General Information. * Required

Similar documents
APPENDIX 1 to LGIP INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

Generation Interconnection Study Data Sheet Synchronous Machines

NORTH CAROLINA INTERCONNECTION REQUEST. Utility: Designated Contact Person: Address: Telephone Number: Address:

IDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form)

Issued: September 2, 2014 Effective: October 3, 2014 WN U-60 Attachment C to Schedule 152, Page 1 PUGET SOUND ENERGY

INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

Connection Impact Assessment Application Form

GENERATOR INTERCONNECTION APPLICATION Category 5 For All Projects with Aggregate Generator Output of More Than 2 MW

Form B. Connection Impact Assessment Application Form Distribution System

Initial Application Form for Connection of Distributed Generation (>10kW)

PART 1 OWNER/APPLICANT INFORMATION

SOUTH CENTRAL INDIANA REMC Application for Operation of Member-Owned Small Power Generation Systems

EASTERN ILLINI ELECTRIC COOPERATIVE Application for Operation of Member-Owned Generation

Embedded Generation Connection Application Form

Embedded Generation Connection Application Form

Owner/Customer Name: Mailing Address: City: County: State: Zip Code: Phone Number: Representative: Address: Fax Number:

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 2 MW

APPLICATION FOR INTERCONNECTION & OPERATIONS OF MEMBER-OWNED GENERATION

Impact Assessment Generator Form

ENGINEERING DATA SUBMITTAL For the Interconnection of Generation System

Connection Impact Assessment Application

GENERATOR INTERCONNECTION APPLICATION Category 3 For All Projects with Aggregate Generator Output of More Than 150 kw but Less Than or Equal to 550 kw

Embedded Generation Connection Application Form

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 150 KW BUT LESS THAN OR EQUAL TO 550 KW

REQUIREMENTS FOR GENERATING FACILITY INTERCONNECTION TO THE LIPA TRANSMISSION SYSTEM

State of North Dakota Engineering data submittal Page 1 For interconnection of distributed generation to Otter Tail Power Company

Remotes Case 2&3 Form REINDEER Cases 2&3 -Connection Impact Assessment (CIA) Application

ECE 422/522 Power System Operations & Planning/Power Systems Analysis II 5 - Reactive Power and Voltage Control

APPENDIX B: Generation Interconnection Application Form

Distributed Generation Application Form (Generation of Greater than 20 kw to 15 MW)

System Protection and Control Subcommittee

Time constants ( s ) Resistance. Other data - Class H /6600 V kva. Efficiencies ( % )(3 phase - Classe H V kva)

ALTERNATOR TECHNICAL DESCRIPTION 1. LSA 53.2 XL13 / 4p. Chargé d'affaire : Karthikeyan GN 1 Moteurs Leroy-Somer +33 (0) xx

Power Plant and Transmission System Protection Coordination of-field (40) and Out-of. of-step Protection (78)

Facility Interconnection Requirements for Colorado Springs Utilities Version 03 TABLE OF CONTENTS

S0L1-J1 - Technical Data Sheet

Document C-29. Procedures for System Modeling: Data Requirements & Facility Ratings. January 5 th, 2016 TFSS Revisions Clean Open Process Posting

Setting and Verification of Generation Protection to Meet NERC Reliability Standards

OPERATING, METERING AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 25,000 KILOWATTS

Short-circuit behavior - Xd ; s-s, transient, subtransient. Chapter 4 - Series Resistance of Transmission Lines

S4L1S-D4 Wdg.17 - Technical Data Sheet

Imperial Irrigation District System Planning ATTACHMENT A

Kestrel Power Engineering

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 5: (August 2, 2013) Page 1 of 76

Spec Information. Reactances Per Unit Ohms

IJSER. Fig-1: Interconnection diagram in the vicinity of the RajWest power plant

Code No: R Set No. 1

NERC Protection Coordination Webinar Series June 30, Dr. Murty V.V.S. Yalla

S4L1D-G41 Wdg Technical Data Sheet

Robert W. Cummings - NERC Director of System Analysis and Reliability Initiatives William Herbsleb - Chairman of Frequency Response Standard Drafting

Course ELEC Introduction to electric power and energy systems. Additional exercises with answers December reactive power compensation

GENERATOR DATA JANUARY 30, 2015

OPERATING, METERING, AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 2,000 KILOWATTS

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 4: (June 10, 2013) Page 1 of 75

SYNCHRONOUS MACHINES

Generator Advanced Concepts

System Protection and Control Subcommittee

AGN 034 Alternator Reactance

NERC Protection Coordination Webinar Series July 15, Jon Gardell

How Full-Converter Wind Turbine Generators Satisfy Interconnection Requirements

WDG 83 - Technical Data Sheet

Southern Company Interconnection Requirements for Inverter-Based Generation

LONG ISLAND POWER AUTHORITY INTERCONNECTION GUIDE FOR INDEPENDENT POWER PRODUCERS

PM734D - Winding 312. Technical Data Sheet APPROVED DOCUMENT. Generator Solutions AS

PM734F - Winding 312. Technical Data Sheet APPROVED DOCUMENT

HISTORY: How we got to where we are. March 2015 Roy Boyer 1

NERC Requirements for Setting Load-Dependent Power Plant Protection: PRC-025-1

NERC Protection Coordination Webinar Series June 16, Phil Tatro Jon Gardell

PM734B - Technical Data Sheet. Generator Solutions AS

Power Plant and Transmission System Protection Coordination

WDG 13 - Technical Data Sheet

Conventional Paper-II-2013

1

EH2741 Communication and Control in Electric Power Systems Lecture 2

PI734E - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734C - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734B - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734C - Technical Data Sheet

WDG 71 - Technical Data Sheet

PI734A - Technical Data Sheet

WDG 61 - Technical Data Sheet

WDG 51 - Technical Data Sheet

QUESTIONNAIRE for Wind Farm Power Stations only

WDG 12 - Technical Data Sheet

WDG 12 - Technical Data Sheet

PAPER-II (Subjective)

PI734F - Winding 28. Technical Data Sheet APPROVED DOCUMENT

Transmission Interconnection Requirements for Inverter-Based Generation

Transformer Protection

WDG 12 - Technical Data Sheet

NERC Protection Coordination Webinar Series June 23, Phil Tatro

If any queries arise ESB Networks DAC can be contacted at or

WDG 12 - Technical Data Sheet

IJSER. Rajasthan power system power map is placed in Fig-1. Fig-1: Rajasthan Power System

WDG 07 - Technical Data Sheet

Appendix C-1. Protection Requirements & Guidelines Non-Utility Generator Connection to Okanogan PUD

Power Plant and Transmission System Protection Coordination

Planners Perspective on Series Compensated Transmission Lines

PI734F - Winding 07. Technical Data Sheet APPROVED DOCUMENT

Company Directive STANDARD TECHNIQUE: SD7F/2. Determination of Short Circuit Duty for Switchgear on the WPD Distribution System

Transcription:

General Information * Required General * Plant Name * Company Name * Name of individual completing data * Email of individual completing data * Phone of individual completing data * Has any data in any sheet changed from previous year * PJM TO area * Plant code * Commercial Operation Year * Prime Mover Code * Ownership Code Location * County * City * State * Zip Energy Source Code * A B C D

E Generator Capability * Name Plate (MW) * Unit Maximum (MW) * Unit Minimum (MW) * Total Gross Energy Summer Winter * Auxiliary load (MW) * Auxiliary load (MVAR) * Station Load (MW) * Station Load (MVAR) Total Reactive Power Capability at Max Gross Energy Output * Leading (MVAR) * Lagging (MVAR)

Auxiliary Loads are those loads related to the operation of a specific generator. Fox example any fans or pumps etc. The station load is also known as house load. These are loads related to the facility where the power plant is located but not related to the operation of the power plant. This tends to be constant. Underexcited Overexcited

Synchronous Gen Parameters * Required * Want to submit data for a Synchronous Generator? Please Select... Provide individual generator capability (All values requested here are for individual units) * Machine ID (e.g. ST, CT, CT1, CT2, ST2, etc.): Note: List all the machine IDs that these data corresponds (e.g. CT1, CT2). * MVA base: * Terminal voltage: * Nominal power factor: * Unit maximum net capacity output (unit CIR): * Unit gross energy output: * Unit reactive power capability at max gross energy output - leading: * Unit reactive power capability at max gross energy output - lagging: Unit auxiliary load at max gross energy power output: * Where is the auxiliary load being connected? Please provide diagram illustrating aux load configuration. * Any additional comments on the capability (Aux Load): Generator Parameters All reactances and resistance values in on Machine MVA Base * Combined turbine-generator-exciter inertia, H: * Speed damping coefficient, D: Generator Saturation * Generator saturation at 1.0 p.u. voltage, S (1.0): * Generator saturation at 1.2 p.u. voltage, S (1.2):

Unsaturated Reactances * Direct axis synchronous reactance, Xd(i): * Direct axis transient reactance, X'd(i): * Direct axis sub-transient reactance, X"d(i): * Quadrature axis synchronous reactance, Xq(i): * Quadrature axis transient reactance, X'q(i): * Quadrature axis sub-transient reactance, X"q(i): * Stator leakage reactance, Xl: * Negative sequence reactance, X2(i): * Zero sequence reactance, X0(i): Saturated Reactances * Saturated subtransient reactance, X"d(v): * Negative sequence reactance, X2(v): * Zero sequence reactance, X0(v): Resistances * DC armature resistance, Ra: * Positive sequence resistance, R1: * Negative sequence resistance, R2: * Zero sequence resistance, R0: Time Constants * Direct axis transient open circuit, T'do: * Direct axis sub-transient open circuit, T"do: * Quadrature axis transient open circuit, T'qo: * Quadrature axis sub-transient open circuit, T"qo: * Armature three-phase short circuit, Ta3: Control Systems Select the appropriate dynamic model

* Exciter * If any of the above models are not submitted, then explanation is required: * Governor: * If any of the above models are not submitted, then explanation is required: * Power System Stabilizer (PSS): * If any of the above models are not submitted, then explanation is required: Additional Information: Synchronous Transformer * Want to submit data for a Generator Step-up Transformer (GSU)? Please complete all required information below. If you do not wish to submit a transformer for this turbine, please select "No" in the drop down above. Generator Step-Up (GSU) Transformer Form Note: Main Transformer information is requested in a separate form. * MVA base: Total Transformer Ratings (MVA) e.g. OA/FA1/FA2 * Rating 1:

* Rating 2: * Rating 3: * Select transformer windings: Impedances (All Values in on Transformer MVA base) * (a) High-side to low-side: * (b) High-side to tertiary: * (c) Low-side to tertiary: Winding Voltages (kv) * High-side: * Low-side: * Tertiary: Winding Connection Types (Delta, Wye, Wye Gnd, etc) * High-side: * Low-side: * Tertiary: * Tap position: Off-nominal Turns Ratio: Number of taps: Step size: Any additional comments on the transformer? Example: Specify machine ID

No Only fill the data below if 'Yes' is selected on the le MVA KV Summer Winter MW MVAR Underexcited MVAR MW MVAR Overexcited Please select... Load related to the operations of the plant (e.g. fans, pumps, etc.) Pink label a 'Location o dropdown kws/kva P.U. 1 < H < 10 0 D < 3 0 < S1.0

S1.0 < S1.2 xd < 2.5 x'd < 0.5 x xd x"d < x'd xq < xd x'q < xq x"q < x'q X"d(v) < X"d(i) Ohms sec sec sec sec sec 1. < T( do < 10.) 0.01667 < T"do < 0.2 0.2 T qo 1.5 0.01667 T"qo 0.2 0.025 Ta 0.1

Please select... Please select... Please select... Please select... Only fill the data below if 'Yes' is MVA MVA

MVA MVA Please select... R jx X/R If Three Windings was selected f with tertiary in the name are req KV KV KV

eft and additional comment box is only required if other than two options above' was selected for above

If Other or N/A is selected for Exciter textbox on the left will be required If Other or N/A is selected for Governer textbox on the left will be required If N/A is selected for PSS textbox on the left will be required s selected on the left

for transformer winding fields quired

Wind Farm Parameters * Required * Want to submit data for a Wind Farm? Please Select... Wind Farm Parameters * Specify manufacturer: * Specify model: * MW Value per turbine (nominal rating): * Number of wind turbines generators of the selected type: * MVA base: MVA * Terminal voltage: KV * Nominal power factor: on MVA base * Stator resistance, R1: Ohms * Saturated sub-transient reactance, X"d(v): on MVA base * Control mode: * Voltage relays? * If yes, provide voltage relay settings: * Frequency relays? * If yes, provide frequency relay settings: * Additional windfarm compensation: Wind Farm Transformer Generator Step-Up (GSU) Transformer Form Note: Main Transformer information is requested in a separate form. * MVA base: MVA

Total Transformer Ratings (MVA) e.g. OA/FA1/FA2 * Rating 1: MVA * Rating 2: MVA * Rating 3: MVA * Select transformer windings: Impedances (All Values in on Transformer MVA base) * (a) High-side to low-side: * (b) High-side to tertiary: * (c) Low-side to tertiary: Winding Voltages (kv) * High-side: KV * Low-side: KV * Tertiary: KV Winding Connection Types (Delta, Wye, Wye Gnd, etc) * High-side: * Low-side: * Tertiary: * Tap position: Off-nominal Turns Ratio: Number of taps: Step size: Any additional comments on the transformer?

No Only fill the data below if 'Yes' is selected on the le Please select... Please select... Please select... Please select...

Please select... R jx X/R If Three Windings was selected f with tertiary in the name are req

eft

for transformer winding fields quired

Inverter Based Parameters * Required * Want to submit data for an Inverted Based Generator? Please Select... Inverter Based Parameters * Type of inverter based technology (e.g solar, storage, etc.): * Specify manufacturer of inverter: * Specify model: * MW Value per inverter: MW * Total number of inverters: * MVA Base per inverter: MVA * Terminal voltage: KV * Nominal power factor: * Nominal output current at full load per inverter: Amps * Maximum fault current output from the inverter: Amps or per unit * How fast can the inverter be disconnected from the system subsequent to a cycles fault? Dynamic modeling * Description of dynamic performance of the inverter during a fault. Please describe how the selected inverter will behave dynamically with respect to real power, reactive power and tripping points for voltage and frequency: Examples: Constant real and reactive power injection during a fault. No tripping allowed. Fluctuations in real and reactive power depending on system conditions. Please submit dynamic model for an accurate representation. * Is the inverter designed with Low Voltage Ride-Through (LVRT) capability? * Voltage relays? * If yes, provide voltage relay settings: * Frequency relays? * If yes, provide frequency relay settings:

Note: All inverter based projects greater than 30 MW must submit a dynamic model. Dynamic model may be requested for projects less than 30 MW depending on the area. To avoid delays, whenever available, please submit a dynamic model. Inverter Based Transformer Generator Step-Up (GSU) Transformer Form Note: Main Transformer information is requested in a separate form. * MVA base: MVA Total Transformer Ratings (MVA) e.g. OA/FA1/FA2 * Rating 1: MVA * Rating 2: MVA * Rating 3: MVA * Select transformer windings: Impedances (All Values in on Transformer MVA base) * (a) High-side to low-side: * (b) High-side to tertiary: * (c) Low-side to tertiary: Winding Voltages (kv) * High-side: KV * Low-side: KV * Tertiary: KV Winding Connection Types (Delta, Wye, Wye Gnd, etc) * High-side: * Low-side: * Tertiary: * Tap position: Off-nominal Turns Ratio: Number of taps: Step size: Any additional comments on the transformer?

No Only fill the data below if 'Yes' is selected on the left Please select... Please select... Please select...

Please select... R jx X/R If Three Windings was selected for transfor with tertiary in the name are required

rmer winding fields

Main Transformer * Required * Want to submit data for a Main Transformer? Please Select... No Generator Step-Up (GSU) Transformer Form Note: Main Transformer information is requested in a separate form. * MVA base: MVA Total Transformer Ratings (MVA) e.g. OA/FA1/FA2 * Rating 1: MVA * Rating 2: MVA * Rating 3: MVA * Select transformer windings: Impedances (All Values in on Transformer MVA base) * (a) High-side to low-side: * (b) High-side to tertiary: * (c) Low-side to tertiary: Please select... R Winding Voltages (kv) * High-side: KV * Low-side: KV * Tertiary: KV Winding Connection Types (Delta, Wye, Wye Gnd, etc) * High-side: * Low-side: * Tertiary: * Tap position: Off-nominal Turns Ratio: Number of taps: Step size: Any additional comments on the transformer?

Only fill the data below if 'Yes' is selected on the left jx X/R If Three Windings was selected for transformer winding fields with tertiary in the name are required

Ownership S J W single ownership by respondent jointly owned with another entity wholly owned by an entity other than respondent Prime Mover Codes ST Steam Turbine, including nuclear, geothermal and solar steam (does not include Combined Cycle) GT Combustion (Gas) Turbine IC Internal Combustion (diesel, piston) Engine CA Combined Cycle Steam Part CC Combined Cycle Total Unit (use only for plants/generators that are in planning stage, for which specific generator details cannot be provided) CS Combined Cycle Single Shaft (combustion turbine and steam turbine share a single generator) CT Combined Cycle Combustion Turbine Part (type of coal must be reported as energy source for integrated coal) HY Hydraulic Turbine (includes turbines associated with delivery of water by pipeline) PS Hydraulic Turbine Reversible (pumped storage) PV Photovoltaic WT Wind Turbine CE Compressed Air Energy Storage FC Fuel Cell OT Other NA Unknown at this time (use only for plants/generators that are in planning stage, for which specific generator details cannot be provided) Energy Source Code BIT Anthracite Coal, Bituminous Coal LIG Lignite Coal SUB Subbituminous Coal WC Waste/Other Coal (Anthracite Culm, Bituminous Gob, Fine Coal, Lignite Waste, Waste Coal) SC Coal-based Synfuel and include briquettes, pellets, or extrusions, which are formed by binding materials and processes that recycle material DFO Distillate Fuel Oil (includes all Diesel and No. 1, No. 2, and No. 4 Fuel Oils) JF Jet Fuel KER Kerosene RFO Residual Fuel Oil (includes No. 5 and No. 6 Fuel Oils and Bunker C Fuel Oil)

WO PC NG BFG OG PG NUC AB BLQ GEO LFG MSW OBS OBL OBG OTH R SLW SUN TDF WAT WDS WDL WND NA Oil-Other and Waste Oil (Butane (Liquid), Crude Oil, Liquid Byproducts, Oil Waste, Propane (Liquid), Re-Refined Motor Oil, Sludge Oil, Tar Oil) Petroleum Coke Natural Gas Blast-Furnace Gas Other Gas (Butane, Coal Processes, Coke-Oven, Refinery, and other processes) Propane Nuclear (Uranium, Plutonium, Thorium) Agriculture Crop Byproducts/Straw/Energy Crops Black Liquor Geothermal Landfill Gas Municipal Solid Waste Other Biomass Solids (Animal Manure and Waste, Solid Byproducts, and other solid biomass not specified) Other Biomass Liquids (Ethanol, Fish Oil, Liquid Acetonitrile Waste, Medical Waste, Tall Oil, Waste Alcohol, and other biomass liquids not specified) Other Biomass Gases (Digester Gas, Methane, and other biomass gases) Other (Batteries, Chemicals, Coke Breeze, Hydrogen, Pitch, Sulfur, Tar Coal, and miscellaneous technologies) Purchased Steam Sludge Waste Solar (Photovoltaic, Thermal) Tires Water (Conventional, Pumped Storage) Wood/Wood Waste Solids (Paper Pellets, Railroad Ties, Utility Poles, Wood Chips, and other wood solids) Wood Waste Liquids (Red Liquor, Sludge Wood, Spent Sulfite Liquor, and other wood related liquids not specified) Wind Not Available