UNION COUNTY ENGINEER DIVISION OF BUILDING REGULATIONS

Similar documents
Journeyman's Practice Exam

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Article 225: Outside Branch Circuits And Feeders

Residential Construction Checklist Single and Two Family Construction

Part VIII Electrical GENERAL REQUIREMENTS CHAPTER 33

NEC 2014 Code Changes

Single-Family Dwelling Submittal Requirements

TO WHOM IT MAY CONCERN:

CONTINUING EDUC ATION

Electrical requirements for plans on all new homes, additions, remodels & Service upgrades

Wisconsin Contractors Institute Continuing Education

2014 NEC Changes Part 1

City of Lompoc Building & Safety Services Section 100 Civic Center Plaza Lompoc, CA Phone: Fax:

HAMMEL ASSOCIATES ARCHITECTS, LLC 2 5 E A S T G R A N T S T R E E T, S U I T E L A N C A S T E R, P E N N S Y L V A N I A

City of Thousand Oaks

CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT

1 Exam Prep NFPA 70: National Electric Code 2011 Tabs and Highlights

ECET Fall 2017 Name: _ Lab Assignment #01

Address: South Elgin, IL Phone: ( ) - Fax: ( ) - Cell: ( ) - Contractor Type: Phone: ( ) - Fax: ( ) - Cell: ( ) - Contact Type:

NOTICE OF RULE MAKING PROCEEDINGS AND PUBLIC HEARING

Permits (Submitted to Permit Counter) APPLICATION CHECKLIST

Application for Site Plan Review

SOLAR PV MICROINVERTER/ACM STANDARD PLAN - COMPREHENSIVE Microinverter and ACM Systems for One- and Two- Family Dwellings

Licensed Electricians Practical Assessment (LEP)

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

B. Manufacturers: Square-D, G.E. or Westinghosue.

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5

TRIBAL BUILDING AND DEVELOPMENT Plan Check Submittal

Regal Series Recessed Flatwalls

DESIGN REVIEW BOARD APPLICATION EXTERIOR PLAN / LANDSCAPE PLAN

Community & Economic Development Department Planning Division Frederick Street PO Box 8805 Moreno Valley, CA SUBMITAL REQUIREMENTS

PROVINCE.OF BRITISH COLUMBIA. ORDER OF THE LIEUTENANfelOVERNOR IN COUNCIL

PLAN SUBMITTAL REQUIREMENTS

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

APPLICATION FOR CERTIFICATE OF APPROPRIATENESS IN THE HISTORIC DESIGN REVIEW DISTRICT

Electrical Inspectors

RADIO AND TELEVISION SATELLITE EQUIPMENT

White Lake Township Building Dept Highland Rd. (248) White Lake, MI Fax (248)

Customer Connection Guide Updates Effective May 2017

Field Instruction. Induced voltages can occur in overhead lines, underground cables, or in switchyards.

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables

Page Electric Utility Service Specifications

BERKELEY COUNTY ENGINEERING AND

Article 250 Grounding & Bonding

Grounding and Bonding

2. All work and materials shall be in full accordance with Local and State ordinance and with any prevailing rules and regulations.

2017 NEC TABLE OF CONTENTS

SECTION MECHANICAL IDENTIFICATION

ER 87 Electrician Regulations Answer Schedule. Question 1 Marks Reference Marking notes. (1 mark) ESR 27(2) (2 marks) ESR 74A(1AA)

Basic Information Required for Photovoltaic Plan Check Submittal *Informational Purposes Only* 2013 CEC

Quality Control Checklist - Design Drawings

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION MECHANICAL IDENTIFICATION

Department of Labor and Industry Electrical Licensing

FIRE SPRINKLER SYSTEM SUBMITTAL CHECKLIST AND APPLICATION

BUILDING PLAN REVIEW REQUIREMENTS

SECTION BUILDING WIRE AND CABLE

PLANNING AND DEVELOPMENT

DOCUMENT SUBMITTAL REQUIREMENTS FOR A NEW SINGLE-FAMILY DWELLING

Alternating Current Power

American Electrical Institute

FTTH ENGINEERING AND INSTALLATION INTRODUCTION

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

STANDARD COMMENTS 2016 ELECTRICAL PLAN REVIEW CHECK LIST

Travis County ESD #1. Building Plan Submittals. Information Bulletin. Fire Marshal Hancock

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Applying the NEC to Amateur Radio. By Tim Kuhlman, PE

PLANNING Development Services Department

TOWN OF FLEMING 2433 Dublin Road, Auburn, NY Phone (315) , Fax (315)

SECTION EQUIPMENT WIRING

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

Yavapai County Development Services

PLANNING DEPARTMENT SUBMITTAL REQUIREMENTS FOR CONDITIONAL USE PERMITS CLASS 4 DEVELOPMENT REVIEW PROCESS. A. Written Material

ELECTRICAL GENERAL DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Electrical/Telecommunications Design

GCG ASSOCIATES, INC. February 8, Mr. Nathaniel Strosberg, Town Planner 101 Main Street Town of Ashland Ashland, MA 01721

Bulletin Voltage drop in single dwelling units Rule 8-102

Stray Voltage and Swimming Pools

2. Electrical rooms shall be centrally located and stacked so that feeder conduits and bus duct are run as straight and short as possible.

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

KC Water Rules and Regulations For Water Main Extensions and Relocations

GROUNDED ELECTRICAL POWER DISTRIBUTION. Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER

Residential Room Addition / Remodel Submittal Requirement Checklist

What Plans Do I Need for a Building Permit?

Bulletin Voltage drop in single dwelling units Rule 8-102

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

CITY OF LOVELAND HOMEOWNERS GUIDE FOR BUILDING PERMITS FOR HOME IMPROVEMENTS

Licensed Electricians Practical Assessment (LEP)

SUBMITTAL REQUIREMENTS FOR COMMERCIAL BUILDING PROJECTS

PLOT PLAN INSTRUCTIONS ROOF MOUNT SOLAR AN ACCURATE PLOT PLAN IS NECESSARY TO PROCESS YOUR PERMIT

Canadian Standards Association Mississauga, Ontario To the Part I Committee

Mailing Address: Fax number: City: State: Zip: Property Owner: City: State: Zip: City: State: Zip:

UFGS-16553N (Septermber 1999) UNIFIED FACILITIES GUIDE SPECIFICATIONS

NEW SINGLE FAMILY HOMES

SMALL PROJECTS & IMPROVEMENTS: DOG RUNS, PATIO ENCLOSURES & FENCES, EXTERIOR IMPROVEMENTS (Abbreviated Design Review Application)

CHECKLIST PRELIMINARY SUBDIVISION AND PRELIMINARY SITE PLAN

FINAL - IT 30 ELECTRICAL INSPECTOR EXAMINATION ANSWER SCHEDULE. Question 1 Marks Reference Marking notes. (2 marks) EA 2

UNITY/I TM. Installation Manual. UT3K, UT4K, UT5K and UT8K. Single-Phase Uninterruptible Power Systems

SECTION 5 TRANSFORMERS

Electric Service Guide. Residential Subdivision

Transcription:

UNION COUNTY ENGINEER DIVISION OF BUILDING REGULATIONS Residential Pool Permit Requirements FEES: A nonrefundable permit application fee of $25.25 and a nonrefundable plan review fee of $40.40 will be due at the time of application. (payable to Union County Building Department) Total due at time of application is $65.65. Pools will be charged a building permit fee of $50.50 building and $50.50 electrical permit fee. A mechanical fee of $40.40 will apply if your pool is heated as well as a gas piping fee of $40.40. Provide a zoning permit from the township/municipality Health Department site plan approval All plan submittals require two complete sets each stapled together Provide detailed plot plans showing distances to any structures, fence or barricade location and locations of any utilities in the area, underground or overhead, well and septic system location Provide manufacturer drawings of pool or structural drawings of concrete pool Provide fence, barricade, gate, door closure and or alarm description Show location of pool equipment and electrical requirements Show electrical disconnect locations, wiring information and electrical over current device information. Provide adequate information to show compliance with Article 680 of the 2014 National Electric Code Show location of related or unrelated electrical devices or equipment in vicinity of pool Complete the questions on the attached pages and make sure your drawings show all the required information TO SCHEDULE AN INSPECTION Call (937) 645-3019 You must have your building permit # and address to schedule inspections 233 West Sixth Street Marysville, Ohio 43040 937.645.3018 937.645.3161 Fax engineer@co.union.oh.us Page 1 of 3 1/3/2017

1. Yes No (Circle One) Are there any underground utilities within 5 feet of the pool (ie) electric, phone, TV cable, etc. if so the provisions of Article 680.10, 2014 NEC shall apply? Show location on your site plan. 2. Yes No (Circle One) Are there any overhead conductors in the vicinity of the pool, if so Article 680.8, 2014 NEC, overhead conductor clearance s table shall apply. Show location on your site plan. 3. Yes No (Circle One) Provide details showing the installation of the required equipotential bonding grid and any metal parts requiring bonding at metallic structural components, under water lighting, metal fittings, electrical equipment, metal wiring methods and associated metallic parts per Article 680.26, 2014 NEC. Include an overhead view of the required equipotential bonding grid as required per Article 680.26, 2014 N.E.C. (ie) type of material, location of the grid material embedment, etc. 4. Yes No (Circle One) Will there be any underwater pool lighting? If so provide a complete detail showing how many, what type, wiring methods used, branch circuit wiring, equipment grounding and any associated parts and fittings, per Article 680.23, 2014 NEC. 5. Yes No (Circle One) Will there be any lighting fixtures, lighting outlets, or ceiling suspended (paddle) fans installed above the pool or the area extending 5 feet horizontally from the inside walls of the pool? per Article 680.22, B, 2014 NEC. Show location on your site plan. 6. Yes No (Circle One) For dwelling unit(s) where a permanently installed pool is installed no fewer than one 125 volt 15 or 20 ampere receptacle shall be located not less than 6 feet from and not more than 20 feet from the inside wall of the pool per Article 680.22 A-3, 2014 NEC. And also have GFCI protection per Article 680.22 A-4, 2014 NEC. Show the location on your drawing and indicate GFCI. Page 2 of 3 1/3/2017

7. Show wiring methods on plans (i.e.) RMC, IMC, RNC, etc. This applies to all exterior wiring at dwelling units and must contain a copper equipment grounding conductor sized in accordance with Article 250.122 but not smaller than 12 AWG. Other wiring methods and materials shall be permitted in specific locations or applications as covered in Article 680.21 2014 NEC (ie) flexible connections, cord and plug connections, double insulated pool pumps. 8. Yes No (Circle One) One or more means to disconnect all ungrounded conductors shall be provided for all utilization equipment other than lighting. Each means shall be accessible and within sight from its equipment, per Article 680.12, 2014 NEC. 9. Will there be any specialized pool equipment (Circle all that apply) Underwater audio equipment Electrically operated pool covers which complies with ASTM F 1346 Deck area heater If so Article 680.27, 2014 NEC shall apply. Provide details for the installation, manufacturers installation instructions may suffice. 10. Will there be a diving board? If so, provide a diagram showing clearances meeting the ANSI/NSPI-5 requirements. 11. Yes No (Circle One) Will there be a pool water heater? If yes, please provide installation instructions along with a one-line diagram for the gas piping system and or electric as required per the manufacturer. Show required on/off switch and type of ignition system per Article 403.9.1, 2012 IECC. Pool covers are required for heated pools per Article 403.9.3, 2012 IECC. 12. Please provide details for entrapment protection for the suction outlets per AG 106. When applicable, show the required dual drain separation, atmospheric vacuum relief system and VGB grate covers. Page 3 of 3 1/3/2017