NOVEL SPACE VECTOR BASED GENERALIZED DISCONTINUOUS PWM ALGORITHM FOR INDUCTION MOTOR DRIVES

Similar documents
Generalized PWM algorithm for Direct Torque Controlled Induction Motor Drives using the only Sampled Voltages

IMPLEMENTATION OF dspace CONTROLLED DPWM BASED INDUCTION MOTOR DRIVE

Z-SOURCE INVERTER WITH A NEW SPACE VECTOR PWM ALGORITHM FOR HIGH VOLTAGE GAIN

Space Vector Based Hybrid Random PWM Algorithm for DTC-IM Drive To Achieve Superior Waveform Quality

Decoupled Centric and Non-Centric PWM Techniques for Open-End Winding Induction Motor Drive

Switching Loss Characteristics of Sequences Involving Active State Division in Space Vector Based PWM

Decoupled Space Vector PWM for Dual inverter fed Open End winding Induction motor drive

Adaptive Neural Fuzzy Inference Systems Controller for Hybrid PWM based vector controlled Induction motor drives

Analysis of Advanced PWM Algorithms Based on Simplified Sequence for Reduced CMV in Induction Motor Drive

Performance Analysis of Space Vector Modulation

Simulation And Comparison Of Space Vector Pulse Width Modulation For Three Phase Voltage Source Inverter

A NOVEL APPROACH TOWARDS SIX-STEP OPERATION IN OVERMODULATION REGION IN SVPWM VSI

The Amalgamation Performance Analysis of the LCI and VSI Fed Induction Motor Drive

SPACE VECTOR BASED VARIABLE DELAY RANDOM PWM ALGORITHM FOR DIRECT TORQUE CONTROL OF INDUCTION MOTOR DRIVE FOR HARMONIC REDUCTION

Performance Analysis of SPWM and SVPWM Based Three Phase Voltage source Inverter. K. Latha Shenoy* Dr. C.Gurudas Nayak** Dr. Rajashekar P.

Comparison of Three SVPWM Strategies

COMPARATIVE STUDY ON CARRIER OVERLAPPING PWM STRATEGIES FOR THREE PHASE FIVE LEVEL DIODE CLAMPED AND CASCADED INVERTERS

VOLTAGE source inverter fed induction motors are widely

Modeling and Simulation of Matrix Converter Using Space Vector PWM Technique

Space Vector (PWM) Digital Control and Sine (PWM) Pulse Width Modulation modelling, simulations Techniques & Analysis by MATLAB and PSIM (Powersys)

SCIENCE & TECHNOLOGY

Hybrid 5-level inverter fed induction motor drive

International Journal of Emerging Researches in Engineering Science and Technology, Volume 1, Issue 2, December 14

Performance Analysis of Matrix Converter Fed Induction Motor with Different Switching Algorithms

Speed Control of Induction Motor using Space Vector Modulation

Three Level Three Phase Cascade Dual-Buck Inverter With Unified Pulsewidth Modulation

NPTEL

Effective Algorithm for Reducing DC Link Neutral Point Voltage and Total Harmonic Distortion for Five Level Inverter

Performance Analysis of modulation techniques for Induction motor fed by Diode-Clamped NPC Inverter

SVPWM Based Two Level VSI for Micro Grids

Simulation of Space Vector Modulation in PSIM

PERFORMANCE EVALUATION OF MULTILEVEL INVERTER BASED ON TOTAL HARMONIC DISTORTION (THD)

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

SPACE VECTOR BASED DECOUPLED PWM TECHNIQUES FOR OPEN END WINDING INDUCTION MOTOR DRIVE

Analysis of Voltage Source Inverters using Space Vector PWM for Induction Motor Drive

Speed Control of Induction Motor using Multilevel Inverter

Enhanced Performance of Multilevel Inverter Fed Induction Motor Drive

Design of High-speed Induction Motor Controllers using Space vector Pulse Width Modulation

Three Level Modified SVPWM Inverter Fed DTC Induction Motor Drive

Analytical method to calculate the DC link current stress in voltage source converters

A Novel Four Switch Three Phase Inverter Controlled by Different Modulation Techniques A Comparison

Simulation of Speed Control of Induction Motor with DTC Scheme Patel Divyaben Lalitbhai 1 Prof. C. A. Patel 2 Mr. B. R. Nanecha 3

MODELLING AND SIMULATION OF DIODE CLAMP MULTILEVEL INVERTER FED THREE PHASE INDUCTION MOTOR FOR CMV ANALYSIS USING FILTER

THREE-PHASE voltage-source pulsewidth modulation

VOLTAGE-SOURCE inverters (VSI s) are utilized in ac

Modified Multilevel Inverter Topology for Driving a Single Phase Induction Motor

Performance Study of Multiphase Multilevel Inverter Rajshree Bansod*, Prof. S. C. Rangari**

5-Level Parallel Current Source Inverter for High Power Application with DC Current Balance Control

Compensation for Inverter Nonlinearity Using Trapezoidal Voltage

CHAPTER 4 CONTROL ALGORITHM FOR PROPOSED H-BRIDGE MULTILEVEL INVERTER

A Series-Connected Multilevel Inverter Topology for Squirrel-Cage Induction Motor Drive

Symmetrical Multilevel Inverter with Reduced Number of switches With Level Doubling Network

A New Multilevel Inverter Topology with Reduced Number of Power Switches

Control of Induction Motor Fed with Inverter Using Direct Torque Control - Space Vector Modulation Technique

HARMONIC ORIENTATION OF PULSE WIDTH MODULATION TECHNIQUE IN MULTILEVEL INVERTERS

Modeling and Analysis of Multi-Phase Inverter Fed Induction Motor Drive with Different Phase Numbers

GENERALIZED PWM TECHNIQUE FOR DUAL INVERTER FED INDUCTION MOTOR DRIVE

Modeling and Simulation of Induction Motor Drive with Space Vector Control

An Induction Motor Control by Space Vector PWM Technique

Sampled Reference Frame Algorithm Based on Space Vector Pulse Width Modulation for Five Level Cascaded H-Bridge Inverter

Design of SVPWM Based Inverter for Mitigation of Harmonics in Power System

Simulation & Implementation Of Three Phase Induction Motor On Single Phase By Using PWM Techniques

Low Order Harmonic Reduction of Three Phase Multilevel Inverter

DTC SVPWM: Advanced Techniques for Reduced Common Mode Voltage

International Journal of Advance Engineering and Research Development

A New Control Method for Balancing of DC-Link Voltage and Elimination of Common Mode Voltage in Multi-level Inverters

Low Switching Frequency Pulse Width Modulation For Induction Motor Drives

Performance Analysis of Modified Z- Source Inverter for Renewable Energy System Using Modified Space Vector Pulse Width Modulation

CHAPTER 2 CONTROL TECHNIQUES FOR MULTILEVEL VOLTAGE SOURCE INVERTERS

REDUCTION OF COMMON-MODE VOLTAGE IN OPEN END WINDING INDUCTION MOTOR DRIVE USING CARRIER PHASE-SHIFT STRATEGY

Module 5. DC to AC Converters. Version 2 EE IIT, Kharagpur 1

COMPARISON STUDY OF THREE PHASE CASCADED H-BRIDGE MULTI LEVEL INVERTER BY USING DTC INDUCTION MOTOR DRIVES

Five Level Output Generation for Hybrid Neutral Point Clamped Inverter using Sampled Amplitude Space Vector PWM

Elimination of Harmonics using Modified Space Vector Pulse Width Modulation Algorithm in an Eleven-level Cascaded H- bridge Inverter

Hybrid PWM switching scheme for a three level neutral point clamped inverter

REDUCTION OF COMMON MODE VOLTAGE IN THREE PHASE GRID CONNECTED CONVERTERS THROUGH NOVEL PWM TECHNIQUES

Size Selection Of Energy Storing Elements For A Cascade Multilevel Inverter STATCOM

Space Vector PWM and Model Predictive Control for Voltage Source Inverter Control

ON-LINE NONLINEARITY COMPENSATION TECHNIQUE FOR PWM INVERTER DRIVES

Australian Journal of Basic and Applied Sciences. Simulation and Analysis of Closed loop Control of Multilevel Inverter fed AC Drives

Boost-VSI Based on Space Vector Pulse Width Amplitude Modulation Technique Punith Kumar M R 1 Sudharani Potturi 2

SPECIFIC HARMONIC ELIMINATION SCHEME FOR NINELEVEL CASCADED H- BRIDGE INVERTER FED THREE PHASE INDUCTION MOTOR DRIVE

Performance Analysis of Three-Phase Four-Leg Voltage Source Converter

SPACE VECTOR PULSE WIDTH MODULATION SCHEME FOR INTERFACING POWER TO THE GRID THROUGH RENEWABLE ENERGY SOURCES

ISSN: [Yadav* et al., 6(5): May, 2017] Impact Factor: 4.116

REDUCTION OF ZERO SEQUENCE VOLTAGE USING MULTILEVEL INVERTER FED OPEN-END WINDING INDUCTION MOTOR DRIVE

A Survey on a Unified Space Vector Pulse WidthModulation for Dual Two-Level Inverter System with Open End Winding AC Machine

Resonant Controller to Minimize THD for PWM Inverter

SIMPLIFIED SVPWM ALGORITHM BASED DIODE CLAMPED 3-LEVEL INVERTER FED DTC-IM DRIVE

Analysis of Asymmetrical Cascaded 7 Level and 9 Level Multilevel Inverter Design for Asynchronous Motor

Simulation with Experimental Measurement of Voltage Total Harmonic Distortion and Harmonic Frequency in Three-Phase Induction Motor fed from Inverter

Hysteresis Controller and Delta Modulator- Two Viable Schemes for Current Controlled Voltage Source Inverter

Multilevel Current Source Inverter Based on Inductor Cell Topology

Comparative Evaluation of Three Phase Three Level Neutral Point Clamped Z-Source Inverters using Advanced PWM Control Strategies

The Selective Harmonic Elimination Technique for Harmonic Reduction of Multilevel Inverter Using PSO Algorithm

Compare Stability Management in Power System Using 48- Pulse Inverter, D-STATCOM and Space Vector Modulation Based STATCOM

Pulse Width Modulator for Voltage Regulation in Voltage Source Inverter

Analysis of IM Fed by Multi-Carrier SPWM and Low Switching Frequency Mixed CMLI

Buck-Boost Converter based Voltage Source Inverter using Space Vector Pulse Width Amplitude modulation Jeetesh Gupta 1 K.P.Singh 2

Simulation of Dc-Link Power Converter for Integrating Offshore Wind Turbine Generator to Grid

Transcription:

NOVEL SPACE VECTOR BASED GENERALIZED DISCONTINUOUS PWM ALGORITHM FOR INDUCTION MOTOR DRIVES K. Sri Gowri 1, T. Brahmananda Reddy 2 and Ch. Sai Babu 3 1 Department of Electrical and Electronics Engineering, R.G.M.C.E.T, Nandyal, A. P., India 2 Department of Electrical and Electronics Engineering, G. Pulla Reddy Engineering College, Kurnool, A. P., India 3 Department of Electrical Engineering, J. N. T. University, Anantapur, A. P., India E-Mail: gowrivasu.3@gmail.com ABSTRACT This paper presents a novel space-vector based Generalized Discontinuous pulse width modulation (GDPWM) algorithm without angle estimation based on the concept of imaginary switching times. The conventional space vector pulse width modulation (CSVPWM) method with equal division of zero state vectors V 0 and V 7 is modified. A constantvariable µ and modulation phase angle δ ranging from 0 to 1 are used to generate infinite number of modulating waveforms. Also, the classical triangle comparison approach is replaced by space vector approach. To avoid the complex coordinate transformations, trigonometric calculations and sector identification involved in CSVPWM, the concept of imaginary switching times is utilized. The imaginary switching times proportional to the reference phase voltages are used to calculate the actual switching times for reduced complexity and memory required. The proposed PWM technique results in reduced current ripple over the CSVPWM at high modulation indices and low switching losses at all modulation indices. To validate the proposed method, simulation is carried out on V/f controlled induction motor and the no-load current waveforms at different modulation indices and frequencies are presented and %THDs is compared. Keywords: CSVPWM, GDPWM, imaginary switching times. INTRODUCTION Any PWM strategy for power electronic conversion is based on the factors such as waveform quality and switching losses. In recent years several PWM methods gained importance among which CSVPWM is the most popular because of the numerous advantages [1, 2]. It is capable of producing highest available fundamental output voltage with low harmonic distortion in the output current and is suitable for digital implementation. In this method the reference voltage vector is synthesized by time averaging two active states and two zero states in every sampling period, T S. However, CSVPWM suffers from the drawbacks like computational burden and inferior performance at high modulation indices. Moreover, as the CSVPWM is a continuous PWM (CPWM) method the switching losses of the inverter are also high. Hence to reduce the switching losses and to improve the performance in high modulation region several discontinuous PWM (DPWM) methods have been reported in [3-8, 10-12]. The trianglecomparison pulse width modulator compares high frequency carrier wave with the three reference sinusoidal voltages generating gate pulses for the switching devices. Adding a properly selected zero sequence signals, different discontinuous modulating waveforms can be generated. If the augmenting zero-sequence signal is continuous it produces CPWM scheme and if it is discontinuous it results in DPWM schemes. A carrier based generalized PWM method comprising of all DPWM methods is considered as generalized discontinuous PWM scheme (GDPWM) [4-6]. Among the two popular approaches, namely, triangle comparison (TC) and space vector (SV) approaches, SV approach is more general and offers more degrees of freedom in dividing the duration of zero states compared to the TC approach [7-8]. Changing the ratio by which the two zero states are applied in SV approach produces the same effect as the conventional triangle comparison method in which a properly selected zero sequence signal is added to produce different modulators. However to reduce the computational burden involved in SV approach, the concept of imaginary switching times is proposed in [9-12]. The objective was to develop new space vector based GDPWM algorithm without angle and sector determination for reduced current ripples and switching losses at high modulation region. CSVPWM ALGORITHM With a three-phase voltage source inverter (VSI) there are eight possible switching states. The two states, from which no power gets transferred from source to load are termed as null vectors or zero states. The other six states called as active states. The active states can be represented by space vectors as given in (1) and divides the space vector plane into six equal sectors as shown in Figure-1 [6, 8, 12]. 1 2 j( k ) π Vk = Vdc * e 3,k = 1, 2,..., 6. (1) 3 In the CSVPWM strategy, the desired reference voltage vector is generated by time averaging the two nearby active voltage states and two zero states in every sampling time T S. For a given reference voltage V REF at an angle α with reference to V 1 in first sector, the volt-time balance is maintained by applying the active state1 (V 1 ), active state2 (V 2 ) and two zero states (V 0 and V 7 ) together 76

for durations T 1, T 2 and T Z respectively, as given in (2) [12]. Figure-1. Switching states and corresponding voltage vectors of a three phase VSI. I, II, III, IV, V, VI are the sectors. Sin( 60 0 α ) T1 = M * * Ts (2.1) Sin60 0 Sinα T2 = M * * T s (2.2) Sin60 0 TZ = T s T 1 T 2 (2.3) 3V Where M is modulation index, given by M= REF. 2V dc Also in CSVPWM strategy, the total zero voltage vector time, T Z is divided equally between V 0 and V 7. Also in this method, the zero voltage vector time is distributed symmetrically at the start and end of the sampling period in a symmetrical way. Thus, CSVPWM uses V 0, V k, V k+1, V 7, V k+1, V k, V 0 sequence for odd sectors and V 0, V k+1, V k, V 7, V k, V k+1, V 0 sequence for even sectors, respectively. PROPOSED GDPWM ALGORITHM As the CSVPWM is a CPWM technique, switching losses of the inverter are high. Where as in DPWM methods during each sampling period, each of the phases ceases the modulation and the associated phase is clamped to the positive dc bus or negative dc bus. Hence, the switching losses of the associated inverter leg during the period of clamping are eliminated. The performance of the PWM methods depends upon the modulation index. In the lower modulation range, the CPWM methods are superior to DPWM methods, while in the higher modulation range the DPWM methods are superior to CPWM methods. However at all the operating modulation indices, CPWM method has higher switching losses than DPWM methods. Utilizing the generalized phase shift in the DPWM methods, GDPWM algorithm is proposed in [4-6], which has more complexity due to angle calculation. Hence, to reduce the complexity involved, in this paper a novel space vector based GDPWM method has been developed by using the concept of imaginary switching times. The imaginary switching time periods are proportional to the instantaneous values of the phase voltages, and defined as T s T as V a (3.1) Vdc T s T bs V b (3.2) Vdc Ts T cs V c V (3.3) dc Where T S is the sampling period and V dc is the dc link voltage. V a, V b and V c are the phase voltages. Then in every sampling time, the maximum and minimum values of imaginary switching times are calculated as given in (4). T max = max( T as,t bs,t cs ) (4.1) T min = min( Tas,Tbs,Tcs ) (4.2) The active vector switching times T 1 and T 2 may be expressed as [12] T1 = T max T x (5.1) T2 = T x T min (5.2) Tx Tas,Tbs,Tcs and is neither maximum nor minimum switching time. The effective time is the duration in which the reference voltage vector lies in the corresponding active states, and is the difference between the maximum and minimum switching times as given by (6). Where, ( ) T eff = T1 + T2 (6) The sum of zero voltage vector switching times is calculated from the sampling time and effective time as given in (7). T Z = T T (7) S eff In the proposed method the zero state time will be divided between two zero states as T Z µ for V 0 and T Z (1-µ) for V 7 respectively, where µ lies between 0 and 1 [5, 12]. The µ can be defined as µ = 1-0.5(1 + sgn (cos3(ωt + δ)) where ω is the angular frequency of the reference voltage, sgn(y) is the sign function, sgn(y) is 1, 0.0 and -1 when y is positive, zero and negative respectively. The modulation phase angle is represented by δ. When µ = 1 any one of the phases is clamped to the positive bus for 120 degrees and when and µ = 0 any one of the phases is clamped to the negative bus for 120 degrees. The modulation waveforms and their zero sequence signals of few popular DPWM methods including CSVPWM method are shown in Figure-2. 77

When µ=0 and µ=1, DPWMMAX and DPWMMIN are obtained respectively and µ=0.5 results CSVPWM. Thus, the variation of µ generates different modulating waves for different PWM methods. When δ=0, -π/6, -π/3, DPWM1, DPWM2, DPWM3 can be obtained respectively [5, 12]. Thus by varying µ and δ the switching time periods of zero voltage vectors can be changed, so that different DPWM methods can be obtained. Figure-2. Modulation waveforms and their zero sequence signals of different DPWM methods. SIMULATION RESULTS AND DISCUSSIONS To verify the proposed algorithm, a numerical simulation has been carried out on V/f controlled induction motor drive using Matlab/Simulink at no-load for different modulation indices. The total harmonic distortion (THD) of the no-load current is used as a performance index for PWM techniques. The line current waveforms at no-load and harmonic spectra for CSVPWM and some popular DPWM methods for supply frequencies of 40Hz and 50Hz at a switching frequency of 5 KHz are shown in Figures 3 to 8. Their measured %THDs is compared (Table-1). Figure-3a. Measured no-load current and harmonic spectra (% of fundamental) for CSVPWM at Figure-3b. Measured no-load current and harmonic spectra (% of fundamental) for DPWMMAX at 78

Figure-3c. Measured no-load current and harmonic spectra (% of fundamental) for DPWMMIN at Figure-3e. Measured no-load current and harmonic spectra (% of fundamental) for DPWM2 at Figure-3d. Measured no-load current and harmonic spectra (% of fundamental) for DPWM1 at Figure-3f. Measured no-load current and harmonic spectra (% of fundamental) for DPWM3 at 79

Figure-4a. Measured no-load current and harmonic spectra (% of fundamental) for CSVPWM at Figure-4c. Measured no-load current and harmonic spectra (% of fundamental) for DPWMI at modulation index of 0.6 Figure-4b. Measured no-load current and harmonic spectra (% of fundamental) for DPWMMAX at Figure-4d. Measured no-load current and harmonic spectra (% of fundamental) for DPWM1 at modulation index of 0.6. 80

Figure-4e. Measured no-load current and harmonic spectra (% of fundamental) for DPWM2 at Figure-5a. Measured no-load current and harmonic spectra (% of fundamental) for CSVPWM at Figure-4f. Measured no-load current and harmonic spectra (% of fundamental) for DPWM3 at Figure-5b. Measured no-load current and harmonic spectra (% of fundamental) for DPWMMAX at 81

Figure-5c. Measured no-load current and harmonic spectra (% of fundamental) for DPWMIN at Figure-5e. Measured no-load current and harmonic spectra (% of fundamental) for DPWM2 at Figure-5d. Measured no-load current and harmonic spectra (% of fundamental) for DPWM1 at Figure-5f. Measured no-load current and harmonic spectra (% of fundamental) for DPWM3 at 82

Figure-6a. Measured no-load current and harmonic spectra (% of fundamental) for CSVPWM at Figure-6c. Measured no-load current and harmonic spectra (% of fundamental) for DPWMMIN at Figure-6b. Measured no-load current and harmonic spectra (% of fundamental) for DPWMMAX at Figure-6d. Measured no-load current and harmonic spectra (% of fundamental) for DPWM1 at 83

Figure-6e. Measured no-load current and harmonic spectra (% of fundamental) for DPWM2 at Figure-7a. Measured no-load current and harmonic spectra (% of fundamental) for CSVPWM at Figure-6f. Measured no-load current and harmonic spectra (% of fundamental) for DPWM3 at Figure-7b. Measured no-load current and harmonic spectra (% of fundamental) for DPWMMAX at 84

Figure-7c. Measured no-load current and harmonic spectra (% of fundamental) for DPWMMIN at Figure-7e. Measured no-load current and harmonic spectra (% of fundamental) for DPWM2 at Figure-7d. Measured no-load current and harmonic spectra (% of fundamental) for DPWM1 at Figure-7f. Measured no-load current and harmonic spectra (% of fundamental) for DPWM3 at 85

Figure-8a. Measured no-load current and harmonic spectra (% of fundamental) for CSVPWM at Figure-8c. Measured no-load current and harmonic spectra (% of fundamental) for DPWMMIN at Figure-8b. Measured no-load current and harmonic spectra (% of fundamental) for DPWMMAX at Figure-8d. Measured no-load current and harmonic spectra (% of fundamental) for DPWM1 at 86

Figure-8e. Measured no-load current and harmonic spectra (% of fundamental) for DPWM1 at Figure-8f. Measured no-load current and harmonic Spectra (% of fundamental) for DPWM2 at Table.1. Comparison of % THDs of various PWM methods at different modulation indices (M) and supply frequencies. M = 0.8 M = 0.6 M = 0.3 at 40Hz at 50Hz at 40Hz at 50Hz at 40Hz at 50Hz CSVPWM 6.49 7.2 9.13 9.99 8.42 9.38 DPWMMAX 4.31 5.26 6.77 8.11 20.15 21.47 DPWMMIN 4.31 5.20 6.77 8.10 20.15 22.61 DPWM1 3.85 5.45 4.00 11.23 11.80 21.97 DPWM2 3.81 5.41 4.30 9.54 11.34 19.65 DPWM3 3.71 5.04 4.58 9.48 10.44 19.79 From the simulation results it is once again proved that the better performance can be obtained by using CSVPWM at lower modulation indices and DPWM methods at higher modulation indices. Also computational burden involved in SV approach is eliminated with the utilization of imaginary switching times. CONCLUSIONS Among the popular PWM techniques CSVPWM has occupied renowned position because of its numerous advantages as stated earlier. To overcome the limitation i.e. poor performance at high modulation regions and computational burden involved, a simple and powerful novel space vector based generalized discontinuous PWM (GDPWM) algorithm with superior high modulation operating range performance characteristics and reduced computational burden has been developed. This algorithm is utilized to illustrate and compare the performance characteristics of various PWM methods. The waveform quality comparisons in terms of %THDs indicate that CSVPWM at low-modulation and DPWM methods at the high-modulation range have superior performance. Also the execution time and memory required is reduced by eliminating the angle and sector estimation. REFERENCES [1] J. Holtz. 1992. Pulse width modulation-a Survey. IEEE Trans. Ind. Electron. 39(5): 410-420. [2] J. Holtz. 1994. Pulse width modulation for electronic power conversion. Proc. IEEE. 82(8): 1194-1214. 87

[3] Ahmet M. Hava, Russel J. Kerkman and Thomas A. Lipo. 1999. Simple Analytical and Graphical Methods for Carrier-Based PWM-VSI Drives. IEEE Trans. Power Electronics. 4(1): 49-61. [4] Ahmet M. Hava, Russel J. Kerkman and Thomas A. Lipo. 1998. A High Performance Generalized Discontinuous PWM Algorithm. IEEE Trans Ind appl. 34(5): 1059-1071. [5] Olorunfemi Ojo. 2004. The generalized discontinuous PWM scheme for three-phase voltage source inverters. IEEE Trans. Ind. Electron. 51(6): 1280-1289. [6] T. Brahmananda Reddy, J. Amarnath, D. Subba Rayudu and Md. Haseeb Khan. 2006. Generalized Discontinuous PWM Based Direct Torque Controlled Induction Motor Drive with a Sliding Mode Speed Controller. IEEE Proc. Power Electronics, Drives and Energy systems for Industrial Growth. PEDES 06, New Delhi, India, Paper No. 3D-11. [7] Keliang Zhou and Danwei Wang. 2002. Relationship between Space Vector Modulation and Carrier-Based PWM: A Comprehensive analysis. IEEE Trans. Ind. Electron. 49(1): 186-196. [8] G. Narayanan and V. T. Ranganathan. 2000. Triangle comparison and space vector approaches to Pulse width modulation in inverter-fed drives. J. Indian Inst. Sci. Vol. 80, pp. 409-427. [9] Joohn-Sheok Kim and Seung-Ki Sul. 1995. A novel voltage modulation technique of the space vector PWM. In: Proc. IPEC, Yokohama, Japan. pp. 742-747. [10] Dae-Woong Chung, Joohn-Sheok Kim and Seung-Ki Sul. 1998. Unified voltage modulation technique for real-time three-phase power conversion. IEEE Trans. Ind. Applicat. 34(2): 374-380. [11] Arbind Kumar. 2004. Direct Torque Control of Induction Motor is using imaginary switching Times with 0-1-2-7 AND 0-1-2 Switching Sequences: A Comparative Study. The 30 th Annual Conference of the IEEE, IES. pp. 1492-1497. [12] T. Brahmananda Reddy, J. Amarnath and D. Subba Rayudu. 2006. New Hybrid SVPWM Methods for Direct Torque Controlled Induction Motor Drive for Reduced Current Ripple. IEEE Proc. Power Electronics, Drives and Energy systems for Industrial Growth, PEDES 06, New Delhi, India. Paper No.3B- 20. 88