CR Retrofit Kit Package Configuration Integrated PACS

Similar documents
DR Retrofit Kit Package Configuration Integrated PACS

DR Retrofit Kit Package Configuration DICOM

COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS

CR30-ORACLE CR. with Office Viewer. A Revelation in Computed Radiography. Innovations in Digital Imaging. Solution for Quantum Medical Imaging

Solutions Page Content ImagePilot. Primary keywords: Digital radiography Computed radiography Image viewing and storage

Classic Image Suite. Legendary Reputation...Sensitivity to your budget 'LYLVLRQ RI &DUHVWUHDP

Examion. New. Image Acquisition and Diagnostics. R a d i o D i g i t a l e. examion aqs veterinray software.

Touch Screen Technology. Classic WAIV. with Touch Screen Technology. Legendary Reputation...Sensitivity to your budget

See what you need to see, and see it anywhere.

The Flash IIP Console is the heart of every FCR system. It s designed to maximize productivity in the busiest environments.

DELWORKS DR MEDICAL. take the next step

Contents. Densely aligned CCD sensors with our own unique technology

C506-E064. Full digital system. Printed in Japan A-NS

CR35-SP+ Computed Radiography (CR) System. Innovations in Digital Imaging

Grubstr- 6-8 D Vörstetten Tel.: +49(0) Fax: +49(0) Steinhart Medizinsysteme GmbH

UP-D74XRD. DICOM Digital Imager.

Open. the Digitized world. Fuji Computed Radiography

TECHNICAL DATA. GIOTTO IMAGE SDL/W is pre-arranged for Full Field Digital Biopsy examination with the patient in prone position.

K ODAK D RYV IEW 8900 LASER IMAGER

The Versatile and Powerful ACLxy. ACLxy

FCR XL-2 and FCR XC-2. High-quality digital x-ray that's perfect for your private practice.

SAMSUNG SMART DIGITAL RADIOGRAPHY. XGEO GU60A series REDEFINING ERGONOMICS

A True Innovation in Non-Destructive Testing System FUJIFILM COMPUTED RADIOGRAPHY. Series 4 CR

China Resources Wandong Medical Equipment Co., Ltd. High Frequency 50kW Digital RF System - HF51-5

DKS1530 The perfect evolution of a minilab

CXDI-70C WIRELESS SPECIFICATIONS

PLD5600A High Frequency Digital Gastrointestinal &DR System(630mA)

THE SPEED OF DIGITAL. THE POWER OF ANALOG.

Digital Film Imager UP-DF550

CT-XGEO GC FTW EN

SECTION I - CHAPTER 1 DIGITAL RADIOGRAPHY: AN OVERVIEW OF THE TEXT. Exam Content Specifications 8/22/2012 RADT 3463 COMPUTERIZED IMAGING

HIGH-RESOLUTION DIGITAL PHOTOSPOT SYSTEM years, CMT s technology is today proven in more than 4,500 clinical installations PRODUCT SPECIFICATION

User Manual Veterinary

The DR system in a suitcase for mobile X-ray

Digital X-ray with familiar cassette handling

ARCO Rk.5 Digital Mobile C-Arm

COMPUTED RADIOGRAPHY (CR)

INNOVATION BY DESIGN. Toshiba A History of Leadership REMOTE CONTROL R/F SYSTEM

ZView ver.2 DR Console Software. User Manual. (for HUMAN) Manual Version : 2.1 Revision : 002

VISION u UNIVERSAL AUTOPOSITIONING

DKS1550 High performance digital minilab

IMAGELINK. The speed. digital scanners 2400dV plus 3000dV plus PowerFilm application software. The power of analog.

General Hospital Catalog

State of the art technology a nd excellent images. DR flat panel upgrade kit for existing X-ray systems for operation without cassettes

Image Display and Perception

Digital Imaging Considerations Computed Radiography

Get more from your images with Symphony Image Processing

Medici DR Systems. DR flat panel upgrade kit for existing X-ray systems for operation without cassettes. Medici DR upgrade kit.

SunRise 3 in 1 Microfilm Scanners Sixth Generation APOLLO HS. Base. 3 in 1 Modular Design highly reliable

12 x 12 anti-glare screen provides a clear, detailed view of your microform.

Get more from your images with Symphony Image Processing

The wonderfully light, portable Leonardo DR nano system for X-ray examinations anywhere, any time

MUSICA Nerve Center. Artificial Intelligence. Intelligent tools for your Digital Radiography workflow. Fluoroscopy. Workflow Optimization

Digital radiography. bucky table and wall stand as a dual detector or wireless system. Amadeo DR Systems

Fujifilm Medical Systems Product Profiles. Fujifilm s Medical Imaging Solutions Lead the Way

Digital X-ray with familiar cassette handling

Digital Image Management: the Basics

GE Healthcare. Senographe 2000D Full-field digital mammography system

Things you may want to know

VISION u UNIVERSAL AUTOPOSITIONING

The Evaluation of Collimator Alignment of Diagnostic X-ray Tube Using Computed Radiography System

A Practical Overview of the Clinical and Operational Impact of Computed Radiography(CR) Implementations. Shirley Weddle, RT(R)(M), CIIP, BBA

The wonderfully light weight, portable Leonardo DR nano system for X-ray examinations anywhere, any time

KODAK EKTASCAN IR Laser Imaging Film / 1356 / EIR

DX-M CR SOLUTION DX-M. The next generation CR System for Digital Mammography and General Radiography.

PACS Fundamentals. By: Eng. Valentino T. Mvanga Ministry of Health and Social Welfare Tanzania

Small Animal Radiographic Techniques and Positioning COPYRIGHTED MATERIAL

Computed Radiography

P R O D U C T C A T A L O G ( E G Y P T ) V E R S I O N 1. 1 / M A R C H

Clinical and management aspects of digital imaging and PACS

ir7200 Digital Network Production System Win every time with high quality, high speed short-run print work

Digital Imaging CT & MR

KIP 2300 HIGH PRODUCTION CCD SCAN SYSTEM

Digital Radiography X-Ray System. X Twin with X Mobil Roesys GmbH [rshsmi] 1/11

3/31/2011. Objectives. Emory University. Historical Development. Historical Development. Historical Development

Digital X-ray. in the modern medical practice. Digital X-ray 0482 FDA. Digital Image Management

Portable Digital X-ray

ECOVIEW 9 / ECOVIEW 9 PLUS Digital Radiographic System

VistaScan Combi View - efficiency without compromise

The European Manufacturer Group. The European Manufacturer Group

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

New spectral benefi ts, proven low dose

Chairside digital. Imaging Plate System

ON THE WAY TO DIGITAL RADIOGRAPHY

Switch to affordable, efficient digital microfilm scanning

Simplifying Digital X-RAY FOR Chiropractic DIGITAL X-RAY RETROFIT COMPLETE DIGITAL X-RAY ACQUISITION & IMAGE MANAGEMENT

BCA 9SK. 60 Hz on request Absorbed current on Stationary Vac and Vac in fluoro mode

Cassette DR Solution. FDR D-EVO G43i. Square shaped cassette enabling enhanced operability and multipurpose use ISS. Wireless

K ODAK D IRECTV IEW CR 950 SYSTEM

BCA 9RK. 60 Hz on request Absorbed current on Stationary Vac and Vac in fluoro mode

Spokane Industries Computed Radiography Implementation Experience. David Jolin Technical Sales

Installation & User Manual Micro-Image Capture 7

ECOVIEW 9 / ECOVIEW 9 PLUS Digital Radiographic System

imagespectrum ADVANCED DIGITAL IMAGE MANAGEMENT SYSTEM Get a Better Handle on the Big Picture

BENNETT RENAISSANCE SERIES. Dedicated to Quality, Innovation and the Chiropractic Profession

you can Portable DR with High Sensitivity. Less is more. CXDI-501C DIGITAL RADIOGRAPHY SYSTEM

A Novel 12-bit Grayscale Topology PACSmate Revolutionary GrayBoost Technology

Digital radiography: Practical advantages of Digital Radiography. Practical Advantages in image quality

Mammography Solution. AMULET Innovality. The new leader in the AMULET series. Tomosynthesis, 3D mammography and biopsy are all available.

KODAK DIRECTVIEW CR Mammography Feature User s Guide

Transcription:

CR Retrofit Kit Package Configuration Integrated PACS Description: The CR Retrofit Kit Integrated PACS makes the use of analogue x-ray films, the use of film cassettes and intensifying screens, the use of a darkroom, a processor and processing chemistry obsolete. The digital information for the various images, necessary for an x-ray examination, is obtained by means of CR s/imaging Plates, which are replacing the conventional method of using cassettes/films. The digital information, stored on the CR-Imaging Plate is scanned by the CR-Reader and is sent to the Capture Console, where by means of the DX-Easy Imaging Acquisition Software the x-ray image is obtained and can be evaluated on screen. The DX-Easy Imaging Processing Software allows the radiologist to enhance and examine the image exactly as required to make a precise diagnosis. The image can be exported to different media or a patient CD made as required. Only the diagnosis related images are printed by means of the COLENTA DICOM 1) Printer onto Dry Imaging Film for keeping in the patient file. A CD-writer in the PC of the Capture Console allows images to be written and to create a Patient-CD, to be kept with the patient file. The PACS 2) Configuration allows to set up a complete independently working IT-System in the x-ray department, including Image Archiving facility and connection of additional Workstations. The amount of workstations to be provided, is limited to 4 units. 1) DICOM Digital Imaging and COmmunications in Medicine 2) PACS Picture Archiving and Communication System CR_Integrated PACS_12_en.docx - 1 / 7-2017-11-28

consists of: CR Retrofit Kit Package Configuration Integrated PACS 1) Capture Console 1a) 23 TFT Touchscreen Console Monitor * ) 23" colour TFT Monitor 1280x1024 resolution *) When diagnosis to be done on Console Monitor, it is recommended to use a Diagnostic Monitor. 21.3 TFT 2M colour 21.3 LED 2M 21.3 LED 3M 21.3 LED 5M Resolution 1600 x 1200 1600 x 1200 2048 x 1536 2560 x 2048 Response Time 35ms 40ms 40ms 25ms Brightness (max) 760 cd/m² 1200 cd/m² 1200 cd/m² 1200 cd/m² Contrast Ratio 1200:1 1400:1 1400:1 1200:1 View Angle 176 176 176 176 Complete List and Prices of Diagnostic Monitors on request 1b) Colenta DX Easy Imaging Capture Console: Operating system Windows 8.1 64Bit Processor min. Intel Core i5, 8 GB Memory HDD S-ATA 1 TB 2x GBit LAN controller Intel VGA graphic controller with 24 bit color depth Video Mode of graphic card supports OpenGL V1.1 min. Screen resolution 1024x768 pixel CD/DVD-writer, Keyboard and mouse Preinstalled and tested by Colenta 1c) DX Easy Imaging Acquisition Software and DX Easy Imaging Processing Software Module image diagnosis Module viewer standard - Zoom, Rotation and mirror (turn to the left, turn to the right, flip, mirror) - Window levelling (Gradation - brightness, contrast and gamma value) - Contrast inversion, Measurement (Angle, Distance, Outline) - Radiography Marker (Left / Right markers), Add Text Module patient viewer, CD/DVD 1d) DX Easy Imaging DICOM print module (1 printer) 1e) Colenta DX Easy Imaging PACS software 1 user module PACS archiving module final archiving on CD/DVD module data compression module image diagnosis module viewer standard module patient viewer, CD/DVD Note: Several software modules are available for the Colenta Acquisition Software. Please refer to the price list. CR_Integrated PACS_12_en.docx - 2 / 7-2017-11-28

OPTIONAL: UPGRADE RAID1 SYSTEM for combined server (> 25.000 images / year) to 3TB: Colenta DX Easy Imaging Workstation Kit Note: The PACS Configuration allows to set up a connection of additional Workstations. The amount of workstations to be provided, is limited to 4 units. consisting of: 1) Workstation PC 1a) 19 TFT Touchscreen Console Monitor * ) 19" colour TFT Monitor 1280x1024 resolution *) When diagnosis to be done on Console Monitor, it is recommended to use a Diagnostic Monitor. 21.3 TFT 2M colour 21.3 LED 2M 21.3 LED 3M 21.3 LED 5M Resolution 1600 x 1200 1600 x 1200 2048 x 1536 2560 x 2048 Response Time 35ms 40ms 40ms 25ms Brightness (max) 760 cd/m² 1200 cd/m² 1200 cd/m² 1200 cd/m² Contrast Ratio 1200:1 1400:1 1400:1 1200:1 View Angle 176 176 176 176 Complete List and Prices of Diagnostic Monitors on request 1b) Colenta DX Easy Imaging Capture Console: Processor min. Intel Core i5 4096 MB Memory 2x HDD S-ATA 320 GB - RAID1 2x GBit LAN controller Intel VGA graphic controller with 24 bit color depth Video Mode of graphic card supports OpenGL V1.1 min. Screen resolution 1024x768 pixel CD/DVD-writer Keyboard and mouse Operating system Windows 8.1 Preinstalled and tested by Colenta 1c) DX Easy Imaging Acquisition Software and DX Easy Imaging Processing Software Module image diagnosis Module viewer standard - Zoom - Rotation and mirror (turn to the left, turn to the right, flip, mirror) - Window levelling (Gradation - brightness, contrast and gamma value) - Contrast inversion - Measurement (Angle, Distance, Outline) - Radiography Marker (Left / Right markers) - Add Text Module patient viewer, CD/DVD CR_Integrated PACS_12_en.docx - 3 / 7-2017-11-28

2) CR Reader Image Plate HighCap Xr 14 x 17 (35 x 43 cm) 14 x 14 (35 x 35 cm) 10 x 12 8 x 10 24 x 30 cm 18 x 24 cm 15 x 30 cm HighCap XMr (useable for Mammography) 14 x 17 (35 x 43 cm) 14 x 14 (35 x 35 cm) 10 x 12 8 x 10 24 x 30 cm* 18 x 24 cm* 15 x 30 cm *) also cassette size for mammography HighCap XLr (useable for Mammography) 14 x 17 (35 x 43 cm) 14 x 14 (35 x 35 cm) 10 x 12 8 x 10 24 x 30 cm* 18 x 24 cm* 15 x 30 cm *) also cassette size for mammography Processing Capacity 14 x 17 up to 47 IPs/hr 14 x 17 up to 47 IPs/hr 14 x 17 up to 87 IPs/hr Grayscale resolution 12 Bit 12 Bit 12 Bit Reading Specification 10 / 5 pixel/mm 20 / 10 / 5 pixel/mm 20 / 10 / 5 pixel/mm Pixel Size 100um 100um / 50um (Mammography) 100um / 50um (Mammography) Weight 39 kg (86 lbs.) 39 kg (86 lbs.) 99 kg (218 lbs.) Dimensions (WxDxH) Power Supply Conditions Environmental Conditions 560 x 540 x 392 mm (22 x 21 x 15 ) Humidity: 15-80%RH 560 x 540 x 392 mm (22 x 21 x 15 ) Humidity: 15-80%RH 590 x 380 x 810 mm (23 x 15 x 32 ) Humidity: 15-80%RH CR_Integrated PACS_12_en.docx - 4 / 7-2017-11-28

3) Colenta CR Imaging Plates and s: 3a) General X-Ray: Order Number DX16251625 DX15189368 DX15677470 DX15189370 DX16251663 DX15188596 DX15677432 DX15188601 DX15677420 DX15677822 Description 35x43cm (14 x17 ) 35x43cm (14 x17 ) 35x35cm (14 x14 ) 35x35cm (14 x14 ) 15x30cm 15x30cm 3b) Mammography X-Ray: Order Number DX15779060 DX16163696 DX15779072 DX15779058 DX16163684 Description adapter for CH CASS 24x30 CR_Integrated PACS_12_en.docx - 5 / 7-2017-11-28

Colenta Dry Laser Imager - High Efficiency - Mammo Applicability HighCap Xp HighCap XLp Recording Method Laser exposure thermal development system Applicable Film Film loading MEDIPHOT DRY IMAGING FILM DL (100/150 sheets/pack) 35 x 43cm (14 x 17 ), 26 x 36cm (10 x 14 ), 25 x 30cm (10 x 12 ), 20 x 25cm (8 x 10 ) MEDIPHOT DRY IMAGING FILM DLM for Mammography (150 sheets/pack) 26 x 36cm (10 x 14 ), 25 x 30cm (10 x 12 ), 20 x 25cm (8 x 10 ) Daylight film loading Film magazines 2 trays online 3 trays online Processing Capacity approx. 80 sheets/hour at 35 x 43cm (14 x 17 ) approx. 100 sheets/hour at 20 x 25cm (8 x 10 ) approx. 110 sheets/hour at 35 x 43cm (14 x 17 ) approx. 160 sheets/hour at 20 x 25cm (8 x 10 ) Pixel size Recording gradation Image Memory Density adjustment Input channels Power Supply Conditions Environmental Conditions 50 um (508 dpi) 14 bits (16383) 1 GB Automatic density correction DICOM network input x 1 channel only Humidity: 15-70%RH Weight 104 kg (229.3 lbs.) 160 kg (353 lbs.) Dimensions (WxDxH) OPTIONS 610 x 630 x 893 mm (24 x 25 x 35 ) Optional Tray Floor Fix Kit 600 x 585 x 1090 mm (24 x 23 x 43 ) w/o sorter 600 x 585 x 1390 mm (24 x 23 x 55 ) - with sorter 4-bin sorter CR_Integrated PACS_12_en.docx - 6 / 7-2017-11-28

MEDIPHOT DL Dry Laser Imaging Film: Matching with Colenta HighCap Xp/XLp Printers, the low fog, consistently clear, the Dry Laser Film DL delivers high density images at neutral colour tone, comparable to those from conventional wet processing. Film size Quantity/Package 35 x 43cm (14 x 17 ) 100 sheets + 1 protective sheet 26 x 36cm (10 x 14 ) 150 sheets + 1 protective sheet 25 x 30cm (10 x 12 ) 150 sheets + 1 protective sheet 20 x 25cm (8 x 10 ) 150 sheets + 1 protective sheet MEDIPHOT DLM Dry Laser Mammography Imaging Film: Matching with Colenta HighCap Xp/XLp Printers, the low fog, consistently clear, the Dry Laser Film DLM delivers high density images (D-max of 4.0) at a blue film colour, and better sharpness compared to DL. The DLM also has adequate image quality for mammography. Film size Quantity/Package 26 x 36cm (10 x 14 ) 150 sheets + 1 protective sheet 25 x 30cm (10 x 12 ) 150 sheets + 1 protective sheet 20 x 25cm (8 x 10 ) 150 sheets + 1 protective sheet CR_Integrated PACS_12_en.docx - 7 / 7-2017-11-28