With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U 55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load independent DC voltage proportional to the measured value. he transducer fulfils all the important requirements and regulations concerning electromagnetic compatibility EMC and Safety (IEC 00 resp. EN 00). It was developed and is manufactured and tested in strict accordance with the quality assurance standard ISO 00. Features / Benefits Measuring input: AC voltage, sine or distorted wave forms, RMS value measurement Measured variable AC voltage Measuring range limits 0 0 to 0 0 V Measuring output: Unipolar and live-zero output variables Measuring principle: Logarithmic method AC/DC power supply / Universal Standard version as per Germanischer Lloyd Fig.. ransducer SINEAX U 55 in housing P/0 clipped onto a top-hat rail. he output amplifier transforms the measuring signal into an impressed DC current output signal A. he electronic components are supplied with voltage H from the mains supply unit H. U~ Ueff = o u dt A H Mode of operation Input signal U~ is galvanically separated from the mains network using a transformer. he following mathematical expression is then formed using a root-mean-square value computer Ueff = u dt o Following filtration by means of an active filter, the transformation properties of the measuring transducer are determined in the succeeding characteristics circuit. Fig.. Block diagram. echnical data General Measured quantity: Measuring principle: AC voltage Sine or distorted wave forme RMS value measurement Logarithmic method Camille Bauer Data sheet U 55 Le 0.0
Measuring input E Nominal frequency f N : Nominal input voltage U N (measuring range end value): Setting: 50/0 or 400 Hz 0 0 to 0 0 V Admissible alteration of full-scale output, variable sensitivity, adjustable with potentiometer Setting range 0.5.5 U N (± 5%) 00% U N Voltage limit under R ext = : Residual ripple in output current: Setting time: Power supply H 5 V 0.5% p.p. at setting time 00 ms % p.p. at setting time 50 ms 50 ms or 00 ms AC/DC power pack (DC or 40 400 Hz) able : Rated voltages and permissible variations Rated voltage olerancd 5 0 V DC / AC DC 5 + % 4 0 V DC / AC AC ± 5% Own consumption: Overload capacity: Measured quantity U N Number of applications 0Output 0 Input 0.5.5 VA with input end value Duration of one application Interval between two successive applications. U N continuously U N 0 s 0 s But max. 4 V with power supply from measuring input Measuring output A Load-independent DC current: Burden voltage: 0 to 0 0 ma resp. live-zero 0. to 4 0 ma 5 V External resistance: R ext max. [kω] = 5 V Load-independent DC voltage: I AN [ma] I AN = Output current end value 0 to 0 0 V resp. live-zero 0. to 0 V External resistance: R ext [kω] U A [V] Current limit under overload: ma.5 I AN at current output Approx. 0 ma at voltage output Option: Power consumption: Accuracy (acc. to EN 0 ) Reference value: Connected to the low tension terminal side and 4 V AC or 4 0 V DC.5 W resp. VA Output end value Basic accuracy: Class 0.5 Reference conditions: Ambient temperature 5 0 C Input variable Frequency Curve shape Crest factor Power supply Output burden Warm-up time Influence effects (maxima): included in basic error Rated operating range f N ± Hz Sine-wave In rated range Current: 0.5 R ext max. Voltage: R ext min. 5 min. Frequency 40 400 Hz, ± 0.% 0 000 Hz, ± 0.5% Crest factor.5 ± 0.% >.5 ± 0.5% Safety Protection class: II (protection isolated, EN 00) Housing protection: Contamination level: Overvoltage category: IP 40, housing (test wire, EN 0 5) IP 0, terminals (test finger, EN 0 5) III Data sheet U 55 Le 0.0 Camille Bauer
Rated insulation voltage (versus earth): 400 V, input 0 V, power supply 40 V, output est voltage: 50 Hz, min. acc. to EN 00- Installation data Mechanical design: Housing P/0 Material of housing: Mounting: Mounting position: Weight: Connecting terminals Connection element: Permissible cross section of the connection leads: 00 resp. 5550 V, input versus all other circuits as well as outer surface 00 V, power supply versus output as well as outer surface 40 V, output versus outer surface Lexan 40 (polycarbonate), flammability Class V-0 acc. to UL 4, self-extinguishing, non-dripping, free of halogen For rail mounting Any Approx. 0. kg Screw-type terminals with indirect wire pressure 4.0 mm single wire or.5 mm fine wire Environmental conditions Operating temperature: 0 to + 55 C Storage temperature: 40 to + 0 C Relative humidity of annual mean: 5% Altitude: Indoor use statement! Ambient tests EN 0 0--: Acceleration: Frequency range: Number of cycles: EN 0 0--: Acceleration: EN 0 0--/-/-: IEC 000-4-/-/-4/-5/- EN 55 0: Germanischer Lloyd ype approval certificate: Ambient category: Vibrations: 000 m max. Vibration ± g 0 50 0 Hz, rate of frequency sweep: octave/minute 0, in each of the three axes Shock 50 g shocks each in directions Cold, dry heat, damp heat Electromagnetic compatibility No. 5- HH C 0. g able : Specification and ordering information Designation *Blocking No-go with Article No./ code blocking code Feature SINEAX U 55 Order Code 55 - xxxx xx 55 Features, Selection. Mechanical design Housing P/0 for rail mounting 4. Nominal input frequency 50/0 Hz 400 Hz Continuation see on next page! Camille Bauer Data sheet U 55 Le 0.0
Designation *Blocking No-go with Article No./ code blocking code Feature SINEAX U 55 Order Code 55 - xxxx xx 55 Features, Selection. Measuring range 0 00 / A A 0 0 / A B 0 00 B C 0 0 B D 0. B E 0 0 B F 0 5 B G 0. B H 0 50 B J 0 50 C K 0 500* C L Non-standard [V] Z 0 0 to 0 0 V With power supply from measuring input min. 4 V / max. 0 V, see feature 5, lines and 4. * Max. 400 V nominal value of the network against earth (operating voltage acc. to EN 00) 4. Output signal 0 0 ma, R ext 50 Ω 4 0 ma, R ext 50 Ω Non-standard [ma] 0.00 to 0 < 0 0. to < (4 0) 0 0 V, R ext 5 kω A Non-standard [V] Z 0.00 to 0 < 0 0. to 0 5. Power supply 5 0 V DC / AC 4 0 V DC / AC From measuring input 4 0 V AC BC From measuring input 5 0 V AC AC 4 Connected to the low tension terminal side and 5 4 V AC / 4 0 V DC. Setting time 0. s 50 ms *Lines with letter(s) under no-go cannot be combined with preceding lines having the same letter under Blocking code. 4 Data sheet U 55 Le 0.0 Camille Bauer
Electrical connections 0 0 ( )(+) 0 U ( )(+) U Fig.. Power supply connected to terminals and. Fig. 4. Power supply internal from measuring input, without separated power supply connected. U Fig. 5. Power supply connected to the low tension terminal side and. = Measuring input = Measuring output = Power supply Dimensional drawing,5 0, 4, 0 Fig.. SINEAX U 55 in housing P/0 clipped onto a top-hat rail (5 5 mm or 5.5 mm, acc. to EN 50 0). Rely on us. Standard accessories Operating Instructions in three languages: German, French, English Camille Bauer AG Aargauerstrasse CH-50 Wohlen / Switzerland Phone: + Fax: + 5 5 e-mail: info@camillebauer.com www.camillebauer.com Subject to change without notice Edition 0.0 Data sheet U 55 Le