150W Compact Outdoor 1:1 Redundant System DESCRIPTION Teledyne Paradise Datacom s Outdoor series of redundant amplifier systems provide the highest degree of earth station redundancy and reliability. Based on Teledyne Paradise Datacom s family of rugged and robust SSPAs, these systems provide the highest MTBFs possible. These systems can be configured in either 1:1 or 1:2 redundant configurations using any of the Teledyne Paradise Datacom family of Outdoor SSPAs. The RCP2-1100/1200 Redundant Controller provides an extremely user-friendly interface for complete monitor and control of the high power amplifiers in either 1:1 or 1:2 configurations. The RCP front panel mimic display shows the on-line amplifiers and the current switch positions. Dedicated fault lights provide easy indication of system status. All RCP2-100 monitor and control is available locally, at the front panel LCD display, as well as remotely by the RS-232 or RS-485 interface ports. FEATURES System Output Power to: 1000W S-Band; 800W ; 800W -Band; 400W Universal Input, Power Factor Corrected Power Supply Output Power Monitoring Separate 1RU Redundant Controller or Controllerless configurations OPTIONS System Output Power Monitor Reflected Power Alarm L-Band Input Operation Cold Standby Amplifier Operation Custom Configurations Teledyne Paradise Datacom Teledyne Paradise Datacom Ltd. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End State College, P6803 www.paradisedata.com Witham, Essex CM8 3HA England Tel: (814) 238-3450 Tel: +44(0) 1376 515636 Fax: (814) 238-3829 Fax: +44(0) 1376 533764 1 O2
High Power Outdoor Output Power Ranges Band GaAs (W) GaN (W) S-Band N/A 600-1kW 400-600 650-800 -Band 350-500 650-800 200-250 300-500 See document # 214164 for GaAs High Power Outdoor SSPAs, and document # 211669 for GaN High Power Outdoor SSPAs Compact Outdoor Output Power Ranges Band GaAs (W) GaN (W) S-Band N/A 50-500 30-300 300-400 -Band 25-250 300-400 10-125 100-250 See document # 205485 for GaAs Compact Outdoor SSPAs, and document # 209555 for GaN Compact Outdoor SSPAs System Output Power Capacity Due to residual losses inherent in redundant system configurations (waveguide bends; switch and coupler losses), reduce the typical output power specification of a single amplifier by approximately 0.2 for 1:1 and by 0.4 for 1:2 systems. For example, a single thread 100W Compact Outdoor SSPA has a typical saturated output power of 50.0 (100W). Placing two of the above amplifiers in a 1:1 redundant system configuration would reduce the typical system saturated output by 0.2 to 49.8 (96W). Placing three of the above amplifiers in a 1:2 redundant system configuration would reduce the typical system saturated output by 0.4 to 49.6 (91W). Actual system losses will vary based on the system options. 2 O2
General Specifications PARAMETER NOTES LIMITS UNITS Gain Gain Flatness Gain Slope Gain Variation vs. Temperature Gain Stability Gain Adjustment minimum full band (all except Extended ) Extended units per 40 MHz (C-, -, s) per 10 MHz (S-Band) -40 to +55 C at constant temperature 0.1 resolution 70 ± 1.0 ± 1.5 ± 0.3 ± 0.2 ± 1.0 ± 0.25 20 /40 MHz /10 MHz /24 hours Intermodulation Distortion 3 back off relative to P 1-25 c AM/PM Conversion (@ rated P 1 ) (@P 1-3 ) Spurious Harmonics Input/Output VSWR Noise Figure Group Delay (per 40 MHz segment) Transmit Band Noise Output Power Density Receive Band Noise Output Power Density Residual AM Noise Phase Noise Environmental (@ rated P 1 ) (@ rated P 1-3 ) (C-,-,Ku-bands) (@ rated P 1-3 ) (S-band) (Extended with 1.3:1 VSWR option) at maximum gain (C-,-,Ku-bands) at maximum gain (S-band) Linear Parabolic Ripple T Band R Band (C- or Ku-bands) R Band (-Band) R Band (S-Band) S-Band, with optional filter S-Band, without optional filter 0-10 KHz 10 KHz - 500 KHz 500 KHz - 1 MHz Offset frequency from carrier 10 Hz 100 Hz 1 KHz 10 KHz 100 KHz 1 MHz 3.5 1.0-65 -50-30 1.50:1 1.30:1 10 8 0.01 0.003 1.0-75 -150-100 See options -155-95 -45-20 (1.25 + log F) -80-90 -100-110 -120-125 -130 / / c c c ns/mhz ns/mhz 2 ns p-p W/4 KHz W/4 KHz W/4 KHz W/4 KHz W/4 KHz c c c Operating Temperature Ambient -40 to +60 C Relative Humidity condensing 100 % Cooling System Integrated Forced air Mechanical Size, High Power Outdoor, single Size, Compact Outdoor, single Weight, High Power Outdoor, single Weight, Compact Outdoor, single width length height width length height Base unit (<200W S/C-bands; <100W Ku) Base unit ( 200W S/C-bands; 100W Ku) Base unit (<200W -Band) Base unit ( 200W -Band) With Internal zbuc 16.5 27.5 9.335 419 699 238 10.0 19.5 6.50 254 495 165 100 (45.5) 36 (16.4) ± 3% 44 (20.0) ± 3% 46.7 (21.1) ± 3% 54.9 (25.0) ± 3% +1.7 (0.8) c/hz c/hz c/hz c/hz c/hz c/hz inches mm inches mm lbs. (kg) lbs. (kg) lbs. (kg) lbs. (kg) lbs. (kg) lbs. (kg) Finish Paint White; powder coat 3 O2
L-Band Operation Teledyne Paradise Datacom amplifiers are available with an integrated L-Band Block Up Converter. L-Band units utilize Teledyne Paradise Datacom s proprietary zbuc technology. Adding a zbuc converter to an SSPA typically increases the gain by 2-4. In addition: the zbuc converter can detect and switch to an extenally supplied reference. an optional internal high stability (10MHz) reference is available. the zbuc converter can lock to an externally supplied reference of 10 or 50 MHz. the zbuc converter can accept a wide range of external reference power (-10 to +5 m) the zbuc converter can accept FSK monitor and control signal via the IFL. Electrical Specifications for Outdoor SSPA with ZBUC converter PARAMETER NOTES LIMITS UNITS Gain Gain Flatness Gain Slope Gain Adjusted Range Gain Stability Phase Noise Spurious Nominal setting full band (C-,-,Ku-bands) per 40 MHz (C-,-,Ku-bands) Typical Adj. Range Typical Adj. Range -40 to +60 C Offset frequency from carrier 10 Hz 100 Hz 1 KHz 10 KHz 100 KHz 1 MHz Available Frequency Plans Band Model Number IF Input LO Frequency RF Output C Sub-Band A 950-1525 MHz 4.900 GHz 5.850-6.425 GHz C Sub-Band B 950-1825 MHz 4.900 GHz 5.850-6.725 GHz C Sub-Band C 950-1870 MHz 4.800 GHz 5.750-6.670 GHz C Sub-Band E 950-1250 MHz 5.475 GHz 6.425-6.725 GHz C Sub-Band F 950-1250 MHz 5.775 GHz 6.725-7.025 GHz C Sub-Band G 950-1675 MHz 4.800 GHz 5.750-6.475 GHz C Sub-Band L 950-1550 MHz 3.450 GHz 4.400-5.000 GHz Sub-Band A 950-1450 MHz 6.950 GHz 7.900-8.400 GHz Ku Sub-Band A 950-1450 MHz 13.050 GHz 14.00-14.50 GHz Ku Sub-Band B 950-1700 MHz 12.800 GHz 13.75-14.50 GHz Ku Sub-Band D 1350-1650 MHz 13.750 GHz 15.10-15.40 GHz Ku Sub-Band F 950-1450 MHz 11.800 GHz 12.75-13.25 GHz Absolute max. -30-60 -70-80 -90-90 In-Band Signal Related (C-/) (Extended ) Close to Carrier Spurious ( 20 MHz) Local Oscillator C-band (typ.) -60-74 -84-100 -105-125 75 ± 2.0 ± 0.5 20 60-80 57-77 ± 1.5 -band (typ.) -58-70 -80-94 -97-122 -50-40 -50-30 Ku-band (typ.) -56-67 -78-91 -94-120 /40 MHz c/hz c/hz c/hz c/hz c/hz c/hz c c c m Noise Figure At Maximum gain 20 Transmit Band Noise Output Power Density Tx Band at Maximum gain -65 W/4kHz Input VSWR L-Band 1.5 : 1 Internal Reference Option Reference Accuracy (initial) Aging per day (after 30 days) ± 1 10-8 ± 1 10-9 Aging per year (after 30 days) ± 6 10-8 Reference Stability over Temperature (-40 to +40 C, ambient) ± 1 10-8 4 O2
Amp 1 RF IN-POL 1 Amp 2 RF OUT-POL 1 RF IN-POL 2 Amp 3 RF OUT-POL 2 1:1 Redundant HPA System 1:2 Redundant HPA System Teledyne Paradise Datacom s Outdoor Packaged Redundant Systems are designed with built -in redundancy for 1:1 systems. All system-level monitor and control is internal and no separate controller is required, although an optional RCP2-1100 1:1 Redundant System Controller is available. Either Ethernet or RS-485 communications are selectable for user monitor and control. All 1:2 redundant systems require a separate RCP2-1200 Redundant System Controller. RCP2-1100 1:1 Redundant System Controller RCP2-1200 1:2 Redundant System Controller The RCP2-1200 1:2 Redundant System Controller is the heart of the 1:2 redundant system. It provides an extremely user friendly interface for complete monitor and control of the high power amplifiers. The front panel mimic display shows the on-line amplifiers and the current switch positions. Dedicated fault lights are provided for easy indication of system status. All Redundant System Controller monitor and control is available locally, at the front panel LCD display, as well as remotely by the RS-232, RS-485 or Ethernet interface ports. Audible alarms and a full compliment of parallel I/O signal are available at the rear panel. 5 O2
Outline Drawing, 1:1 High Power Outdoor SSPA System with RCP2-1100 6 O2
Outline Drawing, 1:2 Compact Outdoor SSPA System with RCP2-1200 7 O2
PARADISE DATACOM RCP2-1100 1:1 REDUNDANT SYSTEM CONTROLLER Redundant Systems MODEL: S/N: P/N: L- RF OUT J2 J2 Outline Drawing, 1:1 Compact Outdoor SSPA System with RCP2-1100 8 O2
Part Number Configuration Matrix, GaAs High Power Outdoor Systems HPA C 2 4 0 0 A H M B S Band -Band C K Power Level (Watts) 400, 500, 600 -Band 350, 500 200, 250 Frequency Sub Band C 1 E 1 G 1 H J D 5.850 to 6.425 GHz 5.850 to 6.725 GHz 5.750 to 6.670 GHz 6.425 to 6.725 GHz 6.725 to 7.025 GHz 5.750 to 6.475 GHz 5.715 to 5.790 GHz 5.740 to 6.650 GHz -Band 7.90 to 8.40 GHz 7.70 to 8.40 GHz 14.00 to 14.50 GHz 13.75 to 14.50 GHz 12.75 to 13.25 GHz 1 Available with optional BUC Generation Second 2 B R 1 V Y 1 M P Configuration Modifier 3 Block Up Converter Internal Reference BUC External Reference BUC No BUC None () Configuration Modifier 2 Receive Band Reject Filter Reflected Power Monitor R + V (see above) 1 -Band units only Configuration Modifier 1 S Input Sample Port System Configuration 1:1 System, Input Switching, Internal control 1:1 System, Input Splitter, Internal control C 1 1:2 System, Input Switching, RCP2-1200 2 :1 System, Input Splitter, RCP2-1100 2 H 1 1:1 System, Input Switching, RCP2-1100 2 1 Input switching with an external reference BUC requires a reference distribution box. 2 cable length of 100 ft. (30m) with RCP unit. H Package High Power Outdoor SSPA Example - :1 Redundant System with Input Splitting and Internal Redundancy Control, using two (2) 400W GaAs High Power Outdoor SSPAs with optional input sample ports and optional internal reference block up converters is part number: HPAC2400AHMBS. 9 O2
Part Number Configuration Matrix, GaN High Power Outdoor Systems HPA C 2 8 0 0 A H M B G Band GaN Device Designator S-Band S G GaN Technology -Band C K Generation Second 2 Configuration Modifier 3 None () Power Level (Watts) S-Band 600, 800, 1000 (10K) 650, 800 -Band 650, 800 300, 400, 500 Frequency Sub Band A B G C 1 E 1 H L 1 D F C D 1 G S-Band 2.02 to 2.12 GHz 2.20 to 2.30 GHz 1.75 to 2.12 GHz 5.850 to 6.425 GHz 5.850 to 6.725 GHz 5.750 to 6.670 GHz 6.425 to 6.725 GHz 6.725 to 7.025 GHz 5.715 to 5.790 GHz 4.400 to 5.000 GHz -Band 7.90 to 8.40 GHz 7.70 to 8.40 GHz 7.10 to 7.40 GHz 14.00 to 14.50 GHz 13.75 to 14.50 GHz 14.50 to 14.70 GHz 15.10 to 15.40 GHz 12.75 to 13.25 GHz 14.75 to 15.25 GHz 1 Available with optional BUC R 1 V Y 1 Configuration Modifier 2 H Receive Band Reject Filter Reflected Power Monitor R + V (see above) 1 S-Band and -Band units only Configuration Modifier 1 S M P Input Sample Port System Configuration 1:1 System, Input Switching, Internal control :1 System, Input Splitter, Internal control C 1 1:2 System, Input Switching, RCP2-1200 2 :1 System, Input Splitter, RCP2-1100 2 H 1 1:1 System, Input Switching, RCP2-1100 2 1 Input switching with an external reference BUC requires a reference distribution box. 2 cable length of 100 ft. (30m) with RCP unit. Block Up Converter Internal Reference BUC External Reference BUC No BUC Package High Power Outdoor SSPA Example A 800W GaN (5.85 to 6.425 GHz) 1:1 Redundant High Power Outdoor SSPA System with input splitting, an internal reference block up converter and internal redundancy control is model number: HPAC2800AHMBG. 10 O2
Part Number Configuration Matrix, GaAs Compact Outdoor Systems HPA K 2 0 7 0 A C M B Band -Band C K Generation Second 2 A D F Configuration Modifier 3 None () Side-mount AC Input, Location A 48 VDC Input Side-mount 48 VDC Input, Location A Power Level (Watts) 030, 040, 050, 075, 100, 140, 200, 250, 300 025, 030, 060, 075, 100, -Band 140, 200, 250 010, 020, 025, 035, 040, 050, 070, 100, 125 Frequency Sub Band C 1 E 1 G 1 H J V 1,2 B D 5.850 to 6.425 GHz 5.850 to 6.725 GHz 5.750 to 6.670 GHz 6.425 to 6.725 GHz 6.725 to 7.025 GHz 5.750 to 6.475 GHz 5.715 to 5.790 GHz 5.740 to 6.650 GHz 5.850 to 6.725 GHz -Band 7.90 to 8.40 GHz 7.50 to 8.50 GHz 7.70 to 8.40 GHz 14.00 to 14.50 GHz 13.75 to 14.50 GHz 1 Available with optional BUC 2 With 1.3:1 VSWR C Package Compact Outdoor SSPA M R 1 S Configuration Modifier 2 MS-Connector Covers Receive Band Reject Filter M + R (see above) 1 -Band units only Configuration Modifier 1 K M P 110 VAC Input 1 Available in C- and -Band models 140W and models 100W System Configuration 1:1 System, Input Switching, Internal control :1 System, Input Splitter, Internal control C 1 1:2 System, Input Switching, RCP2-1200 2 :1 System, Input Splitter, RCP2-1100 2 H 1 1:1 System, Input Switching, RCP2-1100 2 1 Input switching with an external reference BUC requires a reference distribution box. 2 cable length of 100 ft. (30m) with RCP unit. Block Up Converter Internal Reference BUC External Reference BUC No BUC Example A 70W GaAs (14.0 to 14.5 GHz) 1:1 Redundant Compact Outdoor SSPA System with input splitting, an internal reference block up converter, and internal redundancy control is model number: HPAK2070ACMB. 11 O2
Part Number Configuration Matrix, GaN Compact Outdoor Systems HPA 2 3 0 0 A C M C G Band S-Band S C -Band Generation K Second 2 Power Level (Watts) S-Band 050, 100, 200, 300, 400, 500 300, 400 -Band 300, 400 100, 150, 200, 250 Frequency Sub Band GaN Device Designator G GaN Technology Configuration Modifier 3 None () A Side-mount AC Input, Location A Configuration Modifier 2 M MS-Connector Covers R 1 S Receive Band Reject Filter M + R (see above) 1 S-Band and -Band units only A B G C 1 E 1 H L 1 D F G S-Band 2.02 to 2.12 GHz 2.20 to 2.30 GHz 1.75 to 2.12 GHz 5.850 to 6.425 GHz 5.850 to 6.725 GHz 5.750 to 6.670 GHz 6.425 to 6.725 GHz 6.725 to 7.025 GHz 5.715 to 5.790 GHz 4.400 to 5.000 GHz -Band 7.90 to 8.40 GHz 7.70 to 8.40 GHz 7.10 to 7.40 GHz 14.00 to 14.50 GHz 13.75 to 14.50 GHz 12.75 to 13.25 GHz 14.75 to 15.25 GHz 1 Available with optional BUC C Package Compact Outdoor SSPA Configuration Modifier 1 M P System Configuration 1:1 System, Input Switching, Internal control :1 System, Input Splitter, Internal control C 1 1:2 System, Input Switching, RCP2-1200 2 :1 System, Input Splitter, RCP2-1100 2 H 1 1:1 System, Input Switching, RCP2-1100 2 1 Input switching with an external reference BUC requires a reference distribution box. 2 cable length of 100 ft. (30m) with RCP unit. Block Up Converter Internal Reference BUC External Reference BUC No BUC Use and Disclosure of Data The items described herein are controlled by the U.S. Government and authorized for export only to the country of ultimate destination for use by the ultimate consignee or end-user(s) herein identified. They may not be resold, transferred, or otherwise disposed of, to any other country or to any person other than the authorized ultimate consignee or end-user(s), either in their original form or after being incorporated into other items, without first obtaining approval from the U.S. government or as otherwise authorized by U.S. law and regulations. Proprietary and Confidential The information contained in this document is the sole property of Teledyne Paradise Datacom. Any reproduction in part or as a whole without the written permission of Teledyne Paradise Datacom is prohibited. Specifications are subject to change without notice. 12 O2