DIP -pin, High-Current and Low-ON-resistance Type DIP The highest class load current of realized with DIP package Contact form: a (SPST-NO) Load voltage: V, V, V, V, or V GVM-@CR@/@FR@ -V Relay: Continuous load current of 5 A ( A) max. * -V Relay: Continuous load current of A ( A) max. * -V Relay: Continuous load current of.5 A ( A) max. * -V Relay: Continuous load current of. A (. A) max. * -V Relay: Continuous load current of. A (. A) max. * * Values in parentheses are for connection C. Note: The actual product is marked differently from the image shown here. RoHS Compliant Application Examples Communication equipment Industrial equipment Test & Measurement equipment Power circuit Security equipment Package (Unit : mm, Average) Model Number Legend DIP -pin PCB Terminals GVM-@ @ @ @ @ 5 9..5. Load Voltage : V. Contact form : a (SPST-NO). Package C : DIP -pin with PCB : V F : DIP -pin with surface-mounting. : V : V Surface-mounting Terminals : V 9..5. Additional functions R: Low ON resistance 5. Other informations When specifications overlap, serial code is added in the recorded order.. Note: The actual product is marked differently from the image shown here. Ordering Information Package DIP Contact form a (SPST-NO) Stick packaging Tape packaging Load voltage Continuous load current Model (peak value) Minimum Model Minimum (peak value) * * Surface-mounting package Surface-mounting package PCB Terminals Terminals quantity Terminals quantity V 5 A GVM-CR GVM-FR GVM-FR(TR5) V A GVM-CR GVM-FR GVM-FR(TR5) V.5 A GVM-CR GVM-FR 5 pcs. GVM-FR(TR5) 5 pcs. V. A GVM-CR GVM-FR GVM-FR(TR5) V. A GVM-CR GVM-FR GVM-FR(TR5) * The AC peak and DC value are given for the load voltage and continuous load current. Note: To order tape packaging for Relays with surface-mounting, add (TR5) to the end of the model number.
Absolute Maximum Ratings (Ta = 5 C) Input Output Item Symbol GVM-CR GVM-FR GVM-CR GVM-FR GVM-CR GVM-FR GVM-CR GVM-FR GVM-CR GVM-FR LED forward current IF ma Note:. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. Unit Measurement conditions Repetitive peak LED forward current IFP A μs pulses, pps LED forward current reduction rate ΔIF/ C -. ma/ C Ta 5 C LED reverse voltage VR 5 V temperature TJ 5 C Load voltage (AC peak/dc) VOFF V A 5.5.. A: Continuous load B IO 5.5.. A AC peak/dc current.. B and C: DC A -5 - -5 - - ON current B ΔIO/ C -5 - -5 - - reduction rate - - - - - ma/ C Ta 5 C Pulse ON current lop 5 9.5.. A t= ms, Duty=/ temperature TJ 5 C Dielectric strength between I/O (See note.) VI-O,5 Vrms AC for min Ambient operating temperature Ta - to +5 - to + - to +5 C With no icing or Ambient storage temperature Tstg -55 to +5 C condensation Soldering temperature C s Diagram DIP GVM-@CR@/@FR@ A 7 5 LOAD AC or DC LOAD B 7 DC 5 LOAD 7 DC 5
Electrical Characteristics (Ta = 5 C) DIP GVM-@CR@/@FR@ Input Output Item Symbol GVM-CR GVM-CR GVM-CR GVM-CR GVM-CR GVM-FR GVM-FR GVM-FR GVM-FR GVM-FR Unit Measurement conditions Minimum.5 LED forward voltage VF Typical. V IF= ma Maximum. Reverse current IR Maximum μa VR=5 V Capacitance between CT Typical 7 pf V=, f=mhz Trigger LED forward current Release LED forward current Maximum resistance with output ON A B C Current leakage when the relay is open Capacitance between Capacitance between I/O Insulation resistance between I/O IFT IFC RON ILEAK Typical..... Maximum 5 5 5 5 Minimum. Typical.9 -.9.7 Typical...5. Maximum.5.5.5 5 Maximum.5.75.5.5 Maximum..75.5..5 Typical.....5 Maximum COFF Typical 5 7, pf V=, f= MHz ma ma Ω μa GVM-CR/FR : IO= A GVM-CR/FR : IO= A GVM-CR/FR : IO= A GVM-CR/FR : IO=. A GVM-CR/FR : IO=. A GVM-CR/FR : IOFF= μa GVM-CR/FR : IOFF= μa GVM-CR/FR : IOFF= μa GVM-CR/FR : IOFF= μa GVM-CR/FR : IOFF= μa GVM-CR/FR : IO= A, IF=5 ma, t< s GVM-CR/FR : IO= A, IF=5 ma, t < s GVM-CR/FR : IO= A, IF=5 ma, t < s GVM-CR/FR : IO=. A, IF= ma, t < s GVM-CR/FR : IO=. A, IF=5 ma, t < s GVM-CR/FR : IO= A, IF= ma, t < s GVM-CR/FR : IO= A, IF=5 ma, t < s GVM-CR/FR : IO= A, IF=5 ma, t < s GVM-CR/FR : IO=. A, IF= ma, t < s GVM-CR/FR : IO=. A, IF= ma, t < s GVM-CR/FR : IO= A, IF= ma, t < s GVM-CR/FR : IO= A, IF=5 ma, t < s GVM-CR/FR : IO= A, IF=5 ma, t < s GVM-CR/FR : IO=. A, IF= ma, t < s GVM-CR/FR : IO=. A, IF= ma, t < s VOFF=Load Voltage Ratings CI-O Typical. pf f= MHz, VS= V RI-O Minimum, Typical Turn-ON time Typical.5.5.5.. Maximum 5 Turn-OFF time Typical...7 Maximum Note:. Turn-ON and Turn-OFF Times IF 5 RL VDD VOUT IF VOUT t ON % 9% t OFF MΩ ms VI-O=5 VDC, ROH=% IF =5 ma, RL = Ω, VDD= V (See note.) Recommended Operating Conditions For usage with high reliability, Recommended Operation Conditions is a measure that takes into account the derating of Absolute Maximum Ratings and Electrical Characteristics. Each item on this list is an independent condition, so it is not simultaneously satisfy several conditions. Item Symbol Spacing and Insulation GVM-CR GVM-FR GVM-CR GVM-FR GVM-CR GVM-FR GVM-CR GVM-FR GVM-CR GVM-FR Load voltage (AC peak/dc) VDD Maximum V Typical 5 5 5 5 Operating LED forward current IF ma Maximum 5 Continuous load current (AC peak/dc) IO Maximum 5.5.. A Minimum - Ambient operating temperature Ta C Maximum 5 Item Minimum Unit Creepage distances 7. Clearance distances 7. mm Internal isolation thickness. Unit
Engineering Data LED forward current vs. LED forward current IF (ma) 5 5 5 5 I F - Ta (Maximum value) - - LED forward current vs. LED forward voltage LED forward current IF (ma). Ta=5 C I F - V F Continuous load current vs. GVM-CR/FR GVM-CR/FR/CR/FR GVM-CR/FR: I O - T a (Maximum value) GVM-CR/FR: A, B GVM-CR/FR: A, B GVM-CR/FR: GVM-CR/ FR: A, B - Continuous load current vs. On-state voltage GVM-CR/FR GVM-CR/FR/CR/FR I O - V ON - - Ta=5 C, IF=5mA, t<s, A GVM-CR/ FR GVM-CR/ FR GVM-CR/ FR GVM-CR/FR/CR/FR...... GVM-CR/FR: GVM-CR/FR: A, B GVM-CR/FR: GVM-CR/FR: A, B I O - T a (Maximum value) - GVM-CR/FR/CR/FR.... -. -. -. Ta=5 C, IF=5mA, t<s, A GVM-CR/FR I O - V ON GVM-CR/FR DIP GVM-@CR@/@FR@....... LED forward voltage VF (V) On-state resistance vs. GVM-CR/FR GVM-CR/FR/CR/FR R ON - Ta On-state resistance RON (Ω).5..5..5..5..5 IO=A, IF=5mA, t<s, A GVM-CR/FR GVM-CR/FR GVM-CR/FR - - - -.5 -.5.5.5 On-state voltage VON (V) GVM-CR/FR/CR/FR On-state resistance RON (Ω) 5 GVM-CR/FR R ON - Ta GVM-CR/FR : IO=.A, IF=mA, t<s, A GVM-CR/FR : IO=.A, IF=5mA, t<s, A GVM-CR/FR - - -. -.5 - -.5.5.5 On-state voltage VON (V) Trigger LED forward current vs. Trigger LED forward current IFT (ma)..7..5... GVM-CR/FR: IO=.A GVM-CR/FR: IO=.A Other: IO=A GVM-CR/FR GVM-CR/FR GVM-CR/FR I FT - Ta. GVM-CR/FR GVM-CR/FR - -
DIP GVM-@CR@/@FR@ GVM-@CR@/@FR@ Engineering Data Turn ON, Turn OFF time vs. LED forward current GVM-CR/FR GVM-CR/FR/CR/FR GVM-CR/FR/CR/FR t ON, t OFF - I F t ON, t OFF - I F Turn ON, Turn OFF time (ms). GVM-CR/FR Ta=5 C VDD=V RL=W GVM-CR/FR GVM-CR/FR. LED forward current (ma) Turn ON, Turn OFF time vs. GVM-CR/FR GVM-CR/FR/CR/FR t ON, t OFF - T a Turn ON, Turn OFF time, (ms). VDD=V, RL=Ω, IF=5mA GVM-CR/FR GVM-CR/FR GVM-CR/FR. - - Turn ON, Turn OFF time (ms). GVM-CR /FR GVM-CR/FR GVM-CR/FR Ta=5 C VDD=V RL=Ω. LED forward current (ma) GVM-CR/FR/CR/FR Turn ON, Turn OFF time, (ms). t ON, t OFF - T a VDD=V, RL=Ω, IF=5mA GVM-CR/FR GVM-CR/FR GVM-CR/FR. - - Current leakage vs. Current Leakage ILEAK (μa) I LEAK - T a GVM-CR/FR: VOFF= V GVM-CR/FR: VOFF= V GVM-CR/FR: VOFF= V GVM-CR/FR: VOFF= V GVM-CR/FR: VOFF= V GVM-CR/FR GVM-CR/FR.. GVM-CR/FR. GVM-CR/FR GVM-CR/FR. - - 5
Appearance / Terminal Arrangement / Internal s Appearance DIP (Dual Inline Package) DIP -pin Dimensions (Unit: mm) DIP -pin OMRON logo Pin mark CR 9 Mold pin mark (See note.) Model name (See note.) LOT.NO. Note:. The actual product is marked differently from the image shown here. Note:. GVM does not appear in the model number on the Relay. Note:. The indentation in the corner diagonally opposite from the pin mark is from a pin on the mold. PCB Terminals Weight:.5 g Terminal Arrangement/Internal s (Top View) Surface-mounting Terminals Weight:.5 g PCB Dimensions (BOTTOM VIEW).5.5 Eight,.-dia. holes (.) DIP GVM-@CR@/@FR@ 9.±.5 9.±.5.5 +.5 -.5.±.5.±.5.5 min..±.5.5±..5±.5 7.±.5 7.5 to..5 +. -.5.±.5 Note: The actual product is marked differently from the image shown here. 7.±.5.5 +.5 -.5. +.5 -.. min..±.5. min.. max..5±.5 (.) (.5) (.5) Actual Mounting Pad Dimensions (Recommended Value, Top View).5. to...5 Approved Standards UL recognized Model Approved Standards Contact form File No. GVM-CR GVM-FR GVM-CR GVM-FR GVM-CR GVM-FR GVM-CR GVM-FR GVM-CR GVM-FR UL (recognized) a (SPST-NO) E555 Safety Precautions Refer to the Common Precautions for All for precautions that apply to all. Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. K5-E- 7()(O)