C30 Series AC-DC Converter

Similar documents
FS10 Series AC-DC Converter Compact Case(Power tank)

DATASHEET & RELIABILITY DATA

SPS20 Series small size isolated DC/DC converters

SPS20 Series small size isolated DC/DC converters

SPS1R5-5 Series small size isolated DC/DC converters

80W Single Output Switching Power Supply

HRS50 Series 50W isolated DC/DC converters

60W 75W 80W 81.6W 81W 82.8W 81.9W 81.6W 81W

HEC-30/35LTA-33TDAA Rev A

HEC-100RTA-48QSCA Rev A1.0

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

240W Single Output Switching Power Supply SELV

SPS10-24 Series small size isolated DC/DC converters

HEC-35LTA-XXTSAA Rev A

MODEL CLG CLG CLG CLG CLG CLG CLG V 18 ~ 24V 20V 15 ~ 20V

IP65 IP67 264W 285W 300W W 321W 320.4W 321.3W 321.6W

HLG-320H-12 HLG-320H-15 HLG-320H-20 HLG-320H-24 HLG-320H-30 HLG-320H-36 HLG-320H-42 HLG-320H-48 12V

HEC-150RTN-48QSCA. A. Features. B. Description. C. Models. D. Electronic Specifications - Input Specifications

HEC-45LTN-45PFAS Rev A

VP ELECTRONIQUE MASSY - Tel:

SELV. 95 ~ 108% Constant current limiting, recovers automatically after fault condition is removed

AC/DC Converter LD20-26Bxx Series

E E E E E E E E E E E IP65 IP67 HLG-320H-12 HLG-320H-15 HLG-320H-20 HLG-320H-24 HLG-320H-30 HLG-320H-36 HLG-320H-42 HLG-320H-48 12V

E E E E E E E E E E E E IP65 IP67

AC/DC Converter LS05-15BxxSS(-F) Series

IP65 IP67 MODEL CLG CLG CLG CLG CLG CLG CLG V 15 ~ 20V 24V 18 ~ 24V

75W Constant Current (700mA) LED Driver

HLG HLG HLG HLG HLG HLG HLG HLG HLG

95 ~ 108% Protection type : Constant current limiting, recovers automatically after fault condition is removed SHORT CIRCUIT

AC/DC Converter LD10-13Bxx Series

HLG-240H-12 HLG-240H-15 HLG-240H-20 HLG-240H-24 HLG-240H-30 HLG-240H-36 HLG-240H-42 HLG-240H-48 12V 36V 18 ~ 36V 16A 15A 12A 10A 8A 6.7A 5.

3000W Single Output Power Supply AK V 200A. 0 ~ 200A 3000W 150mVp-p

IP65 IP mVp-p 13.5 ~ 17V. 150mVp-p 17 ~ 22V 22 ~ 27V 4.65 ~ 9.3A 1.0% 3.9 ~ 7.8A 1.0%

IP65 IP mVp-p 13.5 ~ 17V. 150mVp-p 17 ~ 22V 22 ~ 27V. Can be adjusted by internal potentiometer or through output cable

For more information, please visit the product page. output. output current max (A)

Features : IP65 IP67 SELV

VOF XX - XXX - X

PSU s e r i es

3000W Single Output Power Supply AK V 24V 250A 200A 125A 0 ~ 250A 0 ~ 125A 3000W 0 ~ 200A. 3000W 150mVp-p 3000W

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

60W Single Output Switching Power Supply

Features : IP65 IP67 SELV

HLG-185H-12 HLG-185H-15 HLG-185H-20 HLG-185H-24 HLG-185H-30 HLG-185H-36 HLG-185H-42 HLG-185H-48 36V 18 ~ 36V 13A 11.5A 9.3A 7.8A 6.2A 5.2A 4.4A 3.

For more information, please visit the product page If your application requires forced air, view our Dc Fans. output. output current max (ma)

60W Reliable Railway DC-DC Converter. RSD-60 series. File Name:RSD-60-SPEC

E E E E E E E E E E E IP65 IP67

E E E E E E E E E E E E E IP65 IP67. 24V 30V 36V 42V 4.8A 4A 3.2A 2.65A 2.28A 96W 96W 96W 95.4W 95.76W 96W 150mVp-p 22 ~ 27V.

36V 21.6 ~ 36V 5A 5A 4A 3.4A 2.7A 2.3A 1.95A 1.7A 24V 14.4 ~ 24V 20V 12 ~ 20V. 60W 75W 80W 81.6W 81W 82.8W 81.9W 81.6W 150mVp-p.

24V 40A 0 ~ 40A 960W. 150mVp-p 20 ~ 26.4V 83% 85% 88% 88% 90%

H L G -150H s er i es

IP65 IP67 42V 5A 4.8A 4A 3.2A 2.65A 2.28A 2A. 150mVp-p. 200mVp-p 27 ~ 33V 22 ~ 27V. Can be adjusted by internal potentiometer or through output cable

24V 14.4 ~ 24V 20V 12 ~ 20V. 48V 28.8 ~ 48V 3.33A 2.67A 2A 1.67A 1.34A 1.12A 0.96A 0.84A 39.96W 40.05W 40W 40.08W 40.2W 40.32W 40.32W 40.

RSD-30 series. 30W Reliable Railway DC-DC Converter. (reinforced isolation) File Name:RSD-30-SPEC

50W Constant Current (700mA) Dimming LED Driver

HLG-80H-12 HLG-80H-15 HLG-80H-20 HLG-80H-24 HLG-80H-30 HLG-80H-36 HLG-80H-42 HLG-80H-48 HLG-80H-54 36V 21.6 ~ 36V 5A 5A 4A 3.4A 2.7A 2.3A 1.95A 1.

60W Reliable Railway DC-DC Converter. RSD-60 series. File Name:RSD-60-SPEC

SPECIFICATION FOR APPROVAL

DC/DC Converter 9 to 36Vdc and 18 to 75Vdc input voltage, 20 Watt Output Power; 3.3 to 15Vdc Single Output and ±12Vdc to ±15Vdc Dual Output

Power Supply for LEDs 320 Watt 15 Volt, Waterproof, Single Output

VISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 11/11/13 Specification Release S. Sadot A1 14/01/14 Update ope

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

42V 21 ~ 42V 4.8A 4A 3.2A 2.65A 2.28A 30V 15 ~ 30V. 200mVp-p 27 ~ 33V. Can be adjusted by internal potential meter or through output cable

PDAM500 Series 500W Power Supply

Efficiency [%] 115VAC 230VAC. Parameter Condition Value. Line Regulation low line to high line ±0.5% max. Load Regulation 10% to 100% load ±0.5% max.

HLG-150H-12 HLG-150H-15 HLG-150H-20 HLG-150H-24 HLG-150H-30 HLG-150H-36 HLG-150H-42 HLG-150H-48 12V

SPECIFICATIONS. Input Output Approvals

300W Railway Single Output DC-DC Converter

IP65 IP mVp-p. 150mVp-p 17 ~ 22V 22 ~ 27V. Can be adjusted by internal potentiometer or through output cable 5 ~ 10A 3 ~ 6A 1.0% 2.5 ~ 5A 1.

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

AcBel Product Specification

Waterproof Power Supply for LEDs 240 Watt 24 Volt, Single Output with PFC

2000W Front End Power Supply

185W Single Output Switching Power Supply IP65 IP67

Features : 15V 50A 0 ~ 50A. 750W 150mVp-p. 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

AC/DC Converter LD12-20Bxx Series

Switching Power Supply Type SPP1 60W Enclosed type

1500W Programmable Single Output AK V. 48V Rated Current. 31.3A Current Range 100A. 0~31.3A Rated Power 0~100A 1500W

IP65 IP67 SELV HLG-320H-12 HLG-320H-15 HLG-320H-20 HLG-320H-24 HLG-320H-30 HLG-320H-36 HLG-320H-42 HLG-320H-48 12V

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

IP64 HLN-40H-12 HLN-40H-15 HLN-40H-20 HLN-40H-24 HLN-40H-30 HLN-40H-36 HLN-40H-42 HLN-40H-48 HLN-40H-54 12V 20V 12 ~ 20V

FED30-48 S 05 W - N HC Series Name Input Output Output Input Remote Control Assembly Option Voltage Quantity Voltage Range Option

TRC ELECTRONICS, INC

IP64 36V 21.6 ~ 36V 4A 3A 2.5A 2A 1.7A 1.45A 1.3A 24V 14.4 ~ 24V 30V 18 ~ 30V. 60W 60W 60W 60W 61.2W 60.9W 62.4W 150mVp-p 17 ~ 22V.

HRPG-1000 series. 1000W Single Output with PFC Function. File Name:HRPG-1000-SPEC Sicherheit ID

1500W Single Output Power Supply AK V 100A 0~100A 1500W. 150mVp-p. Adjustment of output current is between 40 ~ 105% of rated output

Features : 36V. Can be adjusted by internal potentiometer A type only 6 ~ 10A 4.0 ~ 6.7A 3 ~ 5A ±2.0% ±0.5%

Features. Regulated Converter. RAC02-SE/277/W 2 Watt Single Output. RAC02- SE/277/W Wired. AC/DC Converter

HEC-70LCN-350TDAF Rev B

800W Single Output Power Supply

2000W Front End Power Supply

DRC-100 series. 100W Single Output with Battery Charger (UPS Function) File Name:DRC-100-SPEC Sicherheit ID

AC/DC Converter LB(05-25)-10BxxLT Series

PF 0.96/230VAC PF 0.96/115VAC at full load and rated output voltage PF 0.9 at 60 ~ 100% load INPUT EFFICIENCY (Typ.)

HLG-60H-15 HLG-60H-20 HLG-60H-24 HLG-60H-30 HLG-60H-36 HLG-60H-42 HLG-60H-48 HLG-60H-54 DC VOLTAGE CONSTANT CURRENT REGION Note.

IP65 IP mVp-p 13.5 ~ 17V

IP65 IP67. 54V CONSTANT CURRENT REGION Note.4 10 ~ 20V 12 ~ 24V 15 ~ 30V 18 ~ 36V 21 ~ 42V 24 ~ 48V 27 ~ 54V RATED CURRENT RATED POWER

IP65 IP67. Can be adjusted by internal potentiometer A type only. 500ms, 80ms / 347VAC / 480VAC at 95% load 180 ~ 528VAC 254VDC ~ 747VDC 47 ~ 63Hz

RCP DC VOLTAGE 48V RATED CURRENT 42A CURRENT RANGE 0 ~ 100A 0 ~ 80A 0 ~ 42A RATED POWER. 2016W RIPPLE & NOISE (max.) Note.2 150mVp-p.

Transcription:

Features UL, CE Approved RoHS directive compliance Small, compact size High efficiency Universal input(ac90~264v or DC120~340V) Surface mounting technology Built in EMI filter Inrush current limit 100kHz fixed frequency Fixed output voltage Thermal shutdown(ic-temp: 140 C Min.) Low output ripple & noise Isolated input-output(3kvac) Output short circuit protection Over voltage protection(o.v.p.) Over current protection(o.c.p.) 2Years warranty Environmental Operating temperature range: -10 ~60 Storage temperature range: -20 ~70 Humidity: 20%~90%RH Vibration: 10-55Hz at 10G(98m/s²), 3minutes period, 60minutes each one X, Y and Z axis Impact: 50G(490m/s²), 11ms, once each Cooling method: natural air convection MTBF(MIL-HDBK-217F): 2.0*10 5 hours Safety UL (UL60950, CSA C22.2 NO.60950) UL No: E227474 CE(EN60950) - through TÜV Description The C30 Series has universal AC input and there are 5 models with single output and 6 models with dual output. High reliability are achieved. A built in EMI filter is reduced the noise level.

Electrical specifications INPUT Voltage Current Frequency Efficiency Inrush current (at cold start) Leakage current AC90~264V (or DC 120~340V) 50/60Hz (note) 0.89A Maximum 47~440Hz Max. (50~60Hz typ.) 77% Typ. 30A Max. @ 120VAC. / 60A Max. @ 240VAC 0.5mA Max. @ 110VAC / 0.75mA Max. @ 220VAC OUTPUT Voltage adj. Range Ripple and noise Line regulation Load regulation Dynamic load regulation Temperature regulation Rising time Hold up time Minimum load ±10% typical @Output1 1% maximum ±1% maximum ±1% maximum @Output1 / ±2%maximum @Output2 ±3% maximum @Output1 ±1% Typical 100ms Maximum 17ms Minimum Output1 current > Output2 current(dual) Protection circuit Over current protection Over voltage protection Over temperature protection Works at over 105% of rating & recovers automatically 115~140% of rating 80 Minimum (Latch-up mode) Isolation specifications Isolation Resistance Input-Output Isolation Voltage Input-FG Output-FG DC 500V, 70MOhms Min. AC 3KV, 1minute, 10mA. AC 2KV, 1minute, 10mA. AC 0.5KV, 1minute, 10mA. General specifications Switching frequency Calculated MTBF 100kHz 2.0*10 5 hours Weight 270g or less(single), 370g or less(dual) NOTE: For cases that conform various safety specifications(ul, CSA, CE etc). It require input voltage and frequency range will be 100-240Vac, 50~60Hz.

Ordering information CS30-12 Series name S: single Output voltage Output power D: dual Input Output1 Output2 Maximum power Ripple & Noise Efficiency typical Model number 3.3V@6.0A 19.80W 30mVp-p 72% CS30-3R3 5V@6.0A 30.00W 50mVp-p 73% CS30-5 12V@2.5A 30.00W 100mVp-p 75% CS30-12 15V@2.0A 30.00W 120mVp-p 78% CS30-15 AC90~264V 24V@1.5A 36.00W 150mVp-p 79% CS30-24 or 5V@3.0A 5V@3.0A 30.0W 50/50mVp-p 75% CD30-55 DC120~340V 5V@3.0A 12V@1.2A 29.4W 50/120mVp-p 77% CD30-52 5V@3.0A 15V@1.0A 30.0W 50/150mVp-p 77% CD30-5F 5V@3.0A 24V@0.6A 29.4W 50/200mVp-p 78% CD30-54 12V@1.2A 12V@1.2A 28.8W 120/120mVp-p 78% CD30-1212 15V@1.0A 15V@1.0A 30.0W 150/150mVp-p 78% CD30-1515 Pin assignments Single output Dual output Connector Derating curve 1. AC(L) 2. AC(N) 3. F.G. 4. -V 5. V 1. AC(L) 2. AC(N) 3. F.G. 4. V2 5. V2 6. V1 7. V1 CN1

Dimensions

Inrush Current - 240Vac input TEST CONDITION - Full load output - Phase 90 input start, current measure CS30-3R3 22.4A CS30-5 24.5A CS30-12 23.9A CS30-15 23.4A Inrush current concerns wrong to fuse, input rectifier, power-switch, circuit break and parts. It degrades the another circuit voltage and occurs system error. If you defuse inrush current. You add NTC or Inrush current limiter to external circuit. High rating voltage input Max30A @ 120Vac Max60A @ 240Vac CS30-24 23.7A

Rising Time - 100Vac Input TEST CONDITION - Full Load Output - Output Voltage 10% ~ 90% Rising Time Measure CS30-3R3 2.5mS CS30-5 1.5mS CS30-12 10.1mS CS30-15 11.5mS Max 100ms between output voltage 10%~90% CS30-24 14.6mS

Hold up Time - 100Vac Input TEST CONDITION - Full Load Output - When Input off Phase 0 or 360, Output Voltage off Time Measure CS30-3R3 18.9mS CS30-5 12.1mS CS30-12 12.1mS CS30-15 13.5mS The amount of time that a power supply's outputvoltage remains within the specified-voltage ranges after it's input voltage interrupts. Low rating voltage Minimum 10ms @100Vac input CS30-24 10.6mS

Start up Time - 100Vac Input TEST CONDITION - Full Load Output -When Input on Phase 360, Output Voltage 100% rise Time Measure CS30-3R3 3.8S CS30-5 3.4S CS30-12 2.2S CS30-15 1.4S Amount of delay time and rise time. After input- voltage injects. CS30-24 3.8S

Over Shoot - 240Vac Input TEST CONDITION - Full Load Output CS30-3R3 0V CS30-5 0V CS30-12 0V CS30-15 0V When turn-on, the output overshoot voltage shall not exceed 5% of normal Voltage value no Load or full Load connected. CS30-24 0V

Output Ripple & Noise - 100Vac Input TEST CONDITION - Full Load Output - Ele-cap(47uF)and Ceramic-cap(104), Output Terminal CS30-3R3 43.2mVpp CS30-5 18.8mVpp CS30-12 60.5mVpp CS30-15 81.5mVpp *Ripple & Noise: Oscilloscope bandwidth 20MHz. The length of the output line should be shorter than 1meter and it needs to be twisted. CS30-24 66.0mVpp

Efficiency Curve(Load Variation) 5 4 2 1 5 4 2 1 Load(%) 10 25 50 75 100 Eff(%) 40.8 59.0 68.7 71.0 70.6 Load(%) 10 25 50 75 100 Eff(%) 51.8 68.6 74.4 76.5 76.4 CS30-3R3 / 3.3V 6.0A CS30-5 / 5V 6.0A 5 4 2 1 5 4 2 1 Load(%) 10 25 50 75 100 Eff(%) 50.5 67.1 75.9 79.0 78.6 5 4 2 1 CS30-12 / 12V 2.5A Load(%) 10 25 50 75 100 Eff(%) 45.4 63.3 73.3 76.7 79.0 CS30-15 / 15V 2.0A Input 220Vac, Variation of efficiency, from minimum load to maximum load. Load(%) 10 25 50 75 100 Eff(%) 53.5 68.9 77.2 79.0 80.5 CS30-24 / 24V 1.5A

Efficiency Curve(Input Voltage Variation) 5 4 2 1 5 4 2 1 V in(v) 90 110 220 264 Eff(%) 72.3 73.5 70.9 68.2 CS30-3R3 / 3.3V 6.0A V in(v) 90 110 220 264 Eff(%) 75.9 77.2 76.4 74.6 CS30-5 / 5V 6.0A 5 4 2 1 5 4 2 1 V in(v) 90 110 220 264 Eff(%) 79.8 80.8 78.5 76.3 5 4 2 1 CS30-12 / 12V 2.5A V in(v) 90 110 220 264 Eff(%) 78.2 79.8 78.8 76.8 CS30-15 / 15V 2.0A Variation of Efficiency, from Minimum input Voltage to Maximum input Voltage V in(v) 90 110 220 264 Eff(%) 81.8 82.7 80.5 78.3 CS30-24 / 24V 1.5A

Electro Magnetic Interference Application. C30 Series is needs to reduce Electromagnetic Interference, use the external L-C noise filter at the input of the Converter. 1. Configuration L L V C1 224MKP SMPS LOAD N LF1 LF2 N -V FG FG 2. Components C1 = 220nF / 275Vac, X2 Capacitor LF1 = 20mH Common Mode Line Filter, Toroidal core φ14.0mm LF2 = 20mH Common Mode Line Filter, Toroidal core φ14.0mm

Calculating Reliable Values of MTBF 1. Calculating method Calculated based on part count reliability projection of MIL-HDBK-217F Individual failure rates λg is given to each part and MTBF (Mean Time Between Failure) is calculated by the count of each part. <Formula>: n MTBF = 1/ λepuip = 1/ ( Ni(λG Q)i *10^6 (Hours) i=1 λequip : Total Equipment Failure Rate (Failure/10^6Hours) λg : Generic Failure Rate for The ith Generic Part (Failure/ 10^6Hours) Q Ni n : Generic Quality Factor for The ith Generic Part ( Q=1) : Quantity of ith Generic Part : Number of Different Generic Part Categories 2. MTBF Values MTBF 205,809(Hours) PART Num. Failure Rate Failure Rate*n Remark n λg(f/t) λg n(f/t) Logic IC 1 0.06000 0.06000 101~1000gate Transistor, FET 1 0.49500 0.49500 IC Separate Voltage Regulator(TL431) 1 0.02400 0.02400 Photo-coupler(SCR) 2 0.14850 0.29700 Varistor 1 0.01595 0.01595 Thermister 1 0.01400 0.01400 Resistor Wirewound, Accurate 1 0.02400 0.02400 Resistor Volume 1 0.02400 0.02400 Resistor Chip 21 0.01600 0.33600 Capacitor-ele 6 0.01900 0.11400 Capacitor-film, MF 3 0.00700 0.02100 Capacitor-ceramic 4 0.02600 0.10400 Capacitor-MLCC 7 0.05300 0.37100 Diode Fast Recovery, Power 3 0.12650 0.37950 Diode Switching 1 0.00517 0.00517 Diode Zener (and Avalanche) 5 0.01815 0.09075 Diode LED 1 0.00259 0.00259 Diode Bridge 1 0.12650 0.50600 *4 Inductor or Choke 3 0.00010 0.00029 Transformer, Power 1 0.15900 0.15900 Line Filter 1 0.00440 0.00440 Terminal block 1 0.06200 0.31000 *5(pin) Reflow soldering 73 0.00014 0.01022 Flow soldering 95 0.00780 0.74100 PCB 1 0.37000 0.74000 *2 Fuse 1 0.01000 0.01000 Total Equipment Failure Rate λg n(f/t) 4.858863 MTBF = 10^6 / λg(f/t) 205809.4661

Reliability Specification Standard Remarks Dry heat Cold Thermal shock Temperature, humidity cycle IEC60068-2-2 IEC60068-2-1 IEC60068-2-14 IEC60068-2-30, IEC60068-2-38 Vibration IEC 60068-2-6 Mechanical shock IEC 60068-2-27 Electrostatic Discharge immunity IEC 61000-4-2 Immunity to radio frequency EM-fields IEC 61000-4-3 Electrical fast transient/burst immunity IEC 61000-4-4 Surge immunity IEC 61000-4-5 B10 Life test B10 Life is the time by which 10% of the product population will get failed

Instruction manual 1. Basic connection Input AC85~264V 50~60Hz NOTE: L N FG Output GND Load - Use a schottky or fast recovery diode this has a low VF. 3. Series Operation Choose a diode in accordance with voltage, power dissipation and heat radiation. - Voltage : V > Vo 3 - Current : I > Io 3 - Design a proper heat sink according to power loss at diode ( Pw = Vf Io ). A: For safety as well as improved noise, ensure secure connection of the FG terminal to the ground terminal of the equipment. B: To avoid excessive voltage drop and for - Use a schottky or fast recovery diode this has a low VF. improved noise, and short and thick wire should be used to connect the load. Length below 50Cm & wire thickness of 4.0A/mm 2 are recommended for reducing wire loss when wire connection is necessary. 2. Parallel Operation This supply can be operated the following ways. Choose a diode in accordance with voltage, power dissipation and heat radiation. - - - Load - Load - - - - Voltage : V > Vo 3 - Current : I > Io 3 - Load Load - - 4. Over Current Protection The C30 Series is equipped with an over current protection circuit. When the short or overload condition is removed, the output will automatically recover. This setting is fixed and cannot be varied - Design a proper heat sink according to power loss at diode ( Pw = VF Io ) externally. If the short or overload condition continues, the power module could be damaged due to the heat condition.

5. Over Voltage Protection C30 series are equipped with an over-voltage protection circuit by zener diode. If zener diode is opened, Vcc rise up, it becomes possible to implement an over voltage protection. Latch on mode. If zener diode is short, output is shorted. It becomes possible to implement a short circuit Protection. 6. Over Temperature Protection Temperature protection is provided by a precision analog circuit that turns the output MOSFET off when the junction temperature exceeds the thermal 10. Withstand Voltage C30 series are designed to withstand 3KVAC (10mA) 1 minute between input output for the withstand voltage test, 2kVAC(10mA) 1minute between input-fg, and 500VAC(10mA)1 minute between output-fg. The applied voltage must be increased gradually from zero to the testing value, and then decreased gradually at shut down. Especially stay away from use of a timer. Where a pulse of several times the applied voltage can be generated. INPUT-OUTPUT shutdown temperature (140 Minimum). When the junction temperature cools to below the hysteretic temperature, normal operation resumes providing automatic recovery. L N FG Output GND 7. Line Regulation Maximum line regulation is maximum output voltage change when the input volt is slowly varied with in the input voltage range. 8. Load Regulation Maximum load regulation is maximum output voltage value change when varying the load current slowly within the standard output current range. 3KVAC, one minute, 10mA INPUT-FG L Output N GND FG 2KVAC, one minute, 10mA OUTPUT-FG 9. Isolation Resistance The isolation resistance is more than 100MΩ at 500VDC when tested with DC isolation between the output and the case. Make sure that during testing, the isolation tester does not produce a high pulse L N FG Output GND when the applied voltage is varied. Ensure that the tester is fully discharged after the test.] 500VAC, one minute, 10mA

11. Fuse rating Rating: 250V 3.15A Type: Time-Lag 12. Block Diagrams Circuit topology : Forward Switching frequency : 100KHz(fixed) UL/CSA or IEC approved type should be used to meet safety requirements. When changing fuse ensure that the same type and ratings used. Avoid using fast-blow fuse. AC 90~264V or NOISE FILTER RECTIFIER & FILTER RECTIFIER & FILTER OUTPUT DC 120~340V SWITCHING IC FET FEED BACK PWM IC Power Plaza co., Ltd #1401, Daeryung Techno Town 493-6 Gasan-Dong, Kumchon-Gu, Seoul, 153-774, Korea Tel: 82_2_855_4955 Fax: 82_2_855_4954 E-mail: sales@powerplaza.co.kr