LT3000 ULTRASONIC LEVEL TRANSMITTER

Similar documents
LPU-2127 User Manual

2-wire level transmitter

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

EchoSonic II Ultrasonic Level Transmitter LU23, LU28 & LU29 Series Quick Start NEMA 4X Enclosure

EchoSonic II Ultrasonic Level Transmitter LU27 Series Quick Start NEMA 4X Enclosure

FCC ID: SAGA1-L8 IC: 2802A-SAGAL8 CE0470

742A Series Resistance Standards

COMMERCIAL TRANSMITTER INSTRUCTIONS

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

WS-7212NU Wireless 433 MHz Weather Station. Instruction Manual

Ricochet Alphasonic Level Transmitter Model LA15/20 Owner s Manual

Model 935A. Dual Tone Sender INSTRUCTION MANUAL

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

AIU-2 Installation Manual

American Power Design, Inc.

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION

EchoSonic II Manual 09 JUL 08 Revision A

Directed Energy, Inc Oakridge Dr., Suite 100, Fort Collins, CO

380 SERIES REPAIR PARTS INDEX. NOTE! Read and understand the pump and motor instructions before attempting to install, disassemble or repair the pump.

Field Hub Installation Guide. P/N Rev. C 05/15

Worldwide Manufacturer of Gas Detection Solutions. Transmitter EC 23. Operation Manual

POWER TRACE TM TASCO, INC.

THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC)

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

User s Guide Instructions for Installation and Operation

MiniMe 2-Wire Ultrasonic Level Transmitter Model LU12/LU13/LU14 Owner s Manual

Global Water Instrumentation, Inc.

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

Table of Contents. Safety Notices

M2/M2A AC-DC Power Supply Operator s Manual

305 Stimulus Isolator. Description

Instruction Manual. HB Series Mini Level Sensor

TARGETuner Antenna Management System for Screwdriver Antennas

SIR-WRR1. User's Guide SIRIUS Echo Antenna. Signal Repeater System Accessory

TRANSDUCER IN-LINE AMPLIFIER

PCO-7114 Laser Diode Driver Module Operation Manual

Radio Remote Controls Manual K Series

INSTALLATION GUIDE ET1551U. IP Video Camera Over Single Twisted Wire Ethernet Extender with EtherStretch. Description

AUTOMATION. Operator s Manual. IRU-2xx4/3xx4 Series. Rev. A2, 11/08 Doc

XPR522 XPR540. XPR SERIES INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

Explosion Proof Page/Talk Paging Amplifier

INSTRUCTION MANUAL. MODEL: Vintage 60R. Vintage Series Guitar Amplifi er

CS105 BAROMETRIC PRESSURE SENSOR

M2 Antenna Systems, Inc. Model No: S3 Sequencer. Operating Instructions

Digital Lighting Systems, Inc.

Balishutters. INSTALLATION guide FOR L-FRAME MOUNT INSTALL OPTIONS B OR C

FA401 Single Transmitter / Single Output Receiver. FA401R Single Transmitter / Single Relay Output Receiver. Installation Instructions 02305C

XPA2100 XPA4100 XPA6100. XPA SERIES INSTALLATION/OWNER S MANUAL Mobile Power Amplifiers

f i r e - p a r t s. c o m

Two Element Phased Vertical Array System

Instruction Manual Model M Switch, DPDT, Manual Select

Ricochet Alphasonic Level Transmitter Model LA15 Owner s Manual

Starbox. Installation guide

Echotel Model 910 Ultrasonic Level Switch

AMP-13 OPERATOR S MANUAL

500S Smart Antenna Installation and Operation Manual. P/N Rev. A 09/17 E29808

User s Guide TX92A. Miniature Temperature Transmitters. Shop online at omega.com

AM/FM+ OWNER S MANUAL

ARBE-III Instruction Manual

REMOTE SOIL MOISTURE MONITORING SYSTEM Installation Instructions

8 Channel, DMX to 0 10 volt, Decoder board

AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH

DA6002D-DA10004D. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

Kotron Sentinel Model 804 RF Level Transmitter

Video/Audio Transmission System Series VA700. (formerly Series DVL4A)

Series 3000 Model R-107A

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

30 Bending Brake. Model Assembly and Operating Instructions. Distributed exclusively by Harbor Freight Tools.

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL

XIA3145 INSTALLATION/OWNER S MANUAL 2/1-Channel Mobile Power Amplifier

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

Signal Isolation Module. Instruction Manual SIM

LL-105-R LED Dimmer & 0-10V Bridge Setup Guide

Inline Antenna Signal Amplifier

Staticmaster Model 6110 Air Assist Bar Ionizer

INSTALLATION GUIDE. Video Balun Transceiver with fixed BNC for twisted pair operation with other balun transceivers or active receivers.

American Power Design, Inc.

SC200 Series. Signal Conditioner MNX10020, REV H 10/17/ Connection Technology Center, Inc Rae Boulevard Victor, NY (585)

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

QuadroMAX. Installation Manual. QM Series. LED Outdoor Lighting Fixtures REV: 3/22/16

HTA125A/250A. Power Amplifiers. Installation & Use Manual

K-FACTOR SCALER B & B

Echotel Model 338 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow

Distribution Amplifiers 1

MICROTOOLS MICRONETBLINK KIT

HDTV Antenna. Contemporary Indoor. User s Guide

DA560D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

LINCO MEASUREMENT MODEL CP-2B MASTER METER PROVER COUNTER INSTRUCTION MANUAL

DIGITAL SOUND LEVEL DSM8930 METER USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

Kotron Sentinel Model 804 RF Level Transmitter

model 101 single channel microphone preamplifier owner s manual Rev C

Effective: June, 2000 EX-1821 Satellite Display Unit Receiver Installation Manual Models: 4643-*-* 4644-*-9 Since 1937

Global Water Instrumentation, Inc.

HT2 Humidity Transmitter HT2 Humidity and Temperature Transmitter Installation and Operating Instructions

C5000 & C5000NF PULSE INITIATOR. Introduction

TRANSDUCER IN-LINE AMPLIFIER

Installation guide 971 SmartRadar LTi

Propagation of Electromagnetic Waves

Trident Laundry Chemical Delivery System

Operating Manual. Model Channel. DC Signal Conditioner Amplifier

Transcription:

LT3000 ULTRASONIC LEVEL TRANSMITTER Owner s Manual Specifications Installation Calibration Troubleshooting Warranty Drawings Distributed By: iprocessmart.com 14262 Doolittle Drive San Leandro, CA 94577 Tel: (510) 352-8199 Fax: (510) 352-8897 E-Mail: sales@iprocessmart.com Revision 3; December 13, 2000 BABBITT INTERNATIONAL, INC. P.O. Box 70094 Houston, Texas 77270 (713) 467-4438

Table of Contents Specifications 2 Installation 3 Wiring 3 Selecting Loop Power Source 4 Calibration 4 Temperature Calibration 5 Error Codes 6 Troubleshooting 7 Drawings 9-11 Warranty 12 1

1. SPECIFICATION It is good engineering practice to use a separate, independent high level alarm with any continuous level transmitter. LEVEL MEASUREMENT DEVICE FOR LIQUID MATERIALS PRINCIPLE OF OPERATION: ULTRASONIC SONAR RANGE: 10" - 22' RESOLUTION: ACCURACY: TEMPERATURE: LOST ECHO HOLD TIME: TEMP.COMPEN.: OUTPUT: POWER SUPPLY: CALIBRATION: FUSE: SENSOR MOUNT.: CABLE ENTRY: HOUSING: +/-0.06% OR +/-0.12" (WHICHEVER GREATER), AT CONST.TEMP. & HUMIDITY, DRY AND STILL AIR +/-0.125% OR +/-0.25" (WHICHEVER GREATER), AT CONST.TEMP. & HUMIDITY, DRY AND STILL AIR -40F TO +140F (ELECTRONICS AND TRANSDUCER) 30 SECONDS YES (TEMPERATURE SENSOR INSIDE A TRANSDUCER) CURRENT LOOP 4.00mA - 20.00mA (<3.5mA ON ERROR), RESOLUTION 0.02Ma, 500 ohm MAXIMUM LOAD FACTORY WIRED - 115VAC/60Hz OR 230VAC/50Hz OR 24VDC (TOLERANCE=+/-20%) TWO-POINT SETTING, ONE PUSH-BUTTON, BI-COLOR LED STATUS INDICATOR. ASSIGNING HIGH AND LOW LEVELS AS 4 AND 20mA, OR 20 AND 4mA, RESPECTIVELY 0.125A/250V TYPE 2AG 2" NPT 1" NPT (CONDUIT) TRANSDUCER - PVC, HERMETICALLY SEALED ELECTRONICS - CAST ALUMINUM DESIGNED ACCORDING TO IEC1010 (GENERAL SAFETY) 2

2. PHYSICAL INSTALLATION The sensor should be installed on top of a tank pointing downwards, away from any inlet pipes, agitators and sources of mechanical vibrations. Entry for the supply and signal cables should be sealed against moisture by a conduit or by other means. Make sure that the power is off while wiring the cables and installing the boards. Note that only one LT3000 sensor may be installed per tank. 2.1 Wiring ****Note: All wiring should conform to NEC Code or applicable local standards**** Electrical wiring (for 115, 230VAC power or 24VDC power). The correct voltage is marked on the baseboard LT3000BB card. Pass the power (2 wires + GND) and signal cables (2 wires) through the conduit opening in the housing. Unplug the top part of the 5-way connector J2. Wire the leads in the following order: See drawing # J2 J2,Pin 1: AC power, L1 - black (+ for DC Powered Units) (Note - pin 1 is the closest one to the board edge) J2,Pin 2: AC power, L2 - white (- for DC Powered Units) J2,Pin 3: protective ground yellow/green (enclosure ground) * J2,Pin 4: current output (+) J2,Pin 5: current output negative (-) * It is very important that the green earth grounding wire is connected to pin 3 for all units, both AC and DC powered. This assures shielding of the electronics from electrical noise by grounding the aluminum enclosure. Then, plug the connector into the board. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - THE FOLLOWING WIRING IS NORMALLY DONE AT THE FACTORY, THESE INSTRUCTIONS WOULD ONLY BE NECESSARY IN THE EVENT THAT A TRANSDUCER HAS TO BE REPLACED IN THE FIELD. To replace transducer, take the LT3000BB out of the housing, screw the transducer into the bottom hole in the housing, and connect transducer cable to J1(See Drawing J1): J1,Pin 1: J1,Pin 2: J1,Pin 3: J1,Pin 4: COMMON SHIELD (note - pin 1 is the closest one to the board edge) RED (transducer lead) leave unconnected WHITE (temperature sensor) Install first LT3000BB inside the housing, then plug LT3000SC in and screw the lid on (with a gasket). - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3

2.2 Selecting Loop Power Source ; Internal or External The 4-20mA output from the LT3000 can be either internally powered (LT3000 provides power on loop) or externally powered (Customer provides power source for loop). To select internal loop power place jumper J5 on the center pin and the pin labeled INT (see Drawing J5). To select external loop power place jumper J5 on the center pin and the pin labeled EXT (See Drawing J5). The wiring of the loop may now be completed to a load or readout device. Typical wiring diagrams are shown in Diagram # 101 in this manual. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3. SETTING UP 4mA AND 20mA CALIBRATION RANGE 3.1. Calibrating the "tank full and the "tank empty" levels. Setting the close (top) and the far (bottom) range is performed by a simple push-button sequence, while the sensor is pointed and locked-in on a target placed at the appropriate distance. It can also be done with the sensor mounted on the tank, as long as the level of the material is appropriate for the required (top or bottom) setting. It is entirely up to the user to decide whether 20mA output should represent the top or the bottom level (the same with 4mA). Note that one should normally avoid setting the 20mA and 4mA at the same level. Note: The close or top range must be at least 10 from the face of the transducer. This dead zone expands slightly at higher temperatures. Before starting the setup, make sure that the actual level (or target) does correspond to the required top or bottom range, and is not moving. Take off the lid and observe the LED indicator: GREEN = OK RED = errors (for example - Loss Of Echo, occurs with a 30 second delay) YELLOW = first 4 sec after power-up YELLOW FLASH = acknowledge (during user setup) Please notice that the LED will flash Yellow once per minute in normal operation It is also advantageous (although not necessary) to have a milliampmeter connected in-series with the current loop - this will allow monitoring the stability of the target and also would help in case of trouble shooting by allowing you to read error codes (see appendix). To assign 20.0mA to the actual target distance (level): 4

a) Make sure that LED is Green, wait 30 seconds b) Press the push button and hold for 3s (2-5s). LED will turn Yellow - at this time, release the push-button and observe the LED producing a Yellow flash (acknowledge). The actual level is now stored. To assign 4.00mA to the actual target distance (level): a) Make sure that LED is Green, wait 30s b) Press the push button and hold for 10s (7s-15s). LED will first turn Yellow, keep holding the button, when the LED turns Red - release the button and observe the LED producing a Yellow flash (acknowledge). The actual level is now stored. The levels are stored in permanent memory that persists throughout power losses, until the setup procedure is repeated again. The system ignores accidental pressing of the push button for times less than 1 sec. Note that holding the button continuously for more than 1 minute when LED goes Red again (LED goes Yellow, Red, off and then Red again) will cancel the calibration sequence. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3.2. Temperature sensor calibration (use only in case of transducer replacement, or of LT3000SC board replacement). The temperature calibration is performed at 65-70F, may be done in-doors, regardless of the target placement. The current loop need not be connected. When bringing the unit indoors, make sure to wait about 30minutes for the temperature inside the transducer to equalize with the ambient temperature. Power the unit up, point it towards any target, wait for the LED to turn green, then press and hold the push-button for 17-30s, watch LED turn yellow, then red, then it turns off. Release the button when the LED is turned off (yellow flash=acknowledge). 5

APPENDIX A CURRENT LOOP OUTPUT AND ERROR CODES. 4.00-20.00mA - NO ERROR, linear function of level or distance, resolution 0.02mA (+/-0.01mA) ERROR CODES (not valid in the first 4s on power up): 0.00mA - LOSS OF POWER OR CIRCUIT FAILURE 0.02mA - BLANKING ERROR (target too close) 0.04mA - LOSS OF ECHO 0.08mA - TIMER/COUNTER FAILURE 0.16mA - ENVELOPE ERROR 0.32mA - TEMPERATURE ERROR 0.64mA - EEPROM CRC ERROR 1.28mA - EEPROM R/W ERROR 2.56mA - PUSH-BUTTON IS STUCK >21mA - OUTPUT SHORT OR CIRCUIT FAILURE Note: (1) the actual software revision number is displayed through the current output (in ma), in the first 4 seconds after power up, for example 1.02mA indicates the revision 1.02 (2) The error codes are additive, that is when more than one error occurs, their codes will add-up, for example, TEMPERATURE ERROR + LOSS OF ECHO will result in 0.36mA current. 6

APPENDIX B TROUBLE-SHOOTING 0.00mA - LOSS OF POWER OR CIRCUIT FAILURE - If LED is off - check the power supply wiring. Make sure that the voltage rating is correct. Check the fuse F1, replace if blown. Otherwise replace the unit or LT3000BB (Note - new LT3000BB requires tuning of inductors L1 and L2) - If LED is green, check the current-loop wiring, make sure that the current loop voltage is within 14-30V and of the correct polarity (J2 pin 4 = "+"). Replace LT3000SC (plugin) board. 0.02mA - BLANKING ERROR - Make sure that the transducer is not covered by a build-up, not immersed or is not in contact with a hard object (face-on). If the above is not the case, then replace the transducer. 0.04mA - LOSS OF ECHO (LOE) - This can happen intermittently under certain severe conditions, for example - if liquid material in the tank is severely agitated, covered with thick foam or if there is excessive amount of certain gases (i.e. CO2 or CH4). Normally, the device will hold the last valid level measurement for 30s before the LOE error is displayed, thus if an abnormal condition lasts less than 30s, LOE error will not show up though the response time may be compromised. If the LOE error persists even under optimal condition (i.e. indoors pointing at a wall 15' away), then check if transducer is not covered with a build-up (clean it!) or broken. Note that the transducer may physically break when exposed to temperatures higher than 80C, or in certain chemically active solvents or vapors. 0.08mA - TIMER/COUNTER FAILURE - Circuit failure, replace LT3000SC (plug-in) board 0.16mA - ENVELOPE ERROR - Under present software revision, this error is not tested against and should not happen. 0.32mA - TEMPERATURE ERROR - Check if the temperature inside the tank is not exceeding 100C or is below -60C. Note that the transducer may physically break when exposed to temperatures higher than 80C. Otherwise, if the process temperature is within a spec, check the transducer connection (J1 pin 4, white). Check the temperature sensor by connecting it to a 9V battery through a 1kohm series resistor (the shield = "-", the white lead = "+") Measure a voltage drop across the temp sensor - should be 1.6-2.2V Replace the transducer, if broken or LT3000SC (plug-in) board otherwise. 0.64mA - EEPROM CRC ERROR - This may happen temporarily under a condition of extreme external electrical noise. Make sure that the power line is not shared with high power mechanically commutated electric motors, electric welders etc. Otherwise, if the error is persistent, replace LT3000SC (plug-in) board. 1.28mA - EEPROM R/W ERROR - Circuit failure, replace LT3000SC (plug-in) board. 7

2.56mA - PUSH-BUTTON IS STUCK - Push button is mechanically stuck (in), or electrically shorted (for example, by excessive moisture). Pull it up and clean it, otherwise replace LT3000SC (plug-in) board. >21mA - OUTPUT SHORT OR CIRCUIT FAILURE - Circuit failure or current loop connection is shorted. Unplug the J2 plug and see if the error persists, if so then fix the current loop wiring, otherwise replace LT3000SC (plug-in) board. <3.5mA and LED stays yellow all the time - Circuit failure, replace LT3000SC (plug-in) board. 8

9

10

11

Warranty All components of the LT3000 are warranted to be free from defects in material and workmanship for a period of one year from the date of purchase. This warranty applies to general purchaser and to components installed, serviced and operated according to instructions. Babbitt International, Inc. will repair or replace, at its option, FOB at its plant or any other location designated, any part which proves to be defective in manufacture or workmanship. All claims must be made in writing within the warranty period. No claims outside the warranty period will be honored. Warranties are not applied to any components which have been damaged by improper installation, use, exposure to unusual atmospheric conditions or components which have been misused, abused, damaged by neglect or accident. This warranty shall not apply to any components, which have been altered or repaired without the prior written consent of Babbitt International, Inc. Babbitt International, Inc. assumes no responsibility or liability for any labor or material backcharges, without written authorization. THE FOREGOING IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTIES OF MERCHANTIBILITY AND/OR FITNESS FOR PARTICULAR PURPOSE, AND BABBITT INTERNATIONAL, INC. ASSUMES NO OTHER LIABILITIES EXPRESS OR IMPLIED. BABBITT INTERNATIONAL, INC. SHALL NOT BE LIABLE FOR NORMAL WEAR AND TEAR, NOR FOR DIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES. IN NO EVENT SHALL BABBITT INTERNATIONAL INCORPORATED S LIABILITY EXCEED THE PRICE OF ITS PRODUCT AT THE TIME OF PURCHASE. 12