P P S - M W S C A N 2 H

Similar documents
6000 W, 2450 MHz Microwave Generator GMP 60K SM 56T400 FST 3 IR

USER MANUAL XLB-2500 Short Arc Xenon Lamp Ballast

HITEK POWER OLS10K SERIES

HITEK POWER OL1K SERIES

HITEK POWER OLS10KD SERIES

HITEK POWER OLH10K SERIES

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

Series OLS10KD 10kW HIGH VOLTAGE POWER SUPPLY

SPECIFICATION. Online UPS 3000VA

HITEK POWER OL3000 SERIES

USER MANUAL XLB-650 Short Arc Xenon Lamp Ballast

HITEK POWER XR KW X-RAY POWER SUPPLY MODULE

Series OLH10KD 10kW HIGH VOLTAGE POWER SUPPLIES

HITEK POWER XR KW X-RAY POWER SUPPLY MODULE

PLASMA POWER SUPPLIES

An RS485 bus is used for command, monitoring and diagnostic information that can be supplied to a system controller.

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA

DXM 300W-1200W X-RAY GENERATOR MODULE REV. AB

HOMER Analyzer ISM 900 MHz, R-9 Waveguide

COM-POWER OPERATION MANUAL ACS W

Advantages. Applications

USER MANUAL. CW Diode Driver Power Supplies

USER MANUAL LDY CW Diode Driver Power Supplies

Advantages. Applications

8450 Series CellGuard TM Power / VSWR Monitors

PS-3000-AVAS PS-5000-AVAS DC SOURCE FOR AUTOMOTIVE TESTS

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03

maxon document number:

N. TEST TEST DESCRIPTION

7RU SSPA Chassis. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

Preliminary Specification

Ku-Band VSAT Block Up Converters

1.0 Introduction. 2.0 Safety/Protection Features. 1.1 Scope. 1.2 Change Management. 2.1 Mismatch Protection. 2.2 Transient Protection

HOMER Analyzer ISM 2.45 GHz, WR-340 Waveguide

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

Industrial PSU with universal input voltage range ( VAC line to line) and configurable output voltage. North America

Metasys Integrator Power Measurement Ltd. Application

Schlöder GmbH - EMC Test and Measurement Systems Model #

DRC 3500 Versatile Ka-Band Transceiver

MG MW S-Band Magnetron

Rubidium Frequency Standard Model AR133A Ruggedized Low Profile

Advantages. Applications

ERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES

C-Band VSAT Block Up Converters

HITEK POWER OL600W SERIES

External RF Driver. Electrical Driver for AOTF-crystal. Instruction Manual

RS232. DC POWER SUPPLY 20kW 3 RANGES

PDAM500 Series 500W Power Supply

High Voltage Power Supply VAPTEC LITEC PLASMATEC WELTEC GLOWTEC

RF Amplifier Data Sheet. BT02000-AlphaA-100ms 10kHz-3MHz 2kW. Scientific and Industrial Applications

Chapter 6 Specifications

RF Amplifier Data Sheet. BT01000-Gamma 5MHz-400MHz 1kW. Scientific and Industrial Applications

Electrical Specifications

Contents. Introduction and description Package contents Device identification PM Options... 80

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

M-Bus Master MultiPort 250L Installation and User Guide

Thermo Electric Cooling Temperature Controller TEC Controller / Peltier Driver ±16 A / ±22 V or 31 V

100U1000. Features. 100 watts CW 100kHz 1000MHz Class A Portable Full VSWR tolerant CE & RoHS Compliant High Efficiency

STOLPA: Integrated WR-975 Waveguide Autotuner

Side view View from below Rear view

WORLD LEADING PRODUCTS FOR LASER SCIENTISTS AND ENGINEERS

REIMESCH KOMMUNIKATIONSSYSTEME GMBH ALPIN HF Linear Amplifier - USER MANUAL. v1.0

IB IL 24 PWR IN/PS IB IL 24 PWR IN/PS-PAC

C B. Models. Models 2MOPP

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

MT3200A TRAVELING WAVE TUBE MEDIUM POWER AMPLIFIER

OPERATING MANUAL SERIES R B F 400 VAC BRUSHLESS RACK SYSTEM

200W 500W, Air Cooled QUBE Fiber Lasers

400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Electronic Load ZSAC

Amplifier HF MHz

Rubidium Frequency Standard Model AR133A Ruggedized Low Profile

HOMER Autotuner ISM 5.8 GHz, R-58 Waveguide

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

LED Driver Compact dimming

PCX-9000 Series Datasheet

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

LYRA 501 USER S MANUAL

1. General Instructions 2 2. Safety 2 3. Lamp Starting Test Instrument LSTI 5 3

INSULATION / VOLTAGE WITHSTAND TEST INSTRUMENT SERIES

OEM s #1 Choice for X-Ray Sources and Generators. Focus on Performance, Reliability, Form Factor, and Versatility.

Features 100A400AM20. 4kHz 400MHz Class A Portable Full VSWR tolerant CE & RoHS compliant High Efficiency

PHASED OUT. LED Driver Compact dimming. Driver LCAI 55W 900mA 1750mA ECO C ECO series

LB115S 115W Single Output

Stabilized Differential Relay SPAD 346. Product Guide

AUM FAMILY Programmable DC Power Supplies

HITEK POWER EG353 SERIES HIGH-STABILITY 35 KV HIGH VOLTAGE POWER SUPPLIES FOR PRECISION SEM E-BEAM APPLICATIONS

Thermo Electric Cooling Temperature Controller TEC Controller / Peltier Driver ±16 A / ±19 V

Types VIS and CRE. A e. Compliance with Standards. Uses. Features

150W1000B. Features. 150 watts CW 80MHz 1000MHz Class A Portable Full VSWR tolerant CE & RoHS Compliant High Efficiency

LED Driver Compact fixed output

FEATURES: Reduced Depth. Output RF Power Hold. Easily Accessible Diagnostic Port. Programmable Alarms. Event And Maintenance Logs. Ethernet Interface

Power IT LV Active Filters PQFA - PQFL - PQFT

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL

SHQ Series. Technical information Last changed on: DIGITAL CONTROLLABLE HIGH PRECISION AC DESKTOP HV SUPPLY

Ku-Band. Reliable Designed and built to survive in extremely adverse environmental conditions. Operates in ambient temperatures up to 60 C.

MQH0XX-YYDS3-ZZZ-2S. High Power 2 Channel RF Driver: For 2 Acousto-optic Q-Switches. Description: Key Features: Applications:

The New Standard in High Power Redundant Microwave Amplifier Systems Has Arrived

Transcription:

µ-controller-systems / HARD- & SOFTWARE-DESIGN POWER-SUPPLIES FROM MILLIWATTS TO KILOWATTS Device: PPS-MWS-2000-4000-CAN2H 04 / 2018 Page 1 / 6 S w i t c h i n g M o d e P o w e r S u p p l y f o r M a g n e t r o n u s e D u a l P o w e r - S u p p l y P P S - M W S - 2 0 0 0-4 0 0 0 - C A N 2 P P S - M W S - 2 0 0 0-4 0 0 0 - C A N 2 H T E C H N I C A L D A T A PPS-MWS-2000-4000-CAN2 DUAL pulsed Magnetron Power Supply PPS-MWS-2000-4000-CAN2H DUAL pulsed Magnetron Power Supply with Heat-Regulation 2x 2000W/4000W (continous / pulse-peak) MicroWave-/HF-Power Magnetron-Type: 2.0 kw / 2450 MHz Dimensions: 19 rack (plug-in-case) Adjustable Power from 10 % - 100 % 3 units height Standard Ripple 508 mm depth (incl. Fan s) CAN-Bus controlled (CAN01 or CanPH02c) Air- and water-cooled: water-cooled (5 l/min; 4 bar) CAN01 -Protocol Input POWER: 3-ph 400V~ 47-63 Hz (max 15,0 A/ph) or CanPH02c-Protocol (coming soon) Input-AUX-PWR: 230V~ 47-63 Hz 2x Magnetron Heater Regulation (optional) Leading edge phase controlled heat-regulation Delivered with all needed device connectors: - Interlock - connector 1x - 3x 400 V~ / 3 phase - connector 1x - 1x 230 V~ - connector 1x - MW-Head - connector 2x - HV -LEMO (10 kv) - connector 2x - Reflected-Power - connector 1x Not included: - Water-IN /-OUT - flexible tube (e.g.: FESTO PUN 10 x 1.5 ) - CAN-Bus - connector Attention: -- Microwaves and High-Voltage are dangerous -- Very important to avoid any injury : Use INTERLOCK -Switch(es) to prevent any microwave output, if microwave-system is not complete closed. Responsible for the correct interruption of the microwave energy production is the constructor of the complete microwave-system.

Device: PPS-MWS-2000-4000-CAN2H 04 / 2018 Page 2 / 6 1 General Description / Block Diagram The PPS-MWS-2000-4000-CAN2 power supply could be controlled over CAN-Bus Either with the CAN01 Protocol or with the CanPH02c Protocol ( coming soon ) CAN-Bus-Protocol about the placed in the Block Diagram CAN01 (and CanPH02c) - Protocol CAN01 / CanPH02c Manual Heat Regulation ( optional )

Device: PPS-MWS-2000-4000-CAN2H 04 / 2018 Page 3 / 6 2 Technical Data Suggested Magnetron Type... Preheating Time... Waveguide R26 / WR340 --- 2M259 or NL10250 (2.0 kw) Magnetron heating-time included Input Voltage... 3x 400V~ +/- 10 % (359 V~... 438 V~) / 47 63 Hz, 3 phase Input current... < 9 A rms / phase @ full load Input Protection... 3-phase-Fuse must be provided externally: 3-ph Fuse 10A T (time lag), 400V~ Input (auxiliary) Voltage... 1x 230V~ +/- 10 % (200V~... 265 V~) / 47 63 Hz, 1 phase Input current... < 2 A rms @ 230 Vac @ full load Input Protection... 1-ph-Fuse/automatic circuit breaker implemented in device positioned on back-side: 1-ph Fuse 2A T (time lag), 230 V~ Auxiliary Power Intern... 24 V DC, 50 ma Output. Magnetron-Head-1 -Connector 24 V DC, 50 ma Output. Magnetron-Head-2 -Connector 24 V DC, 50 ma Output. ILOCK/HV-ON -Connector Output Power... 2x 2.600 W (magnetron input power @ max CW) 2x 2.000 W HF-Power continous Output current... output current regulation 2x 50 ma to 725 ma ( 725 ma @ continous 2.000 W HF-Power), 2x 50 ma to 1.450 ma (1.450 ma @ pulse-peak 4.000 W HF-Power) Output current ripple... Standard Ripple Output polarity... 3.800 V to 4.200 V, negative in respect to ground potential Harmonic Distortion... Meets EN 61000-3-2 for class A Transient overvoltage... Meets EN 61000-4-4 for class B EMI Filtering... Meets EN 55022 for class B Output current signal... Output voltage signal... POWER-OUT over CAN-Status - message POWER-OUT over CAN Status - message CONTROL Signals from extern into device CAN-Bus controlled... COMMAND- / STATUS Messages ILOCK-Connector INPUT s: INTERLOCK..... 0V / not connected = error / Ilock opened, 24V = okay / Ilock closed COOL-Extern..... 0V / not connected = error / NO cooling, 24V = okay / cooling MAG-HEAD-Connector INPUT s: WATER-Guard.... 0V / not connected = error / no cooling, 24V = okay / water cooling Temp-2-High...... 0V / not connected = error / Temp-2-High, 24V = okay / Temp okay ARC-detect....... 0V / not connected = error / ARC detected, 24V = okay / NO ARC STATUS Signals from device to extern CAN-Bus controlled... COMMAND- / STATUS Messages ILOCK-Connector HV-ON.......... OUTPUT: connection of lamp/led (24 V) possible If HV = ON HV-ON-Pin connected to ground CAN-01 - Pulse - Timing ON_TIME ( Pulse-Hi -Duration ) 1 ms... 24 ms OFF_TIME ( Pulse-Low -Duration ) 1 ms... 250 ms Max. Pulse-Frequency f = 500 Hz

Device: PPS-MWS-2000-4000-CAN2H 04 / 2018 Page 4 / 6 3 Environment Conditions USE........................... Temperature..................... INDOOR USE only 5 C to 40 C 4 Mechanical Data Dimension without handhold L x W x H 508 x 483 x 132.5 mm 3 (length x width x height) Dimension with handhold L x W x H 548 x 483 x 132.5 mm 3 19 rack (plug-in-case) 3 rack-units height Weight (approximately)............. 18 kg

Device: PPS-MWS-2000-4000-CAN2H 04 / 2018 Page 5 / 6 5 Back-Side of Device / Connectors >> Connectors << Abbreviations: PS-1... Power-Supply-1 PS-2... Power-Supply-2 HV-1 > High-Voltage PS-1 HV-2 > High-Voltage PS-2 X1 > INPUT_: 3 phase... 400 V~ X2 > INPUT_: 1 phase AUX 230 V~ X3-1 > OUTPUT: MW-Head-Output PS-1 X3-2 > OUTPUT: MW-Head-Output PS-2 X4 > INPUT : Reflected Power (new) PE > protective earth M1 > Ground-1 M2 > Ground-2 ILOCK > Interlock - Connector F1.. > Fuse 230 V~ (AUX-Voltage) WATER-IN > water-cooling IN WATER-OUT > water-cooling OUT FAN-1 > air-cooling PS-1 FAN-2 > air-cooling PS-2 Communication-Ports: CAN > CAN-Bus-Port (SUBD9) CANID > Can-Start-ID (Dip-Switches) S-1 > Serial PS-1 (Firmware-Update) S-2 > Serial PS-2 (Firmware-Update) Back-Side: - NOTE - X4 Reflected Power (new)

Device: PPS-MWS-2000-4000-CAN2H 04 / 2018 Page 6 / 6 6 Connectors Details & Pinning 6.1 Connectors Details Needed Cable-Connectors included in delivery of new device: Qty Name Definition male /female Producer Factory-Nr 1x X1 3x 400V~ 3x 400V~ /50Hz (47-63Hz) 3 Phase female Binder 693.99-4222-00-04 1x X2 1x 230V~ 1x 230V~ /50Hz (47-63Hz) 1 Phase female Binder 693.99-4226-00-07 2x X3-1 MW-Head-1 MW-Head-1 Power-Supply-1 male Binder 693.99-4225-00-07 X3-2 MW-Head-2 MW-Head-2 Power-Supply-2 1x X4 Refl-Pwr Reflected-Power + Meas-Power-Ext. female Binder 581.99-2022-02-06 1x ILOCK Interlock ILOCK for both Power-Supplies male Binder 678.99-0617-00-06 2x HV-1 HV-2 Hi-Volt-1 Hi-Volt-2 HV-1 from HV-2 from Power-Supply-1 Power-Supply-2 male LEMO ( -10kV ) FFA.1Y.410.CLAC47 Connectors NOT included in delivery of new device: Qty Name Definition male /female Producer Factory-Nr 1x CAN Can-Bus To control Power-Supply-1 female And Power-Supply-2 2x S-1 Serial-1 RS232 of Power-Supply-1 male S-2 Serial-2 RS232 of Power-Supply-2 for Firmware-Update 2x WATER Water-IN Cooling of Power-Supply-1 FESTO PUN10x1.5 Water-OUT and Power-Supply-2 6.2 Connectors Pinning 1. X1 400V~/50 Hz -- 3 Phase 1,5 mm 2 Pin Name Definition 1 U 400V~ / 50Hz (47-63Hz) Phase-1 2 V 400V~ / 50Hz (47-63Hz) Phase-2 3 W 400V~ / 50Hz (47-63Hz) Phase-3 4 PE Protective Earth 2. X2 230V~/50 Hz -- 1 Phase 1,0 mm 2 1 N N 230V~ / 50Hz (47-63Hz) 2./. 3./. 4./. 5./. 6 L L 230V~ / 50Hz (47-63Hz) PE PE Protective Earth 3. X3-1 MW-Head-1 230V~ 1,0 mm 2 X3-2 MW-Head-2 24V 0,75 mm 2 1 N-HEAT N 230V~ / 50Hz (47-63Hz) 2 Water-guard IN: 0V=Err 24V=No Error 3 +24V Intern 24V power-supply 4 Temp-2-Hi IN: 0V=Err 24V=No Error 5 ARC IN: 0V=Err 24V=No Error 6 L-HEAT L 230V~ / 50Hz (47-63Hz) PE PE Protective Earth 4. X4 Reflected-Power 0,75 mm 2 1 Forward Power 1 NOT connected at moment 2 Reflected Power 1 INPUT: 0.. 10 V 3./. 4 Reflected Power 2 INPUT: 0.. 10 V 5 Forward Power 2 NOT connected at moment 6 GND Ground 5. ILOCK Interlock 0,75 mm 2 400V / 3 Phase 230V / 1 Phase MW-Head Reflected - Power 1 +24V/max 50mA Intern 24V power-supply 2 GND Intern GND power-supply 3 4 HV-ON Indicates HV-ON 5 HW-ILOCK-IN Hardware-ILOCK extern connected 6 Cool-extern Cool-Extern input for detection ILOCK connector on backside of device