DatasheetDirect.com. Visit to get your free datasheets. This datasheet has been downloaded by

Similar documents
118, 128, KEELOQ REMOTE CONTROL SYSTEMS, 12 / 24Vdc,

Modular Radio Telemetry System

Modular Radio Telemetry System

FIREFLY FIREBLADE RADIO REMOTE CONTROL SYSTEMS. Applications

200, 201 Series Radio Telemetry Transmitters

PRO Professional Radio Control Series Applications

PROFLY / PROBLADE Professional Radio Control PRO-BLADE8

AM / FM RADIO TRANSMITTER KEYFOBS

VIPER Remote Control Systems

105 SERIES REMOTE RECEIVER DECODERS

Radio Encoder / Decoder IC s

Remote Switching. Remote Gates. Paging.

Remote Switching. Remote Gates. Paging.

RF RECEIVER DECODER RDF1. Features Complete FM Receiver and Decoder. Applications

HORNET Remote Control Systems

MINIATURE AM / FM DECODER MODULES

SABRETrap Control. Description

FM-RRFQ SERIES FM TRANSMITTER & RECEIVER HYBRID MODULES. Transmitter. Receiver. Applications

FM-RTFQ SERIES FM-RRFQ SERIES FM TRANSMITTER & RECEIVER HYBRID MODULES. Transmitter. Receiver. Applications

ALPHA Encoder / Decoder IC s

Trap Series. Features: Description. Technologically Advanced: 2Km Range Protective Rubber Boot 1, 4 and 16 Switch versions

SmartRadio Transmitter / Receiver

FM Radio Transmitter & Receiver Modules

DUAL BAND FM WIRELESS TRANSCEIVER RXQ1. Applications

TRXQ1 RXQ1 FM NARROW BAND TRANSCEIVERS. RXQ1 Version. Applications. TRXQ1 Version

SmartRadio control system

SMARTALPHA RF TRANSCEIVER

QM Radio Transmitter Module

BRAVO. SmartRadio Telemetry Module

FM 433MHz Narrow Band

KAPPA-T868SO. Smart Radio Telemetry Module

FM Radio Transmitter & Receiver Modules

FOBBER - FM Key Fob. Description. FM (FSK) Key fob Sleek and compact design Range up to 200metres 1-8 Switch variants 433 / 868MHz Options

RF / IR Encoder / Decoder Chipset RF Eval2 Board, (SA123)

FMR ELSEMA 1-Channel 151MHz Receiver - FMR15101

RF / IR Encoder / Decoder Chipset RF Evaluation Boards,

FMR ELSEMA 2-Channel 151MHz Receiver - FMR15102

FM TRANSMITTER & RECEIVER MODULES. (2ND GENERATION) FM-TX2-XXX FM-RX2-XXX FEATURES. Receiver - RX2. Transmitter - TX2. Description

Arduino Arduino RF Shield. Zulu 2km Radio Link.

HURRICANE Radio Modem. FULL DUPLEX Radio MODEM

RF Remote Control Unit SEAV

Revision RK-433-RC USER S MANUAL

Operating Instructions

Radio Control Installation and Operating Instructions System 4

eguard EG2233, EG3333, EG3355, EG3388 & EG8406: Installation and Set-up Procedures Tx 2200 and Rx 4200 Boards

SF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

KAPPA M. Radio Modem Module. Features. Applications

Videowave Wireless Video & Telemetry VTX1394SED & VRX1394SED

INSTRUCTION MANUAL PLUG AND SEND WIRELESS MONITOR SYSTEM TABLE OF CONTENTS

FMT15101E, FMT15102E, FMT15104E, FMT15108E (Enclosed version) FMT15101, FMT15102, FMT15104, FMT15108 (No Case version)

FMT15101E, FMT15102E, FMT15104E, FMT15108E (Enclosed version) FMT15108 (No Case version)

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

ENCODING PHOTOCELLS MF6

Ness MCR Multi-Channel Radio Receiver

ET RXTX-RC Weatherproof Repeater Version 2011/010. Specifications. Encryption: Rolling Code. Frequency: MHz

ELSEMA 1-Channel 433MHz Receiver with 16A Relay Output- GLR

Langton House, 19 Village Street, Harvington, Worcestershire. WR11 8NQ Tel: Fax: RTB5211 UHF FULL DUPLEX BASE STATION

4 Channel RF Remote Controller with Momentary Outputs

FMR Description

User Manual. ProRF Encoder Transmitter & Receiver

AR-DN-RS232. An-10 / Rapid RS232 Interface. Product Guide. Overview. Features

HL 670 Data / Impulse Transmitter set User Manual. Version 07/2010

IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

SF Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

SF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

CTA88 remote control chip Application boards

MCR91501R 1-Channel, 915MHz Receiver with Frequency Hopping

Description. Block Diagram

4612 Reference Guide

DTMF decoder kit with 8 outputs and Morse transpond. 8 output DTMF decoder with 4 on board BT47 style 12V relays and 4 open collector outputs

ELSEMA 1,2,3,4,8 -Channel 433MHz GIGALINK Transmitter GLT43300,GLT43301,GLT43302,GLT43303,GLT43304,GLT43308

Blue Point Engineering Inc.

GLR43308 and GLR2708. Setup and programming instructions. for the 8 channel Gigalink receiver. Programming Videos

Radio receivers type DB317 and DBR1-M4

Astra-R Kit Wireless Alarm System Operation Manual

HL 675 Data / Impulse Transmitter set User Manual

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED. READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION.

FMR MHz Receiver with Two Relay Outputs

PRODUCT MANUAL VHF & UHF Pocket Paging Transmitter. Version 1.00 April 2017

K580M GUIDA ALL INSTALLAZIONE INSTALLATION GUIDE INSTALLATIONSANLEITUNG NOTICE D INSTALLATION GUÍA PARA LA INSTALACIÓN

UNIT A 8-30VDC 8-28VAC POWER V IN3 IN4 COM1/2 NO3 NO4 IN1 IN2 GND NO1 NO2 COM3/4 ANY 8-28VAC OR 8-30VDC POWER ADAPTER (SOLD SEPARATELY)

ELSEMA GLR Applications Automatic gates. Security systems. Timer controlled outputs. Simple on/off functions.

Blue Point Engineering Inc.

Lazerpoint TM RF RX-91 Basic Receiver Installation Instructions

The combination of FFH and MCR technology brings you a very sophisticated receiver yet easy to use.

MODEL NC221 MOBILE TWO-TONE SEQUENTIAL DECODER INSTRUCTION MANUAL

INMOTION Controls Series INSTALLATION & OPERATION MANUAL. INMOTION Series - INMOTION INMOTION-260. Page: 1/15

MCR91508POS 8 Channel receiver with 8 positive output switching

4 CHANNEL TWISTED PAIR CABLE Rs485 BASED REMOTE CONTROLLER

ST12 CODEC IR/RF Remote Control Encoder/Decoder IC 1. Overview

ELSEMA 1,2,3,4,8 -Channel 433MHz GIGALINK Transmitter GLT43300,GLT43301,GLT43302,GLT43303,GLT43304,GLT43308

ELSEMA 1,2,3,4,8 -Channel 433MHz,25mWatt Transmitter

TVP2 PERFORMANCE TEST TAG MANUAL

LAMBDA. LongRange (LoRa) Transceiver. Features. Applications. Description

TONE ALERT RECEIVER MODEL 2TR9A. P.O. Box West Pacific. Lexington, NE 68850

WBS-670/680. Powerful Features and Performance. For Reliable Mobile Communications WBS-670 WBS-680

P700WLS IoProx Receiver

Transmitters & Receivers

OEM KEYFOB TRANSMITTER DATA GUIDE

Series 3000 Model R-107A

Transcription:

DatasheetDirect.com Your dedicated source for free downloadable datasheets. Over one million datasheets Optimized search function Rapid quote option Free unlimited downloads Visit www.datasheetdirect.com to get your free datasheets. This datasheet has been downloaded by http://www.datasheetdirect.com/

REMOTE DECODER; RADIO, INFRA-RED, PAGER 4 RELAY CHANNELS EXPANDABLE TO 15 RADIO FREQS; 433 / 458 / 868 MHz IP65 RATED ENCLOSURE EASY INSTALLATION VIA SCREW TERMINALS 230VAC OR 12-30VDC SUPPLY 15 CMOS/TTL CHANNEL O/P's LED INDICATION OF EACH RELAY OUTPUT. MOMENTARY OR LATCHING OUTPUTS 1 TIMED OUTPUT ADJUSTABLE 0 To 255 secs RELAY CONTACTS 2.5A @ 240VAC REQUIRES NO RADIO LICENCE DESCRIPTION A general-purpose Rx decoder which may operate as radio, infra-red or pager system. The unit is supplied in a tough ABS enclosure with IP65 rating, complete and ready to operate. As a pager system (using Globemaster Module G100UK), the unit is a stand-alone pager controller. As a radio or infrared Rx decoder, the system may be supplied with one of several modules to enable the user to choose the optimum frequency modulation and range. The Rx decoder has a self-learning feature, which enables it to learn the signature code of up to 50 individual RF Solutions KEELOQ Tx encoders. Connections to the power supply and relay outputs are provided through screw terminals (these are the only connections required). The output relays are rated 2.5A @ 240Vac operating as either momentary of latched operation. An additional Low battery LED and relay is also provided to indicate that the Tx encoder battery voltage is low. Output 1 has a variable time feature, which may be adjusted to give a timed output (upto 4 minutes). A further 15 momentary digital channels are also provided for expansion using the 115 Expander (See datasheet DS115). Performance Table Modulation RF uency Transmit Output Power (mw) Range ** Infra-Red - - 20 AM 433 10 45 AMS 433 10 100 FM 433 10 200 FMNB 433NB 10 800 FM 458 500 3,000 Globemaster See Datasheet DS100 The UK ** Range stated is optimum, direct line of sight. In worst conditions this can be reduced by upto 50% (m) DS105_3 Feb 01 2001 Reg. No. 227 4001, ENGLAND Page 1

Connections ANT SW1 LEARN SWITCH GND POWER LED LEARN LED BATT LOW LED J3 J7 J2 Connector to Expander J14 INFRA-RED HEADER VR1 RF RECEIVER / PAGER CH4 CH2 RLY 9 RLY 1 RLY 2 RLY 3 MAINS TRANSFORMER CH3 J9 J10 J11 J12 D8 D7 D10 D9 T1 F1 E N L 230Vac Mains 0V 12-30 Vdc CH4 RLY 4 J4 J5 The decoder requires either a single 12-30 Vac supply or 240Vac mains. NOT BOTH! N/O COMM N/C N/O COMM N/C N/O COMM N/C N/O COMM N/C N/O COMM N/C LOW BATT O/P1 O/P2 O/P3 O/P4 Warning! The unit is designed to be a fixed installation, which may be connected to a mains supply. Before removing the cover ensure that the mains input supply is removed. Any operation of the product that involves removal of the front cover should only be carried out by a competent person or qualified electrician. Configuration the (Jumper Links J2, J3) These links configure the operation of the digital outputs according to the table below. NOTE: The link status is read only on power up, after changing the links please to remove and re-apply power. The system is supplied with relay(s) type OMRON GL5114P or equivalent. Note: The user must ensure that the load connected does not overload the relay! J2 J3 RL 1 RL 2 RL 3 RL 4 Open Open Latch Latch Latch Latch Open Connected Timed Momentary Momentary Momentary Connected Open Latch Latch Momentary Momentary Connected Connected Timed Momentary Latch Latch Latch: The relay operates until the next valid transmission is received Momentary: The relay operates momentarily, or for as long as the Tx encoder switch is held on. Removing Timed Output: Turn the trimmer (VR1) fully anti Clockwise. Timed Output (O/P1) This is a variable timed output controlled by VR1. This may be adjusted from no delay to a maximum of 4 minutes 15 seconds. Turning VR1 clockwise increases the output delay. To remove the timed delay (for either momentary or latching mode) turn the trimmer fully anti-clockwise. DS105_3 Feb 01 2001 Reg. No. 227 4001, ENGLAND Page 2

Low Battery The low battery feature informs the user that the Tx encoder used has a low voltage battery. The LOW BATT channel operates if the Rx decoder has received a transmitted signal with low voltage signal present. This will continue to operate until a transmitted signal without the low voltage signal has been received. NOTE: the LOW BATT relay is type BT47W/6 or equivalent. Expanding the system to 15 outputs The EX115C16A unit is available to connect directly to the 105 Series Decoder providing 15 momentary relay outputs. For further information please see Datasheet DS115. LEARNING A NEW TX ENCODER 1. Press and release the programming switch (PSW1) 2. Note that the LED will illuminate 3. Depress and release the transmitter once, LED on the decoder will extinguish 4. Depress and release the transmitter again, LED on the decoder will flash 5. After the LED has stopped flashing the transmitter has been successfully taught to the decoder 6. This transmitter will now operate the system 7. To completely erase the transmitters, press PSW1 on the decoder for 10 seconds. The LED will turn off after the 10 seconds to indicate that the transmitter(s) have been erased ERASING EXISTING TX ENCODER 1. To completely erase the Tx encoders, press SW1 on the Rx decoder for 10 seconds. 2. The learn LED will turn off after the 10 seconds to indicate the Tx encoder(s) have been erased NOTE: You can not erase individual Tx encoders **Range Please note that all radio systems are dependant on a radio signal being received through airspace. The range quoted is the optimal in direct line of sight without obstacles and in good atmospheric conditions. Range is affected by many things, e.g. local environmental conditions, atmospheric conditions, interference from other radio transmitters. In very worse case applications the range quoted may be reduced to 10% of the optimal range stated. Technical Specifications Dimensions: Enclosure : 190 x 120 x 60 mm (PCB: 174 x 106mm) Storage Temperature; -10 to +70 o Celsius. Operating Temperature; 0 to +55 o Celsius. ELECTRICAL CHARACTERISTICS MIN TYPICAL MAX DIMENSION Supply Voltage 11.0 12.0 30.0 V Supply Current : Quiescent 25 ma Time from Encoder Switch depressed to Decoder 100 msecs output change Time from Encoder Switch release to Decoder output 300 msecs change All s operating 400 ma Rating (240Vac) RLY1-4 2.5 5 A Low Battery Rating (RLY9) 2 A @12Vdc DS105_3 Feb 01 2001 Reg. No. 227 4001, ENGLAND Page 3

ing AM105 Series Decoders AM-105C3A-433 3 433.92 AM-Superegen Decoder 45 AM-030 Series AMS105 Series Decoders AMS-105C3A-433 3 433.92 AM-SupHet Decoder 80 AM-110 Series FM105 Series Decoders FM-105C4A-433 4 433.92 FM 200 FM-105C4A-433NB 4 433.92 FM-105C4A-458 4 458.850 FM 433 Narrow Band Radio Modules for increased Range Long Range Remote Control 800 FM-102, FM-103, FM-107 Series FM-102NB, FM-103NB Series 5000 FM-103, FM-107 Series IR105 Series Decoders IR-105C4A-433 4 N/A Infra-Red Receiver Decoder 4 output relays 20 IR106, IR-102, Series G105 Series Decoders G100-105C4A 4 N/A Pager Based Unit The UK Any DTMF Telephone ** Range stated is optimum, direct line of sight. In worst conditions this can be reduced by upto 50% For more information or general enquiries, please contact R. F. Solutions Ltd., Unit 21, Cliffe Industrial Estate, South Street, Lewes, E Sussex, BN8 6JL. England Tel +44 (0)1273 898 000 Fax +44 (0)1273 480 661 Email sales@rfsolutions.co.uk http://www.rfsolutions.co.uk RF Solutions is a member of the Low Power Radio Association All Trademarks acknowledged and remain the property of the respected owners Information contained in this document is believed to be accurate, however no representation or warranty is given and R.F. Solutions Ltd. assumes no liability with respect to the accuracy of such information. Use of R.F.Solutions as critical components in life support systems is not authorised except with express written approval from R.F.Solutions Ltd. DS105_3 Feb 01 2001 Reg. No. 227 4001, ENGLAND Page 4