Complex Solution for the Distribution Substation REF 542plus. Application and Setting Guide

Similar documents
Differential Protection with REF 542plus Feeder Terminal

REF 610 Feeder Protection Relay. Technical Reference Manual

Fault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice

Procontrol P14 89AS30R0100 Module and Application Description Analog Signal Multiplier

Relion 605 series Self-Powered Feeder Protection REJ603 Product Guide

Protection of Electrical Networks. Christophe Prévé

Stabilized Differential Relay SPAD 346. Product Guide

2015 Relay School Bus Protection Mike Kockott March, 2015

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

Directional or Non-Directional Earth-Fault Relay REJ 527. Technical Reference Manual

MN026005EN. EAFR-101S Arc Point Sensor Relay User Manual

REF42plus HMI Cutting Tool Operating Guide

KENYA ELECTRICITY GENERATING COMPANY LTD

Multimeter 560CVD11 Data sheet

Relion 605 series. Self-Powered Feeder Protection REJ603 Application manual

Modular range of digital protection relays

Multimeter 500CVD21 RTU500 series

Data Acquisition Modules/ Distributed IO Modules

BUS2000 Busbar Differential Protection System

I -limiter The world s fastest switching device

SFIBER Fibre-optic Option Card for Lon Star Coupler RER 111. Technical Reference Manual

Draft Kenya Standard for Balloting Not to be Cited as Kenya Standard

REB500 TESTING PROCEDURES

Company Directive STANDARD TECHNIQUE: TP6F/1. Power Measurement Conventions

MN026004EN. EAFR-101 Arc Point Sensor Relay User Manual

RETROFITTING. Motor Protection Relay. Two mountings are available, Flush Rear Connection (EDPAR) or Projecting Rear Connection (SDPAR).

Catalogue 1SFC en, Edition 3 November 2003 Supersedes Catalogue 1SFC en, Edition 2 November Arc Guard System TVOC

Integration between the MV protection and control unit REF542 and the LV protection trip unit PR123: selectivity and earth fault 1SDC007402G0201

ABB AG - EPDS. I S -limiter The worldʼs fastest limiting and switching device

SPAD 346 C Stabilized differential relay

VI 3 - i TABLE OF CONTENTS

Distributed busbar protection REB500 Technical Manual

SYNCHRONISING AND VOLTAGE SELECTION

presentation contents application advantages

Substation Preventive Maintenance

User s manual and Technical description. Self-Powered Feeder Protection REJ603

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator

SPAE 010, 011 High Impedance Protection Relay

Hamdy Faramawy Senior Application Specialist ABB Sweden

ELE-CMOS-E-2001 Electrical Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

SPAA 341 C. Feeder Protection Relay. User s manual and Technical description SPAA 341 C. U aux V ~ V. f n. t 2 > [ s ] 0 I 0 >> Trip

New solution for feeder earth-fault protection

General Requirements. Technical Specification LVAC Systems

Protective Relays Digitrip 3000

Connecting the automated field Building blocks for the modern field network

Single Line Diagram of Substations

Protection Relays. U-MLEs-PLv. Ultra Line. DC SUBSTATION PROTECTIVE RELAY (double voltage Line Test) 32, 45, 49, 64, 76, 79, 80

Substation Automation Products. Distributed busbar protection REB500 Technical Manual

Feeder Protection Relay REX 521. Product Guide

Cause, Effect & Mitigation Strategies

AQ F201 Overcurrent and Earthfault

Protection Relays. U-MLEs-PLv-Ts. Ultra-Ts. DC SUBSTATION PROTECTIVE RELAY (double voltage Line Test) 32, 45, 49, 64, 76, 79, 80

1000Vac distribution system for Signalling System applications

Protection Basics Presented by John S. Levine, P.E. Levine Lectronics and Lectric, Inc GE Consumer & Industrial Multilin

SEL-311C TRANSMISSION PROTECTION SYSTEM

ZS8.4 Air-insulated medium voltage switchgear

REK 510 Current injection device for earth-fault protection of a synchronous machine rotor. User s Manual

20 - Arc Guard Systems

BCV-1203 Barcode Verification System Users Guide Version 1.2

4590 Tank Side Monitor. Service Manual. Mark/Space Communication Protocol. Software Version v2.03 SRM009FVAE0808

1960 Research Drive, Suite 100, Troy, Michigan with. REVISION: December 10, 2007 (Supersedes previous versions) Prepared by:

INSTRUCTION MANUAL. AQ F210 Feeder Protection IED

Unit 2. Single Line Diagram of Substations

1 INTRODUCTION 1.1 PRODUCT DESCRIPTION

Multifunction Protection and Switchgear Control Unit REF 542plus Protection Manual

TRAINING Learning and Training application on site. QUALIFYING Evaluation of quiz Knowledge Validation To learn required skills

Substation applications

e 2 TANGO-50 Short-Circuit Detector K Data Sheet

Standards for MV switchgear rated for arc flash protection

PROTECTION of electricity distribution networks

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

Low Voltage Products & Systems. ABB Arc Guard System TM TVOC

SPAS 348 C. Feeder Protection Relay. User s manual and Technical description SPAS 348 C V ~ V. t 2 > [ s ] f n = 50Hz 60Hz

APPLICATION OF MULTI-FREQUENCY ADMITTANCE-BASED FAULT PASSAGE INDICATION IN PRACTICAL COMPENSATED MV-NETWORK

SIPROTEC 7SJ600 Numerical Overcurrent, Motor and Overload Protection Relay

KEVA B Indoor voltage sensor

Extensive LV cable network. Figure 1: Simplified SLD of the transformer and associated LV network

269 Troubleshooting Guide 11/4/98 1

RUDOLF Digital power analyzer. Advanced Version

Switchgear Type SIMOSEC up to 24 kv, Air-insulated, Extendable

Application Note: CBLIO-ISO1-xM Cables for the Class 5 D-Style SmartMotor, Revised: 11/9/2016.

Overview/Applications

Fiber Optic Expansion Interface

Power System Protection Manual

SYSTEM MONITORING FAULT RECORDING

Company main topic [ Product ] TracFeed GR. English. Diode Rectifiers. Made in Germany

Distribution/Substation Transformer

Multilin A60 Arc Flash System

AQ T216 Transformer Protection IED

DRTS-6. DRTS-6 has been designed to test: DRTS-6. Advanced Protection Relay Test Set and Measurement System

MV protection relay. Installation assistance guide. Sepam ranges

Transformer protection IED RET 670

FRYCORDER Power Cord Burn-in Generator

HighPROTEC-2 ELECTRICAL PROTECTION MADE SIMPLE

Modbus communication module for TCX2: AEX-MOD

INSTRUCTION MANUAL BUSBAR PROTECTION RELAY GRB100 - B

APPLICATION: The heart of the system is a DSR 100 Digital Static Regulator used in conjunction with standard SCR based rectifier bridges.

SIPROTEC Protection Technology. The Basis for Highest Availability of Supply

LCC-10 Product manual

Transcription:

Complex Solution for the Distribution Substation REF 542plus

1MRS756412 Complex Solution for the Distribution Substation REF 542plus Copyrights The information in this document is subject to change without notice and should not be construed as a commitment by ABB Oy. ABB Oy assumes no responsibility for any errors that may appear in this document. In no event shall ABB Oy be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, nor shall ABB Oy be liable for incidental or consequential damages arising from use of any software or hardware described in this document. This document and parts thereof must not be reproduced or copied without written permission from ABB Oy, and the contents thereof must not be imparted to a third party nor used for any unauthorized purpose. The software or hardware described in this document is furnished under a license and may be used, copied, or disclosed only in accordance with the terms of such license. Copyright 2007 ABB Oy All rights reserved. 3

1MRS756412 Issued: 31.08.2007 Version: A/31.08.2007 Complex Solution for the Distribution Substation REF 542plus Standard indoor switchgear: 2 sections, 10 cubicles per section. Q01 Q02 Q03 Q05 Q07 Q09 Q11 Q12 Q10 Q08 Q06 Q04 A070790 Thereby is: Q01, Q02 incoming cubicles Q03, Q04 voltage transformer cubicles Q05 - Q10 outgoing feeders Q11 bus coupler Q12 bus riser The protections should be placed from economical point of but to save basic functionality of the substation. The functionality of the cubicles can be divided into several groups: High functionality (incoming feeder and bus coupler) Medium functionality (outgoing feeders) Limited functionality (VT cubicles) The task is to use maximum functionality in a cheapest way. One of the best solutions is to combine several types of the protections in order to get the best functionality. Here we offer to use REF 542plus, REF 610 and REA as an arc protection system. At first it is necessary to define auxiliary power supply. The most widespread case is 220 VDC. Then define the most complicated protections in this kind of scheme: Incoming feeders and bus coupler. REF 542plus In order to have best optionality choose REF 542plus with maximum binary I/O boards (3), also choose communication board MODBUS RTU, and software license Multi (see detailed info in the TRM). 4

1MRS756412 Complex Solution for the Distribution Substation REF 542plus Type definition code: 76B2NFFF301WB26 [76] REF 542plus [B] Mainboard - basic version [2] Power supply - rated voltage 220 VDC [N] No analog I/O [F] Binary I/O3-80 250 V/143V Standard [F] Binary I/O3-80 250 V/143V Standard [F] Binary I/O3-80 250 V/143V Standard [30] Analog input 3CT+3VT+1CT0.2A+1VT [1] Modbus RTU/SPAbus RS485 communication board [W] Housing-Wide [B] HMI V5 - IEC auxiliary voltage 110-220VDC [2] HMI cable 2.5m [6] Software Multi License This protection allows to implement all kinds of logic schemes and to fit all requirements. The outgoing feeders should be equipped with REF 610. REF 610 has only current analog inputs hence only current protections, but it is possible to implement voltage protections by using dry contacts in the interbay communications from REF 542plus. It will work like external trip. So it is possible to make underfrequency load shedding. Also REF 610 allows to implement arc selective arc protection for outgoing feeders (to control only cable compartments). By using loop sensor we can control arc in the cable compartments of the cubicle and as REF 610 gets the analog signal from current transformers of the cubicle we can achieve selective trip in case of the arc. So here we can define the order code for the protection: REF610C52HCHT REF610 type of the protection C current release of the device 5 analog input current 5A 2 earthfault current 0.2A (for better sensitivity) H auxiliary voltage AC 100/110/120/220/240 V Input voltage, DC 110/125/220/250 V C not used H input/output binary card extension (3 SO & 3 DI DC 110/125/220/250) T communication card RS_485 with input for arc protection Also it is necessary to specify the length of the loop sensor for the arc protection. They could be the following types: 1.5 m ±3% 3.0 m ±3% 1MRS120534-1.5 1MRS120534-3.0 5.0 m ±3% 1MRS120534-5.0 The length depends on the size of the cubicle and of the mounting track. 5

REF 542plus Complex Solution for the Distribution Substation 1MRS756412 164 160 177 (4U) 149.3 180.1 30.8 177 Dimensions_a The dimension of the protection is on the picture above. Dimensions_a Some notes about wiring in the cubicles with REF 610. To wire properly REF 610 it is necessary to put the following input signals: CB position open CB position closed External trip (if needed) CBFP (from downstream cubicle) Overcurrent protection blocking from downstream cubicle (if needed) There is no inputs for the earthing switch or CB disconnector (truck). So interlocking should be made by dry contacts. Output contacts PO1, PO2 and PO3 are used for CB control. It has TCS function. (for TCS application see TRM p.70). Output contacts also are used for CBFP and overcurrent blocking the upstream CB (incoming or bus coupler), signaling contacts. Arc protection Arc protection: as the main unit for arc protection REA is used. REA is the independent arc protection unit which works separately from usual relay protections. REA takes current analog inputs from incoming CT's and light signal from it is own loop. REA protection unit has one input for loop sensor to control the following compartments: Cable compartment of the incoming cubicle Busbars of the section CB compartment of the section 6

1MRS756412 Complex Solution for the Distribution Substation REF 542plus So when the arc occurs in the mentioned above compartments REA trips the incoming CB in order to have selectivity. But it will not trip if the arc occurs in the cable compartment of the outgoing cubicle. REA has 2 trip contacts. One usually trips the CB, second one is usually for signaling purposes. So the scheme of the arc protection: Q1 3l M1 TRIP 3 Q2 HSO 2 HSO 1 DI1 Q3 3I+Io Q4 3I+Io DI1 DI1 Q5 3I+Io Q6 3I+Io DI1 S1 S2 S3 Code definition for the arc protection: REA-101-AAA S4 a040364 7

REF 542plus Complex Solution for the Distribution Substation 1MRS756412 REA 101_right_coi300 It has power supply unit for 110 240 VAC / 110 250 VDC. Also it is necessary to order the loop sensor for the protection. To calculate the length you need the general arrangement plan. Loop has to be wired via busbar compartment and comes back from CB compartment (or vice versa). The total length is double front size of the section plus length of two distances between CB compartment and busbar compartment plus mounting backup (20%). REA has standard types of the sensors: 5 M ± 3 % 1MRS 120512.005 10 M ± 3 % 1MRS 120512.010 15 M ± 3 % 1MRS 120512.015 20 M ± 3 % 1MRS 120512.020 25 M ± 3 % 1MRS 120512.025 30 M ± 3 % 1MRS 120512.030 40 M ± 3 % 1MRS 120512.040 50 M ± 3 % 1MRS 120512.050 60 M ± 3 % 1MRS 120512.060 The maximum length of the sensor is 60 m. The loop is constantly controlled. 8

1MRS756412 Complex Solution for the Distribution Substation REF 542plus MCB recommendations for different circuits: Type of the circuit\voltage 110 VDC 220 VDC Protection supply S202-P-K6 S282-UC-K4 Binary inputs S202-P-K2 S282-UC-K1 MCB should be with K-characteristic (8-12 Inom). 120 1.05 1.2 60 40 20 10 6 4 Seconds Minutes 2 1 40 20 10 6 4 2 1 0.6 0.4 0.2 0.1 0.06 0.04 0.02 Z K 0.01 1 1.5 2 3 4 5 6 8 10 15 20 30 10 14 18 multiples of rated current It is better to separate power supply circuits from binary inputs and signaling circuits. OEPM0086tutti_cut For more detailed information look at technical reference manuals and application notes of the products. 9

ABB Oy Distribution Automation P.O. Box 699 FI-65101 Vaasa FINLAND Tel. +358 10 22 11 Fax. +358 10 224 1094 www.abb.com/substationautomation 1MRS756412 EN 08.2007