ACOUSTIC MITIGATION STATUS FOR S3

Similar documents
ACOUSTIC MITIGATION POST-S3 UPDATE

Improving seismic isolation in Advanced LIGO using a ground rotation sensor

Results from the Stanford 10 m Sagnac interferometer

Understanding Initial LIGO and Possible Influences on Enhanced LIGO. Sam Waldman and Rai Weiss February 2008

External seismic pre-isolation retrofit design

A Study of Vibrating Objects using Time-Average Holographic Interferometry

Strong Motion Data: Structures

Control Servo Design for Inverted Pendulum

An Alternative to Pyrotechnic Testing For Shock Identification

Periodic Error Correction in Heterodyne Interferometry

Period 3 Solutions: Electromagnetic Waves Radiant Energy II

Impact sound insulation: Transient power input from the rubber ball on locally reacting mass-spring systems

Seismic Noise & Vibration Isolation Systems. AIGO Summer Workshop School of Physics, UWA Feb Mar. 2, 2010

Chapter 7. Optical Measurement and Interferometry

Length and Position Measurement

The X-arm interferometer test of HEPI at LIGO Livingston

On the Influence of the Junctions on Wooden Buildings Structural-Acoustic Behaviour

la. Smith and C.P. Burger Department of Mechanical Engineering Texas A&M University College Station Tx

INTERFEROMETRIC VIBRATION DISPLACEMENT MEASUREMENT

Mechanical modeling of the Seismic Attenuation System for AdLIGO

Active Control of Energy Density in a Mock Cabin

Single Frequency Laser/Single Longitudinal Mode Laser

Investigating Electromagnetic and Acoustic Properties of Loudspeakers Using Phase Sensitive Equipment

Fumiaki UEHAN, Dr.. Eng. Senior Researcher, Structural Mechanics Laboratory, Railway Dynamics Div.

430. The Research System for Vibration Analysis in Domestic Installation Pipes

A study of Savitzky-Golay filters for derivatives in primary shock calibration

High Sensitivity Interferometric Detection of Partial Discharges for High Power Transformer Applications

Attenuation of low frequency underwater noise using arrays of air-filled resonators

LIQUID SLOSHING IN FLEXIBLE CONTAINERS, PART 1: TUNING CONTAINER FLEXIBILITY FOR SLOSHING CONTROL

Module 5: Experimental Modal Analysis for SHM Lecture 36: Laser doppler vibrometry. The Lecture Contains: Laser Doppler Vibrometry

Interferometer signal detection system for the VIRGO experiment. VIRGO collaboration

Wavelength Control and Locking with Sub-MHz Precision

LOS 1 LASER OPTICS SET

Fig m Telescope

3D Optical Motion Analysis of Micro Systems. Heinrich Steger, Polytec GmbH, Waldbronn

Linguistics 401 LECTURE #2. BASIC ACOUSTIC CONCEPTS (A review)

SmartSenseCom Introduces Next Generation Seismic Sensor Systems

Suppression of Stimulated Brillouin Scattering

Astra Microwave Products Ltd. Environmental, EMI/EMC Test Facilities & Laser Welding

Vertical-Vibration Suppressing Design of Accumulator with New Vibration-Measuring Method

DRAFT Expected performance of type-bp SAS in bkagra

The Virgo detector. L. Rolland LAPP-Annecy GraSPA summer school L. Rolland GraSPA2013 Annecy le Vieux

Commissioning of Advanced Virgo

Texas Components - Data Sheet. The TX53G1 is an extremely rugged, low distortion, wide dynamic range sensor. suspending Fluid.

Development of Random Vibration Profiles for Test Deployers to Simulate the Dynamic Environment in the Poly-Picosatellite Orbital Deployer

SECTION A Waves and Sound

How to Build a Gravitational Wave Detector. Sean Leavey

Back-Reflected Light and the Reduction of Nonreciprocal Phase Noise in the Fiber Back-Link on LISA

CHAPTER 3 THE DESIGN OF TRANSMISSION LOSS SUITE AND EXPERIMENTAL DETAILS

SETUP I: CORD. Continuous Systems

Speckle Mitigation in Laser-Based Projectors

Introduction. Learning Objectives. On completion of this class you will be able to. 1. Define fiber sensor. 2. List the different types fiber sensors

Operation manual. Model 24 Infrasound Sensor

Continuous Wave (CW) Single-Frequency IR Laser NPRO 125/126 Series

Natural Frequencies and Resonance

1241. Efficiency improvement of energy harvester at higher frequencies

Systems. Dynamic Test. Electrodynamic Vibration Test Systems

Development of the accelerometer for cryogenic experiments II

DEMONSTRATIONS Spring 2008 WEEK# MON FRI WED FRI FEB 6 FEB 1 C35 C2 C5 C2 C5 L1 C12 FRI. Registration Day FEB 4 FEB 1

An acousto-electromagnetic sensor for locating land mines

Vibration studies of a superconducting accelerating

Installation and Characterization of the Advanced LIGO 200 Watt PSL

Development of Shock Acceleration Calibration Machine in NMIJ

Measurements of Mode Converted ICRF Waves with Phase Contrast Imaging in Alcator C-Mod

PanPhonics Panels in Active Control of Sound

On the accuracy reciprocal and direct vibro-acoustic transfer-function measurements on vehicles for lower and medium frequencies

SECTION A Waves and Sound

Noise Budget Development for the LIGO 40 Meter Prototype

visibility values: 1) V1=0.5 2) V2=0.9 3) V3=0.99 b) In the three cases considered, what are the values of FSR (Free Spectral Range) and

Theory and Applications of Frequency Domain Laser Ultrasonics

A Narrow-Band Tunable Diode Laser System with Grating Feedback

Module 4 TEST SYSTEM Part 2. SHAKING TABLE CONTROLLER ASSOCIATED SOFTWARES Dr. J.C. QUEVAL, CEA/Saclay

Electromagnetic Spectrum

Very High Frequency Calibration of Laser Vibrometer up to 350 khz

Agilent 10705A Single Beam Interferometer and Agilent 10704A Retroreflector

HIGH POWER LASERS FOR 3 RD GENERATION GRAVITATIONAL WAVE DETECTORS

Stabilizing an Interferometric Delay with PI Control

Optical Phase Lock Loop (OPLL) with Tunable Frequency Offset for Distributed Optical Sensing Applications

An Experimental Evaluation of the Application of Smart Damping Materials for Reducing Structural Noise and Vibrations

Laser Doppler sensing in acoustic detection of buried landmines

Initial Results from the C-Mod Prototype Polarimeter/Interferometer

Seattle Q1 Infrasound Microphone

Multiply Resonant EOM for the LIGO 40-meter Interferometer

CALIBRATION OF LASER VIBROMETER STANDARDS ACCORDING TO ISO

Waves Mechanical vs. Electromagnetic Mechanical Electromagnetic Transverse vs. Longitudinal Behavior of Light

Absolute distance interferometer in LaserTracer geometry

Laboratory Experiment #2 Frequency Response Measurements

VIRGO. The status of VIRGO. & INFN - Sezione di Roma 1. 1 / 6/ 2004 Fulvio Ricci

INDIAN INSTITUTE OF TECHNOLOGY BOMBAY

Microscopic Laser Doppler Vibrometer

The Use of a Floating Threshold for Online Acoustic Emission Monitoring of Fossil High Energy Piping

Continuous-Wave (CW) Single-Frequency IR Laser. NPRO 125/126 Series

NINTH INTERNATIONAL CONGRESS ON SOUND AND VIBRATION, ICSV9 ACTIVE VIBRATION ISOLATION OF DIESEL ENGINES IN SHIPS

Plane Mirror Interferometer Configurations. Functional description. Interferometeranordnung Plane Mirror Interferometer

Doppler-Free Spetroscopy of Rubidium

Mystery noise in GEO600. Stefan Hild for the GEO600 team. 14th ILIAS WG1 meeting, October 2007, Hannover

The VIRGO injection system

LASER. Analog Laser Displacement Transducer. LAM Series. Key-Features: Content:

The VIRGO suspensions

LIGO II Photon Drive Conceptual Design

Transcription:

ACOUSTIC MITIGATION STATUS FOR S3 Robert Schofield, University of Oregon Doug Cook, Akiteru Takamori, Daniel Sigg, LHO Jonathan Kern, Joe Kovalik, LLO Peter Fritschel, Ken Mason, MIT AND MANY OTHERS

PROBLEM Red shows coherence between H1 and H2 AS_Q over 12h during S2 Coherence 0.3 0.25 H2:LSC-AS_Q / H1:LSC-AS_Q H0:PEM-BSC7_MIC / H2:LSC-AS_Q Coherence 0.2 0.15 0.1 0.05 0 0 100 200 300 400 500 600 700 800 900 T0=09/03/2003 02:15:00 Avg=400 BW=0.0117178 Blue shows coherence between microphone near 4k dark port and 2k AS_Q 2

At some frequencies, the sensitivities of all 3 interferometers were limited by acoustic coupling during S2. Power spectrum 10 3 10 2 10 H0:PEM-BSC7_MIC(REF0) H0:PEM-HAM1_MIC(REF1) H1:LSC-AS_Q(REF2) H0:PEM-BSC7_MIC(REF3) H0:PEM-HAM1_MIC(REF4) H1:LSC-AS_Q(REF5) Magnitude 1 10-1 10-2 10-3 10-4 10 2 10 3 *T0=12/03/2003 05:29:46 *Avg=1 BW=0.187499 Black: AS_Q with noise; Red: normal; Orange: mic with noise; Yellow: normal We would like to reduce acoustic-seismic contribution to noise by 100 to 1000 3

S2 INVESTIGATION OF ACOUSTIC COUPLING COUPLING SITES confirmed using propagation delays; if a sound shows up on AS_Q before it shows up on a certain mic, there is a coupling site between the sound source and the microphone. Localized injections showed that the coupling was at least 10x worse at the dark port tables than at other coupling sites. MAIN COUPLING MECHANISM was shown to be clipping modulated by acoustic excitation; experiments included manipulation of clipping with irises and experiments to asses backscattering. ACOUSTIC SOURCES: HVAC below 100 Hz, electronics cabinets above 100 Hz, and transients (e.g. building relaxation creeks), about as loud as continuous sources. 7 PROPAGATION FROM SOURCE TO COUPLING SITE; investigations with LLO PSL enclosure showed that acoustic isolation reduced motions on tables, indicating that propagation was mainly through the air. 4

MITIGATION PLANS (red indicates completed) I. REDUCE COUPLING (factor of 10 to 20) A. Clipping 1) Eliminate some clipping sites (e.g. EO shutter) 2) Larger optics where needed; lighter mounts for higher resonant frequencies 3) Damp mounts and dumps etc. 4) New periscopes with higher frequency resonances and damping 5) Reduce table resonances around 100 Hz B. Backscattering from table (out of prudence - we haven t seen coupling) 1) Rigid legs or float table II. ACOUSTICALLY ISOLATE WORST COUPLING SITES (factor of 10 to 20) A. Dark port enclosures with internal absorption kits III. REDUCE CONTINUOUS SOURCES (factor of 3 to 5) A. Remove most electronics cabinets from LVEA B. Absorption and damping kits for vacuum electronics cabinets C. Damp single walled sections of ducts D. Insulate pipe feed through from mechanical room E. Insulate PSL chillers 5

OPTICS UPGRADE SINCE S2 TO REDUCE MODULATED CLIPPING Dark and reflected ports on all three interferometers 1) Removed EO shutters and associated polarizers 2) Replaced several 1 optics with 2 optics 3) Replaced heavy optics mounts with light mounts 4) Simplified beam path Old Mount New Mount EO shutter removed

NEW PERISCOPE DESIGN WITH DAMPING Accelerometer on periscope top; Blue: no damping Red: damping Damping Power spectrum 10 2 H1:GDS-TEST_34_1_20(REF5) H1:GDS-TEST_34_1_20(REF8) Magnitude 10 1 100 200 300 400 500 600 700 800 900 *T0=01/08/2003 02:31:49Avg=1/Bin=8 BW=0.187499 7

AT MOST LOCATIONS WE ARE CURRENTLY USING OLD PERISCOPES WITH DAMPING Steel plate and damping foam attached to back of periscope Latest version of new periscope design should be compared to this modified periscope 8

TABLE LEG TESTING Compared 5 leg designs using the following figures of merit: 1) lower rms amplitude of table motion above 70 Hz (to reduce in-band modulation of clipping) 2) lower rms velocity (to reduce potential back-scattering noise - this is less important because we did not find back-scattering noise [next slide], and table motion amplitudes are less than 1/10 laser wavelength). current tall tripod small tripod (damped) pneumatic minus-k (spring)

No Evidence for Parasitic Interferometry Noise From Backscattering 10 4 10 3 10 2 H0:PEM-HAM4_ACCX(REF4) H1:LSC-AS_Q(REF7) H0:PEM-HAM4_ACCX(REF28) H1:LSC-AS_Q(REF31) Magnitude 10 1 10-1 10-2 10-3 10-4 10 2 *T0=21/05/2003 08:11:03 Avg=1 BW=0.187499 Red: Accelerometer on Dark Port Table Blue: AS_Q Solid: Normal; Dashed: Shaker shaking table at 14 Hz (sway resonance) 10

COMPARISON OF RIGID AND FLOATING TABLE LEGS ON ISCT3 Red: current leg; Orange: tall tripod; Blue: minus-k; Black: pneumatic 10-7 10-8 Rigid Legs normal leg 34" tripod leg Floating Legs minus-k leg air leg Displacement [m/hz 1/2 ] 10-9 10-10 10-11 10-12 10-13 10 2 3 4 5 6 7 8 9 100 2 3 4 5 6 7 8 9 Frequency [Hz] Sum in quadrature of 3 accelerometer axes, converted to displacement 11

TABLE LEG CONCLUSIONS 1) The rigid tripod legs have not proven to be substantially better than our current legs, either for rms velocity or rms amplitude above 70 Hz. However, we have not yet tried bonding the tripod legs to the floor. 2) The two sets of legs that float the table (pneumatic, minus-k spring) were comparable (pneumatic, slightly better) and resulted in a factor of about ten lower rms velocity and nearly a factor of ten lower rms amplitude above 70 Hz. We are installing the minus-k legs at ISCT3 to study drift of floating tables. 12

DARK PORT ENCLOSURES WITH ABSORPTION KITS Installed ISCT4 enclosure is giving a factor of about 20 above 100 Hz; red: before; blue: after 10 3 ISCT4_MIC_B4-enclosure H0:PEM-ISCT4_MIC Magnitude 10 2 10 1 10 2 10 3

MITIGATION OF CONTINUOUS SOURCES: Damped visibly vibrating sections of single walled ducts at LHO. Completed just before S3, so havent had a chance to test completely, but looks like, at most, a factor of 2 reduction in LVEA levels around 100 Hz. 14

Plan to remove 4k electronics cabinets from LVEA, place 2k cabinets in acoustic enclosures, internal absorption for vacuum cabinets and PSL chiller enclosures. 15

REDUCTION IN ACOUSTIC COUPLING SINCE S2 Red: AS_Q normal; Black: AS_Q with noise; Yellow & Orange: BSC7 mic March 12: S2 m/sqrt(hz) 10 10-12 10-13 10-14 10-15 10-16 10-17 10-18 10-19 H0:PEM-BSC7_MIC(REF0) H0:PEM-HAM1_MIC(REF1) H1:LSC-AS_Q(REF2) H0:PEM-BSC7_MIC(REF3) H0:PEM-HAM1_MIC(REF4) H1:LSC-AS_Q(REF5) *T0=12/03/2003 05:29:46 *Avg=1 BW=0.187499 August 9: EO shutter out, periscope mount replaced ) 1/2 Magnitude (m/hz 10-11 10-12 10-13 10-14 10-15 10-16 10-17 10-18 10-19 H1:LSC-AS_Q(REF35) H1:LSC-AS_Q(REF39) H0:PEM-BSC7_MIC(REF38) H0:PEM-BSC7_MIC(REF42) H0:PEM-HAM1_MIC(REF36) H0:PEM-HAM1_MIC(REF40) 10 2 10 3 10 2 10 3 *T0=09/08/2003 04:10:03 Avg=1 BW=0.187499

Sept 13: after enclosure, 2 inch optics; Blue: injection at REFL port (now limiting) Oct 4: after REFL port work - removal of EO shutter, 2 optics, damped periscope ) 1/2 10-11 10-12 10-13 H1:LSC-AS_Q(REF21) H1:LSC-AS_Q(REF27) H1:LSC-AS_Q(REF29) H0:PEM-BSC7_MIC(REF89) H0:PEM-BSC7_MIC(REF30) Magnitude (m/hz 10-14 10-15 10-16 10-17 10-18 10-19 10 2 10 3 *T0=04/10/2003 07:05:07 Avg=1 BW=0.187499

Red shows coherence between H1 and H2 AS_Q over about 12h Blue shows coherence between microphone near 4k dark port and 2k AS_Q S2: 0.3 0.25 H2:LSC-AS_Q / H1:LSC-AS_Q H0:PEM-BSC7_MIC / H2:LSC-AS_Q Coherence 0.2 0.15 0.1 0.05 S3: 0 0 100 200 300 400 500 600 700 800 900 T0 09/03/2003 02 15 00 A 400 BW 0 0117178 0.3 0.25 H2:LSC-AS_Q / H1:LSC-AS_Q H0:PEM-BSC7_MIC / H2:LSC-AS_Q H0:PEM-BSC7_MIC / H1:LSC-AS_Q Coherence 0.2 0.15 0.1 0.05 0 0 100 200 300 400 500 600 700 800 900 T0=08/11/2003 06:30:00 Avg=400/Bin=11 BW=0.0117178

PEM UPGRADE IS PUTTING MICROPHONES AND ACCELEROMETERS ON ALL TABLES Microphone on ISCT1, (the worst 4k coupling site) indicates that we have to increase the ambient sound level by a factor of about 100 to produce acoustic peaks reaching 10-17 m/ sqrt(hz), suggesting that ambient levels will produce peaks reaching 10-19 m/sqrt(hz). CONCLUSIONS: 1) WE HAVE REDUCED H1 ACOUSTIC COUPLING BY A FACTOR OF OVER 100 SINCE S2 2) AMBIENT SOUND LEVELS ON H1 NOW LIMITING AT ABOUT 10-19 m/sqrt(hz) AT 200 Hz 3) A LITTLE LESS THAN A FACTOR OF TEN TO GO TO REACH DESIRED INSENSITIVITY 4)FURTHER IMPROVEMENTS WILL NOT BE VISIBLE IN TYPICAL SPECTRA 5) MAKING SURE THESE BENEFITS ARE FULLY EXTENDED TO H2 AND L1 18