PCB Trace Impedance: Impact of Localized PCB Copper Density

Similar documents
Design Guide for High-Speed Controlled Impedance Circuit Boards

Making Sense of Laminate Dielectric Properties By Michael J. Gay and Richard Pangier Isola

The Effects of PCB Fabrication on High-Frequency Electrical Performance

Controlled Impedance. An introduction to the Manufacture of Controlled Impedance P.C.B. s

TOLERANCE FORGOTTEN: IMPACTS OF TODAY S COMPONENT PACKAGING AND COPPER ROUTING ON ELECTRONIC

Impedance-Controlled Routing. Contents

Matched Length Matched Delay

Multilayer PCB Stackup Planning

Plane Crazy, Part 2 BEYOND DESIGN. by Barry Olney

Intel 82566/82562V Layout Checklist (version 1.0)

The Effects of PCB Fabrication on High-Frequency Electrical Performance

polarinstruments.com

PCB Routing Guidelines for Signal Integrity and Power Integrity

Integrated stackup design for PCB fabricators and OEM designers

Signal Integrity

How to anticipate Signal Integrity Issues: Improve my Channel Simulation by using Electromagnetic based model

Generic Multilayer Specifications for Rigid PCB s

Vol. 58 No. 7. July MVP NI AWR Design Environment. Founded in 1958

Nan Ya Plastics Corp.

Controlled Impedance Test

DESIGN FOR MANUFACTURABILITY (DFM)

Overcoming the Challenges of HDI Design

25Gb/s Ethernet Channel Design in Context:

Impact of etch factor on characteristic impedance, crosstalk and board density

Controlled Impedance Line Designer

PCB Material Selection for High-speed Digital Designs. Add a subtitle

Additional Trace Losses due to Glass-Weave Periodic Loading

Differential Pair Routing

Novel Packaging Approaches for Miniature Antennas

DL-150 The Ten Habits of Highly Successful Designers. or Design for Speed: A Designer s Survival Guide to Signal Integrity

IT STARTS WITH THE DESIGN: THE CHALLENGE: THE PROBLEM: Page 1

Split Planes in Multilayer PCBs

PI3HDMIxxx 4-Layer PCB Layout Guideline for HDMI Products

MICTOR. High-Speed Stacking Connector

Michael R. Creeden CEO/CID+ San Diego PCB, Inc. & EPTAC (858)

HOW SMALL PCB DESIGN TEAMS CAN SOLVE HIGH-SPEED DESIGN CHALLENGES WITH DESIGN RULE CHECKING MENTOR GRAPHICS

FPGA World Conference Stockholm 08 September John Steinar Johnsen -Josse- Senior Technical Advisor

Microcircuit Electrical Issues

Stencil Design Considerations to Improve Drop Test Performance

Adjusting Signal Timing (Part 1)

CAPABILITIES Specifications Vary By Manufacturing Locations

Mini Modules Castellation Pin Layout Guidelines - For External Antenna

Cost-minimized Double Die DRAM Packaging for Ultra-High Performance DDR3 and DDR4 Multi-Rank Server DIMMs

Silicon Interposers enable high performance capacitors

The number of layers The number and types of planes (power and/or ground) The ordering or sequence of the layers The spacing between the layers

Essential Thermal Mechanical Concepts Needed in Today s Microwave Circuit Designs. John Coonrod, Nov. 13 th, 2014

High-Speed Circuit Board Signal Integrity

Chapter 16 PCB Layout and Stackup

Practical Limitations of State of the Art Passive Printed Circuit Board Power Delivery Networks for High Performance Compute Systems

South Bay Circuits. Manufacturability Guidelines. Printed Circuit Boards FOR. South Bay Circuits, Inc. 99 N. McKemy Ave Chandler, AZ 85226

DL-150 The Ten Habits of Highly Successful Designers. or Design for Speed: A Designer s Survival Guide to Signal Integrity

Application Bulletin 240

PI3DPX1207B Layout Guideline. Table of Contents. 1 Layout Design Guideline Power and GROUND High-speed Signal Routing...

Magnetics Design. Specification, Performance and Economics

Understanding the Effect of Process Changes and Flux Chemistry on Mid-Chip Solder Balling

EQUIVALENT THROAT TECHNOLOGY

Effect of Power Noise on Multi-Gigabit Serial Links

S-Parameter Correlation

Overcoming Obstacles to Closing Timing for DDR and Beyond. John Ellis Sr. Staff R&D Engineer Synopsys, Inc.

INFLUENCE OF PCB SURFACE FEATURES ON BGA ASSEMBLY YIELD

PCB Dielectric Material Selection and Fiber Weave Effect on High-Speed Channel Routing. Introduction

Quantitative Evaluation of New SMT Stencil Materials

Enabling Parallel Testing at Sort for High Power Products

Hardware Design Considerations for MKW41Z/31Z/21Z BLE and IEEE Device

Characterization of Printed Circuit Board Material & Manufacturing Technology for High Frequency

AN 766: Intel Stratix 10 Devices, High Speed Signal Interface Layout Design Guideline

CHAPTER 5 PRINTED FLARED DIPOLE ANTENNA

Section VI. PCB Layout Guidelines

ALTIUM LIVE 2018: PRACTICAL HIGH-SPEED DESIGN CONSTRAINTS. Randy Clemmons CID+ San Diego PCB October 5, 2018

Shielding effects of Coplanar Waveguide over Ground

Improve SMT Assembly Yields Using Root Cause Analysis in Stencil Design

DDR4 memory interface: Solving PCB design challenges

Improve SMT Assembly Yields Using Root Cause Analysis in Stencil Design

Flip-Chip PBGA Package ConstructionÑ Assembly and Board-Level Reliability

Application Note 58 Crystal Considerations with Dallas Real Time Clocks

INTRODUCTION THEORY. Formulas:

High-Speed Digital System Design Fall Semester. Naehyuck Chang Dept. of EECS/CSE Seoul National University

The design of Ruthroff broadband voltage transformers M. Ehrenfried G8JNJ

3. Details on microwave PCB-materials like {ε r } etc. can be found in the Internet with Google for example: microwave laminates comparison.

WIRE LAYING METHODS AS AN ALTERNATIVE TO MULTILAYER PCB Sf

What the Designer needs to know

Effective Routing of Multiple Loads

Texas Instruments DisplayPort Design Guide

NextGIn( Connec&on'to'the'Next'Level' Application note // DRAFT Fan-out 0,50mm stapitch BGA using VeCS. Joan Tourné NextGIn Technology BV

Low-Cost PCB Design 1

FAQ: Microwave PCB Materials

Approach for Probe Card PCB

Vol. 55 No. 7. Founded in 1958 mwjournal.com. July 2012

Improve SMT Assembly Yields Using Root Cause Analysis in Stencil Design

On the Road to 5G Advances in Enabling Technology: A Materials Perspective

CROSSTALK DUE TO PERIODIC PLANE CUTOUTS. Jason R. Miller, Gustavo Blando, Istvan Novak Sun Microsystems

Engineering White Paper The Low Mass Solution to 0402 Tombstoning

A range of techniques has been devised to quantify the amount of misregistration present in a laminated panel:

METRIC PITCH BGA AND MICRO BGA ROUTING SOLUTIONS

User2User The 2007 Mentor Graphics International User Conference

Trends in RF/Microwave & High Speed Digital and their effect on PCB Technology Requirements

Virtual Access Technique Extends Test Coverage on PCB Assemblies

Intro. to PDN Planning PCB Stackup Technology Series

New Materials and Method for Laser Trimmable NTC Thermistors

TCLAD: TOOLS FOR AN OPTIMAL DESIGN

Transcription:

PCB Trace Impedance: Impact of Localized PCB Copper Density Gary A. Brist, Jeff Krieger, Dan Willis Intel Corp Hillsboro, OR Abstract Trace impedances are specified and controlled on PCBs as their nominal impedance value and variations are key factors in establishing system I/O bus performance. PCB trace impedances are evaluated and controlled during manufacturing using impedance coupon structures. An issue critical to many high performance I/O busses is that the actual bus impedance is shifted and the intra-bus variation is larger than measured using the impedance coupons, leading to PCB motherboards being Out of Specification. Recent work has shown that shifts in measured impedances across a PCB layer is correlated to localized changes in copper density within the PCB fabrication panel due to both the motherboard design and the PCB manufacture s selection of fill pattern and impedance coupon location. Managing the copper density across the fabrication panel through proper coupon design, placement, and copper fill pattern selection is required to minimize impedance shifts between coupons and product. This paper highlights the impact of copper density on PCB trace impedances and provides a BKM (Best Known Method) for managing copper density and designing impedance coupons to minimize impedance shifts and variations that otherwise could lead to Out of Specification impedances on PCB motherboards. Introduction Copper density and copper density transitions drive changes in trace impedance by altering the dielectric thickness and electrical properties of traces. The impact of copper density transitions have also been shown to extend to adjacent layers of the PCB. As a result, localized copper density and copper density transitions must be managed within both the design and the fabrication panel. Recent desktop designs implemented a Partial POOL (Planes On Outer Layer) structure on the PCB motherboard for DDR bus Channel B to improve signal margins at equivalent bus lengths and routing rules. The Partial POOL structure as implemented in a four layer PCB inset the DDR channel B routing into the Layer 3 plane and placed the DDR reference plane on the Layer 4 outerlayer. This resulted in a localized region of low copper density on Layer 3. During the test board builds, two issues were discovered within the Partial POOL DDR implementation. First, the trace impedances near the center of the Partial POOL DDR region were notably lower than impedances at edge of the region as shown in Figure 1. Secondly, a significant impedance offset was observed between the impedance coupons used by fabricators to select line widths and the impedance values across the DDR Channels. +5 Ohms 0 5 +5 Ohms 0 Standard ustrip (Layer 1) Microstrip traces Hi Z MB Left DDR Channel Right Coupon Impedances Partial POOL (Layer 3) : Low Z MB Hi Z MB : Low Z MB 5 Transition Center of Void Transition Region Region Partial POOL traces Figure Error! No text of specified style in document. - Intra-channel Impedance Variation across Multiple Motherboards Measured impedance of DDR data signals at the center of the Partial POOL DDR Channel B extended ~3-5 ohms lower than measured DDR data signal impedances at edge of the routing channel. The measured decrease was significant in that the 3-5ohm increase in intra-bus variation consumed roughly 50% of the allowable impedance tolerance for 40ohm +/-15% DDR signals. The measured change in variation exceeded the modeled intra-bus variation and required Signal Integrity engineers to update simulation models for the DDR channels. Conversely, measured impedances within the Layer 1 microstrip DDR Channel A generally followed trends measured on previous platform builds and had both low intra channel impedance range and expected board to board variation. Investigation across multiple OEM motherboards that implemented Partial POOL as well as internally purchased PCBs built at different fabricators with various materials showed that all designs which implemented Partial POOL had a similar impedance profile

within the Partial POOL region. Final analysis showed that copper density variations within the PCB fabrication panel corresponded to changes in the dielectric thickness profile across the Partial POOL region and thus altered impedances. Secondly, Impedance offset between the impedance coupon and the DDR channel induced an impedance shift as fabricators controlled the line widths based on measurements from their standard coupon layouts. Figure 1 shows the measured impedances across the DDR regions with the manufacturing coupons impedances for each panel highlighted by the rectangle on right of each impedance plot. The coupon impedances for Partial POOL DDR were closely matched to the impedances at the edge of the Partial POOL DDR region; but, there was a marked offset to impedances at Center of Void. The Center of Void offset was of special concern as the DDR address, control, clock and command traces were fully located at center of DDR region and were thus shifted toward the low impedance corner with some individual traces out of specification. In addition, the impedances within Layer 1 microstrip DDR regions were also shifted and measured slightly higher than the coupon. The differences between the impedance coupon and the DDR channel was found to result from variations in the copper density across the manufacturing panel due to the motherboard layout, impedance coupon location and design, and the fill pattern selected by PCB fabricator. During analysis, it was discovered that a high to low copper density transition within the Layer 3 Partial POOL DDR region correlated to an increase in the nominal dielectric thickness between Layer 1 and Layer 2, resulting in the increased Layer 1 microstrip DDR bus impedance. The result of the Partial POOL DDR implementation highlighted the impact of copper density variations on PCB dielectric thicknesses and impedances. Signal Integrity Engineers need to evaluate designs for copper density variations and may need to account for higher variations in modeling and simulations. It was also found that local copper density variations on a single layer affect the impedances and dielectric thicknesses on multiple layers. While the correlation between copper density and dielectric thickness variations can be incorporated into electrical simulations, it is very important that proper design and procurement methods are followed to minimize inherent impedance offsets within procured motherboards. Copper Density Impact on Local Trace Embedding The Partial POOL structure, as implemented in a four layer motherboard, utilized a portion of the Layer 3 PCB plane for DDR memory signal routing as shown in Figure 2, and placed the reference plane for these signals on the Layer 4 external PCB layer as shown in Figure 3. Layer 2 was a plane and Layer 1 used for signaling. The PCB core and prepreg material selection for the Partial POOL design was the same as a traditional four layer microstrip PCB design which consisted of 1080 prepreg between Layer 1 and Layer 2, 49mil core between Layer 2 and Layer 3, and 1080 prepreg between Layer 3 and Layer 4. This maintained desired z-axis symmetry and uniform dielectric thicknesses for all microstrip IO interfaces in both the traditional microstrip design and Partial POOL implementation. Trace embedding within the Partial POOL region results from the redistribution of prepreg material around lower copper density signal traces during lamination at high pressure and elevated temperature. In typical glass reinforced PCB dielectrics, local changes in thickness correspond to changes in its glass to resin ratio which influence the localized dielectric properties. In traditional Layer 4 microstrip routing, the dielectric thickness between the Layer 4 signals and the Layer 3 reference plane is fairly consistent across the DDR region. During the lamination process, the Layer 3 reference plane of a traditional design has a high copper density which is uniform across the entire image and the Layer 4 copper is an un-etched copper layer. As a result, the prepreg dielectric between Layer 4 and Layer 3 is essentially laminated between two solid copper planes providing a uniform dielectric thickness for traditional Layer 4 microstrip routing. However, within a Partial POOL design Layer 3 has a high copper density except within the DDR routing region where the copper density drops significantly. During lamination, the dielectric core of the PCB bends and the prepreg epoxy materials move to fill the void created by the low copper density, altering the dielectric thickness within the DDR region. The implementation of Partial in the DDR subsection highlighted the dielectric and impedance impacts of copper density. Traces Typical Zo Data/Cntrl 40 ohm CMD/ADDR 32 ohm CLK 62 ohm Figure 2 - Representative Layer 3 Artwork for DDR Partial POOL

Reference plane for Layer 3 signal Figure 3 - Representative Layer 4 Artwork for DDR Partial POOL The boundary between the copper plane and the DDR routing areas on Layer 3 is referred to as the Edge of Void (EoV). Figure 4 shows a representative DDR bus layout on Layer 3. At the EoV, the copper density changes from greater than 90% in the plane region to less than 30% copper in the DDR data area. The copper density in the DDR CMD/ADDR region is approximately 40% which is slightly higher than in the DDR data region. In a common 4 layer microstrip PCB stackup, the dielectric thickness between the outer layers and reference plane in PCBs using 1080 style prepreg is typically 2.7 mils. While the nominal value may vary slightly between suppliers and FR4 resin systems, the thickness variation across an individual motherboard layer is typically within +/-0.2 mils. High copper density: typically >90% Low copper density: 20-30% Edge of Void / boundary of Partial POOL routing region Data region CMD/ADDR/CLK region Data region Figure 4 - Copper Density Change at Edge of Void In a Partial POOL design, the dielectric thickness in the plane region away from the DDR channel was as expected at a typical 2.7 mils using 1080 prepreg. However, near the boundary of the Partial POOL region there was a transition region where the dielectric thickness started decreasing. The dielectric thickness decreased to a minimum which was maintained across the internal portion of the DDR routing channel. The region where the dielectric thickness was at a minimum is referred to as the Center of Void (CoV) as illustrated in Figure 5 Plane region Transition region Center of Void region Edge of Void Figure 5 - Typical Shape to Trace Embedding Regions

Cutline for Cross-section mils Cutline for Cross-section mils mils As originally published in the IPC APEX EXPO Proceedings. Measured profiles from several OEM PCBs are shown in Figure 6. Based on cross-section analysis across multiple FR4 and HF-FR4 resin systems and multiple PCB fabricators, the measured transition region for Partial POOL DDR started approximately 0.3-0.4 before the EoV and extended approximately 0.5 toward the CoV. The majority of the trace embedding and dielectric height reduction occurred within 0.25 of the EoV. The width of the transition region will vary by multiple factors including size and shape of the Void region, material properties, and lamination process conditions. The 40 ohm Data traces for the DDR channel are within this transition region. The traces nearest the EoV had the highest impedances and highest level of crosstalk as the dielectric thickness is greatest along the EoV. Based on simulation data, it was important that the impedance coupon traces for the Data traces represents the EoV condition which represented the thickest dielectric condition within the DDR region. 3.5 3 Dh (mils) across Cutline: OEM A 3 Dh (mils) across Cutline: OEM C 2.5 2.5 2 1.5 1 0.5 0 Lyr 1-2 Dh Lyr 3-4 Dh partial POOL region partial POOL region 2 1.5 1 0.5 DDR Region No Partial POOL Lyr1-2 Dh Lyr3-4 Dh 0 3.5 3 2.5 2 1.5 1 0.5 0 Dh (mils) across Cutline: OEM B Lyr1-2 Dh Lyr3-4 Dh Partial POOL region Figure 6 - Dielectric Height Profile across the Partial POOL DDR Layer The minimum dielectric thickness within the CoV region was typically 2.0 to 2.2 mils for the single ply 1080 stackups. In general, this value would be affected by material selection, stackup, and lamination process used by the PCB fabricator. Each type of PCB material using glass fabric reinforcement has a minimum Glass Stop thickness to which the glass fabric can be compressed. A typical 1080 style prepreg has a glass stop thickness between 2.0-2.2 mils based on IPC woven glass thickness specifications.[1] A secondary factor that limits the amount of dielectric thickness change in the Partial POOL region is the copper thickness. Trace embedding will only extend to the point that pressures are normalized during the lamination process. The transition in dielectric thickness from EoV region at ~2.7mil to the CoV region at 2.0-2.2mils resulted from design, was repeatable and therefore was incorporated in DDR simulation models. Any design which contains similar copper density transitions, such as placing signals on plane layers or placing large power shapes on signal layers, should also incorporate the added variations into their simulation models. The magnitude of the dielectric height change and width of the transition region will depend on stackup, design, and material selection. Copper Density Impact on Adjacent Layers Validation boards from 5 OEMs were measured to assess impact of the copper density across multiple PCB fabricators and PCB materials. Four OEMs implemented Partial POOL DDR design and one OEM used standard microstrip DDR routing. Figure 6 shows the measured dielectric thickness profiles obtained through cross-section measurements for three of the OEM motherboards. Each motherboard that implemented Partial POOL exhibited the expected reduced dielectric thickness within the DDR region corresponding to the reduced copper density on Layer 3. The OEM, labeled OEM C in Figure 6, which utilized the standard microstrip DDR routing, exhibited a uniform dielectric thickness across the DDR region as expected for a design with uniform copper density on Layer 3. In many cases, the thickness measurements decreased near the motherboard edges, see Figure 6 OEM C. Later test panels would reveal this to be associated with copper density of fill patterns used by PCB fabricators outside and adjacent to the image.

The Layer 1-2 dielectric thickness within the DDR region was also impacted by the change in Layer 3 copper density. Within the Partial POOL DDR region, as the Layer 3-4 dielectric thickness decreased due to low copper density in the DDR region of Layer 3, the dielectric thickness at Layer 1-2 increased; but, at a lesser extent. The increase in Layer 1-2 dielectric thickness corresponded to increased impedance values measured within the Layer 1 microstrip DDR region. Preliminary cross-section data indicated that part of the change in the Layer 3-4 and Layer 1-2 dielectric thickness was due to the dielectric core between Layer 2-3 bending toward the Layer 4 plane. While further work is needed to model the core bending in response to layer to layer copper density changes in PCBs, the initial result is significant in that it highlights the linkage between the transition region width and the mechanical properties of the core. Also, a difference in core thicknesses such as found between thick cores used in desktop PCBs and thinner cores used in higher layer server product should produce different responses. The change in dielectric thickness due to the copper density resulted in a miscorrelation of DDR bus impedances to the manufacturing impedance coupon. As measured from validation boards, the EoV DDR traces were close in value to the measured manufacturing coupon impedance; but, the 40ohm single-ended impedances at CoV were shifted lower by 3-5ohms or 7.5-12.5%. In addition, the increase in Layer1-2 dielectric thickness shifted the nominal DDR bus impedances on Layer 1 up by ~2-3 ohms or 5-7%. As it is impractical to artificially change the impedance specification value on the PCB drawing in expectation that the measured values will always be shifted a set amount, an impedance coupon was designed to mimic the Partial POOL DDR behavior and minimize the impedance offset between the manufacturing impedance coupon and motherboard impedances. Impedance Coupon Design to Minimize Impedance Offsets Test boards were built to investigate methods of minimizing the impedance offset measured between manufacturing coupons and the DDR impedances on the PCB motherboard. A typical PCB manufacturing panel, as shown in Figure 7, contains multiple areas, some controlled by the motherboard designer and others by the PCB fabricator. Based on previous measurements it was determined that the impedance offset between the coupon and motherboard impedance could be best minimized by better matching the dielectric thickness within the coupon with the appropriate motherboard region. Three factors were considered essential. One, the coupon design would need to match the copper density of the IO bus structure it represented and be wide enough to contain a full dielectric height transition region on either side of traces when representing Center of Void region impedances. Two, the copper density of fill patterns used by the PCB fabricator would need to match that of the motherboard layer at each layer. Three, the position of the coupon within the manufacturing panel would need to be placed in such a way to avoid significant shifts in copper density such as at panel edges, router paths, or other panel features that could not easily be modified. Using the three factors, test boards were fabricated at five high volume PCB suppliers using the 4 layer Partial POOL design. All suppliers placed two Partial POOL motherboard designs within a manufacturing panel, controlled the copper fill by layer, and placed both an Intel designed coupon in addition to their standard coupon design around the panel and between the two motherboard images. Test Board Results Typical cross-section measurements of the Layer 1-2 and Layer 3-4 dielectric thicknesses profiles from the test boards are shown in Figure 8 and Figure 9. Across all suppliers, the optimized coupon at center of panel best minimized the difference in dielectric thickness at its center compared to the thickness at the Center of Void within the Partial POOL DDR region. The optimized coupon enabled tracking of both Edge of Void and Center of Void DDR impedance values by simply placing the coupon impedance trace at either the edge or center of the coupon respectively. Coupons within 0.5-0.75 inch of the edge of manufacturing panel were not well behaved as the dielectric thickness across the coupon trended lower when approaching the manufacturing panel edge. As dielectric thickness decreased near panel edges, traces on either side of the manufacturing coupon would produce different impedances. The panel edge behavior was evident in both the Intel provided coupon design and coupon design supplied by the PCB fabricator.

3 2.5 2 1.5 1 0.5 0 3.5 3 2.5 2 1.5 1 0.5 0 Supplier Coupon at center 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 Intel Coupon at center 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Series1 Series2 Series2 Series3 As originally published in the IPC APEX EXPO Proceedings. Figure 7 - Typical Manufacturing Panel The optimized coupon design at the center of panel proved to better represent the Partial POOL region than the supplier designed coupons. Supplier provided coupons resulted in dielectric thickness differences compared to the Partial POOL DDR region. The coupon design by Supplier A and placed at center, shown in Figure 8, used a pattern that better approximated a plane and thus did not account for the low copper density within the Partial POOL DDR region. The Supplier A coupon resulted in no measureable trace embedding and a dielectric thickness 35-40% thicker (~2.8mils vs 2.0mils) than measured within the DDR region of the motherboard. The coupon designed by Supplier B and located at center of panel, shown in Figure 9, did not provide sufficient width for transition to achieve full trace embedding and resulted in a dielectric thickness approx 10% thicker (2.65mils vs 2.4mils) than measured within the DDR region of the motherboard. The optimized impedance coupon which controlled the coupon width, placement of traces within the coupon, and copper density was found to minimize dielectric thickness offsets between the coupon and the motherboard. The optimized coupon placed at center, shown at right-hand side of Figure 8 and Figure 9, achieved dielectric thickness less than 0.10mil delta from the average dielectric thickness in the motherboard CoV region and EoV region. It should be noted that when placed at the edge of a manufacturing panel, non-optimized coupons would at times achieve similar dielectric thicknesses to that of the CoV DDR region as shown by the Supplier Coupon at Edge in Figure 9. The issue with coupons placed at edge of panel was that the traces on opposing sides of the coupon behaved differently. The traces closest to manufacturing panel edge had a lower dielectric thickness compared to traces closer to the center. Coupons placed between the Partial POOL motherboards and toward center of the manufacturing panel exhibited best center to edge symmetry. Fabrication Panel thickness measurements from Cross-section Dielectric Thickness in mils 3.5 3 2.5 Supplier Coupon at Edge Intel Coupon at Edge 2 1.5 Layer 1 Layer 4 Partial POOL Figure 8 - Supplier A Impedance Coupon Test Board Results

4 3 2 1 0 4 3 2 1 0 Incorrect fill and excessively wide route paths were also shown to impact coupon behavior. Supplier A failed to place correct copper fill next to the optimized coupon at center of panel as shown in Figure 8. While this coupon achieved the targeted thickness for the DDR Center of Void region, the fill pattern resulted in a premature transition of the dielectric thickness at edge of the impedance coupon. Thus, the dielectric height for the trace at the edge of the coupon was thinner than the dielectric thicknesses of the traces it represented at edge of the DDR transition region in the motherboard. Copper Density BKM for Impedance Coupon The optimized impedance coupon design BKM (Best Known Method) developed from the test board encompasses several key learning s. As it will not always be practical to implement each of the learning s, they should be prioritized to minimize impedance offsets on most critical bus impedances. Balance the copper density within the impedance coupon to reflect the motherboard copper density. Maintaining similar copper density was important to minimize the dielectric thickness difference between the coupon and the IO regions of the motherboard. Copper density on internal layers impacted the amount of trace embedding and final dielectric thickness. Example of copper fill using dummy traces to match the DDR channel for Partial POOL motherboards is shown in Figure 10. Managing external layer copper density was also essential. While external layer copper density does not impact dielectric thickness, it has been shown to correlate to conductor thickness due to the relationship between copper density and copper deposition rates during the copper plating process [2] Impedance traces should be placed within the coupon in a manner that best represents their placement within the motherboard, when possible. On layers with significant changes in copper density, the coupon should be designed with sufficient width to induce proper change in trace embedding and the coupon trace should be placed at position to represents its critical condition. For example, in the Partial POOL DDR design, the 40 ohm single-ended impedance trace on Layer 3 was placed nearest the impedance coupon edge as the design team deemed this position the critical position based on simulation. Conversely, the 62ohm and 32ohm CLK/CMD/ADDR coupon traces were placed at center of coupon and coupon width was set at minimum 1.0inch. See Figure 10. This placement of the impedance traces and selection of the coupon width was determined from the measured transition width. Ensuring sufficient coupon width was critical in correlating the impedance coupon with the impedance values of DDR data traces at the Center of Void region by ensuring that the coupon traces experienced highest trace embedding and thinnest dielectric within the coupon. Layer3 Copper pattern vs Fabrication Panel thickness measurements in mils 3.5 2.5 1.5 0.5 Series1 Series2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 Series1 Series2 Supplier Coupon at center Intel Coupon at center As originally published in the IPC APEX EXPO Proceedings. 3.6 3.4 Supplier Coupon at Edge 3.2 3 2.8 2.6 2.4 2.2 2 Layer 1 Layer 4 Partial POOL Intel Coupon at Edge 3.5 2.5 1.5 0.5 Figure 9 - Supplier B Impedance Coupon Test Board Results The preferred impedance coupon placement is at the center of the manufacturing panel as shown in Figure 11. The center of the manufacturing panel minimizes the deviations of dielectric thickness variations due to panel edge and border coupons. The center of the manufacturing panel also provided best location to obtain plating thickness uniformity and the minimize line width offsets seen near the edge of the manufacturing panel.

Edge of Void Min 0.4 Dummy traces: 5 mil traces on 25 mil centers Center of Void 62 ohm differential CLK 32 ohm CMD/ADDR CMD/ADDR and CLK impedance traces Edge of Void Coupon edge nearest board image Min 0.4 40 ohm single-ended for DDR data Max 20 mil gap to copper fill Figure 10 - Coupon Design for Partial POOL DDR 15-20 mil gap either side of impedance trace 40 ohm SE for DDR Data, nearest Edge of Void Impedance coupons should be placed along the edge of the manufacturing panel only if it is not possible to place the impedance coupons at the center of the manufacturing panel. Placing an impedance coupon closer than 0.75 of manufacturing panel edge should be avoided as the dielectric thickness close to the panel perimeter is often reduced during the lamination process and will not reflect the dielectric thickness within the image. When placing the impedance coupon along an edge, it is preferred to select a location that provides the greatest distance from any fabrication panel edges to minimize dielectric thickness variations. Typically, coupons placed along the trailing-leading edges also exhibited additional plating variation as these edges were most often oriented at the top or the bottom in the plating bath. Because of manufacturing and process differences between PCB suppliers, it is recommended that motherboard designers consult with their specific PCB suppliers to determine the best location for the impedance coupons if the coupons cannot be placed at or near the center of the manufacturing panel. Figure 11 - BKM Placement of Impedance coupons Fill pattern: Typical shape is 100 mil circles on 125-150 mil centers Fill pattern: Typical shape is 235x235 mil on 250 mil centers Figure 12 - Representative Fill Patterns for Signal Layers and Plane Layers Avoid gaps between the motherboard image and impedance coupon that significantly change the copper density. For example, to maintain high copper density between the image and the impedance coupon on Layer 3 Partial POOL layer, the router gap was minimized by placing the manufacturing coupon as close as possible to the motherboard image. Large gaps between the image and coupon should be avoided as the fill pattern combined with router gaps typically do not achieve proper copper density, see Figure 11. Instruct the PCB fabricator to adjust fill patterns to match typical copper density for each layer. Signal Layers will typically have copper density between 15-50% and plane layers have copper density between 80-90%. Many suppliers utilize a fill pattern that is close to 50% copper and utilize that pattern for all layers. While this may be adequate for signal layers, the fill pattern for plane layers should be modified to achieve 80-90% copper density. The Partial POOL testing used larger fill shapes at 235x235mils on 250mil centers as shown in Figure 12 for plane layers.

Summary Designers and Signal Integrity engineers need to be aware of copper density issues that impact the impedance and electrical properties of critical signals. Designers need to understand that it is best to minimize copper density variations across a PCB layer and that large variation in copper density will increase the magnitude of impedance variations within a design, lead to potential impedance shifts away from targeted values, and potentially impact the electrical properties and impedances on other layers of the PCB. These issues have been demonstrated to occur when using plane layers for IO routing such as Partial POOL designs and are expected to also occur when using large fill shapes for power delivery on signal layers. While not measured as part of this work, the dielectric constant and dielectric loss properties are also be impacted by changes in copper density as any change in the dielectric height with the same glass fabric changes the glass to resin ratio and hence changes the electrical properties. Minimizing impedance offsets within fabricated PCB motherboards requires not only good design practices; but also requires management of the impedance coupon design and the fill patterns used by the PCB fabricator. Traditionally, PCB fabricators design impedance coupons, select coupon placement, and add fill patterns without consideration for how these influence electrical variations or represent the location of critical signals within the design. The method provided in this paper is a good starting point when working with PCB fabricators and minimizing copper density issues affecting the correlation between impedance coupons and the motherboard impedances. Signal Integrity engineers still need to manage and include the added variations due to changes in copper density within simulation models. Additional work is required to generate models that predict the extent to which copper density alters the PCB dielectric properties of thickness, dielectric constant, and dielectric loss. As shown in this paper, copper density on one layer affects multiple layers. Surprisingly, the local change in copper density within the Partial POOL design resulted in distortion of very thick cores, additional effort is also needed to quantify the width and magnitude of the transition region in alternate PCB constructions such as higher layer server product that utilize thinner dielectric cores. References [1] IPC-4412, Specification for Finished Fabric Woven from E Glass for Printed Boards, June 2002 [2] Coombs, Clyde F., Printed Circuits Handbook Sixth Edition, 2008

PCB Trace Impedance: Impact of Localized PCB Copper Density Gary Brist Intel Corp

Purpose Describe copper density impact on PCB trace impedances Highlight design considerations related to copper density

Agenda Design Example: Partial POOL PCB PCB structural behavior affecting impedance Impedance coupon considerations Call to Action

Design Example Partial POOL (Plane On Outer Layer) Reference Plane on outerlayer, Signals Inset in plane layer Enabled stripline DDR Channel B Issue: Increased intra-bus impedance variance 50 45 40 DDR Channel B Impedances Standard ustrip Partial POOL Implementation ~3-5ohms Typical Impedance Coupon Layer 4 Partial POOL in DDR region 35 Left DDR Channel Right

Design Example Impedance related to proximity of copper density transitions Issue: Ensure correct impedance tracked during fabrication 50 45 40 35 Partial POOL Channel B Impedances Typical PCB High-Z PCB Low-Z PCB Transition Center of Void Transition Region Region Region High density: typically >90% Low density: 20-30% Medium density: 40-50%

Agenda Design Example: Partial POOL PCB PCB structural behavior affecting impedance Impedance coupon considerations Call to Action

As originally published in the IPC APEX EXPO Proceedings. Dielectric Thickness Partial POOL 4Lyr PCB Thickness reduced by ~2025% for signals inset onto layer 3 plane Partial POOL Region Impact on adjacent layers Lyr 1-2 response across 49mil core

Dielectric Er Dielectric constant varies with layer thickness Glass has higher (1.5-1.8x) Er than resin Thinner dielectric => Less resin and higher Er

Impedance Coupon Challenge Impedance shift at Center of Void set by design Coupon design must mimic Partial POOL region CMD/ADDR/CLK at center of void - always shifted low Max DDR byte lane impedance swing at edge of transition region Center of Void Transition Region Data region Data region CMD/ADDR/CLK

Agenda Design Example: Partial POOL PCB PCB structural behavior affecting impedance Impedance coupon considerations Call to Action

Zo Coupon Design Considerations Impedance coupon attributes typically controlled by PCB fabricator Typical PCB Manufacturing Panel Copper density Trace placement Coupon location Image Panel Fill Border Design Impedance Coupon Manufacturing Coupons

Impedance Coupon Design Copper density control Must match IO bus density Std Coupon Cross-section line Optimized Coupon Optimized coupon achieves dielectric height mils 3.5 3 2.5 2 Layer 1-2 Dh 100 75 50 % 1.5 1 Layer3-4 Dh Partial POOL Layer 3 Copper Density 25 0 Dielectric Height vs Copper Density across fabrication panel

Impedance Coupon Design Trace placement selected to match IO bus region Center of coupon used for CMD/ADDR/CLK Edge traces used to reflect max impedance for Data mils Optimized coupon Dielectric Height 3.5 Layer 1-2 3 2.5 2 Layer 3-4 Partial POOL Center Void Ave Thickness Crosssection line

Impedance Coupon Design Width of Coupon critical Cross-section line Narrow voids limit thickness transition Narrow voids result in impedance coupon shift mils 3.5 3 2.5 2 Layer 1-2 Layer 3-4 Partial POOL Center Void Ave Thickness Narrow Coupon Dielectric Height

Impedance Coupon Placement Placement affects dielectric thickness Dielectric height reduced at panel edges Best coupon placement at center of the manufacturing panel mils Cross-section line 3.5 3 mils 2.5 2 0 100 80 60 40 20 Layer 1-2 Dh Layer 3-4 Dh Layer 3 Copper Density Layer 1-2 Dh typical Dielectric Height across fabrication panel %

As originally published in the IPC APEX EXPO Proceedings. Impedance Coupon on Plated Layers Copper density impacts plated trace thickness Impacts deposition rate Coupon needs to match density of target bus area. Coupon: Low Cu Density Thickness 2.4-2.6mils Image: Mid Cu Density Thickness 1.65+/-.1 mils Image: Cu Fill/Plane Thickness 1.4-1.5mils Copper Thickness post Pattern Plating of PCB

Agenda Design Example: Partial POOL PCB PCB structural behavior affecting impedance Impedance coupon considerations Call to Action

Call to Action Impedance coupons must be optimized for copper density, panel placement and trace location to prevent systematic impedance shift with respect to the IO bus Copper density transitions impact impedances on multiplelayersandmustbeconsideredinallpcb designs. Power shapes on signal layers, isolated busses, plane splits, etc are potential sources of copper density transitions that impact impedances

Q&A