Ultrasonic level measuring device, non-contact

Similar documents
OEM radar transmitter, for aggressive media level measurement

Ultrasonic level transmitter, non-contact

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Digital flow ELEMENT transmitter for continuous flow measurement

Conductivity Transmitter

ph or ORP Transmitter

Digital inductive conductivity transmitter

Digital flow transmitter for continuous flow measurement

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Digital batch controller

INSERTION paddle wheel flowmeter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

prosonic T FMU230, FMU231

Pressure measurement. Process pressure/hydrostatic VEGAWELL 52. Product Information

SALES SERVICE +358 (0)

Explosion proof rotary actuator - On/Off or programmable regulating actuator

Technical Data. General specifications. Rated operating distance s n 3 mm

Resistance thermometer Model TR30, compact design

Miniature resistance thermometer Model TR33, thread-mounted

Universal process controller econtrol

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

Electromagnetic Flow Transmitter

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Pressure measurement. Process pressure/hydrostatic VEGAWELL 72. Product Information

Resistance thermometer Model TR30, compact design

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Universal process controller econtrol

Pressure measurement. Process pressure/hydrostatic VEGAWELL 52. Product Information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Positioner with HART Communication Type 3780

2/2-Way Solenoid Control Valve

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Rosemount 3101, 3102, and 3105

Technical Information Nivector FTC968, FTC968Z

2-wire level transmitter

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span

FLOWave SAW-Flowmeter

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

MINI MCR-SL-UI-I-LP-NC

The Radar Level Meters can be installed both in metallic or non metallic tanks; their use is not harmful to humans or environment.

2/2 way Proportional Valve (motordriven)

Valve Island with Electronic I/O

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Pressure Transmitter SIL

Field indicator for current loops with HART communication Models DIH50, DIH52

ED701 General Industry Pressure Transmitter

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Relative and absolute pressure transmitter type 528

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

Level measurement Radar

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160

Cable Glands, Metal, for shielded EMC Cables CG.EM.*.*.*

Universal process controller econtrol

Resistance thermometer Model TR30, compact design

Submersible pressure sensor For water and wastewater Model LW-1

Design and applications

Georg Fischer Piping Systems Point, Ultrasonic & Radar Level Products

Ult r a s o n i c le v e l me t e r s ULM 55

Resistance thermometer Model TR31, miniature design

Digital conductivity transmitter

Mechatronic pressure measurement. Applications. Special features. Description

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

Ultrasonic Level Transducer Type: MPUL06 Article No.: ca. 122

Level and Pressure. Product Information. Vibrating level switches

The transducer component converts the measured signal and displays the actual value.

LST100 Ultrasonic level transmitter for upstream oil and gas

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Temposonics. Magnetostrictive Linear Position Sensors. TH SSI Data Sheet

Technical Information Condumax CLS21D/CLS21

Technical Information Barrier RB223

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Level Measurement. GDSL Series. Ultrasonic Level Sensor

process measurement solutions Mobrey MSP IP wire 24V loop powered ultrasonic level transmitters

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Electronic temperature switch with display Model TSD-30

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Temposonics. Magnetostrictive Linear Position Sensors. ET Analog Data Sheet

Ultrasonic Liquid Level Transmitters

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

RMA42. Technical Information

TIDALFLUX 2300 F Technical Datasheet

Level Measurement Continuous level measurement Radar transmitters

OPTIWAVE 1010 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

Transcription:

Ultrasonic level measuring device, non-contact For level measurement up to 8 m 4... 20 ma/hart - 2 wires Suitable for solids ATEX approvals Type 8177 can be combined with... Type 8611 Type 8793 Type 8802-GB Type 8644 PLC Universal process controller econtrol on a valve Process controller Classic control valve system Valve islands The Type 8177 is a non-contact ultrasonic level measuring device designed for continuous level measurement in open or closed vessels. The unit is suitable for liquids, but also for solids, in virtually all industries, particularly in water and waste water management. Accuracy diagram General data Materials Housing Cover Seal ring Ground terminal PBT, Stainless steel 316L (1.4435) PC NBR Stainless steel 316Ti/316L (1.4571/1.4435) Wetted parts Process connection, transducer Process seal PVDF EPDM Display LCD in full dot matrix Process connection Thread G2 or NPT2 Max. torque mounting boss 25 Nm Electrical connection Cable glands M20 x 1.5 Measuring value Distance between lower edge of the transducer and product surface Dead zone 0.4 m Measuring range 0.4 to 8 m (for liquids) 0.4 to 3.5 m (for solids) Process temperature -40 to +80 C (-40 to 176 F) Vessel pressure -0.2 to 2 bar (-2.9 to 29.02 PSI) (-20 to 200 kpa) Vibration resistance Mechanical vibrations with 4 g and 5... 100 Hz Temperature coefficient 0.06%/10K (Average temperature coefficient of the zero signal - temperature error) Resolution max. 1 mm Frequency 55 khz Interval > 2 s (dependent on the parameter adjustment) Beam angle at 3 db 11 Adjustment time 1) > 3 s (dependent on the parameter adjustment) Accuracy < 0.2% or ± 4 mm (see diagram) 1) Time to output the correct level (with max. 10% deviation) after a sudden level change. www.burkert.com p. 1/5

Electrical data Operating voltage Permissible residual ripple Output signal Resolution Fault signal Current limitation Load Damping (63% of the input variable) Environment Ambient temperature with display, adjustment elements Relative humidity Standards and approvals Protection Overvoltage category Protection class Standard EMC Security NAMUR Approvals 14-36 V DC or 14-30 V DC (Ex ia instrument) < 100 Hz: Uss < 1 V 100 Hz... 10 khz: Uss < 10 mv 4... 20 ma/hart 1.6 A current output unchanged; 20.5 ma; 22 ma < 3.6 ma (adjustable) 22 ma see load diagram 0... 999 s, adjustable -20 to +70 C (-4 to 158 F) (operation and storage) Max. 75% (operation), max. 85% (storage); without condensation IP66/IP67 with M20 x 1.5 gland mounted and tightened III II EN61326 EN61010-1 NE 21; NE 43 ATEX 2) : EN50014; EN50020; EN50284 Specifications Ex - Protection Categories 1/2G or 2G - Certification Ex ia IIC T6 Conformity specifications 2) Operating voltage Ui Short circuit rating li Power limitation Pi Ambient temperature Internal capacity Ci Internal inductivity Li 2) homologation certificate PTB 07 ATEX 2003X 30 V 131 ma 983 mw -20 to +41 C (-4 to 105.8 F) (dependent on categories) negligible negligible Load diagram 1 HART load 2 Voltage limit Ex ia instrument 3 Voltage limit non-ex instrument 4 Operating voltage p. 2/5

Target applications Continuous level measuring for fluids and solids Distance measuring Open basins Sludge container A typical application for the 8177 ultrasonic measuring device is level measurement in open basins. Products such as rain water or sewage water, i.e. with impurities. Here is where the advantages of non-contact measurement with the 8177 come into their own: simple and maintenance-free. The degree of pollution of water or an accumulation of mud in the basin is not important, because the 8177 measures the surface. In sewage treatment plants, the accumulated sludge is dewatered and transported via conveyor belts to containers. The 8177 measuring device measures the filling of the container. An empty container can thus be readied in good time before the max. level is reached. Principle of operation The transducer of the ultrasonic measuring device emits short ultrasonic pulses, at 55 khz to the measured product. These pulses are reflected by the medium surface and received by the transducer as echoes. The running time of the ultrasonic pulses from emission to reception is proportional to the distance and hence to the level. An integrated temperature sensor detects the temperature in the vessel and compensates the influence of temperature on the signal running time. The determined level is converted into an output signal and transmitted as a measured value. The measuring device is adjusted with the display/configuration. The entered parameters are generally saved in the measuring device Type 8177. Optionally, parameters may also be uploaded and downloaded with the display/configuration. p. 3/5

Set up with display/configuration The display/configuration can be inserted into the measuring device and removed again at any time. It is not necessary to interrupt the power supply. The measuring device is adjusted via the four keys of the display/configuration Display/configuration LCD Display Interrupt input Jump to the next higher menu Indicating of the menu item number Move to the menu overview Confirm selected menu Edit parameter Save value Change value of parameter Menu change Selecting from a list Select editing position Dimensions [mm] approx. 75.5 ø 80.5 ø 91 190 123 ø 74 SW60 G 2 NPT 2 84 22 M20 x 1.5 cable gland ø 50 M20 x 1.5 closing screw p. 4/5

Ordering chart for compact measuring device Type 8177 Item no. Specifications Operating voltage Output Electrical connection with display/ configuration without display/ configuration G2 mounting thread 14-36 V DC 4... 20 ma/hart NPT2 mounting thread 14-36 V DC 4... 20 ma/hart Ex version - ATEX approval 14-30 V DC 4... 20 ma/hart G2 mounting thread Cable gland M20 x 1.5 558 224 559 243 Cable gland M20 x 1.5 558 225 559 244 Cable gland M20 x 1.5 558 226 559 245 Ordering chart - accessories for measuring device Type 8177 (has to be ordered separately) Specifications Item no. Set with 2 reductions M20 x 1.5/NPT½ + 2 neoprene flat seals for cable gland + 2 screw-plugs M20 x 1.5 551 782 Set with a display/configuration, a transparent cover and a seal ring 559 279 Set with a transparent cover and a seal ring 561 006 Interconnection possibilities with other Bürkert devices Type 8802-GB - Classic Control valve system Type 8177 - Ultrasonic level measuring device PLC Type 2100 - Angle seat valve Type 8110 - Level switch *To find your nearest Bürkert office, click on the orange box www.burkert.com In case of special application conditions, please consult for advice. Subject to alteration. Christian Bürkert GmbH & Co. KG 1301/6_EU-en_00895005 p. 5/5