Remote Site Monitoring

Similar documents
REMOTE SITE MONITORING

Appendix G: IFR 8800 Test Procedures MAINTENANCE GUIDE.

Lynx. RoIP Gateway DISPATCH LYNX MOBILE. Optional serial ports provide remote control of radio configuration over the VoIP network.

X-Band Redundant LNA Systems

C-Band Redundant LNA Systems

UN2 - Universal controller Building automation s missing link

INSTALLATION and OPERATION INSTRUCTIONS. FOR FiberLink BI-DIRECTIONAL AMPLIFIER WITH DIVERSITY MW-FBDA-800AB-50W-DIV

Trio Q Data Radios. Licensed UHF Ethernet and Serial Data QR450

Solid State General Communication Power Amplifier

SGT-LP Series PDH Microwave Radio Technical Overview

innovative technology to keep you a step ahead

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O PRODUCT INFORMATION B&B ELECTRONICS

Trio Q. Licensed UHF Ethernet and Serial data radio. QB450 Full Duplex

Specification Sym Notes Minimum Typical Maximum Units 900 MHz Operating Frequency Range MHz

INSTALLATION AND OPERATING MANUAL

Trio Q. Licensed UHF Ethernet and Serial data radio. QH450 Hot Standby Full Duplex

Phase Combined Systems

5000 Series Receiver Systems

Wireless Interface RAD-ISM-900-SET-BD-BUS Two-way (point-to-point) Monitoring and Control with Expandable I/O Options User Manual

SOUTHERN AVIONICS COMPANY. SE125 Transmitter. SE125 Transmitter 1-1

HydroLynx Systems, Inc.

Model 1791 VHF Radio User's Manual

VEB Series. TCP/IP Network Matrix PA System. 32 simultaneous Audio Buses. Up to 60 Network Paging Consoles. Up to 128 Audio Output channels

Features 100A400AM20. 4kHz 400MHz Class A Portable Full VSWR tolerant CE & RoHS compliant High Efficiency

MATERIAL SPECIFICATIONS FOR WIRELESS LINK

SPECIAL SPECIFICATION 6744 Spread Spectrum Radio

SOLUTIONS FOR AN EVOLVING WORLD RFL Programmable FSK Powerline carrier system

Rockwell Collins, Inc. VHF Users Manual

R&S FU129 Antenna Filter Unit Antenna switching, rotator control and signal attenuation, amplification and filtering

Data Acquisition Modules/ Distributed IO Modules

This is by far the most ideal method, but poses some logistical problems:

400W C-Band GaN Compact Outdoor SSPA. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

MAINTENANCE MANUAL TRANSMITTER/RECEIVER BOARD CMN-234A/B FOR MLSU141 & MLSU241 UHF MOBILE RADIO TABLE OF CONTENTS

R40 Mk III AIS Base Station

120W UHF Transmitter/Repeater

S O P H I S T I C A T E D A U T O M A T I O N

MASTR II AUXILIARY RECEIVER 19D417546G7 & G8 & ANTENNA MATCHING UNITS 19C321150G1-G2. Maintenance Manual LBI-30766L. Mobile Communications

A01-eNETL2TUV_Manual_RevH.doc. GE MDS enetl2t/u/v Manual P/N A01 Rev H

Part Numbers. SNAP-AIARMS-i SNAP-AIARMS-i-FM* SNAP-AIVRMS-i SNAP-AIVRMS-i-FM* SNAP-AIMA-i. SNAP-AIMA-iSRC SNAP-AIMA-iSRC-FM* SNAP-AIMA2-i

Multilin DGT. Distributed Generation Trip Control Fast & Wireless Trip of Distributed Generators. Control. Advanced Communications

Advanced Test Equipment Rentals ATEC (2832) Contents

SCADA and Telemetry Solutions. SCADALink IO900. Modular Wireless I/O System. User Manual Version V1.3 for SCADALink IO900 BENTEK SYSTEMS LTD

FM TRANSMITTER 5kW-10kW

ZZxD-Nx-xR Series. Wireless Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

Cross-Connect Interface

150W1000B. Features. 150 watts CW 80MHz 1000MHz Class A Portable Full VSWR tolerant CE & RoHS Compliant High Efficiency

FEATURES: Reduced Depth. Output RF Power Hold. Easily Accessible Diagnostic Port. Programmable Alarms. Event And Maintenance Logs. Ethernet Interface

Solid State Broadband High Power Amplifier

IntelPage 5W (POCSAG) Transmitter

Guardian and DL3282 Modem Interface Technical Service Application Note

Agilent N9923A FieldFox RF Vector Network Analyzer 2 MHz to 4/6 GHz. Data Sheet

8450 Series CellGuard TM Power / VSWR Monitors

WIRELESS MODBUS GATEWAY WGW410

Portable Multi-Channel Recorder Model DAS240-BAT

Digital Microwave Radios

Kenwood USA Corporation

IC-400pro - RADIOAFICION.COM

100U1000. Features. 100 watts CW 100kHz 1000MHz Class A Portable Full VSWR tolerant CE & RoHS Compliant High Efficiency

Keysight Technologies N9320B RF Spectrum Analyzer

XMU+ Environmental, Safety and Specifications

Agilent N9320B RF Spectrum Analyzer

Preliminary. 4-Channel RTD/4-20 ma Wireless Sensor Node SN24R420-4

400W C-Band GaN Compact Outdoor SSPA. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

Trio K-Series. License-free serial data radio KR900 KR240 KP900 KP240 KB900 KB240

MX800 BASE STATION SPECIFICATIONS

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

Specifications for: OSOP Sixaola4-V4

TELESTE AC AMPLIFIER MODULES

TECHNICAL NOTES MT-4 Radio Systems TN182 Battery Level Reporting and Remote P25 Test Tone

Mission Critical DAS Solution

Airmux-400 Broadband Wireless Multiplexer

125W Ku-Band Compact Outdoor SSPA. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

150W Ku-Band Compact Outdoor 1:1 Redundant System. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

ARP Radio Modem & Router Datasheet

RM24100D. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

Overview. Features. Technical Data Sheet 1 / 5. Power Amplifier XMV8140-D

Trio E to Trio Q Product Migration Guide

Challenging Communication Boundaries. Ser i es I I

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

Trendmaster * Dynamic Scanning Module

7RU SSPA Chassis. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

TECHNICAL NOTES Technical Notes for Tuning, Installing, Maintaining and Servicing MT-3 and MT-4 Radio Systems

MT3200A TRAVELING WAVE TUBE MEDIUM POWER AMPLIFIER

Demo Circuit DC550A Quick Start Guide.

MOTOBRIDGE IP INTEROPERABILITY SOLUTION

MODES AND PROTOCOL HANDLING

CXE880 FIBRE OPTIC NODE

Characteristic Sym Notes Minimum Typical Maximum Units 2, 3 or 4-wire 100 ohm Platinum RTD Sensor Inputs

CXE880 FIBRE OPTIC NODE

ELITE PRO. Automation Components, Inc.

FL WLAN 24 AP XDB and RAD XDB

F2A3X Frequency to Analog Converter Module

LBI-31807D. Mobile Communications MASTR II REPEATER CONTROL PANEL 19B234871P1. Maintenance Manual. Printed in U.S.A.

ULTRA BROADBAND RF over FIBER Transceiver OZ1606 Series Premium Grade 6 GHz

RM24100D. Introduction. Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

DTS 4210.timecenter. Swiss Time Systems. High precision time server, grandmaster and PRC

Model Model Digital Power Meter. Digital Power Sensor Digital Display & Analog RF Systems

Accutech BR20. DIN rail mounted base radio

Specifications MPS 602

Transcription:

Remote Site Monitoring FEATURES AT A GLANCE Codan Radio Communications now offers Remote Site Monitoring options that provide live site information, giving you the power to respond intelligently to communications failures that affect your system today, and to prevent the ones that will happen tomorrow. REMOTE SITE MONITORING SOLUTIONS A Remote Site Monitoring package can be added to any Codan MT-4E series repeater or base station. Real-time or historical data collected at the site is passed to a centrally located PC equipped with the APEX software over one of the following backhaul interfaces: 1. Existing Radio (RF) Link: a. Directly from the site, or b. Relayed via intermediate remote repeater sites 2. IP Connection on a Local Area Network (LAN) NOTE: RF Link must transmit Remote Site Monitor data in Analog mode only. Console Tone Remote SiteCommander SiteCommander Remote Gateway PC with APEX software IP SiteCommander Remote Radio Site Remote Radio Site Link Repeater Summit Summit IP Connection LAN Remote Radio Site 12-20324-EN Issue 2 7/2016

Remote Site Monitoring MT-4E SYSTEM INTEGRATION Codan MT-4E series radios interface with the Remote Site Monitoring on-site controller via direct wireline connections to analog and digital I/O available on the system subrack. The lines that can be monitored include: Codan MT-4E Inputs/Outputs to Controller Digital Inputs MT-4E Subrack Pin Rx COR J1-7 Rx A/D Mode J4-10 Rx Health (Active Low) J6-2 Tx PTT In J1-3 Tx PTT Out J5-6 Tx Forward Power Alarm J5-2 Tx Health (Active Low) / Tx VSWR Power Alarm (RSS Jumper Selectable) J5-3 VHF / UHF 30W PA Low Forward Power Alarm J5-10 VHF / UHF 30W PA High VSWR Alarm J5-11 VHF / UHF 30W PA General Fault Alarm J5-14 Digital Outputs Tx PTT In J1-3 Rx Squelch Override J4-9 Analog Inputs Line Voltage - 13.8 V J4-5 Regulated Voltage - 9.5 V J4-7 Rx RSSI J5-7 Other external sensors that can interface with the controller include: External Sensor Inputs to Controller Digital Inputs External Power Amplifier Summary Alarm External AC Power Supply Alarm Output Door Alarm Antenna and Cable VSWR Alarm Device External 60-100 W Amplifier External AC to DC Power Supply Door Alarm Connector Antenna and Cable Monitor Analog Inputs AC Line Voltage Ambient Temperature DC Current RF Power: Forward and Reverse (VSWR) Antenna & Cable: Forward and Reverse (VSWR) AC Voltage Sensor Temperature Sensor Differential Voltage Sensor Bidirectional Power Sensor Antenna and Cable Monitor www.codanradio.com

Controller Specifications Controller Summit SiteCommander Codan Application Monitoring over IP Monitoring over RF Link Management Software Mounting APEX 19 Rack (1RU) Power Input +8.0 VDC to +48.0 VDC +11.0 VDC to +20.0 VDC Average current consumption 250 ma @ +12.0 VDC 60 ma @ +13.5 VDC (15 ma in sleep mode) Operating Temperature -40.0 C to +65.0 C Interface 10/100/1000 Base-T Ethernet 1200/2400 bps FFSK over RF Gateway Interface via Ethernet or Serial Digital Inputs Number available (default) 48 8 Input range Supported input types Digital Outputs 0 VDC to +60.0 VDC Contact closure, switches, open collector, voltage inputs Number available (default) 12 8 Output range Supported output types Analog Inputs Up to +50.0 VDC @ 150 ma Open Drain Number available (default) 32 8 Input range Supported input types Filters Analog Outputs 0 VDC to +25.0 VDC or 4 ma to 20 ma 16 bit resolution Hold time, threshold trigger set points per input, software defined qualifiers 0 VDC to +5.0 VDC or 0 VDC to +25.0 VDC or 0 VDC to +100.0 VDC (external adapter) 8 x10bit A/D Hold time, threshold trigger set points per point Number available (default) 4 N/A Output range Up to +50.0 VDC @ 150 ma N/A Summit Punch Block (Included)

Remote Site Monitoring SENSOR SPECIFICATIONS Temperature Sensor (SiteCommander) Application RF Link (SiteCommander) ONLY Span -55 to +125 C Accuracy -25 to +100 C ± 1.5 C (nominal) -55 to +125 C ± 2 C (nominal) Current Draw 2 ma per sensor Designed to monitor ambient temperature in an enclosed environment. RJ45 connection provides plug-in connection to the SiteCommander without using analog inputs. Temperature Sensor (Summit & SiteCommander) Application The Outdoor Temperatures Extended Reach Sensor detects outdoor ambient temperature which can be used over much longer leads than other temperature sensors (up to 100 feet) with the Summit or SiteCommander. IP (Summit) and RF Link (SiteCommander) Span -40 to 49 C Accuracy ± 1.5 C Operating relative humidity 5% to 95% non-condensing Cable length 10 feet (3m); 50 feet (15m); 100 feet (30m) Mounting Clip Included DC Current Sensor The sensor/shunt combination is designed to measure DC current. Includes a Differential Voltage Sensor (also sold separately for voltage measurements that are not referenced to ground) VDC In 7 to 20 VDC Current 2 ma Max. Operating Temp -40 to +65 C +IN/-IN Differential Input Voltage = ± 0 125 mv Common Mode Voltage (CMV) = 0 65 VDC AOUT 0 5 VDC Dimensions 52 mm x 36 mm x 28mm (L x W x H) Weight 15 g 100mV DC Ammeter Shunt 5, 20, 30 or 50 AMP AC Voltage Sensor The AC Voltage Sensor will measure AC voltage in a single phase system. Environmental Functional temperature -25 to +70 C Input 0 150 VAC, 0 300 VAC Output 0 5 VDC >1 kω Enclosure Snap on to DIN rail 35 x 7.5 mm Door Contact Sensor The sensor changes voltage when a magnet mounted near the sensor switch is moved away from or closer to the sensor switch. Loop Type Closed Electrical Configuration Normally Open Maximum Switching Voltage 160 VDC Maximum Switching Current 0.4A Cable Length 50 feet (15 meters) 100 feet (30.5 meters) 150 feet (46 meters) Maximum Gap 1 1/4 (31.75 mm) www.codanradio.com

SENSOR SPECIFICATIONS (CONTINUED) Bidirectional Power Sensor Bi-directional power monitor sensors provide a DC voltage output corresponding to an input RF signal. Provides precise forward and reflected power measurements. Bandwidth 50 MHz Frequency Range 118-230 MHz 380-512 MHz 700-869 MHz 806-960 MHz Measurement Range 5 W - 1000 W Insertion Loss (typical) 0.1 db VSWR 1.1:1 Maximum RF Connectors N Type DC Connectors RCA-F standard Impedance 50 Ohms Dimensions 1.375 x 2.25 x 1.25 inches (3.5 x 5.7 x 3.2 cm) Weight 0.5 lb (0.2 kg) Antenna and Cable Monitor Antenna and Cable Monitors are designed to detect antenna and cable faults that transmitter-internal VSWR monitors may not detect, and also provides accurate in-line power measurement functionality. VSWR 1.07 Frequency Range 136-225 MHz 225-520 MHz 470-960 MHz Measurement Range 2.5 W - 100 W or 12.5 W to 500 W Insertion Loss 0.1 db RF Connectors N Type Alarm Set Point (1.3 to 2.5) to 1 Impedance 50 Ohms Reflected Directivity 30 db Current Draw 130 ma @ 13.8 Vdc

SOFTWARE SPECIFICATIONS Software APEX and APEX EMS Key Features Server Core Requirements Operating System Processor Memory Network Card Hard Drive Client Requirements Operating System Processor Memory Network Card Hard Drive Resolution License Options APEX APEX EMS Event logging keeps track of incidents Immediate notification of alarm conditions Real-time presentation by polling of operator selected data Alarms can be sent to one or many operators Visual, audible and pop-up alarm notification Custom background map/graphics to suit your application Permission levels settable to company defined security measures Outputs at a given site can be mapped to change based on an event occurring at the same site or multiple sites Windows Server 2008 or higher-recommended Intel Generation 3 (Minimum) 4 GB RAM (Minimum) 10/100 Ethernet Card 500 MB free space-recommended Windows XP/Vista/7/8/10 Intel Generation 2 (Minimum) 128 MB RAM 10/100 Ethernet Card 10 GB 7200 RPM, 20 MB free space 1024x768 (Minimum) 10 simultaneous users; unlimited number of sites. 10 simultaneous users; unlimited number of sites. Adds SNMP Network Manager functionality that captures SNMP traps from other networked devices and displays them on APEX. CODAN is a trademarks of Codan Limited. Other brand, product and company names mentioned in this document are trademarks or registered trademarks of their respective holders. Values noted are typical. Equipment descriptions and specifications subject to change without notice or obligation. CODAN RADIO COMMUNICATIONS 12-20324-EN Issue 2 7/2016 www.codanradio.com Australia: +61 8 8305 0528 Canada: +1 250 382 8268 US: +1 571 919 6432 UAE: +971 44 53 72 01 LMRsales@codanradio.com