" (4) 6" (4) 8" 6" (1) Stagger nails when using 4" on center spacing and maintain 3 8" joist and panel edge distance. One row of fasteners is permitted (two at abutting panel edges) for diaphragms. Fastener spacing for TJI joists in diaphragm applications cannot be less than shown in table. hen fastener spacing for blocking is less than spacing shown above, rectangular blocking must be used in lieu of TJI joists. (2) For non-diaphragm applications, multiple rows of fasteners are permitted if the rows are offset at least ½" and staggered. (3) Can be reduced to 3" on-center for light gauge steel straps with 10d (0.148" x 1½") nails. (4) Can be reduced to 4" on-center if nail penetration into the narrow edge is no more than 1 3 8" (to avoid splitting). Recommended nailing is 12" on-center in field and 6" on-center along panel edge. Fastening requirements on engineered drawings supersede recommendations listed above. eyerhaeuser recommends using a solvent-based subfloor adhesive on all contact points between panels and floor framing. See RECOMMENDED ADHESIVES on page 2. TimberStrand LSL or wider Microllam LVL Parallam PSL Nailing rows must be offset at least 1 2" and staggered. 14 ga. staples may be substituted for 8d (0.113" x 2 1 2") nails if minimum penetration of 1" into the TJI joist or rim board is achieved. Maximum spacing of nails is 18" on-center for TJI joists.

RIM BOARD DETAILS AND INSTALLATION Plate nail Floor panel nail Rim board to TJI joist 1 1 8" TJ Rim Board or 1 1 4" TimberStrand LSL (see nailing schedule below) Toe nail Rim board to TJI joist Sheathing may be attached as shown in A3.4 2x4 or 2x6 stud wall at 16" on-center hen panel thickness exceeds 7 8", trim tongue at rim board TJI joist spanning in either direction TJI joist to plate eb stiffener required on both sides at A3._ ONLY Plate nail Floor panel nail Rim board to TJI joist 1 1 4" TimberStrand LSL rim board Attach per nailing schedule (below) Toe nail Rim board to TJI joist 12" minimum Install proper blocking to support all panel edges A3.1 A3.2 A3.3 A3.1 A3.2 A3.3 A3.4 A3.4 2x4 or 2x6 stud wall at 16" on-center eb stiffener required on both sides at A3.4 ONLY 4 hen panel thickness exceeds 7 8", trim tongue at rim board TJI joist spanning in either direction TJI joist to plate all Framing Specifications Rim Board Installation Detail A3.1 (1)(2) A3.2 (1)(2) A3.3 (1) A3.4 (1) Rim Board Thickness 1 1 8" 11 4" 11 4" 11 4" Plate Nail 16d (0.135" x 3 1 2") 16" o.c. 12" o.c. 8" o.c. 12" o.c. Floor Panel Nail 8d (0.131" x 2 1 2") 6" o.c. Rim Board to TJI Joist 10d (0.131" x 3") One into each flange Toe Nail 10d (0.131" x 3") 6" o.c. 6" o.c. 4" o.c. 6" o.c. TJI Joist to Plate 8d (0.113" x 2 1 2") Two nails driven at an angle into bottom flange, one each side of web at least 1½" from end Sheathing 7 16" structural 1 3 8" structural 1 (3) in all areas (4) Boundary Nailing 8d (0.131" x 2½") at 6" o.c. 8d (0.131" x 2½") at 4" o.c. Per Code Per Code Intermediate Nailing 8d (0.131" x 2½") at 12" o.c. Max. indow Opening Height 5'-4" (5) % of all with Full Height Sheathing 70% Exterior Face Interior Face Holdowns Sheathing ½" gypsum Boundary Nailing Per Code Per Code 5d (0.086" x 1 5 8") at 7" o.c. Intermediate Nailing 5d (0.086" x 1 5 8") at 10" o.c. 90 mph ind Zone None 120 mph ind Zone 16" o.c. within 10' 16" o.c. within 6' 16" o.c. within 4' of corners (6) of corners (6) of corners (6) none (1) All shall be properly blocked and nailed. (2) Verify the lateral capacity of the wall. Not all types of code-allowed wall construction provide the same lateral resistance. Check with your local building official or design professional of record. (3) Detail A3.3 shall be a segmented wall, location of full-height structural per code. (4) Sheathing shall be continuous over all plate-to-plate and plate-to-rim-board interfaces and may butt together at mid-depth of rim board as shown in A3.4. At foundation, fasten the bottom edge of the to the sill plate. (5) In addition, one 6'-8" standard door opening is allowed. (6) If required, holdowns shall be Simpson Strong-Tie CS20 (or equivalent) straps attached with four 8d (0.131" x 2 1 2") nails at each end. As an alternative to holdown straps, wall may be attached as shown in A3.4. See footnote 4.

FLOOR DETAILS Plate nail Blocking panel: 1 1 8" TJ Rim Board, 1 1 4" TimberStrand LSL, or TJI joist Plate nail eb stiffener required on both sides at A2 ONLY Rim-tojoist nail Toe nail Toe nail eb stiffener required on both sides at A1 ONLY TJI rim joist A1 A1 Attach blocking per A3.1 in rim board installation table above A2 A2 Must have 1¾" minimum joist bearing at ends. Attach rim joist per A3.1 in rim board installation table above. Exterior Deck Attachment Load from above Structural exterior Flashing 1 1 8" TJ Rim Board or 1 1 4" TimberStrand LSL Treated 2x_ ledger 2x4 minimum squash blocks 1 16" Maintain 2" distance (minimum) from edge of ledger to fastener CS Use 2x4 minimum squash blocks to transfer load around TJI joist LA Corrosion-resistant fasteners required for wet-service applications

FLOOR DETAILS 5 Load bearing or braced/shear wall above (must stack over wall below) Blocking panel: 1 1 8" TJ Rim Board, 1 1 4" TimberStrand LSL, or TJI joist No load bearing wall above 2x4 minimum squash blocks B1 B1 1 16" eb stiffener required on both sides at B1 or B2 ONLY. eb stiffener required on both sides at B3 ONLY. B2 B2 Blocking panels may be required with braced/ shear walls above or below see detail B1 B3 B3 Blocking panels may be required with braced/ shear walls above or below see detail B1 CANTILEVER DETAILS At PB1, cantilever back span must be permanently braced with either direct-applied ceiling along entire length or permanent bracing at 1 3 points. See detail below for connections. 1 8" TJ Rim Board or 1 1 4" TimberStrand LSL, typical. Nail with 10d (0.131" x 3") nails, one each at top and bottom flange. 1 3 8' max., typical 1 3 8" diameter maximum hole for 11 7 8" 16" deep blocking panels; 6" diameter maximum for blocking panels 9 1 2" deep or shorter than 12" long. Do not cut flanges. eb stiffener required on both sides at E1 ONLY E1 E1 E3 E2 1 1 8" TJ Rim Board or 1 1 4" TimberStrand LSL closure, typical 4'-0" length of 3 4" reinforcement (2'-0" maximum cantilever) on one side at E2, both sides at E3. Attach to joist flange with 8d (0.131" x 2 1 2") nails at 6" on-center. hen reinforcing both sides, stagger nails. E4 1 3 E5 12" length of 3 4" reinforcement on one side at E5/E7, both sides at E6/E8. Attach to joist flanges with one 8d (0.131" x 2 1 2") nail at each corner. E6 Blocking panel between each joist. Full depth vertical blocking at E5 and E6, horizontal blocking at E7 and E8. PB1 E8 E7 ood backer Less than 5" Nail rim to blocking panel and blocking panel to plate with connections equivalent to floor panel schedule (E7 and E8) F1 4'-0" maximum (uniform loads only) Nail through 2x_ cantilever, wood backer, and TJI joist web with 2 rows 10d (0.148" x 3") nails at 6" on-center, clinched. Use 16d (0.135" x 3 1 2") nails with TJI 560 joists. F1 applies to uniformly loaded joists only. 1 1 2 times cantilever length Cantilever length 6'-0" length of TJI joist reinforcement (2'-0" maximum cantilever) and filler block at E4. Attach to joist web with 3 rows 10d (0.148" x 3") nails at 6" on-center, clinched. Use 4'-0" length with 9 1 2" and 11 7 8" TJI joists, and attach to joist web with 2 rows 10d (0.148" x 3") nails at 6" on-center, clinched. Not for use with TJI 560 joists. Two 2 1 2" screws for 2x_ strapping connections hen specified on the layout, one of the bracing options shown at right is required PB1 Apply subfloor adhesive to all contact surfaces Two 8d (0.113" x 2 1 2") nails or 2 1 2" screws, typical Directly applied ceiling FILLER AND BACKER BLOCKS HANGER BACKER BLOCK Install tight to top flange (tight to bottom flange with face mount hangers). Single-Family Applications: Attach with ten 10d (0.128" x 3") nails, clinched when possible. Multi-Family Applications: Attach with fifteen 10d (0.128" x 3") nails, clinched when possible. H2 Backer block both sides of web with single TJI joist DOUBLE TJI JOIST FILLER BLOCK Single-Family Applications: Attach with ten 10d (0.128" x 3") nails, clinched. Use ten 16d (0.135" x 3 1 2") nails from each side with TJI 560 joists. Multi-Family Applications: Attach with fifteen 10d (0.128" x 3") nails, clinched. Use fifteen 16d (0.135" x 3 1 2") nails from each side with TJI 560 joists. Filler and Backer Block Sizes TJI 110 210 230 or 360 560 Depth 9½" or 11 7 8" 14" 9½" or 11 7 8" 14" or 16" 9½" or 11 7 8" 14" or 16" 9½" or 14" or 11 7 8" 16" Filler Block (1) (Detail H2) Cantilever Filler (Detail E4) Backer Block (1) (Detail F1 or H2) 2x6 2x6 4'-0" long 2x8 2x10 6'-0" long 2x6 + 3 8" 2x6 + 3 8" 4'-0" long 2x8 + 3 8" 2x10 + 3 8" 6'-0" long 2x6 + ½" 2x6 + ½" 4'-0" long 2x8 + ½" 2x10 + ½" 6'-0" long Two 2x6 Two 2x8 Not applicable 5 8" or ¾" ¾" or 7 8" 7 8" or 1" net 2x6 2x8 (1) If necessary, increase filler and backer block height for face mount hangers and maintain 1 8" gap at top of joist. See detail. Filler and backer block dimensions should accommodate required nailing without splitting. The suggested minimum length is 24" for filler and 12" for backer blocks.

EB STIFFENERS FLOOR AND ROOF APPLICATIONS 6 1" (1 1 2" for TJI 560 joists) EB STIFFENER SIZES Gap: 1 8" minimum 2 3 4" maximum Three 8d (0.113" x 2 1 2") nails, clinched. Use three 16d (0.135" x 3 1 2") nails for TJI 560 joists. eb stiffener both sides. See sizes below. Tight fit TJI 110 joists: 5 8" x 2 5 16" minimum (1) TJI 210 joists: 3 4" x 2 5 16" minimum (1) TJI 230 and 360 joists: 7 8" x 2 5 16" minimum (1) TJI 560 joists: 2x4, construction grade or better (1) PS1 or PS2, face grain vertical EB STIFFENER REQUIREMENTS Required at all birdsmouth cuts. Required at all sloped hangers. Required if the sides of the hanger do not extend to l aterally support at least 3 8" of the TJI joist top flange. Only required at intermediate bearing locations when noted on framing plan. TYPICAL ROOF AND ALL FRAMING DETAIL SCHEDULE Roof details (see page 7) R1 on bevel plate R1 on bevel plate with web stiffeners R3 with variable slope seat connector R3 with seat connector and web stiffeners R5 with birdsmouth cut R7 intermediate bearing intermediate bearing with web stiffeners R7 R8 2x4 outrigger and filler with birdsmouth cut R9 2x4 outrigger without filler R10 2x4 outrigger with filler R10 R14 R14 2x4 outrigger with filler and web stiffeners ridge detail ridge detail, with web stiffeners Other details O 2x_ overhang at end wall SB shear blocking (see page 8) web stiffeners Hanger details (see page 8) H5 slope adjusted hanger H6 header on slope Joists must be laterally supported at cantilever and end bearings by blocking panels, hangers, or direct attachment to a rim board or rim joist.

See Filler and Backer Blocks, page 5 R14 H5 Safety bracing (1x4 minimum) at 8' on-center (6' on-center for TJI 110 joists) and extended to a braced end wall. Fasten at each joist with two 8d (0.113" x 2 1 2") nails minimum. (See arning on cover). R10 H6 R7 Blocking panels or shear blocking optional for joist stability at intermediate supports 2x4 block for soffit support O R9 Install cripples tight to king stud at each end of header R10 R1 R1 R3 24" max. R5 ARNING Joists are unstable until laterally braced. See arning on cover. Double joist may be required R8 Joists must be laterally supported at cantilever and end bearings by shear blocking, hangers, or direct attachment to a rim board or rim joist Notch around TJI joist top flange Let-in bracing Studs must be doubled when notched in middle third of length. Refer to hole charts for allowable holes and notches. Safety bracing. Lack of proper bracing can result in serious accidents. See Allowable Holes, page 1 Lateral bracing required at end bearings Ceiling Joists Ceiling joist must be braced at 18" on-center TimberStrand LSL blocking: 1 row at 10' 16' height 2 rows at 16' 24' height 3 rows at 24' 30' height 24" maximum Do not bevel cut joist beyond inside face of wall

ROOF DETAILS 7 Shear blocking: 1 1 8" TJ Rim Board, 1 1 4" TimberStrand LSL, or TJI joist V-cut shear blocking: 1 1 4" TimberStrand LSL rim board eb stiffener required on both sides at R1 ONLY eb stiffener required on both sides at R3 ONLY Beveled bearing plate required when slope exceeds 1 4:12 Variable slope seat connector R1 R1 1 3 adjacent span maximum R3 R3 1 3 adjacent span maximum Intermediate Bearing Blocking panels or shear blocking may be specified for joist stability at intermediate supports Beveled web stiffener required on both sides. Cut to match roof slope. eb stiffener required on both sides at R7 ONLY Twist strap and backer block required at R7S with slopes greater than 3:12. See Nailing Requirements, page 8. TJI joist flange must bear fully on plate 2'-0" maximum 2x4 block for soffit support Birdsmouth cut must not overhang inside face of plate Beveled bearing plate required when slope exceeds 1 4:12 R5 Birdsmouth cut allowed at low end of joist only R7 R7 R7 S

2 rows 8d (0.113" x 2 1 2") nails at 8" on center 4'-0" minimum 2x4 one side. Use 2x4 both sides if joist spacing is greater than 24" on-center. 4'-0" minimum 2x4 one side. Use 2x6 if joist spacing is greater than 24" on-center. 1 1 2" 10d (0.128" x 3") nails at 8" on-center 2'-0" maximum Beveled 2x4 block with beveled web stiffener on opposite side of web 2'-0" maximum Beveled web stiffener on both sides Beveled 2x4 block R8 Birdsmouth cut allowed at low end of joist only R9 Birdsmouth cut allowed at low end of joist only Filler 2 rows 8d (0.113" x 2 1 2") nails at 8" on center 4'-0" minimum 2x4 one side. Use 2x4 both sides if joist spacing is greater than 24" on-center 1 1 2" LSTA18 (Simpson or USP) strap with twelve 10d (0.148" x 1 1 2") nails Additional blocking may be required for shear transfer 2'-0" maximum Beveled bearing plate required when slope exceeds 1 4:12 Beveled 2x4 block. Second beveled web stiffener required on opposite side at R10 ONLY Double beveled bearing plate when slope exceeds 1 4:12 eb stiffener required on both sides at R14 ONLY Strap nails: Leave 2 3 8" minimum end distance, typical R10 R10 R14 R14

FRAMING CONNECTORS 8 APPROVED HANGERS The following manufacturers are approved to supply hangers for Trus Joist products: Simpson Strong-Tie Co., Inc.: 1-800-999-5099 USP Structural Connectors: 1-800-328-5934 Hanger design loads differ by support type and may exceed the capacity of the support and/or supported member. Contact your eyerhaeuser representative or refer to eyerhaeuser software. Top mount hanger Face mount hanger Hanger height must be a minimum of 60% of joist depth NAILING REQUIREMENTS Fill all round, dimple, and positive angle holes with the proper nails. Hanger nails are usually a heavier gauge because of the higher loads they need to carry. Unless specified otherwise, full capacity of straps or connectors can only be achieved if the following nail penetration is provided: FACE MOUNT TOP MOUNT 10d (0.148" x 1 1 2") 1 1 2" minimum 1 1 2" minimum 10d (0.148" x 3") 1 3 4" minimum 3" minimum 16d (0.162" x 3 1 2") 2" minimum 3 1 2" minimum Top mount hangers should be fastened to TJI joist headers with 10d (0.148" x 1 1 2") nails. Fasten face mount hangers to 3 1 2" or wider TJI joist headers with 10d (0.148" x 3") or 16d (0.162" x 3 1 2") nails. H1 H3 eb stiffeners required if the sides of the hanger do not laterally support at least 3 8" of the TJI joist top flange Flush bearing plate required. Maximum 1 4" overhang permitted at beam. CONNECTOR INSTALLATION AND SQUEAK PREVENTION TIPS Nails must be completely set. Leave 1 16" clearance between the member and the support member or hanger. Joist to beam connections require hangers; do not toenail. Seat the supported member tight to the bottom of the hanger. On Simpson Strong-Tie VPA connectors, bend the bottom flange tabs over and nail to TJI joist bottom flange. Reduce squeaks by adding subfloor adhesive to the hanger seat. LSTA24 (Simpson or USP) strap with twelve 10d (0.148" x 1 1 2") nails required at H5S with slopes greater than 3:12 Additional blocking may be required for shear transfer H5 H5S Strap nails: Leave 2 3 8" minimum end distance Variable slope joist hanger. Beveled web stiffener required on both sides.

Filler block: Attach with ten 10d (0.128" x 3") nails, clinched. Use ten 16d (0.135" x 3 1 2") nails from each side with TJI 560 joists. Backer block: Install tight to bottom flange (tight to top flange with top mount hangers). Attach with ten 10d (0.128" x 3") nails, clinched when possible. H6 H6S LSTA18 strap required at H6S with slopes greater than 3:12 Strap nails: Leave 2 3 8" minimum end distance Variable slope joist hanger. Beveled web stiffeners required on both sides. SHEAR BLOCKING AND VENTILATION HOLES (Roof Only) TJ Rim Board or TimberStrand LSL for shear blocking (between joists). Field trim to match joist depth at outer edge of wall or locate on wall to match joist depth. 1 3 1 3 1 3 1 2 For TJI joists with slopes of 10:12 to 12:12, the vertical depth of shear blocking at bearing will require 1 1 8" TJ Rim Board or 1 1 4" TimberStrand LSL that is one size deeper than the TJI joist. DO NOT use 1 1 8" TJ Rim Board in ventilation-hole applications. SB Maximum allowable V-cut 1 2 TJI JOIST NAILING REQUIREMENTS AT BEARING End Bearing (1 3 4" minimum bearing required) TJI Joist to Bearing Plate Intermediate Bearing (3 1 2" minimum bearing required) Blocking to Bearing Plate One 8d (0.113" x 2 1 2") nail each side, 1 1 2" minimum from end hen slope exceeds 1 4:12, a beveled bearing plate, variable slope seat connector, or birdsmouth cut (at low end of joist only) is required. Slopes 3:12 or less: One 8d (0.113" x 2 1 2") nail each side. See detail R7. Slopes greater than 3:12: Two 8d (0.113" x 2 1 2") nails each side, plus a twist strap and backer block. See detail R7S. hen slope exceeds 1 4:12 for a 2x4 wall or 1 8:12, for a 2x6 wall, a beveled bearing plate or variable slope seat connector is required. 1 1 8" TJ Rim Board or 1 1 4" TimberStrand LSL: Toenail with 10d (0.131" x 3") nails at 6" on-center or 16d (0.135" x 3 1 2") nails at 12" on-center TJI joist blocking: 10d (0.128" x 3") nails at 6" on-center Shear transfer nailing: Minimum, use connections equivalent to nail schedule

BEAM AND COLUMN DETAILS 9 Bearing length is extremely critical and must be considered for each application. See Minimum Bearing Length table below for minimum end and intermediate bearing lengths, and your Javelin framing plan, if applicable. L1 Rim board or blocking for lateral support Cut only round holes and only in the center of beam (see Allowable Holes, page 2) This guide is intended for the products shown in dry-use conditions L3 Top mount hanger Parallam PSL or TimberStrand LSL column with column cap L5 P1 Parallam PSL or TimberStrand LSL column Intermediate support P2 Span If short span is less than 1 3 of adjacent span, additional consideration may be required L2 Strap per code if top plate is not continuous over header Face mount hanger L3 Protect untreated wood from direct contact with concrete L4 Optional non-shrink grout P3 hen fasteners are required on both sides, stagger fasteners on the second side so they fall halfway between fasteners on the first side. L6 Multiple pieces can be nailed or bolted together, up to a maximum width of 7" MULTIPLE-MEMBER CONNECTIONS FOR SIDE-LOADED BEAMS Additional nailing or bolting may be required with side-loaded multiple- member beams. Refer to current product literature. MULTIPLE-MEMBER CONNECTIONS FOR TOP-LOADED BEAMS Load must be applied evenly across entire beam width. Otherwise, use connections for side-loaded beams. Piece idth 1¾" # of Plies 2 3 4 31 2" 2 Fastener Type (1) Min. Length # Rows O.C. Spacing Location 10d nails 3" 3 (2) 12" 12d 16d nails 31 4" 2 (2) One side Screws 3 3 8" or 3½" 2 24" 10d nails 3" 3 (2) 12d 16d nails 31 4" 2 (2) 12" Both sides Screws 3 3 8" or 3½" Both sides 2 24" 5" One side 10d nails (3) 3" 3 (2) One side 12" 12d 16d nails (3) 31 4" 2 (2) (per ply) Screws 5" or 6" Both sides 2 24" 6¾" One side Screws 5" or 6" Both sides 2 24" 6¾" One side 1 2" bolts 8" 2 24" (1) 10d nails are 0.128" diameter; 12d-16d nails are 0.148" 0.162" diameter; screws are SDS, SD, USP S, or TrussLOK. (2) An additional row of nails is required with depths of 14" or greater. (3) hen connecting 4-ply members, nail each ply to the other and offset rows by 2" from the rows in ply below.

Beam and header details L1 bearing at wood wall L2 bearing for door or window header L3 beam to beam connection DETAIL SCHEDULE L4 bearing at concrete wall L5 bearing at wood or steel column L6 connection of multiple pieces Column details P1 P2 P3 beam on column cap column base elevated column base BEAM AND HEADER BEARINGS Minimum Bearing Length for Beams and Headers Beam Depth Bearing Span of Header or Beam 4' 6' 8' 10' 12' 16' 20' 24' 28' 5 1 2" End/Int. 2 1 4" / 4 1 2" 1 1 2" / 3 1 2" 1 1 2" / 3 1 2" 1 1 2" / 3 1 2" 1 1 2" / 3 1 2" 7 1 4" End/Int. 3 1 2" / 6 1 4" 2 1 4" / 5 1 2" 1 3 4" / 4 1 4" 1 1 2" / 3 1 2" 1 1 2" / 3 1 2" 1 1 2" / 3 1 2" 8 5 8" End/Int. 3 1 2" / 8 1 2" 2 1 4" / 5 3 4" 1 3 4" / 4 1 4" 1 1 2" / 3 1 2" 1 1 2" / 3 1 2" 1 1 2" / 3 1 2" 1 1 2" / 3 1 2" 1 1 2" / 3 1 2" 9 1 4", 9 1 2" End/Int. 4 1 4" / 8" 3 1 4" / 7 1 2" 2 1 2" / 6 1 4" 2" / 5 1 4" 1 1 2" / 4" 1 1 2" / 3 1 2" 1 1 2" / 3 1 2" 1 1 2" / 3 1 2" 11 1 4", 11 7 8" End/Int. 4" / 9 1 4" 3 1 4" / 8" 2 1 4" / 6" 1 3 4" / 4 3 4" 1 1 2" / 4" 1 1 2" / 3 1 2" 14" End/Int. 4 1 2" / 10 3 4" 3 1 4" / 8 1 4" 2 1 2" / 6 1 2" 2" / 5 1 2" 1 3 4" / 4 3 4" 16" End/Int. 4 1 4" / 10 1 2" 3 1 4" / 8 1 2" 2 3 4" / 7" 2 1 4" / 6" 18" End/Int. 4 1 4" / 10 1 2" 3 1 4" / 8 3 4" 2 3 4" / 7 1 2" 20" End/Int. 4 1 4" / 10 3 4" 3 1 2" / 9 1 4" Minimum bearing length: 1 1 2" at ends, 3 1 2" at intermediate supports. Bearing across full beam width is required. Bearing lengths shown are based on bearing stress for TimberStrand LSL, Microllam LVL, or Parallam PSL. If the support member s allowable bearing stress is lower (e.g., when bearing on a flat wood plate), bearing lengths may need to be increased. Table assumes maximum allowable uniform load. For other conditions, contact your eyerhaeuser representative. Beams and headers require lateral support at bearing points and along the top (or compression edge) at 24" on-center or closer. 1 3 4"-thick members that are 16" or deeper must be used in multiple-ply units only. DO NOT overhang seat cuts on beams beyond inside face of support member 1 1 8" TJ Rim Board or 1 1 4" TimberStrand LSL Beam Attachment at Bearing One 10d (0.128" x 3") nail each side of member at bearing, 1 1 2" minimum from end Drive nails at an angle to minimize splitting of plate

TrusJoist.com 888.453.8358 TrusJoist.com 888.453.8358 TrusJoist.com 888.453.8358 1 8 0 4 8 12 16 20 24 28 32 36 40 20 18 16 14 12 10 8 6 4 2 0 1 4 OUR GUARANTEE For conditions not shown in this guide, or other assistance, contact youreyeraheuser representative or call 1-888-453-8358 CODE EVALUATIONS, See TJI Joists ICC ES ESR-1153 CCMC 13132-R pending TimberStrand LSL ICC ES ESR-1387 CCMC 12627-R Parallam PSL ICC ES ESR-1387 CCMC 11161-R Microllam LVL ICC ES ESR-1387 CCMC 08675-R TJ Rim Board ICC ES ESR-1387 CCMC 13261-R ARNING: Drilling, sawing, sanding or machining wood products generates wood dust. The paint and/or coatings on this product may contain titanium dioxide. ood dust and titanium dioxide are substances known to the State of California to cause cancer. For more information on Proposition 65, visit wy.com/inform. PRODUCT STORAGE Store and handle joists in vertical orientation. Have a damaged joist or beam? File a damage report online for prompt service from your regional technical office. Scan the QR code with your smartphone or go to woodbywy.com/support. Protect products from sun and water. CAUTION: rap is slippery when wet or icy. TrusJoist.com 888.453.8358 TrusJoist.com 888.453.8358 TrusJoist.com 888.453.8358 Use support blocks at 10' on-center to keep products out of mud and water. TrusJoist.com 888.453.8358 Align stickers directly over support blocks. woodbywy.com May 2013 Reorder TJ-9001 This document supersedes all previous versions. If this is more than one year old, contact your dealer or eyerhaeuser rep., eyerhaeuser, Javelin, Microllam, Parallam, TimberStrand, TJ, TJI, and Trus Joist are registered trademarks and Edge Gold is a trademark of eyerhaeuser NR. 2013 eyerhaeuser NR Company. All rights reserved. Printed in the USA.