Point Spread Function Estimation Tool, Alpha Version. A Plugin for ImageJ

Similar documents
ECEN 4606, UNDERGRADUATE OPTICS LAB

Leica DMi8A Quick Guide

Supplemental Figure 1: Histogram of 63x Objective Lens z axis Calculated Resolutions. Results from the MetroloJ z axis fits for 5 beads from each

Camera Test Protocol. Introduction TABLE OF CONTENTS. Camera Test Protocol Technical Note Technical Note

Nikon. King s College London. Imaging Centre. N-SIM guide NIKON IMAGING KING S COLLEGE LONDON

Training Guide for Leica SP8 Confocal/Multiphoton Microscope

Spatial intensity distribution analysis Matlab user guide

User manual for Olympus SD-OSR spinning disk confocal microscope

Optical Performance of Nikon F-Mount Lenses. Landon Carter May 11, Measurement and Instrumentation

MRI Grid. The MRI Grid is a tool in MRI Cell Image Analyzer, that can be used to associate measurements with labeled positions on a board.

Zeiss LSM 510 Confocor III Training Notes. Center for Cell Analysis & Modeling

Biology 29 Cell Structure and Function Spring, 2009 Springer LABORATORY 1: THE LIGHT MICROSCOPE

Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center

The Zeiss AiryScan System, Confocal Four.

Bi/BE 227 Winter Assignment #3. Adding the third dimension: 3D Confocal Imaging

ScanArray Overview. Principle of Operation. Instrument Components

Training Guide for Carl Zeiss LSM 510 META Confocal Microscope

GXCapture 8.1 Instruction Manual

Point Spread Function. Confocal Laser Scanning Microscopy. Confocal Aperture. Optical aberrations. Alternative Scanning Microscopy

3D light microscopy techniques

Topic 04 What is a digital image?

Introduction to BioImage Analysis

What is a digital image?

Training Guide for Carl Zeiss LSM 5 LIVE Confocal Microscope

Manual. Cell Border Tracker. Jochen Seebach Institut für Anatomie und Vaskuläre Biologie, WWU Münster

Be aware that there is no universal notation for the various quantities.

LSM 780 Confocal Microscope Standard Operation Protocol

Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center

Nature Protocols: doi: /nprot Supplementary Figure 1. Schematic diagram of Kőhler illumination.

1 Co Localization and Working flow with the lsm700

CHAPTER1: QUICK START...3 CAMERA INSTALLATION... 3 SOFTWARE AND DRIVER INSTALLATION... 3 START TCAPTURE...4 TCAPTURE PARAMETER SETTINGS... 5 CHAPTER2:

Overview. About other software. Administrator password. 58. UltraVIEW VoX Getting Started Guide

FLUORESCENCE MICROSCOPY. Matyas Molnar and Dirk Pacholsky

Introduction to BioImage Analysis using Fiji

Examination, TEN1, in courses SK2500/SK2501, Physics of Biomedical Microscopy,

Renishaw InVia Raman microscope

User Manual. Copyright 2010 Lumos. All rights reserved

LSM 800 Confocal Microscope Standard Operation Protocol

3D light microscopy techniques

Education in Microscopy and Digital Imaging

LSM 510 Meta Training Notes

Katarina Logg, Kristofer Bodvard, Mikael Käll. Dept. of Applied Physics. 12 September Optical Microscopy. Supervisor s signature:...

Swept-Field User Guide

Diffraction at Circular Edges

LSM 510 Training Notes

LSM 710 Confocal Microscope Standard Operation Protocol

Boulevard du Temple Daguerrotype (Paris,1838) a busy street? Nyquist sampling for movement

Things to check before start-up.

Title: Leica SP5 Confocal User Manual

Practical work no. 3: Confocal Live Cell Microscopy

Single Photon Interference Katelynn Sharma and Garrett West University of Rochester, Institute of Optics, 275 Hutchison Rd. Rochester, NY 14627

Bioimage Informatics

Multicolor 4D Fluorescence Microscopy using Ultrathin Bessel Light sheets

AgilEye Manual Version 2.0 February 28, 2007

STORM/ PALM ANSWER KEY

MICROSCOPY MICROSCOPE TERMINOLOGY

Match the microscope structures given in the left column with the statements in the right column that identify or describe them.

Zeiss Axiovert 135 Fluorescence Microscope Quick Guide / Operations Manual (v. 1.0 February 09)

Microscope anatomy, image formation and resolution

Widefield 1. Switching on

User Guide for TWAIN / DirectX interface for GRYPHAX USB 3.0 cameras

Measurement of the Modulation Transfer Function (MTF) of a camera lens. Laboratoire d Enseignement Expérimental (LEnsE)

Modulation Transfer Function

Science in the Classroom. Actin Network Architecture can determine Myosin Motor Activity Student Activity

CAPTURING IMAGES ON THE HIGH-MAGNIFICATION MICROSCOPE

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

Optika ISview. Image acquisition and processing software. Instruction Manual

Ph 3455 The Photoelectric Effect

Applications of Optics

Light Microscopy. Upon completion of this lecture, the student should be able to:

Horiba LabRAM ARAMIS Raman Spectrometer Revision /28/2016 Page 1 of 11. Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer

Nikon Instruments Europe

PHY385H1F Introductory Optics. Practicals Session 7 Studying for Test 2

Microscopy. CS/CME/BioE/Biophys/BMI 279 Nov. 2, 2017 Ron Dror

Digital Camera Technologies for Scientific Bio-Imaging. Part 2: Sampling and Signal

Training Guide for Carl Zeiss LSM 880 with AiryScan FAST

Supplementary Figure S1: Schematic view of the confocal laser scanning STED microscope used for STED-RICS. For a detailed description of our

Cell Biology and Bioimaging Core

VISUAL PHYSICS ONLINE DEPTH STUDY: ELECTRON MICROSCOPES

Topics. - How to calibrate the LSM scanner. - How to clean the microscope. - How to adjust the pinhole alignment. - How to adjust the Collimator

New Features in Release 2.2

Introduction to light microscopy

INTRODUCTION TO CCD IMAGING

Focus on an optical blind spot A closer look at lenses and the basics of CCTV optical performances,

Zeiss 880 Training Notes Zen 2.3

OPTICAL SYSTEMS OBJECTIVES

Bringing Answers to the Surface

Assignment 1 Examining the Solar Spectrum with a diffraction grating

Zeiss 780 Training Notes

CCAM Microscope Objectives

You won t be able to measure the incident power precisely. The readout of the power would be lower than the real incident power.

Signal-to-Noise Ratio (SNR) discussion

Optical design of a high resolution vision lens

Olympus Digital Microscope Camera (DP70) checklist

Zeiss LSM 880 Protocol

Standard Operating Procedure (SOP) for Shared Equipment: Spinning Disk Confocal Microscope

Application Note #548 AcuityXR Technology Significantly Enhances Lateral Resolution of White-Light Optical Profilers

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G

The microscope is useful in making observations and collecting data in scientific experiments. Microscopy involves three basic concepts:

40 Digital Photo Retouching Techniques COPYRIGHTED MATERIAL

Transcription:

Tutorial Point Spread Function Estimation Tool, Alpha Version A Plugin for ImageJ Benedikt Baumgartner Jo Helmuth jo.helmuth@inf.ethz.ch MOSAIC Lab, ETH Zurich www.mosaic.ethz.ch

This tutorial explains the use of the Point Spread Function Estimation Tool, implemented as a plugin for ImageJ. The plugin is still under active development. Your comments on functionality, design, and bugs are highly appreciated. 1 General Description Your microscope setup constitutes an expensive and precious resource from which you want to get the best possible performance. Therefore, you should not rely on purely qualitative performance metrics like it looks pretty good. Your eyes are not capable of telling the difference between a well-adjusted microscope and a poorly adjusted one. In all real equipment, the imaging results are worse than the theoretically possible value (e.g. by a factor of 1.5 in resolution). The reasons for this include imaging noise (prefer images with long exposure!), imperfections of the lenses, distortions caused by variations in cover slide thickness (your objectives are corrected for a specific thickness of slides and they are very sensitive to this), the finite width of the emission wavelength spectrum (we also collect some light at longer wavelengths), point sources of finite extension, under-sampling due to a mismatch of magnification and camera pixel size, and so on. Or you might simply not have focused well enough. D oh! Most likely, many people in your lab share the use of a microscope. You can thus benchmark your results against the ones of your colleges to get a first clue about the quality of your images. The present tool gives you a quantitative way of doing so, enables you to adjust your microscope optimally, and to compare your images to the maximum possible theoretical quality. This is done on the basis of the microscope s Point Spread Function (PSF). The PSF is widely used to describe the imaging properties of optical systems such as light microscopes. Most importantly, the shape of the PSF is a measure for the resolving power of the optical system. In a nutshell, the PSF is the smeared image of a point-like source. The present tool is intended to be used for characterizing light microscopes (of any kind, e.g. fluorescence, wide-field, confocal,...) equipped with a digital camera. With this tool you are able to estimate the PSF of a microscope setup and to compare it to the theoretical PSF as calculated from elementary parameters of the microscope and the camera. This serves two purposes: First, you might want to know whether you adjusted your equipment optimally, and second, the PSF can be used for image restoration purposes (in future versions of the plugin) such as deconvolution. 1

Presently, this tool features: user-defined parameters, free selection of images of point sources to be considered for PSF estimation, automatic source position refinement based on intensity centroid estimation, plots of the measured and the theoretical PSF, and a report file containing all relevant input and output. 2 Installation The plugin requires a working installation of ImageJ (version 1.36 or later) on your system. To install the plugin, simply drag the PSF Tool folder into the plugins folder of your local ImageJ installation. After restarting ImageJ, PSF Tool should be visible in the Plugins menu. 3 How to use the Plugin In the following, we will walk through an example in order to describe the main features of the tool and their usage. We have, therefore, attached a sample image to the zip-file, called sample.tif (courtesy of Christoph Burckhardt, Greber lab, University of Zurich). The image shows endosomes and small vesicles in a human cell. While these objects are not strictly point sources, they are still smaller than the resolution limit of the microscope (their size is about 100 nm). For real applications, we strongly encourage you to spend some time on imaging small sources of known size, such as fluorescent beads, virus particles, quantum dots, or whatever is available in your lab. The smaller and brighter the better. Also consider that the sources should not move during exposure. 3.1 Start and Configuration To start, open sample.tif in ImageJ. Currently, the plugin only handles 8-bit gray-scale images so we need to convert the Image. Select Image Type 8-bit in the menu. Now start the plugin. A configuration dialog will appear (see Figure 1). Here, you have to enter necessary microscope, camera, and image parameters on which the calculations will be based. 2

Figure 1: Configuration menu Radius of Point Sources (pixel) The apparent radius of the point sources in the image. The parameter is needed for position refinement. In our example, set it to 2. Maximum Sampling Radius (pixel) Determines the radius around the centroid up to which the PSF is sampled. It is important to not set it below the first minimum of the PSF. Be conservative and set it to 4 in our example (which is twice the value of the apparent radius used above). Pixel Size on Camera Chip (µm) Have a look at the data sheet of your microscope or camera. For the tutorial data this parameter is 16. Numerical Aperture of Microscope Objective For the sample image the NA is 1.3. Wavelength of detected light (nm) We imaged green fluorescent proteins and set the value to the emission maximum at 532 nm. Microscope Magnification Factor Overall microscope magnification factor. In our case 100. Click OK after you have entered all parameters. 3.2 Source Selection and PSF Estimation Once you have entered the configuration parameters, a GUI with 4 Buttons is displayed (see Figure 2). 3

Figure 2: Graphical User Interface (GUI) Start New Selection Starts a new selection of point sources. Once pressed, every click on the image will result in a PSF estimation (be careful!). Enhance Contrast Enhances Image Contrast by linearly re-scaling all pixel intensity values to the possible range from 0 to 255 using the following equation: (I min (I)) I enhanced = 255 (max (I) min (I)) This does not affect the PSF estimation and is only done to enhance image viewing. Estimate PSF Estimates the Point Spread Function from all selected sources. Create Report Creates a text file containing all relevant result data. Let us now select some single-point sources. To make the selection more convenient, first zoom in to a specific area of the image using the ImageJ Magnifying Glass cursor. Now click on Start New Selection and select some point sources in the image (make sure your cursor is set to single selection again after magnification!). Try to choose apparently small points (the less bright ones might be the smallest) outside noisy areas and without strong background variations and close neighboring sources. Also, make sure not to select spots that contain saturated pixels. This would render your PSF estimate meaningless! Each time you select a source, the position of the source is refined to sub-pixel accuracy (as described in I. F. Sbalzarini and P. Koumoutsakos. Feature Point Tracking and Trajectory Analysis for Video Imaging in Cell Biology, Journal of Structural Biology 151(2):182-195, 2005 ) and a plot will show the estimated PSF of the last selection (see Figure 3). Your selection is also added to the 4

Figure 3: Plot of Point Spread Function. The average intensity on concentric circles around the intensity centroid is plotted against the radius. program s GUI and highlighted in the image by a red dot (see Figure 4). Figure 4: Point Source Selection For each selection has its own checkbox in the GUI, stating the refined centroid position of the source and the width of the PSF at half maximum. Using these checkboxes you can select the sources that are to be considered for the overall PSF estimation. To calculate the average PSF click Estimate PSF. A new plot ap- 5

pears showing the average PSF. In addition, a theoretical PSF is calculated from the microscope and camera parameters. This allows you to compare the measurement with the theoretical curve. A good measure of comparison is the width at half maximum. The closer the measured PSF is to the theoretical one, the better the performance of your equipment. The theoretical PSF corresponds to the maximum possible resolution permitted by the laws of optics. It is computed from the wavelength λ of the detected light, the microscope s numerical aperture NA, and C defining the intensity value at r = 0. Using the Bessel function J 1 (z), the theoretical PSF is then given by (as described in Y. Iketaki et. al. Theoretical investigation of the point-spread function given by super-resolving fluorescence microscopy using two-color fluorescence dip spectroscopy, Optical Engineering 44(3), 2005 ): PSF (r) = C 2J 1 ( 2π λ NAr) 2π λ NAr Click on Create Report in order to save the PSF data and the configuration parameters to a text file for later use or reference. 2 4 Development and contact The present PSF tool is still under active development. It is currently limited to 2D-PSFs. If you are dealing with image z-stacks, you could either process them slice-by-slice to get an idea of z-resolution (I would not recommend this, however) or wait for a 3D version of our tool. Alternatively, you could make a maximum intensity projection using ImageJ s ZProjection function. Note, however, that you will now measure the effect of your optical system plus the projection! Please send comments, wishes, and reports to jo.helmuth@inf.ethz.ch or benedikt.baumgartner@inf.ethz.ch. 6