Silica polygonal micropillar resonators: Fano line shapes tuning by using a Mach-Zehnder interferometer

Similar documents
attosnom I: Topography and Force Images NANOSCOPY APPLICATION NOTE M06 RELATED PRODUCTS G

A novel tunable diode laser using volume holographic gratings

Wavelength-independent coupler from fiber to an on-chip cavity, demonstrated over an 850nm span

Design and Analysis of Resonant Leaky-mode Broadband Reflectors

Single-photon excitation of morphology dependent resonance

Highly sensitive silicon microring sensor with sharp asymmetrical resonance

High Sensitivity Interferometric Detection of Partial Discharges for High Power Transformer Applications

ABC Math Student Copy. N. May ABC Math Student Copy. Physics Week 13(Sem. 2) Name. Light Chapter Summary Cont d 2

Supplementary Information for. Surface Waves. Angelo Angelini, Elsie Barakat, Peter Munzert, Luca Boarino, Natascia De Leo,

Examination Optoelectronic Communication Technology. April 11, Name: Student ID number: OCT1 1: OCT 2: OCT 3: OCT 4: Total: Grade:

Phase Noise Modeling of Opto-Mechanical Oscillators

Optical RI sensor based on an in-fiber Bragg grating. Fabry-Perot cavity embedded with a micro-channel

Development of a Low Cost 3x3 Coupler. Mach-Zehnder Interferometric Optical Fibre Vibration. Sensor

Supplementary Figures

Silicon photonic devices based on binary blazed gratings

Realization of Polarization-Insensitive Optical Polymer Waveguide Devices

CHAPTER 5 FINE-TUNING OF AN ECDL WITH AN INTRACAVITY LIQUID CRYSTAL ELEMENT

EE119 Introduction to Optical Engineering Spring 2003 Final Exam. Name:

Stable dual-wavelength oscillation of an erbium-doped fiber ring laser at room temperature

2. Pulsed Acoustic Microscopy and Picosecond Ultrasonics

Controllable optical analog to electromagnetically induced transparency in coupled high-q microtoroid cavities

Wavelength-independent coupler from fiber to an on-chip cavity, demonstrated over an 850nm span. Steven Wang, Tal Carmon, Eric Ostby and Kerry Vahala

Temporal coherence characteristics of a superluminescent diode system with an optical feedback mechanism

Longitudinal mode selection in laser cavity by moiré volume Bragg grating

SIMULTANEOUS INTERROGATION OF MULTIPLE FIBER BRAGG GRATING SENSORS FOR DYNAMIC STRAIN MEASUREMENTS

Spectral phase shaping for high resolution CARS spectroscopy around 3000 cm 1

Silicon nitride based TriPleX Photonic Integrated Circuits for sensing applications

Chapter 17: Wave Optics. What is Light? The Models of Light 1/11/13

Mode analysis of Oxide-Confined VCSELs using near-far field approaches

Photonics and Optical Communication

Principles of Optics for Engineers

Infrared broadband 50%-50% beam splitters for s- polarized light

Chapter 10 WDM concepts and components

Electronically tunable fabry-perot interferometers with double liquid crystal layers

Opto-VLSI-based reconfigurable photonic RF filter

Guided resonance reflective phase shifters

Ring cavity tunable fiber laser with external transversely chirped Bragg grating

Optical Fibers p. 1 Basic Concepts p. 1 Step-Index Fibers p. 2 Graded-Index Fibers p. 4 Design and Fabrication p. 6 Silica Fibers p.

3550 Aberdeen Ave SE, Kirtland AFB, NM 87117, USA ABSTRACT 1. INTRODUCTION

All-Optical Signal Processing and Optical Regeneration

Optical Communications and Networking 朱祖勍. Sept. 25, 2017

Non-reciprocal phase shift induced by an effective magnetic flux for light

Electro-optic Electric Field Sensor Utilizing Ti:LiNbO 3 Symmetric Mach-Zehnder Interferometers

Impact of the light coupling on the sensing properties of photonic crystal cavity modes Kumar Saurav* a,b, Nicolas Le Thomas a,b,

Wave optics and interferometry

Sinusoidal wavelength-scanning interferometer using an acousto-optic tunable filter for measurement of thickness and surface profile of a thin film

Improving the output beam quality of multimode laser resonators

Experimental Competition

Narrowing spectral width of green LED by GMR structure to expand color mixing field

Spatial Investigation of Transverse Mode Turn-On Dynamics in VCSELs

Grating-waveguide structures and their applications in high-power laser systems

SUPPLEMENTARY INFORMATION

Physical Optics. Diffraction.

7 CHAPTER 7: REFRACTIVE INDEX MEASUREMENTS WITH COMMON PATH PHASE SENSITIVE FDOCT SETUP

Diffraction. Interference with more than 2 beams. Diffraction gratings. Diffraction by an aperture. Diffraction of a laser beam

Optical fiber-fault surveillance for passive optical networks in S-band operation window

High stability multiplexed fibre interferometer and its application on absolute displacement measurement and on-line surface metrology

Supplementary Figure 1. GO thin film thickness characterization. The thickness of the prepared GO thin

Chapter Ray and Wave Optics

CHIRPED FIBER BRAGG GRATING (CFBG) BY ETCHING TECHNIQUE FOR SIMULTANEOUS TEMPERATURE AND REFRACTIVE INDEX SENSING

ABSTRACT 1. INTRODUCTION

Thin-Core-Fiber-Based Long-Period Fiber Grating for High-Sensitivity Refractive Index Measurement

PHY 431 Homework Set #5 Due Nov. 20 at the start of class

Wavelength spacing tenable capability of optical comb filter using Polarization Maintaining Fiber

Supplementary information for Stretchable photonic crystal cavity with

Phy Ph s y 102 Lecture Lectur 22 Interference 1

Supporting Information: Plasmonic and Silicon Photonic Waveguides

A thin foil optical strain gage based on silicon-on-insulator microresonators

Photonic Microwave Harmonic Generator driven by an Optoelectronic Ring Oscillator

Pico-strain-level dynamic perturbation measurement using πfbg sensor

Lab 12 Microwave Optics.

Doppler-Free Spetroscopy of Rubidium

ADVANCES in NATURAL and APPLIED SCIENCES

Three-guide Coupled Rectangular Ring Lasers with Total Internal Reflection Mirrors

Cavity QED with quantum dots in semiconductor microcavities

Module 16 : Integrated Optics I

Miniature Mid-Infrared Thermooptic Switch with Photonic Crystal Waveguide Based Silicon-on-Sapphire Mach Zehnder Interferometers

Silicon-based photonic crystal nanocavity light emitters

Sinusoidal wavelength-scanning common-path interferometer with a beam-scanning system for measurement of film thickness variations

Fiberoptic and Waveguide Sensors

UNIT - 7 WDM CONCEPTS AND COMPONENTS

Physics 431 Final Exam Examples (3:00-5:00 pm 12/16/2009) TIME ALLOTTED: 120 MINUTES Name: Signature:

Fibre Optic Sensors: basic principles and most common applications

EE119 Introduction to Optical Engineering Fall 2009 Final Exam. Name:

Fang-Wen Sheu *, Yi-Syuan Lu Department of Electrophysics, National Chiayi University, Chiayi 60004, Taiwan ABSTRACT

Introduction to the operating principles of the HyperFine spectrometer

CHAPTER 2 POLARIZATION SPLITTER- ROTATOR BASED ON A DOUBLE- ETCHED DIRECTIONAL COUPLER

SUPPLEMENTARY INFORMATION

Frequency comb from a microresonator with engineered spectrum

Will contain image distance after raytrace Will contain image height after raytrace

Applications of Cladding Stress Induced Effects for Advanced Polarization Control in Silicon Photonics

Temperature-Independent Torsion Sensor Based on Figure-of-Eight Fiber Loop Mirror

Theoretical Analysis of Tunable Single-Core Comb Filter Based on MZI

NEW APPROACH TO DESIGN DIGITALLY TUNABLE OPTICAL FILTER SYSTEM FOR WAVELENGTH SELEC- TIVE SWITCHING BASED OPTICAL NETWORKS

LOS 1 LASER OPTICS SET

A miniature all-optical photoacoustic imaging probe

Supplementary Materials for

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science

Guided Propagation Along the Optical Fiber. Xavier Fernando Ryerson University

Printed Large-Area Single-Mode Photonic Crystal Bandedge Surface- Emitting Lasers on Silicon

Transcription:

Silica polygonal micropillar resonators: Fano line shapes tuning by using a Mach-Zehnder interferometer Kam Yan Hon and Andrew W. Poon Department of Electrical and Electronic Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong SAR, China Phone: 852-2358-7905, Fax: 852-2358-1485, email: eeawpoon@ust.hk ABSTRACT We experimentally demonstrate Fano resonance line shapes tuning by using a Mach-Zehnder interferometer (MZI). We employ a silica 125-µm-size hexagonal micropillar resonator with prism coupling in one arm of the interferometer, and a phase shifter together with a variable attenuator in the other arm. Our initial experiments reveal that the resonance line shapes observed at the interferometer output are characteristically asymmetric as Fano resonances. By using the phase shifter, we controllably tune the asymmetric line shapes from near-symmetric dip to near-symmetric peak and back to near-symmetric dip. We discuss potential applications of our MZI-based microresonator resonance line shapes tuning for bio-chemical sensing. Keywords: Fano resonances, resonance line shapes, micropillar resonators, Mach-Zehnder interferometer 1. INTRODUCTION Fano resonances 1 are ubiquitous in quantum and classical resonance systems. Fano resonances occur when a resonance pathway interferes with a coherent background pathway. The resultant resonance line shapes are characteristically asymmetric, often with a signature dip adjacent to the resonance, yet also exist in the form of a symmetric inverted Lorentzian. In optical systems, Fano resonances have long been recognized in grating diffraction and dielectric particles elastic scattering phenomena. Recently, optical Fano resonances have also been reported in various optical microcavities including integrated waveguide-coupled microcavities 2, prism-coupled square micropillar resonators 3,4, multimode tapered fiber coupled microspheres 5, and Mach-Zehnder interferometer (MZI) coupled microcavities. 6 It has been suggested that optical Fano resonances have niche applications in resonance line shape sensitive bio-sensing 7, optical channel switching and filtering 2-5. Previously 3,4, we reported experimental observations and modeling of Fano resonances in prism-coupled square micropillar resonators. We analyzed the observed singlemode asymmetric resonance line shapes in terms of interference between a single resonance mode and a coherent background 3, and the observed multimode asymmetric resonance line shapes in terms of interference between a high-q resonance mode and a detuned low-q resonance mode. 4 Here we report an experimental demonstration of Fano resonance line shapes tuning by using an MZI, as shown in Fig.1. We employ a prism-coupled silica hexagonal micropillar resonator to generate singlemode resonances in one arm of the interferometer, and a phase shifter together with a variable attenuator in the other arm. Our initial experiments show that the interferometer output exhibits Fano resonances and the line shapes can be controllably tuned from a near-symmetric dip to a near-symmetric peak. The paper is organized as follows: Section 2 reviews concept and modeling of optical Fano resonances. Section 3 presents principle and experiments of MZI-based Fano line shapes tuning. Section 4 discusses potential applications of controlled Fano line shapes tuning technique in (biochemical) sensing. Section 5 concludes the present work. Laser Beam Control and Applications, edited by Alexis V. Kudryashov, Alan H. Paxton, Vladimir S. Ilchenko, Adolf Giesen, Detlef Nickel, Steven J. Davis, Michael C. Heaven, J. Thomas Schriempf, Proc. of SPIE Vol. 6101, 61010V, (2006) 0277-786X/06/$15 doi: 10.1117/12.669567 Proc. of SPIE Vol. 6101 61010V-1

W!CLOLG2OUOL Output spectrum!ubfl U SUC VC onfbn Resonance dip Interference bpc JULj JWL)I!J.I IL. LFJ:iUUt Coherent background Figure 1: Illustration of Fano resonance asymmetric line shapes formation and tuning by using a Mach-Zehnder interferometer. One arm of the interferometer is coupled to a microresonator to generate a Lorentzian resonance field, whereas the other arm provides relative phase and amplitude control to the coherent background field. 2. OPTICAL FANO RESONANCES CONCEPT AND MODELING Asymmetric line shape We model optical Fano resonances in terms of light wave interference between an inverted Lorentzian resonance and a coherent background (Fig. 1). We express the interference between a unit-amplitude inverted Lorentzian resonance field E r and a coherent continuum background field E c as follows, E r + E c 2 = [ε / (ε 2 + 1)] exp iφ r + C exp iφ 2 (1) where ε = (λ λ o )/(Γ/2), λ o is the resonance wavelength in free space, Γ is the resonance linewidth, φ r = tan -1 ε, C is the relative amplitude of the background continuum, and φ is the relative phase of the continuum. We assume both C and φ are constants within a narrow spectral range. We expand the terms in (1) and obtain, E r + E c 2 = (q - ε) 2 / (1 + ε 2 ) + (C 2 - ε 2 ) cos 2 φ / (1 + ε 2 ) + (C + cos φ) 2 ε 2 / (1 + ε 2 ) (2) where q = C sin φ is the Fano asymmetry parameter. The first term of (2) is the well-known Fano line shape, whereas the second and third terms represent a symmetric Lorentzian and a symmetric inverted Lorentzian. Figure 2 shows the modeled asymmetric resonance lineshapes using (2), with λ o = 1558.42 nm, Q = 10 4, Γ = 0.156 nm, C = 1, for φ = 0, 0.5π, π, and 1.5π. Physically, the asymmetric resonance line shapes result from interference between the resonant field and the coherent continuum field with relative phase values 0 < φ < π. Whereas, the symmetric Lorentzian dip (φ = 0) results from a constructive interference between the inverted Lorentzian resonant field and the coherent continuum field. In contrast, the symmetric Lorentzian peak (φ = π) results from a destructive interference between the inverted Lorentzian resonant field and the coherent continuum field. It is worth mentioning that (2) results in characteristics distinguishable from those of standard Fano line shapes. At ε = q, (2) results in finite intensities, yet Fano line shapes given by (q - ε) 2 / (1 + ε 2 ) alone gives a zero-intensity. normalized intensity 4 3 2 1 φ = 0 φ = 0.5 π φ = 1.5 π φ = π 0 1557 1558 1559 1560 Figure 2: Modeled asymmetric resonance line shapes with φ = 0 (orange solid line), 0.5π (blue dashed line), π (red dashed line), and 1.5π (green dashed line). Proc. of SPIE Vol. 6101 61010V-2

3. FANO LINE SHAPES TUNING BY USING A MACH-ZEHNDER INTERFEROMETER Figure 3 illustrates Fano line shapes tuning by separately controlling φ and C using an MZI setup. Our interferometer comprises a resonance pathway given by a prism-coupled hexagonal micropillar resonator, and a coherent background pathway given by a phase shifter and a variable attenuator. Coherent background pathway Φ and C Phase shifter and variable attenuator Output Resonance pathway Input BS Prism Hexagonal micropillar resonator θ 60 ο Figure 3: Illustration of the use of prism-coupled hexagonal micropillar resonator in the resonance pathway and Fano line shapes tuning by separately controlling φ and C in the coherent background pathway. BS: beam splitter Comparing with conventional circular micropillar or microsphere resonators, polygonal micropillar resonators in the shape of square 3,4, hexagonal 8-10, and octagonal 11, have the key merit of flat cavity sidewalls for the ease of evanescent coupling along relatively long lateral interaction lengths. Hence, hexagonal micropillar resonators offer alternative microresonators to microresonator-based applications. Previously 9, we reported that hexagonal micropillar resonators exhibit resonances with 6-bounce ray orbits that are partially confined by total internal reflection at the six cavity sidewalls. Resonances occur only when the ray orbits are wavefront-matched with the input-coupled wavefronts upon each round trip. For a hexagonal micropillar resonator of a sidewall-to-sidewall distance a and a refractive index n, the wavefront-matched 6-bounce round-trip optical path length is given as 8,9 nl = n 3a sin (θ + 30 ο ), where θ is the ray incident angle. Figure 4 shows a schematic of our MZI-microresonator experimental setup. A TM-polarized (electric field parallel to the micropillar axis) Gaussian beam from an external-cavity wavelength-tunable diode laser (1510 nm 1580 nm; linewidth ~ 300 khz) is weakly focused by an f/81 spherical lens with a cone angle of about o ( 1/e 2 angular width). The laser beam is equally split by a 50/50 beam splitter. In one arm (the resonance pathway), the laser beam is focused onto a bulk fused-silica cylinder prism with an incident angle θ near 60 o. Such θ favors the input coupling to 6-bounce ray orbits 8,9. The illuminated prism is coupled to a commercially available fused-silica hexagonal optical fiber acting as a hexagonal micropillar resonator. The fiber sidewall and the prism flat surface are in contact near the prism origin. Inset (a) shows a top-view optical micrograph of the prism-coupled hexagonal fiber, with a 125 µm (sidewall length 72 µm) and six rounded corners. In the other arm (the coherent background pathway), we employ two right-angled gold-coated glass prisms (with one of the prisms mounted on a piezo-electric transducer) to form a phase shifter. We also use a polarization analyzer as a variable optical attenuator. We then separately control the relative phase φ and the relative amplitude C between the MZI arms. The piezo-electric transducer has a resolution of ~ 30 nm, and thus the Proc. of SPIE Vol. 6101 61010V-3

minimum delay increment is limited to ~ 60 nm (corresponding to φ ~ 2π*(60 nm) / (1550 nm) ~ 0.24 rad). Light beams from the two arms are recombined by another 50/50 beam splitter. The resultant interference fringe is sampled by a 62.5-µm core multimode fiber after an analyzer. We set the two arms optical path lengths to be nearly balanced. The spectral resolution is about 0.02 nm, which is only limited by the laser wavelength-tuning steps. Diode Laser BS (a) a = 125µm intensity (a.u.) 1.0 0.5 (c) tunable delay line for relative phase control Delay z: 60nm/step analyzer for amplitude control background path only 0.0 1550 1555 1560 BS biochemical sample Analyzer Prism coupled hexagonal micropillar resonator intensity (a.u.) 1.0 Fixed MM fiber to photodetector (b) Prism FSR ~ 4.5 nm 0.5 Q ~ 1.3 x 10 4 coupling ~ 66% A resonance path only 0.0 1550 1555 1560 Figure 4: Schematic of the Mach-Zehnder interferometer-based Fano line shapes tuning experimental setup. Inset (a) shows a top-view optical micrograph of the prism-coupled hexagonal fiber. Insets (b) and (c) show typical TM-polarized output spectra of resonance-only and background-only. BS: beam splitter, MM fiber: multimode fiber (62.5 µm core diameter) Insets (b) and (c) show typical measured TM-polarized interferometer output spectra obtained with the resonance path only and the background path only. The two spectra are set to approximately the same intensity (i.e. C ~ 1). The resonance-only spectrum reveals desirable singlemode resonances. The resonance line shapes are near symmetric inverted Lorentzian. The measured free spectral range (FSR) is about 4.5 nm, consistent with the calculated FSR λ 2 /(nl) 4.44 nm for a 6-bounce round-trip orbit with θ ~ 60º and n ~ 1.44, where λ (= 1558.42 nm) is the resonance wavelength in free space. Resonance A exhibits a Q ~ 1.3 x 10 4 and a coupling efficiency ~ 66%. The ripples in both spectra are due to residual etalon modulation within the laser diode. Figures 5(a) - 5(e) show our initially measured interferometer output spectra with controllably tuned Fano line shapes at various relative delays. Here we set the coherent background intensity to be approximately twice the resonance path intensity. We tune the asymmetric line shapes from near symmetric dip to near symmetric peak and return to near symmetric dip. Fano asymmetric line shapes are discerned in Figs. 5(b) and 5(d). Proc. of SPIE Vol. 6101 61010V-4

1.0 (a) A delay = 0 nm (b) intensity (a.u.) 0.3 0.2 0.1 0.3 (c) (d) 120 nm 420 nm 540 nm 0.2 (e) 960 nm 1556 1558 1560 1562 1564 Figure 5: Initially measured resonance line shapes tuning. The coherent background intensity is approximately twice the resonance path intensity and the delay (a) 0 nm, (b) 120 nm, (c) 420 nm, (d) 540 nm, and (e) 960 nm. 4. POTENTIAL APPLICATIONS IN BIOCHEMICAL SENSING AND COMPARISON WITH RELATED TECHNIQUES Based on our initial experimental demonstration, we believe that by inserting a sample cell in the coherent background path (see Fig. 4), our resonance line shapes tuning technique should be applicable for sensing small phase shifts due to the presence of a certain biochemical content in the cell. Conventionally, interferometry has long been employed for sensing small relative phase shifts. By inserting a (biochemical) sample into one arm of an MZI, the phase change can be represented as an intensity variation in the interferometer output. This conventional approach has an advantage that the sample can be readily inserted and removed from the interferometer arm. However, the free space interferometer arms alignment may be problematic and prone to mechanical instabilities. Recently, high-q microresonator-based sensing 7 has attracted much research interest. When this method is applied for biochemical sensing, it imposes coating the entire microresonator with a thin-film of sample in order to induce an effective refractive index change that results in resonance wavelength shifts. The key merit is that an ultra high-q microresonator (e.g. Q ~ 10 6 or beyond) offers an ultra-high sensitivity. However, the drawback is that the microresonator needs to be thoroughly cleaned or disposed after use. Furthermore, the sensor performance can also be limited by the laser wavelength instability, and hence a precision laser wavelength monitoring should be desirable. Proc. of SPIE Vol. 6101 61010V-5

By contrast, we believe that our MZI-based microresonator technique offers essentially an interferometric method for sensing, yet with the potential benefit of using the asymmetric resonance line shapes change as an additional measure, which is less affected by laser wavelength instabilities. Here we contrast more quantitatively our proposed technique for (biochemical) sensing with conventional interferometric method using MZI. We assume a refractive index shift Δn = 10-4 (n = 1.33). We consider the sample has a thickness of 1 mm, resulting in a phase shift φ of ~ 0.4 rad (at 1558.47 nm). Following the measured spectra (Fig. 5), we assume a resonance wavelength at 1558.42 nm with a resonance Q ~ 10 4. Using (2), we calculate the resonance line shapes with C = 1 and φ = π/2. Figure 6(a) shows the calculated asymmetric resonance line shape change under the phase shift of 0.4 rad. We note that the calculated intensity change at an off-resonance wavelength is essentially the same as conventional MZI response. We believe that the resonance line shape change is favorable for sensing applications. normalized intensity 3 2 1 (a) φ = π/2 + 0.4 0 1557.5 1558.0 1558.5 1559.0 1559.5 φ = π/2 normalized intensity 4 3 2 1 0 (b) MZI (i) (ii) (iii) 0.0 0.5 1.0 1.5 2.0 φ (π) Figure 6: (a) Calculated Fano line shapes at φ = π/2 (blue solid line) and φ = π/2 + 0.4 (red dashed line). (b) Calculated intensity with relative phase at various probe wavelengths (i) 1558.45 nm (blue dotted line), (ii) 1558.47 nm (resonance wavelength, black dotted line), (iii) 1558.49 nm (red dashed line), and (iv) 1560.00 nm (off-resonance wavelength, green solid line). The MZI intensity response (purple dashed line) is shown for comparison. (c) Initially measured intensity as a function of delay at various probe wavelengths (i) 1558.38 nm (squares), (ii) 1558.40 nm (circles), (iii) 1558.42 nm (triangles),and (iv) 1560.42 nm (inverted triangles). Figure 6(b) shows the calculated intensity against φ for our proposed technique at various wavelengths and for conventional MZI sensing. At an off-resonance wavelength, our technique matches that of conventional MZI-only method. However, with the probe wavelength approaches the resonance wavelength, our proposed method exhibits less sensitivity to relative phase shifts than conventional MZI. The phase response becomes flat at the resonance wavelength. Although our proposed approach only displays sensitivity as good as a conventional MZI, we believe that the flat response at a resonance wavelength offers a unique reference that is fixed in intensity under any degree of relative phase shifts. We could then have a MZI-based sensing technique that has a self-reference at the resonance wavelength. Figure 6(c) shows our analysis of the initially measured spectra (Fig. 5) in terms of the measured intensities as a function of delay (phase shift) at various probe wavelengths near resonance A. However, unlike our modeling, the response curves measured near the resonance wavelength still display considerable modulations. Moreover, the response curves fail to display the expected π-phase shifted oscillations in our modeling (shown in Fig. 6(b)). Instead, all the extracted response curves essentially follow the same modulation. We attribute the modulation to perhaps a MZI-dominant effect results from possible alignment issues. Further experiments are needed to confirm our modeled Fano line shapes tuning and to substantiate the proposed technique as a useful MZI-microresonator based biosensing method. 5. CONCLUSION 0.0 0 300 600 900 1200 We experimentally demonstrated controlled Fano line shapes tuning in prism-coupled silica hexagonal micropillar resonators using a Mach-Zehnder interferometer. Our experimental setup reveals singlemode resonances (Q ~ 1.3 x10 4 ) in hexagonal micropillar resonators that are input and output coupled near 60 o. The sharp resonance line shapes (vi) intensity 1.0 0.4 0.2 (c) (iv) delay (nm) (iii) (ii) (i) Proc. of SPIE Vol. 6101 61010V-6

observed in the interferometer output are characteristically asymmetric. By controlling the interfering coherent continuum field relative amplitude and relative phase, we demonstrated 2π asymmetric resonance line shapes tuning. We believe that our technique of controlled resonance line shapes tuning deserves further investigation for potential applications in biochemical sensing as an alternative approach to conventional interferometric and microresonator-based methods. ACKNOWLEDGEMENTS This study was substantially supported by grants from the Research Grants Council of the Hong Kong Special Administrative Region, China (projects HKUST6166/02E & 618505). REFERENCES 1. U. Fano, Effect of configuration interaction on intensities and phase shifts, Phys. Rev. 124, 1866 (1961). 2. S. Fan, Sharp asymmetric line shapes in side-coupled waveguide-cavity systems, Appl. Phys. Lett. 80, 908 (2002). 3. H.T. Lee and A. W. Poon, Fano resonances in prism-coupled square micropillars, Opt. Lett. 29, 5 (2004). 4. H.T. Lee, L. Zhou, and A. W. Poon, Fano resonances in prism-coupled multimode square micropillar resonators, Opt. Lett. 30, 1527 (2005). 5. A. Chiba, H. Fujiwara, J.-I. Hotta, S. Takeuchi, and K. Sasaki, Fano resonance in a multimode tapered fiber coupled with a microspherical cavity, Appl. Phys Lett. 86, 261106 (2005). 6. Y. Lu, J. Yao, X. Li, and P. Wang, Tunable asymmetrical Fano resonance and bistability in a microcavity-resonator-coupled Mach-Zehnder interferometer, Opt. Lett. 30, 3069 (2005). 7. C. Y. Chao and L. J. Guo, Biochemical sensors based on polymer microrings with sharp asymmetrical resonance, Appl. Phys. Lett. 83, 1527 (2003). 8. N. Ma, C. Li, and A. W. Poon, Laterally coupled hexagonal micropillar resonator add-drop filters in silicon nitride, IEEE Photon. Technol. Lett. 16, 2487 (2004). 9. N. Ma, F. K. L. Tung, S. F. Lui, and A. W. Poon, Hexagonal micro-pillar cavities: multimode resonances and open-loop resonance linewidth broadening, in Physics and Simulation of Optoelectronic Devices XI, Marek Osinski, Hiroshi Amano, Peter Blood ed., Proc. SPIE 4986, 153 (2003). 10. J. Wiersig, Hexagonal dielectric resonators and microcrystal lasers, Phys, Rev. A. 67, 023807 (2003). 11. C. Li and A. W. Poon, Experimental demonstration of waveguide-coupled round-cornered octagonal microresonators in silicon nitride, Opt. Lett. 30, 546 (2005). Proc. of SPIE Vol. 6101 61010V-7