RAMSES. A modular multispectral radiometer for light measurements in the UV and VIS

Similar documents
Improving the Collection Efficiency of Raman Scattering

Experimental Analysis of Luminescence in Printed Materials

metcon meteorologieconsultgmbh, Instruments for Atmospheric Research W1aa_Feb_2017_1.doc 1 -

Aqualog. CDOM Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

Report on BLP Spectroscopy Experiments Conducted on October 6, 2017: M. Nansteel

LI-192 Underwater Quantum Sensor

Optical In-line Control of Web Coating Processes

LI-193 Spherical Quantum Sensor

The only simultaneous absorbance and f uorescence system for water quality analysis! Aqualog

Dual-FL. World's Fastest Fluorometer. Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE

Aqualog. Water Quality Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE

JETI Specbos Instruments

A stray light corrected array spectroradiometer for complex high dynamic range measurements in the UV spectral range.

Aqualog. Water Quality Measurements Made Easy FLUORESCENCE

Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region

Program for UV Intercomparison 2014 in Davos:

The Standard for over 40 Years

GEO-SolarSIM-D2 and SunTracker-2000/3000

We bring quality to light. MAS 40 Mini-Array Spectrometer

SPECTRAL IRRADIANCE DATA

Coating Thickness Measurement System

Influence of the light spectral distribution used in the radiometers calibration

HR2000+ Spectrometer. User-Configured for Flexibility. now with. Spectrometers

Spark Spectral Sensor Offers Advantages

BTS2048-UV. Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED.

INSTRUCTION MANUAL UV RADIOMETERS

BTS2048-BS. Product tags: VIS, Spectral Data, Industrial Applications, Laser.

QE65000 Spectrometer. Scientific-Grade Spectroscopy in a Small Footprint. now with. Spectrometers

Broadbandradiometer specbos 1211

The Faroese Fisheries Laboratory. Light in Faroese Waters

Light, Color, Spectra 05/30/2006. Lecture 17 1

Table 8 Overview light sources

HD HD HD AND HD PHOTO-RADIOMETERS LG-2

LED Tester BTS256-LED

INDIUM SENSOR. Type X.5 Series

CU-LASP Test Facilities! and Instrument Calibration Capabilities"

Lecture 2. Electromagnetic radiation principles. Units, image resolutions.

Spectroradiometer specbos 1201

OPAL Optical Profiling of the Atmospheric Limb

LED Lighting Flux and Color Measurement System (LFC)

QUANTITATIVE GLOBAL MAPPING OF TERRESTRIAL VEGETATION PHOTOSYNTHESIS: THE FLUORESCENCE EXPLORER (FLEX) MISSION

Lab Junior Educational UV-VIS Spectrometer

SPECTRAL SCANNER. Recycling

CMOS Based Compact Spectrometer

AvaLight-DHc Full-range Compact Light Source

UV AQUAtracka. In-situ PMT Fluorimeter

Improved Radiometry for LED Arrays

TRACEABLE SOLAR RADIATION MEASUREMENTS

Oriel Flood Exposure Sources

UV Measurement. Information Sheet. Dipl.-Ing. Andreas Renzel. Basics of UV measurement and solutions for UV curing applications.

Introduction to the operating principles of the HyperFine spectrometer

Abstract No. 32. Arne Bengtson and Tania Irebo. Swerea KIMAB AB, Isafjordsgatan 28A, SE Kista, Sweden

Development of a spectrometry system Using lock-in amplification technique

Measurement and Measurement Error of Light Used for Photosynthesis & Plant Growth Richard Garcia April 20, 2010

UNIVERSITY OF CALIFORNIA, SAN DIEGO SCRIPPS INSTITUTION OF OCEANOGRAPHY VISIBILITY LABORATORY. On the Measurement of Radiant Energy for

FiberLight Miniature UV-Vis Light Source for Mobile Spectroscopy and Online Process Control

Microscope-Spectrometer

Spectroscopy in the UV and Visible: Instrumentation. Spectroscopy in the UV and Visible: Instrumentation

UV / VIS Spectrophotometer EMCLAB Instruments GmbH

On the use of water color missions for lakes in 2021

PGS Family Plane Grating Spectrometer from ZEISS

AIXUV's Tools for EUV-Reflectometry Rainer Lebert, Christian Wies AIXUV GmbH, Steinbachstrasse 15, D Aachen, Germany

Company synopsis. MSU series

Model S471-LED Optometer

Integrating Spheres. Why an Integrating Sphere? High Reflectance. How Do Integrating Spheres Work? High Damage Threshold

MERIS US Workshop. Instrument Overview. Steven Delwart

LINEARPYROMETER LP4. Technical Documentation KE November TN

Non-Descanned FLIM Detection in Multiphoton Microscopes

Maya2000 Pro Spectrometer

Ground Truth for Calibrating Optical Imagery to Reflectance

instruments Analytical Instruments for Science

Components of Optical Instruments

USB. Part No Wavelength range. Spectral bandwidth 5 nm 4 nm Optical system

Miniaturized Spectroradiometer

Radiometry, apparent optical properties, measurements & uncertainties

Miniature Spectrometer Technical specifications

CONFIGURING. Your Spectroscopy System For PEAK PERFORMANCE. A guide to selecting the best Spectrometers, Sources, and Detectors for your application

Technological Advances in General Lighting. New Lightmeter for Solid State Lighting. State-of-the-Art LED Illuminance Meter

C4000. inline control. Photometric Converter. Real-time photometric converter. Factory zero for scattered light sensors

746A27 Remote Sensing and GIS

Spectroradiometer characterisations for traceable solar radiation measurements

ENMAP RADIOMETRIC INFLIGHT CALIBRATION, POST-LAUNCH PRODUCT VALIDATION, AND INSTRUMENT CHARACTERIZATION ACTIVITIES

LASP / University of Colorado

Calibration of ARM Spectral Shortwave Radiometers

University of Wisconsin Chemistry 524 Spectroscopic Components *

Instrumental and Methodological Developments in UV Research

Fully Portable Spectrophotometer for Transmission Measurement

DETECTORS Important characteristics: 1) Wavelength response 2) Quantum response how light is detected 3) Sensitivity 4) Frequency of response

Spectral signatures of surface materials in pig buildings

BTS256-EF. Product tags: VIS, Spectral Measurement, Waterproof, WiFi. Gigahertz-Optik GmbH 1/7

Microscopic Structures

MS260i 1/4 M IMAGING SPECTROGRAPHS

Chemistry 524--"Hour Exam"--Keiderling Mar. 19, pm SES

Basic Components of Spectroscopic. Instrumentation

The Standard for over 40 Years

Thermo Scientific icap 7000 Plus Series ICP-OES: Innovative ICP-OES optical design

Lecture Notes Prepared by Prof. J. Francis Spring Remote Sensing Instruments

UV-VIS-IR Spectral Responsivity Measurement System for Solar Cells

Preliminary Characterization Results: Fiber-Coupled, Multi-channel, Hyperspectral Spectrographs

Capabilities of NIST SIRCUS for Calibrations of SSI Vis-IR Instruments

Transcription:

RAMSES A modular multispectral radiometer for light measurements in the UV and VIS Rüdiger Heuermann a, Rainer Reuter b and Rainer Willkomm a a TriOS Mess- und Datentechnik GmbH, Oldenburg, Germany b Fachbereich Physik, Carl v. Ossietzky Universität Oldenburg, Germany ABSTRACT Solar radiation is the energy source for all photosynthetic life-forms. Due to their individual pigment compositions only a specific part of the spectrum can be used by the single species for photosynthesis. Therefore multispectral radiation measurements are helpful for their investigation and monitoring. With the background of increasing ultraviolet radiation due to the decreasing ozone layer in the atmosphere, the measurement of the UV-A and UV-B part of the spectrum is of increasing interest to people. In the RAMSES project (Radiation Measurement Sensor with Enhanced Spectral Resolution), founded by the German Ministry of Research and Technology, a new subminiature multispectral radiometer is under development. This new instrument allows spectral measurements in the range from 25 to 72 nm. A modular concept of the instrument, combined with very low power consumption, allows to use the instrument in profiling systems as well as in stand-alone applications, such as moorings, monitoring systems or weather stations. Sensor heads with different detection characteristics are available, and up to 16 of them can be combined to a single instrument for simultaneous measurement, e.g for up-welling and downwelling light. Typical applications of this instrument are satellite calibration and validation, UV measurements, biology, ecosystem modelling, water quality and even climatology. Keywords: multispectral, spectrometer, underwater light field, ultraviolett, visible, radiation, radiometer, light sensor 1 INTRODUCTION Measurement of solar radiation in the water column is a well-known method in marine science. The in situ light field is influenced by absorption and scattering of different substances and life-forms like phytoplankton, yellow substance, contaminants and by the water itself (Jerlov, Morel and many other). In biology works PAR (Photosynthetically Available Radiation), as the integral value of the irradiance from 4 to 7 nm, is most commonly used to characterise the conditions for photosynthesis of phytoplankton communities. Due to the individual pigment composition of different species the usefulness of a given light field for photosynthesis is not a simple function of the total intensity of PAR. It depends also on the spectral distribution of quanta, especially with regard to the absorption spectrum (Fig.1) of the phytoplankton. To account for this Morel (1978) introduced the concept of PUR (Photosynthetically Usable Radiation), which is a modified PAR obtained by weighting it across the spectrum with the specific absorption spectra of phytoplankton. Fig. 2 a-b shows the spectral distribution and the vertical decrease at two selected wavelengths of the down-welling irradiance in the presence of a deep chlorophyll maximum at different water depths at a station in the western Arabian sea. Fig. 2 c represents the chlorophyll fluorescence which has been measured simultaneously to the irradiance. The bold lines in Fig s. 2 a and b represent the curve calculated for the absence of chlorophyll. The figures clearly shows the spectral selective light absorption by the phytoplankton and therefore the necessity of multispectral radiation measurements. Studies of the behavier of different life-forms on ultraviolet radiation shows non-repairable damages. In view of increasing ultraviolet radiation due to decreasing ozone in the atmosphere, it becomes more and more interesting to extend the spectral light measurements from the visible to the UV-A and UV-B parts of the spectrum. To meet these requirements, a new multispectral radiometer series with a modular concept is under development. The performance of these instruments includes: high resolution multispectral detection in the UV and VIS from 25-72 nm up to 16 multispectral sensors in a single system specialized UV detection modules

sensors with different detection characteristics for the measurement of different parameters low power consumption to make the instrument suitable for handheld and moored applications modular setup for customized sensor configurations operation down to 3m for use in multiparameter probing systems.15 E_down / W/m^2/nm.1.5 4 45 5 55 6 wavelength / nm Fig.1: (a) Specific absorption spectra of the main phytoplankton classes (after Mobley,1994); (b) Down-welling irradiance at water depths between 4 and 7 m with 2 m intervals at a station in the western Arabian sea taken in May 1997 on board RV Sonne. depth / m 4 45 5 55 6 Ed(1 3m),av. 65 with chl. 469nm 7.5.1.15.2 Ed / W/m^2/nm depth / m 4 45 5 55 6 65 Ed(1 3m),av. with chl. 555nm 7.5.1.15 Ed / W/m^2/nm depth / m 4 45 5 55 6 65 7 2 4 6 8 1 chlorophyll fluorescence / ru 4 Fig.2: Down-welling irradiance at 469 nm (a) and 555 nm (b) from 4 to 7 m taken from the same profile as shown in Fig 1b. The full lines are the calculated values for a situation without a deep chlorophyll maximum between 4 and 5 m (according to values from 1-3 m). (c) distribution of in situ chlorophyll fluorescence measured simultaneously with the radiation.

2 TECHNICAL REALIZATION 2.1 Modular concept The main concept of the RAMSES radiometer family is to divide the functionality of the whole instrument into a set of individual modules, which can be easily combined to customized instruments. This offers the highest flexibility for a wide field of applications. The functions of these modules are, e.g. spectra aquisition, data storage, data interfacing, time scheduler, analog output, etc. Each module is taxable via specific control commands. These modules are connected through a two-wire serial bus. Fig. 3 illustrates this serial network of single modules. Fig.3: Schematic diagram of the serial network of the RAMSES radiometer Fig. 4: Two multispectral light sensors for plane irradiance measurement connected to a data storage and acquisition unit (with internal battery pack). The multispectral light sensor modules are mounted in small pressure resistant housings for operation depths of down to 3m. This maximum operation depth is of course not valid for radiation measurement, but makes the instruments suitable for the use in multiparameter systems without unmounting them for deep sea operations. The possibility of individual positioning of each detector allows them to be used in open ocean water, where the shading by other instruments must be avoided, as well as in highly turbid waters, where measurement of up-welling and down-welling light must be done with sensors positioned at identical depth. An additional module with a two-axis inclinometer and a pressure sensor can be added to each light sensor module. Up to 16 multispectral light sensors can be assembled in to one instrument using a central data storage and acquisition unit (Fig. 4).

2.2 Multispectral light sensors A monolithic miniature spectrometer, manufactured by Carl Zeiss, Germany, is integrated in each multispectral light sensor. This spectrometer consists of a quartz fibre bundle with a circular arrangement of the single fibres at the entrance and a linear one at the other end. The linear end forms the entrance slit of a spectrograph. A silicon photodiode array with 256 diodes is used as a detector. Fig. 5 shows a module mounted on an electronic circuit, developed within this project. This highly integrated circuit generates all signals required for operation of the diode array, signal processing, data conversion and the interface to the sensor network. The use of components with low power consumption and the integrated power management in each module reduces total energy requirements of a complete module to.85 W in full operation mode. Most energy is needed for the analog part of the electronics. Therefore the integrated microcontroller switches the analog part off after a measurement. This reduces the power consumption to 2 mw. Analog to Digital conversion is done by a 16 bit ADC (+/- 2 LSB). Together with a switchable integration time for the diode array in the range from 4 ms up to 8 s, the total dynamic range is 25 bit. The miniature spectrographs are available in an UV/VIS version (19-735nm; 2.2nm/pixel) and a specialized UV Version (2-4nm;.8 nm/pixel). The stray-light discrimination in the UV modules is an order of magnitude better than the UV/VIS versions. In combination with the higher spectral resolution they are suitable for high accuracy UV measurements. Table 1 shows the summarized characteristics of both modules. Technical specifications UV/VIS UV optical wavelength range 25-72 nm 25-4 nm detector type 256 channel silicon photodiode array spectral sampling 2.2 nm / pixel.8 nm / pixel spectral accuracy.2 nm.2 nm stray light < 1x1-3 < 5x1-4 usable channels 23 19 electrical A/D resolution 16 bit A/D converter, 14 bit specified integration time 4 ms - 8 sec. dynamic resolution 25 bit telemetry interface RS-232 or Serial Bus data rate (RS-232) 1,2-19,2 baud (user selectable) power requirements 1.5-11 VDC.85 W (data acquisition active) 2 mw (interface active).5 mw (standby modus) connector SUBCONN-Micro 5 pins, male (others on request) optional sensors pressure, 2-axis inclinometer, internal temperature physical size 4.7 cm x 18. cm (without detector) 4.7 cm x 23. cm (with optional sensors) weight in air.5 kg (coated aluminium) 1.3 kg (stainless steel) depth rating 3 m (coated aluminium) 3 m (stainless steel) operation -1 to +4 C temperature Table 1: Technical specifications of the multispectral light sensors. Optical specifications following the data sheets of Carl Zeiss, Germany. For measuring different radiometric parameters, like scalar irradiance, vector irradiance or radiance, different collectors are needed in front of the fibre bundle of the spectrometers. In a first step three collector versions have been developed (Table 2).

MCC MSC MRC radiance L plane irradiance E scalar irradiance E E E d or E u up-welling or down-welling irradiance vector irradiance E and E (requires two modules) baffled Gerhun tube, field of view: 1 in water Table 2: The different collectors for the multispectral light sensors The spectral transmission of the collector material limits the usable UV spectral range of the modules to wavelengths greater than 25 nm. Therefore, not all of the 256 diodes of the detector array can be used for radiation measurement and the number of useful diodes depends on the type of spectrograph used. Fig 5: Miniature spectrometer with fibre optic bundle and highly integrated electronic. 2.3 Calibration Quantitative measurements require a careful correction of the spectral sensitivity of each module, including the collector. This is done by using calibrated deuterium lamps for the UV and tungsten lamps for the VIS part of the light spectrum, driven by stabilized power supplies. The emission of these lamps has been put in to quantitative terms before by calibrating them with primary standard lamps, following the NIST standard (Oriel). 2.4 Software Part of the RAMSES radiometer is an easy-to-use Windows based software. Main features of this software are: measurement control data recording online calibration of raw spectra different data display modes such as single spectra, time series, depth profiles online calculation of standard radiometric parameters different pre-defined functions for online display of integral values of specified spectral ranges, like PAR, UV-A, UV-B, or to fit interference filters used in satellites user defineable algorithms for data processing

3. PRELIMINARY RESULTS First measurements of a profiling system containing two multispectral light sensors and a data acquisition unit have been carried out on board the RV Heincke during a cruise in the German Bight in March 1999. A third multispectral light sensor was mounted on board the ship as a deck reference for continuous measurement of the incident light. Fig. 6 represents the incident irradiation at three selected wavelengths from the deck reference sensor. A depth profile of the in situ instrument is shown in Fig. 7 as a three-dimensional plot. 2 E d / W/(m 2 nm) 1 6 12 18 24 time/h Fig. 6: Incident irradiance at three selected wavelengths (32, 46 and 64 nm) over a period of 1 day. 2 E d / W/(m 2 nm) 1 1 depth/m 2 3 3 6 5 4 wavelength/nm 7 Fig.7: Depth profile of the down-welling irradiance taken on board RV Heincke during a cruise in the German Bight.

4. ACKNOWLEDGEMENT The development of the RAMSES modular multispectral radiometer is supported by a grant from the Federal Minister of Research and Technology, Bonn. 1. Jerlov, N.G., Marine Optics, Elsevier, Amsterdam, 1976 5. REFERENCES 2. Kirk, J.T.O., Light and photosynthesis in aquatic ecosystems, Cambridge University Press, second editon, 1994 3. Mobley, C.D., Light and Water: Radiative Transfer in Natural Waters, Academic Press, 1994 4. Morel, A., et al., Minimum Requirements for an Operational Ocean-Colour Sensor for the Open Ocean, IOCCG Report Number 1, 1997 5. Morel, A., Available, usable and stored radiation energy in relation to marine photosynthesis, Deep Sea Research, 25, 673-688, 1978