Product Specifications

Similar documents
Product Specifications

Shaft Absolute Vibration Monitor Specifications

Speed and Key Monitor Specifications

Application Note. Monitoring strategy Diagnosing gearbox damage

VMS 830. Vibro-Meter Vibration Monitor FEATURES GENERAL. Absolute vibration measurement. Monitoring of machines and industrial plants

MTN/8066/G-MAC VIBRATION MODULE

Vibration amplifier Model 6634C

APPLICATION NOTE. Detecting Faulty Rolling Element Bearings. Faulty rolling-element bearings can be detected before breakdown.

OD / 053 / 054 / 055

VM-701B VIBRATION / DISPLACEMENT MONITOR MODULE Page 1 of 7

SP-2020/SSI Signal Simulator Interface

DIGEM f 96 x 48 EK. Applications. Description

1701/25 FieldMonitor Seismic Input Monitor for Velocity and Acceleration Input

PRODUCT DATA. 16-channel DeltaTron Conditioning Amplifiers Types 2694-A/B/C/D. Features and Uses

Application Note. Case study Integrated vibration, process monitoring at HPP Momina Klisura

Acceleration Sensor AS - 022

the 3500/44M Aeroderivitive GT Vibration Monitor for the

Applications Note. Bently Nevada* Asset Condition Monitoring. Periodically Monitored Assets. Connecting SCOUT to Continuous Monitoring Systems

NON-SELLABLE PRODUCT DATA. Order Analysis Type 7702 for PULSE, the Multi-analyzer System. Uses and Features

Wind Turbine Analysis System - Type 3652 MKII & MKIII

Introduction to Kionix KXM Tri-Axial Accelerometer

Within reach. The standard for online machine surveillance

XMV16 / XIO16T Extended vibration monitoring card pair XMV16

Q.raxx A101-8 slimline RS / EC

T40FH. Torque flange. Special features. Data sheet

Condition Monitoring Custom Products

Indeks: WMXXCMM60 Advanced Industrial Multimeter

VM-702B ABSOLUTE VIBRATION MONITOR MODULE Page 1 of 5

Q.raxx A slimline RS / EC Universal Measurement System

PRODUCT DATA. PULSE Reflex Angle Domain Analysis Type Uses and Features

The new generation More comfortable even faster more precise SmartBalancer2 Perfect field balancing made easy

VM-702B ABSOLUTE VIBRATION MONITOR MODULE Page 1 of 5

MAGTROL. LMU 112 and LMU 117 Load Monitoring Units. LMU 112 / LMU 117 Data Sheet LMU 112 FEATURES LMU 117 FEATURES DESCRIPTION SYSTEM CONFIGURATION

Rotational speed controller

control & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS

MDEX. on customized sensors. Technical information. Torque transducer. CS-T-04-MDEX Special features

Technical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity

Q.raxx A slimline RS / EC

DRTS-6. DRTS-6 has been designed to test: DRTS-6. Advanced Protection Relay Test Set and Measurement System

VM-703 TACHOMETER & ECCENTRICITY MONITOR MODULE Page 1 of 5

T40B. Torque Flange. Special features. Data sheet. Overall concept

high accuracy tester-calibrator PJ 6301

DOCUMENTATION. Its affordable price allows you to meet your budget target.

Function/Arbitrary Waveform Generator

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Keysight Technologies N9320B RF Spectrum Analyzer

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

LM231A/LM231/LM331A/LM331 Precision Voltage-to-Frequency Converters

INTER PLANT STANDARD STEEL INDUSTRY

Agilent N9320B RF Spectrum Analyzer

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Function/Arbitrary Waveform Generator

Portable Multi-Channel Recorder Model DAS240-BAT

High Performance Process & Temperature Controllers

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en

Isolation Amplifier (electrically isolated input-output) ISO 6, ISO 4 and ISO 2. Instrumentation Amplifier (low drift) IA 6, IA 4, IA 2

FEATURES. Timers Low Supply Detector. Power up Timer. Post Alarm Dead Time. Counter. Pulse Width Discriminator. Discriminator control function

Excellent low-cost Process & Temperature Controllers

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

MAGTROL. LMU 116 Load Monitoring Unit. LMU 116 Data Sheet FEATURES DESCRIPTION SYSTEM CONFIGURATION

Aero Support Ltd, 70 Weydon Hill Road, Farnham, Surrey, GU9 8NY, U.K.

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Agilent N9320B RF Spectrum Analyzer

T22. Torque transducer. Special features. Data sheet

A6500-UM Universal Measurement Card

3500/64M Dynamic Pressure Monitor

VIBROCONTROL 1100 C01 / C02 / C11 / C12. Technische Dokumentation Technical Documentation Documentation Technique C

SEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications

Fluke 83V and 87V Digital Multimeters

GEMINI PRESETTABLE DUAL RATE INDICATOR WITH RATIO (A/B)

Function Modules GL7- DISP GL7 - SSD GL7 - DCO. Datasheet. Function Modules. Voltage Output Module

Series 1700 PX. Selection Guide. Threshold relays. Process signal converters/isolators. Temperature converters

Setpoint Rolling Element Bearing Support

Thermocouple Conditioner and Setpoint Controller AD596*/AD597*

Emotron FDU 2.0 Variable Speed Drive

Function/Arbitrary Waveform Generator

CEC VIBRATION TRANSMITTER

NON-SELLABLE PRODUCT DATA

3500/40M Proximitor Monitor

Create SKF Multilog On-line System IMx Transient Groups for Run up and Coast down Data Collection in Observer

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

Model DML 100 Accuracy class 0.1 No. Nominal torque M nom (bidirectional) Nm 100 Speed range rpm 0 10,000 Output signal Unit Value

AS-1250FE Datasheet Dynamic Signal Acquisition Front-End for Rotating Machinery Monitoring and Analysis

T10F. Data Sheet. Torque Flange. Special features. Installation example T10F. B en

Copyright 2016 by Brüel & Kjær Vibro GmbH, D Darmstadt

Torque Sensor DML 500 S080S10X

CMM System - Encapsulated Modules

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

2520 Pulsed Laser Diode Test System

Variable Gain 100 MHz Wideband Voltage Amplifier

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Emotron FDU 2.0 Variable Speed Drive

MX800 BASE STATION SPECIFICATIONS

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

Low Cost 100 g Single Axis Accelerometer with Analog Output ADXL190*

ATA-2001 Analog LVDT/RVDT Signal Conditioner with digital calibration

MTL4000 SERIES. isolating IS interface units. For close integration of IS circuits into processconnected

ATA-2001 Analog LVDT/RVDT Signal Conditioner with digital calibration

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

Sefram. Sefram SEFRAM A new family of thermal recorders 6 to 36 channels. Make sure to visit our Website

Transcription:

Product Specifications VC-6000 Monitoring System Monitoring Module SM-610-A06 User-Defined: up to 11x Vibration inputs, up to 2x Axial position, up to 2x Phase Reference/Speed with 8x DC Outputs and 2x Relays The VC-6000 Monitoring System hardware is used for both stand-alone safety monitoring and condition monitoring using the Compass 6000 monitoring software modules and database. The VC-6000 offers various standard monitoring modules, power supply modules and communication modules. This Product Specification describes the SM-610-A06. Applications The SM-610 series of VC-6000 Monitoring Modules are designed to provide protective monitoring of various types of industrial machines. The SM-610- A06 is specifically designed as a user-defined monitoring module, where there are a number of selectable differential inputs and outputs. This is useful for monitoring machines with special applications, e.g. Hydro machines. General Description The features and functions common to all SM-610 Monitoring Modules are briefly listed below. Please refer to the VC-6000 Product Specification (BPS 0044) for more information. Interfacing with the CI-620 Communication Module High speed digital signal processor Relay outputs (logic controlled) DC outputs Module OK-relay status indication Extensive local LED indication Flash memory for storing settings and local logbook High speed reaction time Alarm limits with programmable hysteresis and response delay time Global trip multiply and override Extensive self-monitoring functions System bus interface to other modules Buffered input signal outputs Inputs Up to 11 x vibration input channels freely configurable with measurements 3 x binary input channels Up to 2 x axial position Up to 2 x speed inputs, with one dedicated for 1x Master 1 (central) trigger input signal 1 x Slave input channel 1 Providing trigger signals to other SM-610-xxx modules. BPS0126-EN-18 1

Measurements The measurements available depend on the inputs selected. These can include up to: 2x speed/phase reference rotation direction, zero speed, run up, coast down Bandpass up to 11x single-point and/or up to 5x dual-point pairs with user-defined ISO (up to 11x) OR user defined variable (up to 6x) HP and LP filters Limit monitoring with up to 8* different sets of Alert and Danger limits according to 8 * definable machine states Outputs * Please note: Together with Compass 6000 a maximum of 6 different machine states is definable. 2 x relays (any combination of Alert and Danger). Selectable for any AC/DC measurement alarm limits. Relay logic operators AND, OR, NOT, and ( ) can be used in a user-defined voting logic with any combination of measurement alarm limits 8 x DC outputs freely assignable to any AC/DC measurement. Input Channel Configuration Combinations No. Sum of Inputs Variable Band-pass Dual- Single- Channels/Measurements ISO Filter Axial Position Dual- Single- Speed/Phase Reference Binary- Inputs DC-out Outputs 1 9 6 - - - 3 8 2 2 10 5-1 1 3 8 2 3 11 5 2 1-3 8 2 4 11 5 1 2-3 8 2 5 11 4 1 1 2 3 8 2 6 11 4 2 1 1 3 8 2 7 11 4-2 2 3 8 2 8 12 4 4 1-3 8 2 9 12 4 3 2-3 8 2 10 12 3 5-1 3 8 2 11 12 3 4-2 3 8 2 12 13 3 4 2 1 3 8 2 13 13 3 7 - - 3 8 2 14 13 3 3 2 2 3 8 2 15 13 2 7-1 3 8 2 16 13 2 6-2 3 8 2 17 14 3 6 2-3 8 2 18 14 2 9 - - 3 8 2 19 14 2 6 2 1 3 8 2 20 14 2 5 2 2 3 8 2 21 15 2 8 2-3 8 2 22 15 0 11 1-3 8 2 23 15 0 11-1 3 8 2 24 15 1 8 1 2 3 8 2 25 15 1 8 2 1 3 8 2 26 15 1 7 2 2 3 8 2 27 15 0 10 1 1 3 8 2 28 15 0 10 2-3 8 2 29 15 0 10-2 3 8 2 Relays 1 A dual-point band-pass measurement can alternatively be set up as two single-point measurements and vice versa. Table 1: Input channel combinations BPS0126-EN-18 2

Signal Flow Diagrams User Definable Measurement Channel Inputs (maximum subject to overall input allocation). Figure 1. Speed reference sensor input (selectable in 2 channels), alternatively the Master Trigger signal of another SM-610-xxx module can be chosen. Channel 1B can be designated as a master speed/phase reference channel for distribution to other SM-610-xxx modules in up to 4 racks. The three binary input channels together with the digital status signals of the Dual Speed measurement and/or definable speed ranges are the input signals for the Machine State selection, which defines up to 8* different machine states. For each machine state a different limit set of Alert and Danger values can be set up. *Please note: Together with Compass 6000 a maximum of 6 machine states are available. The machine state coder in the 7126/7123 software shows a Compass 6000 compatibility marker! Figure 2: 11 vibration input channels can be configured as Smax, Max X/Y or single measurements (RMS, Peak, ). Up to 6 of these measurements can be configured with variable band-pass. Please have a look at table 1: Input channel combinations BPS0126-EN-18 3

Figure 3. 8 DC-output channels can be freely assigned to any AC/DC measurement within the SM-610-A06 module. Figure 4. 2 output relays can be assigned with a free assignable voting logic to any limit within the SM-610-A06 module. Defining Machine states There are various possibilities to define the different machine states for the Safety monitor module SM-610- A06. 1. Using the three binary-inputs to define over bit pattern a maximum of 8 different machine states. The input signals could be signals of the DCS system, that indicate different machine states like pumping state or generating state of the hydro machine. 2. Using the speed signals in addition to the binary inputs. Out of the speed signal various logic signals can be detected, like zero speed, run-up, coast down or rotation direction. 3. Machine states can also be defined by different speed ranges. Please note: The configuration software allows setting Compass 6000 compatibility mode. Then only a maximum of 6 different machine states are possible! BPS0126-EN-18 4

Technical Specifications The specifications given below are specific for the SM-610-A06 Monitoring Module. See the VC-6000 Product Specifications for features and functions common to all SM-610 Monitoring modules. AC/DC Vibration Sensor Inputs Input voltage range... 21.5V to 1V Input frequency range: Accelerometer/velocity sensor... 1Hz to 20kHz Displacement sensor... DC to 20kHz Input impedance: Accelerometer... >800kΩ Velocity sensor... 50kΩ Displacement sensor... >800kΩ Gain: Accelerometer sensor: No integration... 1 to 80 Analogue integration... 1 to 80 Velocity sensor... 1 to 80 Displacement 1 sensor... 1 Sensitivity: Accelerometer... adjustable (e.g. 100mV/g) Velocity sensor... adjustable (e.g. 100mV/mm/s) Displacement sensor... adjustable (e.g. 8mV/µm) Common mode rejection: DC to 30kHz... typically 90dB 30kHz to 100kHz... typically 85dB Maximum accelerometer input signal (100mV/g): No integration... 1.25g to 80g peak Analogue integration... 12.5mm/s to 150mm/s peak Sensor power: Sensor supply... 24VDC ±2% Maximum current... 30mA Speed/Phase Reference Sensor Inputs Input voltage range... 21.5V to 1V Input frequency range... DC to 20kHz Input impedance... >800kΩ Gain... 1 Common mode rejection: DC to 10kHz... typically 90dB 10kHz to 100kHz... typically 85dB Sensor power: Sensor supply... 24VDC ±2% Maximum current... 30mA Binary Inputs Input impedance... 3.3kΩ Accuracy... response time 5ms Minimum current load... 5mA Maximum contact voltage... ±50V Signal status LOW: Nominal input voltage... 0V Input voltage range... 50V to 6.6V Maximum input current... 2mA Signal status HIGH: Nominal input voltage... 24V Input voltage range... 16.5V to 50V Maximum input current... 5mA Buffered Outputs Minimum output load... 100kΩ Output gain... 1 (±2%) Cross-talk... typically 90dB (up to 50kHz) Inherent noise (1Hz to 50kHz)... typically 10mV RMS Output impedance... <100Ω Frequency range... DC to 50kHz (phase shift <5%) Output offset... ±13mV Analogue DC Outputs Current output: Current range... 0mA to 20mA or 4mA to 20mA Maximum output load...500ω Accuracy... max. deviation 2.4% of measured value Offset... <20µA Voltage output: Voltage range... 0V to 10V or 2V to 10V Minimum output load... 1kΩ Accuracy... max. deviation 1.3% of measured value Offset... <9.5mV Relay Outputs Nominal working voltage... 24V Maximum current... 100mA BPS0126-EN-18 5

Measurements Meas. Name Frequency Range Measuring Time Detection Alarm Limits Measuring Range Units 1 Accuracy (25 C, 80Hz, 0-Peak) Bandpass (ISO 10816) HP: 1Hz to 10Hz LP: 1kHz 80g g ±(0.08g + 0.75% of measured value) 150mm/s 2 mm/s ±(0.6mm/s + 2.75% of measured value) 100mm/s mm/s ±(0.1mm/s + 0.75% of measured value) Bandpass (ISO 7919) HP: 1Hz to 10Hz LP: 1kHz S max HP: 1Hz to 16kHz LP: 1.25Hz to 20kHz Peak X-Y max HP: 1Hz to 16kHz LP: 1.25Hz to 20kHz 80g g ±(0.08g + 0.75% of measured value) 150mm/s 2 mm/s ±(0.6mm/s + 2.75% of measured value) 100mm/s mm/s ±(0.1mm/s + 0.75% of measured value) Variable bandpass HP: 1Hz to 16kHz LP: 1.25Hz to 20kHz 80g g ±(0.08g + 0.75% of measured value) 150mm/s 2 mm/s ±(0.6mm/s + 2.75% of measured value) 100mm/s mm/s ±(0.1mm/s + 0.75% of measured value) DC (axial) - 10ms to 100s - 2x Alert, 2x Danger DC - - - - 22.0 V V ±(16.0mV + 1.0% of measured value) (gap voltage) 3 Signal slope: +/- Trigger level (manual or automatic): -1.0V to 21.5V; adjustable in steps of 0.1V Hysteresis: 0 to 25V; adjustable in steps of 0.1V 10ms to 100s 0.06 to > 1500000 multiplier and divider adjustable from 1 to 99999 Speed >10000rpm: ±0.01% of measured value Speed 100 to10000 rpm: ±1 rpm Speed < 100 rpm: ±0.1 rpm (one pulse per revolution) 1 Metric and imperial units can be used; Metric units are shown only as an example. 2 One analogue integration is possible. An additional integration can be done with ISO filter settings, but this will result in loss of accuracy. 3 Only available for displacement sensor measurements e.g. vibration displacement, axial etc. Please note: For Condition Monitoring all kinds of adapted measurement are possible. BPS0126-EN-18 6

Brüel & Kjær Vibro reserves the right to change specifications without notice Brüel & Kjær Vibro A/S Brüel & Kjær Vibro GmbH 2850 Nærum Denmark 64293 Darmstadt Germany Tel.: +45 7741 2500 Tel.: +49 (0) 6151 428 1100 Fax: +45 4580 2937 BPS0126-EN-18 Fax: +49 (0) 6151 428 1200 7 E-mail: info@bkvibro.com E-mail: info@bkvibro.de www.bkvibro.com BPS0126-EN-18