Current ON state current ma minimum, 6 ma typical, 10 ma maximum OFF state current ma maximum

Similar documents
NI PXI-2521 Specifications 40-Channel DPST Relay Module

NI PXI-2520 Specifications 80-Channel SPST Relay Module

NI PXI-2797 Specifications 40 GHz 6 1 Terminated 50 Ω Multiplexer

SCXI MHz Quad 8x1 50 Ω Multiplexer

NI 2865A 0.3 A Matrix Cards for NI SwitchBlock

NI PXI-2557 Specifications

NI PXI/PXIe-2540 Specifications

Input Characteristics. Measurement Range. SPECIFICATIONS NI PXIe-4357

1- or 2-Port, High-Speed, Flexible Data Rate PXI CAN Interface Module

NI PXI-2555 Specifications

NI PXI/PXIe-2541 Specifications 300 MHz Ω Matrix

Power Amplifier. Input Characteristics. SPECIFICATIONS NI PXIe-4610 Power Amplifier. Signal Range

1- or 2-Port, Software-Selectable PXI CAN Interface Module

NI PXI/PXIe-2529 Specifications

NI PXIe Contents. About These Specifications DEVICE SPECIFICATIONS. 3 GHz Ω Multiplexer (SP16T)

NI PXI Contents DEVICE SPECIFICATIONS. RF Attenuator

NI 6731/6733 Specifications

NI PXIe-5630 Specifications

NI PXI Contents. About These Specifications DEVICE SPECIFICATIONS GHz Dual Transfer Switch 50 Ω Relay Module

NI SCXI Specifications

PXI Contents. PXI-2585 Specifications. Topology DEVICE SPECIFICATIONS. 10-Channel Multiplexer

Refer to the NI Switches Help at ni.com/manuals for detailed topology information.

Analog Characteristics

NI PXI/PXIe-2532 Specifications

High-Speed/Flexible Data-Rate CAN Characteristics 5 VDC

NI PXI/PXIe-2527 Specifications

USRP Contents. Definitions. Conditions SPECIFICATIONS. Software Defined Radio Device

NI PXI-2530 Specifications

PXIe Contents SPECIFICATIONS. RF Preselector Module

NI PXIe-5601 Specifications

USRP Contents. Definitions. Conditions SPECIFICATIONS. Software Defined Radio Device

USRP Contents. Definitions. Conditions SPECIFICATIONS. Software Defined Radio Reconfigurable Device

USRP Contents. Definitions SPECIFICATIONS. Software Defined Radio Reconfigurable Device

PXIe Contents SPECIFICATIONS. RF Amplifier

PXI Contents. Definitions SPECIFICATIONS. ±100 V, 2 W Precision PXI Source Measure Unit. These specifications apply to the PXI-4132.

Analog Input. DEVICE SPECIFICATIONS NI PXIe-4300

PXI Contents SPECIFICATIONS. ±20 V, 40 W PXI Source Measure Unit

USRP Contents. Definitions SPECIFICATIONS. 50 MHz to 2.2 GHz Tunable RF Transceiver

NI 6143 Specifications

PXI Contents SPECIFICATIONS. 1.3 GHz RF Analog Signal Generator

DEVICE SPECIFICATIONS NI PXIe Ch, 24-bit, 25.6 ks/s Simultaneous AC LVDT Input Module

CDA Contents. Definitions SPECIFICATIONS. Clock Distribution Device

USRP Contents. Definitions SPECIFICATIONS. 10 MHz to 6 GHz Tunable RF Transceiver

PXI Contents SPECIFICATIONS. 6.6 GHz RF Analog Signal Generator

PXI Contents. PXI-2584 Specifications DEVICE SPECIFICATIONS. 300 V CAT II, 600 V CAT I Multiplexers

NI PXI/PXIe Contents DEVICE SPECIFICATIONS. 40 A Fault Insertion Unit

PXIe Contents SPECIFICATIONS. 3.3 GHz RF Analog Signal Generator

100 MHz Bandwidth, 12-Bit PXI Waveform Generator

PXIe Contents. Definitions SPECIFICATIONS. 8.5 GHz Vector Network Analyzer

NI PXI/PXIe Contents. About These Specifications DEVICE SPECIFICATIONS. Quad 2 1 Terminated Multiplexer

NI PXI/PXIe Contents DEVICE SPECIFICATIONS. 10 A Fault Insertion Unit

PXIe, 24-Channel, ±24 V, 50 ma Precision PXI Source Measure Unit

NI PXI-2532 Specifications

PXIe Contents. Definitions SPECIFICATIONS. 8.5 GHz Vector Network Analyzer

OPERATING INSTRUCTIONS NI Port, Low-Speed/Fault Tolerant CAN Module

4-Channel, ±6 V, 500 ma Precision PXI Source Measure Unit

4-Channel, ±24 V, 150 ma PXI Source Measure Unit

PXIe Contents SPECIFICATIONS. 250 khz to 20 GHz RF Analog Signal Generator

4-Channel ±10 V, 100 ma, Precision PXI Source Measure Unit

NI 6238/6239 Specifications

DEVICE SPECIFICATIONS NI PXIe-4302/ Ch, 24-bit, 5 ks/s or 51.2 ks/s Simultaneous Filtered Data Acquisition Module

SPECIFICATIONS PXIe channel, 16-bit, 400 ks/s/ch, Ch-Ch Isolated Analog Input Module. ni.com/manuals

4-Channel ±10 V, 100 ma, Precision PXI Source Measure Unit

4-Channel, ±24 V, 150 ma Precision PXI Source Measure Unit

PXIe Contents SPECIFICATIONS. 2-Channel, 60 V, 1 A PXI Programmable Power Supply. These specifications apply to the PXIe-4112.

Related Information Refer to the NI Switches Help for detailed topology information.

NI USB Contents DEVICE SPECIFICATIONS. 50 MS/s Bus-Powered USB Oscilloscope

if it is used in a manner not described in the user documentation.

SA1500X. Operating Basics. Cautions DEVICE SPECIFICATIONS. High Impedance Active Probe

16-Bit, 120 MS/s, 12 Channel DC/16 Channel AC Receiver Adapter Module

DEVICE SPECIFICATIONS Phase Matrix PXI GHz PXI Vector Signal Analyzer

This document lists the specifications for the NI PXI The PXI-5900 is a differential amplifier.

is used in a manner not described in the user documentation.

DEVICE SPECIFICATIONS NI PXIe-4304/ Ch, 24-bit, ±42 V, 5 ks/s or 51.2 ks/s Simultaneous Filtered Data Acquisition Module. ni.

Note Using the NI 5751/5751B in a manner not described in this document may impair the protection that the NI 5751/5751B provides.

SPECIFICATIONS PXIe Ch (8 ADC), 2 MS/s, bit, Flexible Resolution PXI Analog Input Module

PXIe, 6½-Digit, ±300 V, Onboard 1.8 MS/s Isolated Digitizer,PXI Digital Multimeter

NI 6023E/6024E/6025E Family Specifications

PXIe Contents SPECIFICATIONS. ±60 V, 3 A System PXI Source Measure Unit. These specifications apply to the PXIe-4138.

NI PXIe-5663 Specifications

USRP Contents. Definitions SPECIFICATIONS. USRP Software Defined Radio Stand-Alone Device

Related Information Refer to the NI Switches Help for detailed topology information.

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9207E 16-Channel, ±20 ma/±10 V, 24-Bit Analog Input Module

PXIe Contents SPECIFICATIONS. ±200 V, 1 A System PXI Source Measure Unit. These specifications apply to the PXIe-4136.

GETTING STARTED GUIDE NI AI, ±10 V, 24 Bit, 50 ks/s/ch Simultaneous

Analog Input SPECIFICATIONS NI 6320/6321/6323

Specifications for the NI PXI/PCI-6552/6551

GETTING STARTED GUIDE NI khz to 100 MHz, 50 Ω, AC Coupled RF Receiver Module

NI roborio. Contents. Processor SPECIFICATIONS. RIO Device for Robotics

100-SPST (latching), 50-DPST. Refer to the NI Switches Help at ni.com/manuals for detailed topology information.

GETTING STARTED GUIDE NI AI, ±5 V, 24 Bit, 51.2 ks/s/ch Simultaneous, AC/DC Coupling, IEPE AC Coupling

6½-Digit, ±300 V, 1.8 MS/s Isolated Digitizer Included, PCI Digital Multimeter Device

PCI Express, 6½-Digit, ±300 V Digital Multimeter Device

Note Using the PXIe-5785 in a manner not described in this document might impair the protection the PXIe-5785 provides.

NI DAQPad -6020E Family Specifications

SCC-CO20 Isolated Current Output Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9853E 2-Port, High-Speed CAN Module

DATASHEET NI Channel, 250 V Sinking Digital Input Module

NI 6013/6014 Family Specifications

Terminology. Output Characteristics. DEVICE SPECIFICATIONS NI PXIe-4463 DSA Analog Output. ni.com/manuals

Transcription:

DEVICE SPECIFICATIONS NI 6624 This document lists the specifications for the NI PCI/PXI-6624 device. These specifications are typical at 25 C unless otherwise noted. Refer to the NI 6624 User Manual for more information about NI 6624 devices. Power Power requirement... 0.75 A from +5 V rail; 0.15 A from +3.3 V rail Isolated Inputs Number of input channels... 26 (3 per counter and 2 extra PFIs) Input type... Driven reference to either supply or ground (two terminals per input) Maximum input frequency... 400 khz Minimum input pulse width... 1 µs Input waveform types... Any Voltage Voltage range... Up to 48 VDC Typical ON voltage... 2.5 V Guaranteed ON voltage... 4.1 V Guaranteed OFF voltage... 0.8 V Current ON state current... 2.2 ma minimum, 6 ma typical, 10 ma maximum OFF state current... 0.1 ma maximum Propagation Delays (for a 5 V Input Signal) LOW to HIGH... 350 ns typical HIGH to LOW... 220 ns typical

Isolated Outputs Number of output channels...8 Output type...sinking (low-side switch) Output power requirement...5 VDC to 48 VDC (10 ma per channel, typical at 400 KHz) Load voltage range...5 VDC to 48 VDC Switching current...100 ma per channel, maximum Inrush current...600 ma per channel, maximum Maximum output frequency...400 khz Minimum output pulse width...1 µs Typical switching times (with a 5 V, 100 Ω load) Turn on...500 ns Turn off...150 ns Output low maximum voltage (with SH100-100-S2 cable)...0.47 V at 10 ma; 0.75 V at 100 ma Output leakage current when OFF...60 µa maximum Timing I/O Number of counters...8 up/down Resolution...32 bits Maximum count...4,294,967,295 Rollover times 100 khz timebase...11.93 h 20 MHz timebase...214.74 s Baseclocks available...100 khz and 20 MHz Baseclock accuracy...50 ppm (±0.005%) over temperature Maximum source frequency...20 MHz Data transfer...dma (up to 3 channels), interrupts RTSI Trigger Lines (PCI Only) Trigger lines <0..6>...7 RTSI clock...1 Minimum pulse width for trigger and clock...50 ns 2 ni.com NI 6624 Device Specifications

PXI Trigger Bus (PXI Only) Trigger lines <0..5>... 6 Star trigger... 1 Clock... 1 Safety Voltages Protection Inputs Current limit... 10 ma maximum (over operating temperature range) Reverse and overvoltage... ±60 VDC Outputs Short circuit (on output pins)... 0.6 A minimum, 1.1 A maximum (stays off after detecting a short circuit and retries to operate every 250 ms, and then automatically recovers after removing the short) Reverse and overvoltage (on output and Vdd pins)... ±60 VDC Functionality with transient spikes (on Vdd pins)... Up to 80 V peak Isolation Channel-to-channel... 60 VDC, Measurement Category I Channel-to earth ground... 60 VDC, Measurement Category I Caution Do not exceed 60 VDC between any two I/O channels. Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low voltage sources, and electronics. Caution Do not use for measurements within Categories II, III, or IV. NI 6624 Device Specifications National Instruments 3

Physical Note Measurement Categories CAT I and CAT O (Other) are equivalent. These test and measurement circuits are not intended for direct connection to the MAINS building installations of Measurement Categories CAT II, CAT III, or CAT IV. Dimensions PCI...17.5 cm 10.7 cm (6.9 in. 4.2 in.) PXI...16.0 cm 10.0 cm (6.3 in. 3.9 in.) I/O connector...100-pin female, SCSI-II type Environment NI 6624 devices are intended for indoor use only. Maximum altitude...2,000 meters (at 25 C ambient temperature) Pollution Degree...2 Operating Environment Ambient temperature range...0 C to 55 C (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2.) Relative humidity range...10% to 90%, noncondensing (Tested in accordance with IEC 60068-2-56.) Storage Environment Ambient temperature range...-20 C to 70 C (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2.) Relative humidity range...5% to 95%, noncondensing (Tested in accordance with IEC 60068-2-56.) 4 ni.com NI 6624 Device Specifications

Shock and Vibration (PXI Only) Operational shock... 30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC 60068-2-27. Test profile developed in accordance with MIL-PRF-28800F.) Random vibration Operating... 5 Hz to 500 Hz, 0.3 grms Nonoperating... 5 Hz to 500 Hz, 2.4 grms (Tested in accordance with IEC 60068-2-64. Nonoperating test profile exceeds the requirements of MIL-PRF-28800F, Class 3.) Safety Note Clean the device with a soft, non-metallic brush. Make sure that the device is completely dry and free from contaminants before returning it to service. This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1, CSA 61010-1 Note For UL and other safety certifications, refer to the product label, or visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. Electromagnetic Compatibility This product is designed to meet the requirements of the following standards of EMC for electrical equipment for measurement, control, and laboratory use: EN 61326 EMC requirements; Minimum Immunity EN 55011 Emissions; Group 1, Class A CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A Note For EMC compliance, operate this device with shielded cabling. NI 6624 Device Specifications National Instruments 5

CE Compliance This product meets the essential requirements of applicable European Directives, as amended for CE marking, as follows: 73/23/EEC; Low-Voltage Directive (safety) 89/336/EEC; Electromagnetic Compatibility Directive (EMC) Note Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the Minimize Our Environmental Impact web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document. Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of the product life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers, National Instruments WEEE initiatives, and compliance with WEEE Directive 2002/96/EC on Waste and Electronic Equipment, visit ni.com/environment/ weee. RoHS National Instruments (RoHS) National Instruments RoHS ni.com/ environment/rohs_china (For information about China RoHS compliance, go to ni.com/environment/rohs_china.) 6 ni.com NI 6624 Device Specifications

Figure 1. NI 6624 Pin Assignments PFI 39 +/CTR 0 SOURCE + PFI 39 /CTR 0 SOURCE PFI 38 +/CTR 0 GATE + PFI 38 /CTR 0 GATE PFI 37 +/CTR 0 AUX+ PFI 37 /CTR 0 AUX PFI 36 Vdd/CTR 0 Vdd PFI 36/CTR 0 Vss PFI 36/CTR 0 OUT PFI 36/CTR 0 Vss PFI 35 +/CTR 1 SOURCE + PFI 35 /CTR 1 SOURCE PFI 34 +/CTR 1 GATE + PFI 34 /CTR 1 GATE PFI 33 +/CTR 1 AUX + PFI 33 /CTR 1 AUX PFI 32 Vdd/CTR 1 Vdd PFI 32 Vss/CTR 1 Vss PFI 32/CTR 1 OUT PFI 32 Vss/CTR 1 Vss PFI 31 +/CTR 2 SOURCE + PFI 31 /CTR 2 SOURCE PFI 30 +/CTR 2 GATE + PFI 30 /CTR 2 GATE PFI 29 +/CTR 2 AUX + PFI 29 /CTR 2 AUX PFI 28 Vdd/CTR 2 Vdd PFI 28 Vss/CTR 2 Vss PFI 28/CTR 2 OUT PFI 28 Vss/CTR 2 Vss PFI 27 +/CTR 3 SOURCE + PFI 27 /CTR 3 SOURCE PFI 26 +/CTR 3 GATE + PFI 26 /CTR 3 GATE PFI 25 +/CTR 3 AUX + PFI 25 /CTR 3 AUX PFI 24 Vdd/CTR 3 Vdd PFI 24 Vss/CTR 3 Vss PFI 24/CTR 3 OUT PFI 24 Vss/CTR 3 Vss PFI 0 + PFI 0 1 51 2 52 3 53 4 54 5 55 6 56 7 57 8 58 9 59 10 60 11 61 12 62 13 63 14 64 15 65 16 66 17 67 18 68 19 69 20 70 21 71 22 72 23 73 24 74 25 75 26 76 27 77 28 78 29 79 30 80 31 81 32 82 33 83 34 84 35 85 36 86 37 87 38 88 39 89 40 90 41 91 42 92 43 93 44 94 45 95 46 96 47 97 48 98 49 99 50 100 PFI 23 +/CTR 4 SOURCE + PFI 23 /CTR 4 SOURCE PFI 22 +/CTR 4 GATE + PFI 22 /CTR 4 GATE PFI 21 +/CTR 4 AUX + PFI 21 /CTR 4 AUX PFI 20 Vdd/CTR 4 Vdd PFI 20 Vss/CTR 4 Vss PFI 20/CTR 4 OUT PFI 20 Vss/CTR 4 Vss PFI 19 +/CTR 5 SOURCE + PFI 19 /CTR 5 SOURCE PFI 18 +/CTR 5 GATE + PFI 18 /CTR 5 GATE PFI 17 +/CTR 5 AUX + PFI 17 /CTR 5 AUX PFI 16 Vdd/CTR 5 Vdd PFI 16 Vss/CTR 5 Vss PFI 16/CTR 5 OUT PFI 16 Vss/CTR 5 Vss PFI 15 +/CTR 6 SOURCE + PFI 15 /CTR 6 SOURCE PFI 14 +/CTR 6 GATE + PFI 14 /CTR 6 GATE PFI 13 +/CTR 6 AUX + PFI 13 /CTR 6 AUX PFI 12 Vdd/CTR 6 Vdd PFI 12 Vss/CTR 6 Vss PFI 12/CTR 6 OUT PFI 12 Vss/CTR 6 Vss PFI 11 +/CTR 7 SOURCE + PFI 11 /CTR 7 SOURCE PFI 10 +/CTR 7 GATE + PFI 10 /CTR 7 GATE PFI 9 +/CTR 7 AUX + PFI 9 /CTR 7 AUX PFI 8 Vdd/CTR 7 Vdd PFI 8 Vss/CTR 7 Vss PFI 8/CTR 7 OUT PFI 8 Vss/CTR 7 Vss PFI 4 + PFI 4 = No Connect NI 6624 Device Specifications National Instruments 7

Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for more information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patents Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. 2006 2016 National Instruments. All rights reserved. 372151B-01 Sep16