OPERATOR S INSTRUCTION MANUAL

Similar documents
ET-3888 True RMS Clamp Meter. User Manual

Multifunction Digital

CONTENTS MS2033A. 1.Introduction Safety Information...01

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

NOTE: Fully read and understand this manual before using this Digital Multimeter.

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

AC/DC CLAMP METER USER S MANUAL

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

MS2030 CAT III 600 V A V AUTO RS232

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

Digital Multimeter, Pen Type

AMM-1022 Digital Multimeter USER`S MANUAL

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

Digital Clamp Meter Model: &

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

OPERATOR S INSTRUCTION MANUAL

Pen-type DIGITAL MULTITESTER

MT /6 Smart Digital Clamp Meter. User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd.

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

DVM1190 DIGITAL MULTIMETER

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

MS8223A. CAT.IIi 600 V

Digital Clamp Meter. User Manual

MODEL: D03128 CLAMP METER

Model: &

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

Model DIGITAL MULTIMETER

User Manual Digital Clamp Multimeter. model no.: MSR-C600

DCM730. Digital Clamp Meter User s Manual

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

INSTRUCTION MANUAL DIGITAL MULTIMETER

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

User Guide. Digital AC/DC Clamp Meter Model 38394

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

User s Guide. Digital AC/DC Clamp Meter Model 38394

770E DIGITAL MULTIMETER OPERATOR S MANUAL

AC Clamp Meter + Phase Rotation Tester

Mini Clamp Meter Model:

MS2109A AC/DC Clamp Meter. User Manual. Contents

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

ACA LEAKAGE TESTER OPERATION MANUAL. auto range, true rms. Model : DL-9954

ProfiScale MULTI Multimeter

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

UT207A/208A/209A Operating Manual. Table of Contents

Sales: Technical: Fax:

INSTRUCTION MANUAL UTL260

Digital Clamp Meter (TRMS) Model : 2727

DIGITAL MULTIMETER AUTORANGING

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

ATK Clamp Meter

DIGITAL MULTIMETER INSTRUCTION MANUAL

2,000 counts, 200 Amp ACA/DCA, 600 V ACV/DCV, True RMS, OHMS, Continuity, Hold, Peak Hold FORK CURRENT TESTER. Model : FT-9950

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

User s Guide. 400A AC/DC Clamp Meter. Model MA220

AUTO-SCAN Pen R/C/D Meter for SMD AX-507B USER S MANUAL

Digital Multimeter with Backlight

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

DMM8900 SERIES USERS MANUAL

BENNING. CM7 Electrical Tester. Service Information

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.

AX-C Introduction. 2. Safety Information

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

AC/DC True RMS Power Clamp Meter ELECTRONIC TEST INSTRUMENTS MODEL 325

DIGIT & POINTER MULTIMETER

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

1.General instructions Specifications Description...7

Item ref: UK MTM01 DIGITAL MULTITESTER. User Manual

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

DIGITAL CLAMP METER Use s Manual

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

3B SCIENTIFIC PHYSICS

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

User s Guide. Model MA A AC Mini Clamp-on Meter

User Manual Digital Multimeter. model no.: MSR-U1000

VC835 DIGTAL MULTIMETER Operation Manual

DIGITAL CLAMPMETER MODEL

Pince Multimètre - Courants de fuites Leakage Clamp-on Meter Multimeter und Fehlerstrom-Messzange Pinza Multimetro - Correnti di fuga

True RMS Digital Multimeter Model:

312, 316, 318. Clamp Meter. Users Manual

Dawson DDM190. Digital Multimeter User s Manual

MS8216 DIGITAL MULTIMETER OPERATOR S MANUAL

User Manual. All rights reserved. Specifications are subject to change without notice.

Transcription:

2 OPERATOR S INSTRUCTION MANUAL CLAMP METER HOLD 20 A 200 A 2 A 600 600 LIGHT ON/OFF Digital Clamp Meter 2 20 200 A khz COM CAT.II MAX 600

CONTENTS 1. General instruction.....1 2. Description...1 2.1 Precautions for us...1 2.2 Safety symbols...2 2.3 Maintenance...2 3. Each component name description...3 3.1 Meter panel...3 3.2 LCD display...5 3.3 Functional keys...6 3.4 Transformer jaws...6 3.5 Input socket...6 4. Technical index......7 4.1 General index...7 4.2 Accuracy index...8 CONTENTS 5. Operating Instructions...10 5.1 AC Current (ACA) measurement...10 5.2 DC oltage (DC) measurement...12 5.3 AC Current (AC) measurement...13 5.4 Resistance ( Ω ) measurement......14 5.5 Audible continuity test....15 6. Meter Maintenance...16 6.1 Maintenance...16 6.2 Battery replacement...16

1. General instructions This digital clamp meter has been designed according to International Electro Safety Standard IEC-61010 concerning safety requirements for electronic measuring instruments and hand-held current clamps; meeting the requirements for 600CAT.II of IEC-61010 and grade 2 for pollution. Before using this meter, please read carefully this user's manual and respect the related safety precautions. 2. General instructions 2.1 Precautions for use Before measurement, warm up for at least 30 seconds. Don t use the meter or lead if they look damaged. To meet the safety requirements, only use the test leads supplied with the meter. If the test lead should be replaced, a new one with the same model or same electric specification should be adopted. If the meter is placed in a relatively noisy environment, meter readings will become unstable, even with big errors. Before changing the measuring range, you must ensure that the test lead is not connected to any circuit to be tested. When you can t determine the size range of signal to be tested, please switch the measuring range to the maximum position. When you use the meter to measure, you should make the test lead and the rotary switch in the correct position. When use the test lead to measure, you should keep the fingers behind the protection ring. When the voltage to be tested exceeds 60DC or 30AC RMS, please operate carefully to prevent electric shock. Do not exceed the input limit specified in each measuring range to prevent the meter to be damaged. When measuring current, the test lead can not be inserted into the input socket. When you hold the clamp meter to measure, you should keep the fingers behind protection ring of meter body. Before on-line resistance measurement, you should turn off the power for all circuits and discharge all capacitors. Change the battery as early as possible when the symbol appears to avoid incorrect reading. 2.2 Safety symbols Symbols used on the meter and in this manual: Important cautions, refer to the instruction manual. Earth Double insulation (safety equipment with category II) 2.3 Maintenance Maintenance and calibration should be done by professionals. To prevent contamination or electrostatic damage inside the meter, before opening the meter case, appropriate protective measures should be taken. If you notice any abnormality, the meter should be turned off and sent for repair immediately. 01 02

2 If the casing is not covered properly, screws are not tightened, do not put it to use. When it is not in use for a long time, please remove the battery and avoid storing it in the place with high temperature and humidity. 3. Each component name description 3.1 Meter panel (1) Transformer jaws (2) Protection ring (3) Jaw opening trigger (4) LIGHT key (5) LCD display (6) COM input socket (7) Ω input socket (8) ON/OFF key (9) Rotary switch (10) HOLD key CLAMP METER 20 A 2 A 600 HOLD 200 A 9 600 LIGHT ON/OFF 8 Digital Clamp Meter 2 20 200 A khz COM 7 CAT.II MAX 600 03 04

3.2LCD display H A DC AC DC AC 2 20 200 Low battery indication Hold data indication Continuity function indication oltage measurement indication Current measurement indication Ohm measurement indication DC input indication AC input indication A Negative polarity indication 3.3 Functional keys HOLD key: Press this key; LCD display will keep the test value. Press this key again, the meter will return to normal mode. ON/OFF key: This key is used to turn the meter on or off. LIGHT key: Holding this key for 3 seconds to turn the backlight on, press it again, the backlight is auto-off. 3.4 Transformer jaws Pick up live conductor to induce AC current signals. 3.5 Input socket Ω input socket: Positive terminal of voltage, resistance measurement and audible continuity test (connected with red lead). COM input socket: Negative terminal of voltage, resistance measurement and audible continuity test (connected with black lead). 05 06

4. Technical index 4.1 General index Environmental conditions for using: Temperature and relative humidity of working environment: 0~40 C (<80%RH). Temperature and relative humidity of storage environment: -10~60 C (<70%RH, removing battery). Maximum voltage between any input socket and earth: 600rms. Principle of measurement: double integral A/D conversion. Sampling rate: about 2 times/second. Display: 3 1/2 digits LCD display with max. reading 1999. Automatically indicate unit and symbol according to function level. Measuring range switch method: manually Over measuring range indication: OL will display on LCD. When the input measuring voltage exceeds 2000, OL will display on the LCD (AC and DC). Input polarity indication: symbol will display automatically. Low battery indication: When the low battery is lower than the normal operating voltage, will display on the LCD. Battery: DC 1.5 X 2 SIZE AAA Max. opening dimension of transformer jaws: φ28mm. Max. dimension of conductor: φ28mm. Dimension: 194(L) 72(W) 35(H)mm. Weight: about 200g (with battery). Accessories: Instruction Manual, leads, package bag and package box. 4.2Accuracy index Accuracy: ±( % reading + the number of characters), gurantee for one year. Base condition: ambient temperature is from 18 C to 28 C, relative humidity is not greater than 80% When making AC current measurement, please position the conductor to the center If the conductor is not positioned at the center, the max. additional error resulted is 1.5%. MARK MARK CONDUCTOR MARK 07 08

4.2.1 AC Current range 2A 20A 200A Resolution 0.001A 0.01A 0.1A - Frequency range: 50/60Hz 4.2.2 DC oltage Range 200 600 Resolution 0.1 1 4.2.3 AC Current Accuracy ±(2% of rdg + 20 characters) Accuracy ±(1% of rdg + 5 characters) - Input impedance: 10MΩ -Maximum input voltage: 600 DC or 600 AC RMS. Range 200 600 Resolution 0.1 1 Accuracy ±(1.5% of rdg + 5 characters) - Input impedance: 10M - Frequency response: 40~400Hz - Maximum input voltage: 600 DC or 600 AC RMS. 4.2.4 Resistance Range Resolution Accuracy 200Ω 1Ω ±(1% of rdg + 5 characters) - Open-circuit voltage: Less than 700m - Overload protection: 250 DC or 250 AC RMS. 4.2.5 Audible continuity Range Resolution Inbuilt buzzer will alarm when the resistance is lower than 70Ω - Open-circuit voltage: below 700m - Overload protection: 250 DC or 250 AC RMS. 5. Operating Instructions 5.1 AC Current (ACA) measurement Please make sure that all test leads are removed from the input socket. The current of the conductor with high voltage (>600) is not allowed for measurement to prevent electrical shock. Turn the rotary switch to position A in the desired range. Pull the trigger, clamp the wire to be measured (one line) in the center of transformer jaws (shown as below figure) and make transformer jaws fully closed. The measurement current value can be read through the LCD display. If only OL shows on the display, it means overload, and a higher measuring range should be selected immediately. 09 10

CORRECT 5.2DC oltage (DC) measurement Maximum input voltage of DC voltage (DC) is 600DC. DC voltage higher than 600dc is not allowed for measurement to prevent electrical shock and / or damage the meter. Turn the rotary switch to 600. Connect black test lead and red test lead to COM input socket and input socket separately. Use the other two ends of test leads to measure the voltage of circuit to be measured. (Connect with the circuit to be measured in parallel) The measurement current value can be read through the LCD display. INCORRECT 11 12

5.3 AC oltage (AC) measurement Maximum input voltage of AC current (AC) is 600rms. AC voltage higher than 600rms is not allowed for measurement to prevent electrical shock and / or damage the meter. urn the rotary switch to 600~. Connect black test lead and red test lead to COM input socket and input socket separately. Use the other two ends of test leads to measure the voltage of circuit to be measured. (Connect with the circuit to be measured in parallel) The measurement voltage value can be read through the LCD display. 5.4 Resistance ( Ω) measurement Before making online resistance measurement, make certain that all test circuits are disconnected and discharge all capacitors. Turn the rotary switch to Ω Connect black test lead and red test lead to COM input socket and input socket separately. Use the other two ends of test leads to measure the resistance of circuit to be measured. The measurement voltage value can be read through the LCD display. 13 14

5.5Audible continuity test Before making online resistance measurement, make certain that all test circuits are disconnected and discharge all capacitors. Turn the rotary switch to Ω Connect black test lead and red test lead to COM input socket and input socket separately. Use the other two ends of test leads to make continuity test. When making continuity test, if the resistance of circuit to be measured is less than 70 Ω, buzzer will alarm continuously. 6. Meter Maintenance 6.1 Maintenance Before opening the back cover, you should power off and make sure that the test lead is disconnected from the measurement circuit to avoid electric shock. Use a piece of damp cloth and a small amount of detergent to clean the meter regularly, do not use chemical solvent to clean the meter. 6.2 Battery Replacement Before opening the battery cover, power off and make certain that all test leads are disconnected from the testing circuits to avoid electric shock. Follow these steps to replace the battery: When the battery voltage is lower than the normal operating voltage, low battery symbol will display on the LCD display. At this moment, the battery should be replaced. Press the power switch to cut off the meter power supply. Unscrew the screws on the battery cover, remove the old battery and replace it with a new AAA 1.5 battery. Install the bottom shell back and tighten the screws. Continuity (audible) No continuity 15 16

17 HYS006455