Techniques to reduce electromagnetic noise produced by wired electronic devices

Similar documents
Measurement and Analysis for Switchmode Power Design

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

ELEC 0017: ELECTROMAGNETIC COMPATIBILITY LABORATORY SESSIONS

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

Understanding and Optimizing Electromagnetic Compatibility in Switchmode Power Supplies

CHAPTER 6 EMI EMC MEASUREMENTS AND STANDARDS FOR TRACKED VEHICLES (MIL APPLICATION)

Test and Measurement for EMC

2620 Modular Measurement and Control System

Saturation of Active Loop Antennas

Understanding the Unintended Antenna Behavior of a Product

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

Description of Test Facility

YRS01 York Reference Source

Memo. 1 Summary. 1.1 Introduction. 1.2 Experiments. 1.3 Conclusion

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

Debugging EMI Using a Digital Oscilloscope. Dave Rishavy Product Manager - Oscilloscopes

EMC Overview. What is EMC? Why is it Important? Case Studies. Examples of calculations used in EMC. EMC Overview 1

Sunlight Supply, Inc.

Switched Mode Power Supply Measurements

STC Test Report. Date : Page 1 of 13 No. : HM161169

Ileana-Diana Nicolae ICMET CRAIOVA UNIVERSITY OF CRAIOVA MAIN BUILDING FACULTY OF ELECTROTECHNICS

Output Filtering & Electromagnetic Noise Reduction

Advanced Compliance Solutions, Inc FAU Blvd, Suite 310 Boca Raton, Florida (561)

Electromagnetic Compatibility

Chapter 12 Digital Circuit Radiation. Electromagnetic Compatibility Engineering. by Henry W. Ott

T + T /13/$ IEEE 236. the inverter s input impedances on the attenuation of a firstorder

Introduction to Electromagnetic Compatibility

HAMEG EMI measurement tools

EMC and Variable Speed Drives

Radiated emission is one of the most important part of. Research on the Effectiveness of Absorbing Clamp Measurement Method.

Testing for EMC Compliance: Approaches and Techniques October 12, 2006

The water-bed and the leaky bucket

7. Transmitter Radiated Spurious Emissions and Conducted Spurious Emission

Course Introduction. Content 16 pages. Learning Time 30 minutes

KENNETH WYATT Senior EMC Engineer Wyatt Technical Services. One tool every EMC INTRODUCTION

EMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter

Performance Evaluations and Comparative Electromagnetic Compatibility Measurements on Compact Fluorescent Lamps

The Impact Of Signal Jumping Across Multiple Different Reference Planes On Electromagnetic Compatibility

A Study of Conducted-Emission Stable Source Applied to the EMC US and EU Standards

MAKING TRANSIENT ANTENNA MEASUREMENTS

Stand Alone RF Power Capabilities Of The DEIC420 MOSFET Driver IC at 3.6, 7, 10, and 14 MHZ.

The Causes and Impact of EMI in Power Systems; Part 1. Chris Swartz

TECHNICAL REPORT: CVEL EMI Source Modeling of the John Deere CA6 Motor Driver. C. Zhu, A. McDowell and T. Hubing Clemson University

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

LTE Band 7. Channel

Relationship Between Signal Integrity and EMC

EMC Pulse Measurements

Influence of interface cables termination impedance on radiated emission measurement

AUR.EL RTX-MID-868-OOK DESCRIPTION. MECHANICAL DIMENSIONS and PIN-OUT. Absolute maximum values

LISN UP Application Note

Development of a noval Switched Beam Antenna for Communications

Guide on Implementation of Requirements of the Common EPS

TEST REPORT... 1 CONTENT...

VLSI is scaling faster than number of interface pins

Verifying Simulation Results with Measurements. Scott Piper General Motors

High Efficiency Classes of RF Amplifiers

Application Note AN- 1094

Automotive EMC. IEEE EMC Society Melbourne Chapter October 13, 2010 By Mark Steffka IEEE EMCS Distinguished Lecturer

A NEW COMMON-MODE VOLTAGE PROBE FOR PREDICTING EMI FROM UNSHIELDED DIFFERENTIAL-PAIR CABLES

Automotive Systems Past and Present

Measurement of RF Emissions from a Caterpillar Inc. MSS3s RF ID Key Fob

Probe Considerations for Low Voltage Measurements such as Ripple

Certificate of Test AND KEEPS ALL REQUIREMENTS ACCORDING THE FOLLOWING REGULATIONS IEC :2001 IEC :2007

WirelessUSB LS Radio Module FCC Testing & Verification - AN4006

A VIEW OF ELECTROMAGNETIC LIFE ABOVE 100 MHz

Transient calibration of electric field sensors

EMC standards. Presented by: Karim Loukil & Kaïs Siala

Radiated Spurious Emission Testing. Jari Vikstedt

4. THEORETICAL: EMISSION AND SUSCEPTIBILITY. pressure sensor, i.e, via printed-circuit board tracks, internal wiring which acts as an

ECHOSTAR 54.0 BRISBANE VOICE REMOTE 2017 MODEL: URC-2027BC0-R

Radio compliance test

BIRD 74 - recap. April 7, Minor revisions Jan. 22, 2009

An Introduction to EMC Testing (what can be done with scopes) Vincent Lascoste EMC Product Manager - RSF

Comparison of IC Conducted Emission Measurement Methods

Engineering the Power Delivery Network

Considerations about Radiated Emission Tests in Anechoic Chambers that do not fulfil the NSA Requirements

AC Wire Carrier Current Devices (Unintentional Radiators)

FCC Test Report. : ASE Group 4F,No 133, Sec 4, Mingsheng E Rd, Songshan Dist, Taipei, Taiwan

Conducted EMI Simulation of Switched Mode Power Supply

Signal and Noise Measurement Techniques Using Magnetic Field Probes

Chapter 5 Electromagnetic interference in flash lamp pumped laser systems

Compliance Engineering Ireland Ltd

The Measurement and Uncertainty Analysis of Antenna Factor of Microwave Antennas Based on Standard Site Method

ELEC Course Objectives/Proficiencies

Chapter 16 PCB Layout and Stackup

Overview of the ATLAS Electromagnetic Compatibility Policy

L.S. Compliance, Inc. W66 N220 Commerce Court Cedarburg, WI

TABLE OF CONTENTS APPLICANT: FLYING DRAGON DEVELOPMENT LTD. FCC ID: PNX-FD383-SV-01 TEST REPORT CONTAINING:

EMC Test report for LED Panel Light Models , , , , ,

Sources of transient electromagnetic disturbance in medium voltage switchgear

Practical Considerations for Radiated Immunities Measurement using ETS-Lindgren EMC Probes

Electromagnetic field distribution within a semi anechoic chamber

EET 223 RF COMMUNICATIONS LABORATORY EXPERIMENTS

10 Safety earthing/grounding does not help EMC at RF

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.

DC/DC-Converters in Parallel Operation with Digital Load Distribution Control

Ave output power ANT 1(dBm) Ave output power ANT 2 (dbm)

USER. manual. Falco Systems WMA-100. High Voltage Amplifier DC - 500kHz

Investigation of Electromagnetic Field Coupling from DC-DC Buck Converters to Automobile AM/FM Antennas

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

Transcription:

Rok / Year: Svazek / Volume: Číslo / Number: Jazyk / Language 2016 18 5 EN Techniques to reduce electromagnetic noise produced by wired electronic devices - Tomáš Chvátal xchvat02@stud.feec.vutbr.cz Faculty of Electrical Engineering and Communication, Brno University of Technology DOI: - Abstract: The article describes possible ways and techniques for reducing the electromagnetic interference that is produced by electronic devices. Electromagnetic interference is handled by national and international authorities. The authorities define individual limits of mentioned electromagnetic interference within specific frequency bandwidth. Provided information can help engineers to identify root cause of product noncompliance in the field of electromagnetic interference. Experimental measurements supports provided theory about cable assemblies interaction with the unintentional generator output quantities occupying frequency spectrum.

Techniques to reduce electromagnetic noise produced by wired electronic devices Tomáš Chvátal Faculty of Electrical Engineering and Communication, Brno University of Technology Email: xchvat02@stud.feec.vutbr.cz Abstract The article describes possible ways and techniques for reducing the electromagnetic interference that is produced by electronic devices. Electromagnetic interference is handled by national and international authorities. The authorities define individual limits of mentioned electromagnetic interference within specific frequency bandwidth. Provided information can help engineers to identify root cause of product noncompliance in the field of electromagnetic interference. Experimental measurements supports provided theory about cable assemblies interaction with the unintentional generator output quantities occupying frequency spectrum. 1 Introduction Many of techniques are available to make electronic device compliant with the limits provided by international standards for radiated emissions. One of the validation techniques is radiated interference verification in semi-anechoic chambers. Equipped semi-anechoic chamber can provide complete overview of electronic product radiated emissions. It is a time consuming process that is looking for highest value of radiated electric field. For this reason the electric field is measured from every device side. Turn table secures automatic device rotation. Electronic device is also wanted to be compliant in each operational state it can operate. Transition behaviors and intermittent operational states can be typically excluded from such a compliance measurement. Measurement of radiated emissions per standards recommendations is not a suitable method in case of flexible electronic product development. Any individual change in product design needs to be verified. Every manufacturer is aware of possibility to see design behavior immediately after the change is made. Slight modification in product hardware or firmware can bring important results that help to find a solution. Any fast indirect comparison method then supports dynamic product development. Key information is hidden in reality of tens of kilohertz oscillator as a source of electric field exceeding significantly standard limits at frequency of hundreds of megahertz. The experimental measurements are conducted just with single wire antenna. wire length, wire cable assembly and device wiring versus semi-anechoic chamber surrounding. 2.1 Unintentional monopole antennas Fig. 1 shows possible device unintentional antennas. Those two effective antennas can be found in a common electronic system. Unintentional antennas are also located inside the electronic product especially as layers on printed wiring board. The same rules of electromagnetic waves propagation as for cable assemblies are expected. From the physical point of view the product common mode emissions make the monopole antennas radiating. Setup for typical radiated interference measurement consists of a potential dipole antenna. The first half of dipole antenna is made by product cable, wire or wire harnesses and its second half is presented by ground plane of semi-anechoic chamber. Dipole resonant frequency is based on dipole physical length l = λ/2. Unintentional product monopole antenna is then created by length of l = λ/4. Unless otherwise stated the product manufacturer is forced by standard to verify product emissions with 1 m cable length. Product cables are usually lead in horizontal polarization against the semi-anechoic chamber ground floor. Power cable is usually vertically polarized and directly plugged into the socket. The rest of cables length is used for product interconnections. Directivity of a quarter wave monopole above a ground plane is equal to twice that of a half-wave dipole radiating in free space [1]. The maximum directivity occurs along the ground plane and the radiation is vertically polarized. Ideal monopole resonant frequency can be easily calculated by expression (1). λ, (1) where λ = 4l and l is monopole length, f is the resonant frequency, c is velocity of the light. Example 1: Obviously the most critical frequency that collocates with expression (1) is approximately f = 100 MHz. 2 Wires as effective unwanted antennas Every piece of wire that leads outside the electronic device is a potential antenna. Usually cables of various lengths lead into the product terminals from various directions. These unwanted antennas and its tunability during the electromagnetic interference measurement is typically depending on wire diameter, Figure 1: Example of unwanted monopole & loop antennas. 137

Parasitic inductances created by printed wiring board layers are visible in Fig. 1. Inductance voltage can be calculated by (2)., (2) where v is voltage, i is current, L is inductance and t is time. Example 2: In case we will use for (2) real values, L = 10 nh, t = 10 ns, i = 1 A, we obtain v = 1 V of source voltage for monopole antenna. are 32 khz and 4 MHz. These oscillators were separately connected to 5 V TTL. Two kind of TTL were exposed to electromagnetic field interference measurement. The LS type with 9 ns rising/falling edge and HCT with 3 ns rising/falling edge. The HCT also showed ringing effect. Single wire antenna of 0.75 m length and 0.7 mm diameter was connected directly to TTL output. Example 3: Frequency count per Fig. 2 for HCT with t r = 3 ns, 1/πτ r = 106 MHz. 3 Frequency response of unwanted generators Most of the electronic products are using digital signals for driving its auxiliary circuitries. These digital signals are being deformed along the path from microprocessor to the product output gates. The digital signal deformations depend on circuitry components non-linearity. Transistors, bus drivers and other active components are amplifying devices of microprocessor signal rising/falling edges. Different u/ t and i/ t responses are possible source of disturbance in frequency domain. Fast current and voltage responses on digital signal falling/rising edge are also factors that increase harmonics magnitude of circuitry fundamental frequency. Those harmonics are propagated in to the free space by product wiring, supply lines and communication interfaces as described in 2.1. 3.1 Magnitude spectrum of rising, falling edge and effect of ringing. The magnitude of specific digital signal harmonics in frequency spectrum is related to signal rising/falling edges, fundamental frequency duty cycle and waveform amplitude. Relation between time domain and frequency domain of trapezoidal pulse is illustrated in Fig. 2. This is based only on simplifying presumption that rising/falling edges duration is equal. Oscillating behavior can occur when rising edge achieves its maximum or falling edge its minimum. This oscillating behavior also known as ringing amplifies harmonics magnitude of circuitry fundamental clock frequency. Such ringing is then visible as harmonics magnitude increase at frequencies corresponding to ringing waveform. Figure 2: One-sided magnitude spectrum of a trapezoidal pulse train [2] 4 Experimental measurements Based on example 1 and example 2 the simple transmitter was made. The transmitter was prepared for change of its fundamental frequency. Chosen oscillator frequencies in our case Figure 3: Experimental Transmitter Spectrum of transmitter output signal was measured by oscilloscope with spectrum analyzer option. Oscilloscope active probe loaded the transmitter output by 1 MΩ impedance and 0.8 pf parasitic capacitance. Oscilloscope analyzer resolution bandwidth was set to 120 khz which is compatible with resolution bandwidth of semi-anechoic chamber receiver. Shapes of magnitudes at particular frequencies can be comparable in this case. Final measurements were conducted in fully anechoic chamber from 3 m measurement distance. In fully anechoic chamber the wire antenna polarization is not influenced by electromagnetic waves reflection from the chamber ground plane. Receiver filter was set on 120 khz [4] resolution bandwidth in accordance with radiated emissions standard. Single wired antenna was connected to our experimental transmitter output and polarized horizontally versus test system receiving antenna. The transmitter was supplied by 3 pieces of 1.5 V AA type batteries. Spectral data was measured by EMI receiver with FFT option therefore every measurement took few seconds and transmitter power consumption did not influence measured data at all. For that reason battery discharge did not need to be considered. 4.1 Transmitter output spectra Figure 4, Figure 5 and Figure 6 show various output spectra of generator output. Table 1 voltage compares magnitudes at frequency 110 MHz. It is a frequency where the antenna resonance was expected and measured. Table 1: Approximate voltage magnitudes at frequency of interest of 110MHz. 32 khz HCT ~55 dbuv 32 khz LS 4 MHz HCT ~40 dbuv ~95 dbuv 138

single wire antenna resonance occurred. Electric field magnitudes at single wired antenna resonance frequencies visible in those two figures are dependent on generator rising/falling edges duration. However antenna specific resonant frequency determined from Fig. 7, 8, 10, 11 stays unchanged. Figure 4: Output spectrum of HCT connected to 32 khz oscillator. Figure 7: Radiated interference of 32 khz transmitter with LS. Single wire antenna of 0.75 m length was connected to transmitter output. Figure 5: Output spectrum of LS connected to 32 khz oscillator. Figure 8: Radiated interference of 32 khz transmitter with HCT. Single wire antenna of 0.75 m length was connected to transmitter output. Figure 6: Output spectrum of HCT connected to 4 MHz oscillator. 4.2 Radiated emissions measurement comparison A limit of 40 dbuv/m [3] is specified by standard in frequency range from 30 MHz to 230 MHz for general purpose household appliances at 3 m measurement distance. It is important to note that 5 V source operating at 32 khz fundamental frequency can make a device noncompliant. In Fig. 7 and Fig. 8 Figure 9: Radiated interference of 32 khz transmitter with HCT. Single wire antenna of 0.75 m length was connected to transmitter output. Transmitter was grounded to chamber chassis. 139

Fig. 9, 12 show changes of resonant frequency while the transmitter is grounded on chamber chassis. Grounding wire of 1 m length made the previous monopole antenna longer and it now resonates with lower frequency. Antenna radiates also in vertical polarization at lower frequency. It is because the transmitter grounding wire is first half of a vertically polarized dipole whereas horizontally polarized wire connected on transmitter output is the second part of dipole antenna. because EMI filter resolution bandwidth is four time wider and measured harmonics are overlapped and creating the envelope. Figure 12: Radiated emissions of 4 MHz transmitter with HCT. Single wire antenna of 0.75 m length connected to transmitter output. Transmitter was grounded to chamber chassis. Figure 10: Radiated interference of 32 khz transmitter with HCT. Antenna of a 0.75 m length connected to transmitter output. Instead of single wire ribbon cable was used. Ribbon second wire was connected to transmitter ground. Antenna resonant frequency stays unchanged while using a two wires ribbon cable. One of the ribbon cable wire is connected directly to transmitter output whereas the other from ribbon cable wire is connected to generator ground. See Fig. 10 for waveform. Figure 13: Radiated emissions of 32 khz transmitter with HCT. Single wire antenna of 0.4 m length connected to transmitter output. Fig. 13 illustrates wire antenna resonant frequency while the wire antenna length was reduced to 0.4m. Antenna resonant frequency change corresponds with wire length again. Table 2: Approximate magnitudes of electric field at frequency of interest during emissions measurement of nongrounded transmitter. Figure 11: Radiated emissions of 4 MHz transmitter with HCT. Single wire antenna of 0.75 m length connected to generator output. Fig. 11 in comparison to Fig. 7, 8, 10, 11 shows similar shape of antenna resonant frequency waveform. Visibility of 4 MHz harmonics is caused by usage of 120 khz EMI receiver resolution bandwidth. Same receiver resolution bandwidth was applied for interference measurement of transmitter with 32 khz oscillator. 32 khz harmonics are not visible in this case 32 khz HCT ~47 dbuv/m 5 Conclusions 32 khz LS 4 MHz HCT ~40 dbuv/m ~80 dbuv/m In the article it is described general product development technique for electromagnetic interference source identifica- 140

tion. From the experimental measurements it is obvious that device cables and their specific length plays significant role in electromagnetic unintentional interference propagation into the surrounding. Its tunability is especially depending on its length. Change of EMI receiver resolution bandwidth to product lowest internal frequency can help to investigate source of interference at unintentional antennas resonance frequencies. Specific product output that works as emissions generator can be then investigated by removing each input/output cable individually. Acknowledgements I would like to thank the Honeywell company for the opportunity and technical support during the measurements. Literature [1] HARISH, A. R. and SACHIDANANDA, M. Antennas and Wave Propagation. N. Y., Oxford University Press, 2007, ISBN: 978 0 19 568666 1 [2] PAUL, C. R. Introduction to Electromagnetic Compatibility. 2nd. ed. Hoboken, N. J. John Wiley, c2006. ISBN: 978-0- 471-75500-5 [3] OTT. H. W., Electromagnetic Compatibility Engineering. Hoboken, N. J. John Wiley, c2009. ISBN: 978-0-470-18930-6 [4] CISPR 16-1-1:2015. Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus. International Electrotechnical Commission, 2015. ISBN: 978-2-8322-2922-4 141