Measurement of channel depth by using a general microscope based on depth of focus

Similar documents
General Physics Experiment 5 Optical Instruments: Simple Magnifier, Microscope, and Newtonian Telescope

Indian Institute of technology Madras Presents NPTEL NATIONAL PROGRAMME ON TECHNOLOGY ENHANCED LEARNING

Biology 29 Cell Structure and Function Spring, 2009 Springer LABORATORY 1: THE LIGHT MICROSCOPE

Applications of Optics

MICROSCOPE LAB. Resolving Power How well specimen detail is preserved during the magnifying process.

Geometric Optics. This is a double-convex glass lens mounted in a wooden frame. We will use this as the eyepiece for our microscope.

Chapter 18 Optical Elements

Advanced 3D Optical Profiler using Grasshopper3 USB3 Vision camera

EE119 Introduction to Optical Engineering Fall 2009 Final Exam. Name:

Optical System Design

Physics 208 Spring 2008 Lab 2: Lenses and the eye

Microbiology Laboratory 2

VISUAL PHYSICS ONLINE DEPTH STUDY: ELECTRON MICROSCOPES

ECEN 4606, UNDERGRADUATE OPTICS LAB

ECEN 4606, UNDERGRADUATE OPTICS LAB

Asia Microreactors Datasheet

PHYS 160 Astronomy. When analyzing light s behavior in a mirror or lens, it is helpful to use a technique called ray tracing.

Optical design of a high resolution vision lens

Readings: Hecht, Chapter 24

Measurement of Surface Profile and Layer Cross-section with Wide Field of View and High Precision

Basics of Light Microscopy and Metallography

REFLECTION THROUGH LENS

Supplementary Figure 1 Reflective and refractive behaviors of light with normal

Lenses. Optional Reading Stargazer: the life and times of the TELESCOPE, Fred Watson (Da Capo 2004).

This experiment is under development and thus we appreciate any and all comments as we design an interesting and achievable set of goals.

Be aware that there is no universal notation for the various quantities.

CHAPTER TWO METALLOGRAPHY & MICROSCOPY

MICROSCOPY MICROSCOPE TERMINOLOGY

GEOMETRICAL OPTICS Practical 1. Part I. BASIC ELEMENTS AND METHODS FOR CHARACTERIZATION OF OPTICAL SYSTEMS

Light Microscopy. Upon completion of this lecture, the student should be able to:

COTTON FIBER QUALITY MEASUREMENT USING FRAUNHOFER DIFFRACTION

Activity 6.1 Image Formation from Spherical Mirrors

PHYSICS FOR THE IB DIPLOMA CAMBRIDGE UNIVERSITY PRESS

Conformal optical system design with a single fixed conic corrector

A BRIEF INTRODUCTION TO MICROSCOPY The two key properties of a microscope that allow you to see microbes are resolution and magnification.

Lithography. 3 rd. lecture: introduction. Prof. Yosi Shacham-Diamand. Fall 2004

Droplets Generation with 3D Printed Chip

Name:.. KSU ID:. Date:././201..

OPTICAL SYSTEMS OBJECTIVES

Lecture 2: Geometrical Optics. Geometrical Approximation. Lenses. Mirrors. Optical Systems. Images and Pupils. Aberrations.

SENSOR+TEST Conference SENSOR 2009 Proceedings II

Computer Generated Holograms for Optical Testing

Care and Use of the Compound Light Microscope

Laboratory 7: Properties of Lenses and Mirrors

Basic Microscopy. OBJECTIVES After completing this exercise, you should be able to do the following:

Lecture 2: Geometrical Optics. Geometrical Approximation. Lenses. Mirrors. Optical Systems. Images and Pupils. Aberrations.

The microscope is useful in making observations and collecting data in scientific experiments. Microscopy involves three basic concepts:

Linewidth control by overexposure in laser lithography

Design, Fabrication and Characterization of Very Small Aperture Lasers

DIMENSIONAL MEASUREMENT OF MICRO LENS ARRAY WITH 3D PROFILOMETRY

Marine Invertebrate Zoology Microscope Introduction

Chapter 36. Image Formation

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G

Components of the Microscope

The Stereomicroscope CHAPTER 1

There is a range of distances over which objects will be in focus; this is called the depth of field of the lens. Objects closer or farther are

Three-dimensional quantitative phase measurement by Commonpath Digital Holographic Microscopy

Development of a new multi-wavelength confocal surface profilometer for in-situ automatic optical inspection (AOI)

30 Lenses. Lenses change the paths of light.

Life Science Chapter 2 Study Guide

Instruction Manual T Binocular Acromat Research Scope T Trinocular Acromat Research Scope

CALIBRATION OF MICROSCOPE EYEPIECE GRATICULE

Physics 431 Final Exam Examples (3:00-5:00 pm 12/16/2009) TIME ALLOTTED: 120 MINUTES Name: Signature:

PHYSICS. Chapter 35 Lecture FOR SCIENTISTS AND ENGINEERS A STRATEGIC APPROACH 4/E RANDALL D. KNIGHT

BA310POL ADVANCED POLARIZATION MICROSCOPE

Supplementary Materials for

Image Formation. Light from distant things. Geometrical optics. Pinhole camera. Chapter 36

EXPERIMENT 4 INVESTIGATIONS WITH MIRRORS AND LENSES 4.2 AIM 4.1 INTRODUCTION

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION

Chapter 25. Optical Instruments

Bringing Answers to the Surface

Chapters 1 & 2. Definitions and applications Conceptual basis of photogrammetric processing

Metrology Prof. Dr Kanakuppi Sadashivappa Bapuji Institute of Engineering and Technology Davangere. Lecture 24 Measurement of Screw Thread Element

Lecture 20: Optical Tools for MEMS Imaging

E X P E R I M E N T 12

DIY fabrication of microstructures by projection photolithography

Average: Standard Deviation: Max: 99 Min: 40

EXPRIMENT 3 COUPLING FIBERS TO SEMICONDUCTOR SOURCES

Laboratory Introduction

Parameter Optimization by Taguchi Methods for Polishing LiTaO3 Substrate. Using Force-induced Rheological Polishing Method

Chapter 36. Image Formation

Using a Compound Light Microscope

CHAPTER 5 FINE-TUNING OF AN ECDL WITH AN INTRACAVITY LIQUID CRYSTAL ELEMENT

The light microscope

Broadband transition between substrate integrated waveguide and rectangular waveguide based on ridged steps

microscopy A great online resource Molecular Expressions, a Microscope Primer Partha Roy

Match the microscope structures given in the left column with the statements in the right column that identify or describe them.

used for low power magnification of a sample image is 3 dimensional

Lecture Outline Chapter 27. Physics, 4 th Edition James S. Walker. Copyright 2010 Pearson Education, Inc.

Profile Measurement of Resist Surface Using Multi-Array-Probe System

Burton's Microbiology for the Health Sciences

Supplementary Figure 1. GO thin film thickness characterization. The thickness of the prepared GO thin

Basic Microscopy for Plant Biology

Broadband and Gain Enhanced Bowtie Antenna with AMC Ground

Aberrations of a lens

Physics 11. Unit 8 Geometric Optics Part 2

Chapter 25 Optical Instruments

Point Spread Function Estimation Tool, Alpha Version. A Plugin for ImageJ

Optical Design of an Off-axis Five-mirror-anastigmatic Telescope for Near Infrared Remote Sensing

Waves & Oscillations

Transcription:

Eurasian Journal of Analytical Chemistry Volume, Number 1, 007 Measurement of channel depth by using a general microscope based on depth of focus Jiangjiang Liu a, Chao Tian b, Zhihua Wang c and Jin-Ming Lin a,b a Department of Chemistry, Tsinghua University, Beijing 100084, China b State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Centre for Eco- Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China c State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology, Beijing 10009, China Abstract This paper presents a simple and rapid method to measure the depth of the channel of microfluidic chip. With the depth of focus (DOF) low to few micro-meters, general microscopes show the strong axial (or longitudinal) resolving power. With the assistant of fine-adjustment, the objective was controlled accurately to focus on the channel side and channel bed respectively. Then the depth was calculated from the scales that fine adjustments turned. Experiments results demonstrated the possibilities of depth measurement with normal microscope. Compared with other methods, this method showed high degree of precision with a deviation less than 0.6µm while the magnification was 100X. This method is rapid, simple and reliable, and it is very suitable for monitoring the etching process to optimize the function of microfluidic chip. Keywords: Microfluidic device / measurement/ depth/ microscope/ depth of focus 1. Introduction Microfluidic chip was developed rapidly over the past decades due to the unique advantages of small reagent consumption, short analysis time, as well as small dimension, high integration[1-3]. With the improvements of fabrication technique, more and more components are integrated into microchip to perform complicated function (e.g., micro valves and pumps). The dimensions of microstructure fabricated are normally at micrometer levels. For some microstructures etched on glass, high dimensional accuracy is required to ensure Copyright 007 by MOMENT ISSN: 1306-3057

Eurasian J. Anal. Chem. / Vol:, No:1, 007 13 the implementation of the function. So it is necessary to monitor and control the dimensions of structure during the etching process. The stylus profiler is usually employed in characterizing microfluidic structures. It is a high resolution tool which contacts the surface to be measured and then moves across the surface at a constant velocity to obtain surface height variation. However, some distortions occur in the profile curve at the near vertical channel edges because of the limited resolution and imperfections in the shape of the stylus tip. Distortions may also occur to samples fabricated from relatively soft substrates using the stylus profiler. And moreover, currently the stylus is not a common and cheap enough instrument for normal analytical laboratories. A new simple and indirect method was developed based on a combination of poly(dimethylsiloxane) (PDMS) replication and charge coupled device (CCD) imaging[4]. Despite reliability, non-destructivity, and cheapness and simpleness of this method, it is time-consuming and not convenient for checking the channel size while etching the glass mode. At least one and a half hours were taken on the preparation and polymerization of PDMS prepolymer. Fletcher et al. developed a method for the quantitative 3-dimensional profiling of micro channel networks within optically transparent microfluidic device by capturing digitized microscope images of the channel network filled with an optically absorbing dye[5]. Although this method is accurate and non-destructive technique, it has the limitation that the microfluidic chip must be transparent and the channels are solution-filled. And it is not convenient for a non-bonded chip, the non-bonded chip needs to be cleaned and covered with a cover plate to fill the solution. Here, we introduced a simple, rapid, non-destructive method to measure the depth of channel only by using a common microscope without a requirement of optical transparency of microfluidic chip. For common analytical laboratories, measurements of depth of channel were realized conveniently and rapidly with this method. The measurement can be finished in one minute, so it is highly suitable for monitoring the depth of channel during wet etching. The principle was described in this paper, and this method was demonstrated to be reliable and effective by experiments results.. Principle Since its invention, the microscope has been a valuable tool in the development of scientific theory. A compound microscope is composed of two elements; a primary magnifying lens and a secondary lens system, similar to a telescope. Light is caused to pass

14 Liu, Tian, Wang & Lin through an object and then focused by the primary and secondary lens. The function of microscope is to enhance resolution. When considering resolution in optical microscopy, a majority of the emphasis is placed on point-to-point lateral resolution in the plane perpendicular to the optical axis (Fig.1). Another important aspect to resolution which was neglected all the times is the axial (or longitudinal) resolving power of an objective, which is measured parallel to the optical axis and is most often referred to as depth of focus (DOF). Depth of focus (DOF) is the range of object plane position at which the image can be viewed without appearing out of focus for a fixed position of object. The formula is: 1 DOF = λ [ n ( N. A.) ] /( N. A.) + (50/ M ) (1) Where the λ is the wave length, n is the index of refraction, N.A. is the numerical aperture of the object, M is the total magnification of the optical system. Fig.1 (A) General microscope structure; (B) Fine-adjustment with scales which was employed to calculate the distance that objectives moved down; (C) Focus on the channel side plane and channel bed plane respectively, the distance that objectives moved down corresponded to the depth of channels. Table 1 presents calculated variations in the depth of focus (DOF) of microscope in our lab (XSJ-, Chongqing Optical and Electrical Instruments Co., Ltd., Chongqing, China) in a series of objectives with increasing numerical aperture and magnification. With 100X magnification, the depth of focus is limited into only 0.48 µm. It means that only when the object plane was placed within this narrow range, the object can be viewed no loss of sharpness. Hence based on depth of focus, the microscope could be employed to measure the depth of micro channels. The pivotal procedure is that focus the microscope on the open

Eurasian J. Anal. Chem. / Vol:, No:1, 007 15 channel side plane and channel bed plane respectively. The distance that objectives moved down corresponded to the depth of channel. Table 1. Depth of focus calculated in a series of objectives. (Using a eyepiece 10X, λ=550nm) Magnification Numerical Aperture Depth of Focus (µm).5x 0.07 511.97 4X 0.10 10.97 10X 0.5 33.5 5X 0.40 7.15 40X 0.65.55 100X 1.5 0.48 3. Experimental A normal optical microscope (XSJ-, Chongqing Optical and Electrical Instruments Co., Ltd., Chongqing, China) coupled with a CCD camera (SDC-313, Samsung, China) was employed for measuring structural dimensions. The glass chip was placed flat on the X Y adjustable stage of the microscope and illuminated by a halogen lamp. Slowly turn the coarse adjustment until top layer comes into focus. Then use the fine adjustment for fine focusing. The sharp image can be estimated from oculars or CCD camera by human eyes. Then move down the objective, let the bottom come into focus. Calculate the scales the fine adjustment rotates. The depth was obtained by scale-to-length function. The reliability of this method was studied by employing another direct method as comparison. The microfluidic chip was prepared by breaking across the channel and placed on the stage of the stereo zoom microscopes coupled with a digital camera (K700L, Motic China Group Co., Ltd., China). The images of cross section of channels were captured by digital camera as Fig. shows. The dimension data of channel was evaluated from the cross section image with the analysis software Motic Image Plus. Fig. The cross view image of channel captured by digital camera while the chip was break cross the channel. With the assistant of the analysis software of microscope, the depth of channel was measured with high precision.

16 Liu, Tian, Wang & Lin 4. Results and discussion 4.1 Measurement of Channel depth based on low DOF There is direct relationship between the scales that fine adjustment of microscope is turned and the distance which the objectives move down. The distance corresponds to channel depth d. The depth d is given by following equation: d = ε A () Where d is the depth, A is the scales which fine adjustment turned, ε is the coefficient. To obtain ε, a series of samples were measured as follows. Glass chip were break across the channel. The depth of channels was obtained from cross section image with assistant of analysis software. The thickness of an about 110 µm cover glass was selected as a sample also whose thickness was measured using a micrometer. To obtain the scales which fine adjustment turned, a series of measurements based on DOF were carried out. Fig.3 shows plots of A versus depth of the channel, the A was proportional to depth of channel. From these results, we obtained the coefficient ε and the equation as follows: d = 1.0037A + 0.305 Fig. 3 (A) The micro dusts on the surface were sharply imaged while in the range of depth of focus with magnification of 100X. (B) The image became blurred obviously while objectives moved down 1µm more. After the coefficient ε was evaluated as 1.0037, this method was applied to actual sample measurement to prove the reliability. A microfluidic chip with five channels had been etched for 5 min, 10 min, 30 min, 50 min, and 70 min respectively. Fig. is a CCD crosssectional image of the glass chip prepared by breaking the chip across the channel. Results from channel depth measurements using the microscope based on DOF are listed in Table. Because the micro distance between the objective and the focus plane with high magnification, the magnification of 40X was selected to avoid objective contacting with the top layer while focusing on the channel bottom. In Table, relative standard deviations of the measurements were within 3%, with a clear tendency of the precision to improve at larger

Eurasian J. Anal. Chem. / Vol:, No:1, 007 17 dimensions. Results obtained for the same sample using a measuring microscope are also listed in the table for comparison. The results agreed well, with an absolute deviation of less than 0.9 µm. Although the precision of this method is slightly worse, the precision and accuracy is sufficient for the characterization of most microfluidic structures at micrometer levels. Table. Comparison of measurements for the dimensions of sample channels using this method, and cross section view of channel method with digital camera. Sample No. This method(dof) Cross section Magnification µm RSD µm RSD Deviation µm 1 100X 7.1.8% 7.4.6% 0.3 100X 15. 1.9% 14.6 1.0% 0.6 3 40X 43.6.0% 44.3 1.% 0.7 4 40X 66.4.4% 67.5 0.4% 1.1 5 40X 105.4 1.7% 104.8 0.6% 0.6 4. Precision of this method The precision depends on the procedure of focusing on the surface to obtain a sharp image. And the precision of the focus depends on the depth of the focus. In theory, the error of measurements was no more than DOF. With high power objectives high precision could be obtained up to 0.48 µm. However, normally the microfluidic chips are made of glass materials or other optically transparent material. It is difficult to distinguish in-focus and outfocus statuses. No sharp image could be obtained if the surface was smooth and clean absolutely. Fortunately the dust and the channel roughness helped us to determine the focus as Fig.3 shows. Fig.3 illustrated the difference of sharp image and blurred image, image A was taken by CCD under the 100X objectives while the object was placed in the range of DOF, image B was taken while the object was 1µm out of DOF range. It is evident that image B was less of sharpness. Normally, the dusts and roughness were with dimension less than 1µm. By selecting appropriate dusts, the precision of focusing could be enhanced near to the level of DOF.

18 Liu, Tian, Wang & Lin 140.0 Fine adjustment scales 10.0 100.0 80.0 60.0 40.0 0.0 y = 0.996x + 0.49 R = 0.9994 0.0 0.0 0.0 40.0 60.0 80.0 100.0 10.0 140.0 Depth(µm) Fig.4 Scales fine adjustment turned while measuring depth the channel versus the depth of channel. There was good linearity in the range 10µm ~110µm (linearity coefficient R = 0.9994µm). 4.3 Monitor of etching process Due to the property of rapidness and convenience, this method was applied in etching process monitoring. The variation of fitted depth of channel with etching time is shown in Fig.4 which indicates that the average etch rate is equal to 1.45 µm/min. The linearity is good in despite of a slight tendency of rate increasing, it indicates that the etch rate is approximately constant. The total monitoring procedure was simple, rapid and nondestructive. 140.0 10.0 100.0 y = 1.4601x - 0.674 R = 0.9919 Depth/µm 80.0 60.0 40.0 0.0 0.0 0 0 40 60 80 Etching time/min Fig.5 Variation of channel depth versus etching time. The etch rate was approximately a constant of 1.45 µm/min.

Eurasian J. Anal. Chem. / Vol:, No:1, 007 19 5. Conclusion We have demonstrated a convenient, reliable and rapid method for measurement of depth of channels based on the resolution power of general microscope in axial direction. Each measurement could be accomplished in less than 1 min. Although the precision of this method was not better than other methods, it is nevertheless obvious that it is enough for application at micrometer level. It is very useful for common labs to optimize the function of channels. Acknowledgements This work was supported by the National Nature Science Foundation of China (No. 0575008, 043700). References 1. Reyes D R, Iossifidis D, Auroux P A and Manz A. (00) Micro Total Analysis Systems. 1. Introduction, Theory, and Technology. Anal. Chem. 74: 63.. Auroux P A, Iossifidis D, Reyes D R and Manz A. (00) Micro Total Analysis Systems.. Analytical Standard Operations and Applications. Anal. Chem. 74: 637. 3. Vilkner T, Janasek D and Manz A. (004) Micro Total Analysis Systems. Recent Developments. Anal. Chem. 76: 3373. 4. Dai J, Guan Y X, Wang S L, Wu Z Y and Fang Z L (005) Feature characterization of microfabricated microfluidic chips by PDMS replication and CCD imaging. Anal. Bioanal. Chem. 381: 839. 5. Broadwell I, Fletcher P D I, Haswell S J, McCreedy T and Zhang X (001) Quantitative 3-dimensional profiling of channel networks within transparent lab-on-achip microreactors using a digital imaging method. Lab Chip, 1: 66. Received: 8 December 006; Accepted: 05 February 007

0 Liu, Tian, Wang & Lin Jin-Ming Lin Corresponding Author Chao Tian Jiangjiang Liu Zhihua Wang Dr., Proffesor at the Tsinghua University, China. Address: State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China Address: Department of Chemistry, Tsinghua University, Beijing 100084, China E-mail: jmlin@mail.rcees.ac.cn Dr., Proffesor at the Chinese Academy of Sciences, China. Address: State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China Dr., Proffesor at the Tsinghua University, China. Address: Department of Chemistry, Tsinghua University, Beijing 100084, China Dr., Proffesor at the Beijing University of Chemical Technology, China. Address: State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology, Beijing 10009, China