PULSE OXIMETRY MODULE TO IMPLEMENT IN TEAM MONITOR OF VITAL SIGNS

Similar documents
WRIST BAND PULSE OXIMETER

DEPARTMENT OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCE MASSACHUSETTS INSTITUTE OF TECHNOLOGY CAMBRIDGE, MASSACHUSETTS 02139

PHOTOPLETHYSMOGRAPHIC DETECTOR FOR PERIPHERAL PULSE REGISTRATION

Pulse Oximetry. Principles of oximetry

PHYSIOLOGICAL SIGNALS AND VEHICLE PARAMETERS MONITORING SYSTEM FOR EMERGENCY PATIENT TRANSPORTATION

Laboratory Activities Handbook

ELR 4202C Project: Finger Pulse Display Module

Medical Electronics Dr. Neil Townsend Michaelmas Term 2001 ( Pulse Oximetry: The story so far

Design of Wearable Pulse Oximeter Sensor Module for Capturing PPG Signals

Low-cost photoplethysmograph solutions using the Raspberry Pi

City, University of London Institutional Repository

Principle of Pulse Oximeter. SpO2 = HbO2/ (HbO2+ Hb)*100% (1)

9 Feedback and Control

Design and Implementation of Digital Stethoscope using TFT Module and Matlab Visualisation Tool

E-health Project Examination: Introduction of an Applicable Pulse Oximeter

LOW POWER WIRELESS PULSE OXIMETER TERMINAL

The OXY100C outputs four signals simultaneously, as shown in this graph: O 2 Saturation (beat-by-beat, CH 1) Pulse Waveform (beat-by-beat, CH 5)

LABORATORY EXPERIMENT. Infrared Transmitter/Receiver

An Advanced Architecture & Instrumentation for Developing the System of Monitoring a Vital Sign (Oxygen Saturation) of a Patient.

Massachusetts Institute of Technology MIT

Design & Implementation of Pulseoxymeter to Measures the Oxygen Saturation in Blood

6.111 Final Project Proposal HeartAware

Class #9: Experiment Diodes Part II: LEDs

BENG 186B Principles of Bioinstrumentation. Week 7 Review. Solutions

SFH Photoplethysmography Sensor

DESIGN AND PROTOTYPING OF A MINIATURIZED SENSOR

AN2944 Application note

DESIGN OF AN ANALOG FIBER OPTIC TRANSMISSION SYSTEM

Quad Rat Vitals Monitor. Client: Dr. Alex Converse. Advisor: Dr. Tom Yen. Group Members: Jack Ho Team Leader. Nathan Werbeckes Communicator

Bend Sensor Technology Electronic Interface Design Guide

HIGH LOW Astable multivibrators HIGH LOW 1:1

Pulse Oximetry Dave Hoff Roy Zhang Tad Stalter Mike Carlson

Blood Group Detection and Mobile Monitoring System

DESIGN OF A PHOTOPLETHYSMOGRAPHY BASED PULSE RATE DETECTOR

Exam Booklet. Pulse Circuits

An Ultra-Low-Power Pulse Oximeter Implemented With an Energy-Efficient Transimpedance Amplifier

D5.1 Report on the design of a fibre sensor based on NIRS

City, University of London Institutional Repository

ASTABLE MULTIVIBRATOR

Project 1 Final System Design and Performance Report. Class D Amplifier

Noninvasive PoC Anemia Detection Device

Masimo Corporation 40 Parker Irvine, California Tel Fax

EXPERIMENT 2.2 NON-LINEAR OP-AMP CIRCUITS

REMOTE HEALTH MONITORING SYSTEM USING PIC MICROCONTROLLER

Optical Modulation and Frequency of Operation

CHAPTER IV DESIGN AND ANALYSIS OF VARIOUS PWM TECHNIQUES FOR BUCK BOOST CONVERTER

Difference between BJTs and FETs. Junction Field Effect Transistors (JFET)

PESIT BANGALORE SOUTH CAMPUS BASIC ELECTRONICS

Chapter 10 Adaptive Delta Demodulator

Touchless Control: Hand Motion Triggered Light Timer

PAiA 4780 Twelve Stage Analog Sequencer Design Analysis Originally published 1974

LINEAR IC APPLICATIONS

DESIGN A MEDICINE DEVICE FOR BLOOD OXYGEN CONCENTRATION AND HEART BEAT RATE

Electronic Instrumentation. Experiment 8: Diodes (continued) Project 4: Optical Communications Link

Introduction to IC-555. Compiled By: Chanakya Bhatt EE, IT-NU

T6+ Analog I/O Section. Installation booklet for part numbers: 5/4-80A-115 5/4-90A-115 5/4-80A /4-90A-1224

Control of Electrical Lights and Fans using TV Remote

DIGITAL ELECTRONICS: LOGIC AND CLOCKS

Quad Rat Vitals Monitor

Development of an Optical Heart Rate Monitor using a Microchip PIC24-microcontroller based development board

Advanced Regulating Pulse Width Modulators

Electronic Concepts and Troubleshooting 101. Experiment 1

About the Tutorial. Audience. Prerequisites. Copyright & Disclaimer. Linear Integrated Circuits Applications

1. LINEAR WAVE SHAPING

Infrared Communications Lab

High Current MOSFET Toggle Switch with Debounced Push Button

For the op amp circuit above, how is the output voltage related to the input voltage? = 20 k R 2

Noninvasive PoC Anemia Detection Device

Project 3 Build a 555-Timer

3 Circuit Theory. 3.2 Balanced Gain Stage (BGS) Input to the amplifier is balanced. The shield is isolated

HIGH FREQUENCY WAVEFORM GENERATOR. Author: Carlos Rodríguez Hernández

Design of a Low-cost Pulse Oximeter

Multivibrators. Department of Electrical & Electronics Engineering, Amrita School of Engineering

Pulse Sensor Individual Progress Report

Health and Fitness Analog solution. Wenbin Zhu Medical BDM June, 2015

Capacitive Touch Sensing Tone Generator. Corey Cleveland and Eric Ponce

PreLab 6 PWM Design for H-bridge Driver (due Oct 23)

Signal Extraction Technology

Dimensions in inches (mm) .268 (6.81).255 (6.48) .390 (9.91).379 (9.63) .045 (1.14).030 (.76) 4 Typ. Figure 1. Typical application circuit.

Special-Purpose Operational Amplifier Circuits

Heart-Rate Monitoring Control System Using Photoplethysmography (PPG)

(51) Int Cl.: A61B 5/00 ( ) G06F 17/00 ( )

Speed Control of DC Motor Using Phase-Locked Loop

Photoplethysmography device based on Galileo

GOVERNMENT OF KARNATAKA KARNATAKA STATE PRE-UNIVERSITY EDUCATION EXAMINATION BOARD II YEAR PUC EXAMINATION JULY-2012 SCHEME OF VALUATION

P.O. Pro WIRELESS REFLECTANCE PULSE OXIMETER Design 2. December 1, 2004 Team # 3 James Hart Sofia Iddir Rob Mahar Naomi Thonakkaraparayil

ECE 317 Laboratory #1 Force Sensitive Resistors

Wireless Sensor Networks. EP2980

Q1. Explain the Astable Operation of multivibrator using 555 Timer IC.

MP V, 1.2A, 1.4MHz White LED Driver Buck/Boost Halogen Replacement

ECONOMICAL HEART RATE MEASUREMENT DEVICE WITH REMOTE MONITORING USING FINGERTIP

the reactance of the capacitor, 1/2πfC, is equal to the resistance at a frequency of 4 to 5 khz.

B.E. SEMESTER III (ELECTRICAL) SUBJECT CODE: X30902 Subject Name: Analog & Digital Electronics

BME/ISE 3512 Bioelectronics. Laboratory Five - Operational Amplifiers

INTEGRATED PHOTODIODE AND AMPLIFIER

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Industrial Electronics

ENGR-4300 Fall 2006 Project 3 Project 3 Build a 555-Timer

Embedded based Wireless Healthcare Monitoring Vivek S. Metange 1 Prof. J. J. Chopade 2

HUMAN BODY MONITORING SYSTEM USING WSN WITH GSM AND GPS

ULTRASONIC TRANSMITTER & RECEIVER

Transcription:

PULSE OXIMETRY MODULE TO IMPLEMENT IN TEAM MONITOR OF VITAL SIGNS A. Soto Otalora 1, L. A. Guzman Trujilloy 2 and A. DiazDiaz 3 1 Industrial Control Engineering, Universidad Surcolombiana Neiva, Avenida Pastrana Carrera 2 Industrial Control Engineering, Facultad de Ingeniería Electrónica y Biomédica, Universidad Antonio Nariño, Neiva, Colombia 3 Electronic Engineering, Universidad Surcolombiana Neiva, Avenida Pastrana Carrera E-Mail: agussoto@usco.edu.co ABSTRACT This article presents meticulous description of a pulse oximetry module. This module allows to measure two variables: the saturation of oxygen in the hemoglobin of the blood and heart rate. The measurement is made through a sensor which contains two LEDs that emit red and infrared light which pass through the patient's finger to a photodetector, which measures the absorbance of each wavelength caused by arterial blood. The microcontroller calculates the percentage of oxygen saturation by the ratio of the absorbance of the red and infrared light. The pulse oximeterplethysmographic sensor wave whose period corresponds to the heartbeat is also obtained. These two facts together with the other variables are shown in a GLCD screen 240x128 pixels. Keywords: pulse oximetry, heart rate. 1. INTRODUCTION Pulse oximetry is a noninvasive method to measure the amount of oxygen from hemoglobin in the blood, besides obtaining plethysmographic waveform and with it to calculate the heart rate. In this technique, the clamp pulse oximeter is placed in a body part that is relatively translucent and has a good blood flow, such as fingers, toes, or the earlobe. The pulse oximeter clip has two LEDs that emit lights with different wavelengths, red and infrared light which pass to a photodetector (photodiode) through the patient. The absorbance of each wavelength caused by the arterial blood (pulse component) data with which it is possible to calculate the saturation of oxygen in blood is measured. To calculate% SPO2 is necessary to process the signal output from the photodiode. Since the signal current is given, it is necessary to convert it to a voltage signal. The power LEDs is intermittent and the output signal will be too, that is why it is necessary to have a sampler-holder circuit (sample and hold) that allows to reconstruct the signal and separate them into two red and infrared components. The two resulting signals are filtered separately with cutoff frequencies of 0.33 Hz and 5.89 Hz and obtaining two plethysmographic waves, one for red and one for infrared which are amplified and inverted for proper display on GLCD screen. Finally, to calculate the heart rate a plethysmographicwave red component is used, and an operational amplifier as crossing detector is set, so as to generate a train of digital pulses which can be easily read by the MSP430F2416 microcontroller [1] [2]. 2. METHODOLOGY Figure-1 shows the block diagram of the implemented pulse oximeter. Figure-1. Block diagram of the pulse oximeter. 1631

2.1 Current to voltage converter In Figure-2 are shown two operational amplifiers. The first stage consists of a high gain amplifier, being the output voltage equal to: Figure-2. Current to voltage converter. Where is the current delivered by the photodiode and will range from 0 to 50 ua. Worth noting, in the resistance value (3.9MΩ) the operational amplifier is not saturated, that is, the photodiode output current does not exceed at least 1.4uA. The 47pF capacitor forms a low-pass filter which reduces errors to possible instabilities caused by unwanted signals such as ambient light filter. The second stage of the amplifier AD712 has a voltage follower configuration, which aims to ensure no voltage drop at the moment retainers integrated circuit (sample and hold) is connected. 2.2 Sample and hold circuit The aim of the circuit shown in Figure-3 is to reconstruct the plethysmographic signal as the red and infrared diodes are energized each with two pulse signals of 1 khz, amplitude 12 volts, 10% duty cycle and 90 offset. Thus, the diodes emit light intermittently and with high current to ensure that the photodiode detects the pulsatingplethysmograph wave. The LF398 receive the signal from current to voltage converter, the sampling times are synchronized to the timer circuit, in order to properly convert the plethysmographic signal to pulsating DC. As time signal acquisition is less than 10us, a 0.1uF capacitor will be enough to keep the signal without information loss. For impedance matching, for each LF398 output a voltage follower is connected. [3] Figure-3. sampler circuit retainer. 2.3 Bandpass filter The post-amplifier in the voltage follower configuration is a filter which is shown in Figure-4. Figure-4. Band pass filter. As the plethysmographic signal is of very low frequency, as its maximum value is taken when the patient is a newborn baby, in which case the upper limit of the heart rate is 190 beats per minute (3.16Hz), becomes necessary implement a band-pass filter whose cutoff frequencies are: 1632

Moreover, this noise present in the electrical network and the switching of the LED is eliminated. 2.4 Adequacy of the plethysmographic signal For the plethysmographic waveform to be displayed on the GLCD screen appropriately, the circuit of Figure-5 is presented for adecuation. Figure-5. Adaptation of the plethysmographic waveform. In the circuit in the above figure can be seen exiting the DC component of the low-pass filter (DC_red and DC_ired). This parameter is used to calculate the percentage of oxygen saturation (% SpO 2) below. Since the microcontroller cannot receive negative signals, a voltage divider is implemented which is the reference voltage (Vref = 3.3V) and will upload the DC level of the signal, ensuring that no negative voltages are present at the ADC inputs of the microcontroller. The zener diodes at the bottom of Figure-5 delimit the pulseoximetry signal from 0 to 3.6 volts. This is done in order to eliminate any positive or negative peak voltage that may damage the ADC of the microcontroller to the time to put your finger on the pulseoximeter clip. Due to the pulsed nature of the signal, the sensor will register a large DC signal representing the residual arterial blood, venous blood and tissue. On the other hand only a small portion of the detected signal (~ 1%), will be AC signal representing the arterial pulse and is calculated using the RMS value. The following expressions to calculate the percentage of oxygen saturation in the blood, by means of an algorithm designed in MSP430f2416 is displayed on the GLCD: Equation (2) is a linear calibration curve approximation which at values less than 70% are not accurate, however, no clinically values are below this value. 2.5 Timer circuit To avoid overloading the microcontroller interrupt, a single pin of this where the signal that switches the light emitting diode will be used. In Figure-6 you can see the signal coming from the microcontroller to be VP. This signal is 2 KHz and has a 10% duty cycle. (1) (2) 1633

Figure-6. Timer circuit. The flip-flop is in Figure-6, is set to toggle mode, that is, changes state when a rising transition at the CLK arrives. With this you can 'remove' the signal coming from the microcontroller into two signals with 90 degrees out of phase with the help of transistors that simulate logic gates AND and NOT, and are no more than a de-multiplexer two channels [4]. 2.6 Automatic gain control Figure-7. Automatic gain control. Figure-7 shows a circuit which allows automatic control of brightness of the LED diodes. It consists of a proportional error control. The DC_ired signal is subtracted with a DC signal of 3.3 volts fixed and operates as follows: When the clamp pulseoximeter is exposed to ambient light and do not have the finger placed, DC_iredrisesup to 3 volts, which makes the difference small enough that when amplifying it doesn t activate Q4 and Q2 transistors and therefore there is no current to D1 and D2 [5]. The gain of the amplifier in noninverting mode is given by: (3) 1634

By placing your finger on the pulse oximetertheclip DC_ired signal falls below 3 volts, presenting a considerable difference to amplify by 1,667 is sufficient to activate the transistors Q2 and Q4 and hence the illumination of red and infrared diodes. shown in Figure-5, whose gains are equal and is given by equation (4): (4) 2.7 Cardiac pulse Monitoring the patient's heart rate an operational amplifier is configured as crossing detector, where the input signal is the inverted red plethysmographic waveform, so that when the signal is at the lowest level, the amplifier becomes saturated and when it has passed for that level, the output signal changes state. Thus the PPM signal is a square wave whose period matches the patient's heart rhythm [4] [5]. Figure-10. Plethysmographic wave inverted. The second amplification stage of Figure-5 reverses the waveform of Figure-10 to be displayed correctly. This plethysmographic waveform is shown in Figure-11 on the GLCD display along with other variables surveyed. Figure-8. Heartbeat detector. 2.8 Display To show the oxygen percentage data saturation and heart rate along with other variables, it is used a GLCD LGM240128A; this is a monochrome screen with a dimension of 240x128 pixels. The screen can be seen in Figure-9. Figure-11. Viewing the plethysmographic waveform on GLCD. Figure-9. GLCD display. 3. RESULTS Figure-10 shows the inverted plethysmographic waveform resulting from the first stage amplification 4. CONCLUSIONS A system for real-time monitoring of oxygen saturation in the blood and the patient pulses per minute were successfully prepared. A period of adjustment and processing to calculate the patient's heart rate from pulseoximetry module is designed. The use of low noise amplifiers, provided an accurate and reliable measure in the case of processing the pulseoximetry signal thanks to its internal features. The implementation of a pulseoximetry module can be included in a neonatal incubator so it allows to 1635

centralize noninvasive monitoring vital parameters for a premature neonate. REFERENCES [1] Chan V. y Underwood. S. 2005. A Single-Chip Pulsoximeter Design Using the MSP430. [2] Monroy A. 2009. Oximetría de pulso en la altura. Consultado el 17 de Mayo de 2014. http://altitudchulec.blogspot.com/2009/02/oximetriade-pulso-en-la-altura.html [3] Noguerol C, M. J. y Seco G, A, 2008. Pulsioximetría. Consultado el 21 de Junio de 2014. http://www.fisterra.com/material/tecnicas/pulsioximet ria/pulsioximetria.pdf [4] Quintero M., C. y Losada T., O., 2012. Diseño e Implementación de un Prototipo de Incubadora Neonatal de Cuidados Intensivos con Controlador Difuso. p. 98. [5] Towsend Neil. 2001. Medical Electronics. 54p. Consultado el 20 de Junio de 2014. http://www.robots.ox.ac.uk/~neil/teaching/lectures/me d_elec/notes6.pdf 1636