Creating Calibrated UWB WiMedia Signals

Similar documents
Automated Frequency Response Measurement with AFG31000, MDO3000 and TekBench Instrument Control Software APPLICATION NOTE

Power Measurement and Analysis Software

Measuring Power Supply Switching Loss with an Oscilloscope

io n Data Sheet or The P5205 is a 100 MHz Active Differential Probe capable of measuring fast rise times of signals in floating circuits. This 1,300 V

10 GHz Linear Amplifier PSPL5866 Datasheet

High-voltage Differential Probes

Passive Voltage Probes

Stress Calibration for Jitter >1UI A Practical Method

12.5 Gb/s PatternPro Programmable Pattern Generator PPG1251 Series Datasheet

Verifying Power Supply Sequencing with an 8-Channel Oscilloscope APPLICATION NOTE

Basics of Using the NetTek YBA250

46 GBaud Multi-Format Optical Transmitter OM5110 Datasheet

Visual Triggering. Technical Brief

Programmable Pulse Generators PSPL10050A, PSPL10060A, PSPL10070A Datasheet

Choosing an Oscilloscope for Coherent Optical Modulation Analysis

Characterize Phase-Locked Loop Systems Using Real Time Oscilloscopes

12.5 Gb/s Driver Amplifier LABware Module PSPL8001 Datasheet

AC Current Probes CT1 CT2 CT6 Data Sheet

PatternPro Error Detector PED3200 and PED4000 Series Datasheet

Be Sure to Capture the Complete Picture

30 A AC/DC Current Probe TCP0030A Datasheet

Soldering a P7500 to a Nexus DDR Component Interposer

Sophisticated Power Loss Analysis Using A Digital Phosphor Oscilloscope

TekConnect Adapters TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM TCA292D Datasheet

Power Analysis Application Module DPO4PWR MDO3PWR Datasheet

Programmable Pulse/Pattern Generator PSPL1P601 and PSPL1P602 Datasheet

12.5 Gb/s PatternPro Programmable Pattern Generator PPG1251 Series Datasheet

12.5 Gb/s Driver Amplifier PSPL5865 Datasheet

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

Measurement Statistics, Histograms and Trend Plot Analysis Modes

Time and Frequency Measurements for Oscillator Manufacturers

20X Low Capacitance Probe P6158 Datasheet

High-impedance Buffer Amplifier System

Ethernet Transmitter Test Application Software TekExpress 10GBASE-T and NBASE-T Datasheet

AC/DC Current Probe TCP0150 Datasheet

Differential Probes P6248 P6247 P6246 Datasheet

Understanding AWG70000A Series Frequency Response and DAC Performance

Low Capacitance Probes Minimize Impact on Circuit Operation

Measuring Wireless Power Charging Systems for Portable Electronics

30 Gb/s and 32 Gb/s Programmable Pattern Generator PPG Series Datasheet

100GBASE-KR4/CR4 & CAUI-4 Compliance and Characterization Solution

Performing Safe Operating Area Analysis on MOSFETs and Other Switching Devices with an Oscilloscope APPLICATION NOTE

Don t Let EMI/EMC Compliance Certification Slow You Down TUTORIAL

Measuring Vgs on Wide Bandgap Semiconductors APPLICATION NOTE

Advanced Statistical Analysis Using Waveform Database Acquisition

LE160 LE320 Linear Equalizer Datasheet Tektronix Linear Equalizer

Testing with Versatile Pulse Generation Solutions

Simplifying DC-DC Converter Characterization using a 2600B System SourceMeter SMU Instrument and MSO/DPO5000 or DPO7000 Series Scope APPLICATION NOTE

Debugging SENT Automotive Buses with an Oscilloscope APPLICATION NOTE

16 Gb/s, 30 Gb/s, and 32 Gb/s PatternPro Pattern Generator PPG1600, PPG3000, and PPG3200 Series Datasheet Key features

Passive High Voltage Probes P5100A-TPP0850-P5122-P5150-P6015A Datasheet

Trouble-shooting Radio Links in Unlicensed Frequency Bands TUTORIAL

P7600 Series TriMode Probes

Tektronix Logic Analyzer Probes P6800/P6900 Series Datasheet

Evaluating and Optimizing Radio Frequency Identification (RFID) Systems Using Real-Time Spectrum Analysis

Fundamentals of AC Power Measurements

Replicating Real World Signals with an Arbitrary/Function Generator

1.5 GHz Active Probe TAP1500 Datasheet

TriMode Probe Family P7700 Series TriMode Probes

If I Could... Imagine Perfect Vision

16 Gb/s, 30 Gb/s Gb/s, and 32 Gb/s Programmable PatternPro Pattern Generator PPG PPG1600, PPG3000, and PPG3200 Series Datasheet Key features

Isolation Addresses Common Sources of Differential Measurement Error

16 Gb/s, 30 Gb/s, and 32 Gb/s PatternPro Pattern Generator PPG1600, PPG3000, and PPG3200 Series Datasheet Notice to EU customers

Simplifying FET Testing with 2600B System SourceMeter SMU Instruments APPLICATION NOTE

P7500 Series Probes Tip Selection, Rework and Soldering Guide

Advanced Test Equipment Rentals ATEC (2832)

Passive High Voltage Probes P5100 P5102 P5120 P6015A

DPO7OE1 33 GHz Optical Probe

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

Using the Model 4225-RPM Remote Amplifier/ Switch to Automate Switching Between DC I-V, C-V, and Pulsed I-V Measurements APPLICATION NOTE

100GBASE-KR4, 100GBASE-CR4, & CAUI-4 Compliance and Characterization Solution for Real Time Scopes

Tire Pressure Monitoring Systems and Remote/Passive Keyless Entry

KickStart Instrument Control Software Datasheet

SOURCE MEASURE UNITS. Make Multiple Measurements Accurately Using a Single Instrument All While Saving Space, Time and Money

Programmable DC Electronic Loads. Series Programmable DC Electronic Loads. Programmable DC electronic loads DC POWER SUPPLIES

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

TriMode Probe Family. P7500 Series Data Sheet. Features & Benefits. Applications

Overcoming RF Signal Generation Challenges with New DAC Technologies WHITE PAPER

Arbitrary Function Generator AFG1022 Datasheet

Active Power Factor Correction Verification Measurements with an Oscilloscope APPLICATION NOTE

10GBASE-KR/KR4 Compliance and Debug Solution

TriMode Probe Family. P7500 Series Datasheet. Features & Benefits. Applications

Z-Active Differential Probe Family P7313 P7380A P7360A P7340A Datasheet

Arbitrary/Function Generator AFG1000 Series Datasheet

Arbitrary Function Generator AFG1000 Series Datasheet

Performing Cyclic Voltammetry Measurements Using Model 2450-EC or 2460-EC Electrochemistry Lab System

Low Cost RF Sensors. application note

Understanding Oscilloscope Bandwidth, Rise Time and Signal Fidelity

Tools to Boost Oscilloscope Measurement Resolution to More than 11 Bits APPLICATION NOTE

e-guide to RF Signals UNLICENSED & ISM BANDS LAND MOBILE & PUBLIC SAFETY CELLULAR AERONAUTICAL RADIO & TELEVISION BROADCAST WEATHER RADAR

OM2210 Coherent Receiver Calibration Source OM2210 Datasheet

S540 Power Semiconductor Test System Datasheet

50MHz arbitrary waveform/function generator

Using the Ramp Rate Method for Making Quasistatic C-V Measurements with the 4200A-SCS Parameter Analyzer APPLICATION NOTE

Agilent Spectrum Visualizer (ASV) Software. Data Sheet

In-circuit Measurements of Inductors and Transformers in Switch Mode Power Supplies APPLICATION NOTE

PA1000 Single Phase AC/DC Power Analyzer Datasheet

Wave Inspector Navigation and Search: Simplifying Waveform Analysis. Introduction. Application Note

RF and Microwave Power Sensors/Meters Tektronix PSM3000, PSM4000, and PSM5000 Series Data Sheet

AC/DC Current Measurement Systems

Transcription:

Creating Calibrated UWB WiMedia Signals Application Note This application note details the procedure required for signal path calibration when applied to Ultra-Wideband (UWB) signal generation using the following methods: Direct RF signal generation IF signal generation using an upconverter In this application note, solutions such as the AWG Series arbitrary waveform generators with RFXpress software tools will be described.

Application Note Why Calibration? To provide high data rates, the FCC in 2002 approved the unlicensed use of UWB devices in the spectrum of 3.1 GHz to 10.6 GHz for short range communication. The term UWB is used when the bandwidth of the signal is greater than 20% of the carrier frequency. That is: Or Total Bandwidth > 500 MHz 20% The WiMedia specification divides the UWB frequency spectrum into six Band Groups with five Band Groups (1 to 4 and the 6th) consisting of three bands each and the fifth Band Group consisting of two bands. Each of the bands within a Band Group has a bandwidth of 528 MHz. The WiMedia specification defines several Time-Frequency Coding (TFC) sequences where signals are frequency hopped between the bands within Band Group, thus having a bandwidth between 528 MHz to 1.584 GHz. Using Tektronix RFXpress software, there are three ways to generate the WiMedia signals: Direct RF: Using an arbitrary waveform generator, the AWG7122B with optional Interleave operation with up to a 24 GS/s sample rate, Band Group 1 to Band Group 6 1 can be directly generated at RF with ease. Using upconverters: An IF signal can be generated using an AWG and using an external mixer to up convert to the required RF frequency. Using external IQ modulators: An external modulator can be used to modulate the signals, with the AWG generating the hopped I and Q baseband signals, thus reducing the necessity of an external hopping synthesizer and complex switching. 1 Using a Tektronix AWG7122B with option 6, BG5 requires calibration. Figure 1. Tektronix RFXpress software for generating WiMedia signals. To create a proper test signal, it is necessary that the signal spectrum within the band of interest has flat amplitude and a linear phase response. The whole test setup (consisting of an AWG, an upconverter or an IQ modulator) used to generate the WiMedia UWB signals may not have a flat response in the wide frequency band defined in the WiMedia specifications. Also due to the path loss and the cables, the band edges might degrade. To maintain the integrity of the signals over 1.584 GHz, pre-distorting the waveform becomes necessary, therefore the need to calibrate the whole system. Basic Method The basic method of reference calibration is to generate a known (golden) signal using the correction device (an AWG) to the appropriate measurement device (an oscilloscope). Capturing and comparing the measured signal to the golden reference will make it possible to obtain the appropriate correction data for both amplitude and phase. 2 www.tektronix.com/signal_generators

Creating Calibrated UWB WiMedia Signals Figure 2. Channel Estimation Signal. Golden Reference Signal The calibration procedure requires generating a signal with known amplitude and phase distributions over the band of interest. Additionally, it is highly desirable that the signal shows the representative PAPR (Crest Factor) to contain the effect of non-linearities in the system so that the total system performance can be represented. This will result in a higher repeatability and accuracy while lowering the number of averages and processing time to reach the expected results. A candidate signal meeting these criteria is the channel estimation sequence as defined in the UWB-MB-OFDM WiMedia standard, as shown in Figures 2 and 3. It shows the following characteristics: Frequency components are limited to the location of the OFDM carriers defined for UWB-MB-OFDM signals. All the carriers show the same amplitude. Phase distribution is known and phase values are limited to four different levels (-135º, -45º, 45º, and 135º) easing the handling of phase wrapping and estimating fine delay. Peak-to-Average-Power-Ratio (PAPR) is just 5.8 db. As the time-domain signal is obtained by performing an IFFT over a strictly defined frequency-domain amplitude and phase distribution, it can be seamlessly sequenced without any spectral leakage effect. Figure 3. Reference Signal: Channel Estimation Signal after modulation. Acquisition Requirements Signals to be analyzed must be acquired through an oscilloscope with a sufficient sampling rate. This means that the total signal content must be within the Nyquist frequency (Sr/2). The capability of a Tektronix real-time oscilloscope with enhanced bandwidth (DSP-based technology) is required to acquire the signals. Signals are acquired at the maximum sampling rate so as to get the best amplitude/phase response necessary for high accuracy calibration. The record length must be selected to obtain enough frequency-domain resolution. Additional acquisition time must be allowed for, in order to get precise FFT analysis window positioning (alignment) without the requirement for an additional trigger signal. www.tektronix.com/signal_generators 3

Application Note Analysis Methods Frequency domain analysis for UWB signals may be performed on the raw time-domain signal or after demodulation and/or downconversion. The latter method must be performed when a real complete UWB signal is used for calibration, as this is the only way to reach the required frequency domain resolution over a single symbol (128 samples). Raw time-domain signal analysis is feasible only when the signal repeats so that the required frequency domain resolution can be obtained by extending the analysis over a high number of symbols. This is the case with a previously defined calibration signal. Raw time-domain signal analysis is highly desirable as it avoids many of the side effects of direct digital down conversion (typically implemented by under sampling/decimation) such as image rejection, poor signal-to-average-noise ratio, and susceptibility to aliased signals. The RFXpress software uses the raw time-domain signal analysis because this gives the best possible calibration results. Frequency Analysis Resolution and Time Domain Window Selection Basic resolution in FFT based analysis is obtained by dividing the acquisition sampling rate by the number of samples used in DFT calculations. Sample Rate Record Length Record Length @ Df = 400 KHz @ Df = 300 KHz 20 GSamples/s >50,000 samples >67,000 samples 25 GSamples/s >62,500 samples >85,000 samples 40 GSamples/s >100,000 samples >133,000 samples 50 GSamples/s >125,000 samples >167,000 samples Table 1. Minimum record lengths to obtain FFT resolution of 400 KHz and 300 KHz. Accurate and useful analysis requires the resolution to be better than the UWB basic carrier spacing (4,125,000 Hz). Complete carrier separation and accuracy necessitates using time-domain windows to improve the flatness of the resulting frequency domain data. Flat-top window is especially desirable as it gives an excellent amplitude (and phase) accuracy (0.01 db) so it eliminates the undesired scallop effect. Unfortunately, flat-top window is not very selective in the frequency domain. If the 60 db attenuation bandwidth (9.1 Df) is taken as a reference, then Df should be better than 10 times the OFDM basic carrier spacing leading to a value around 400 KHz. The following table shows the minimum record length for different combinations of sampling rates to obtain an FFT resolution of 400 KHz and 300 KHz. Acquisition Sampling Rate Re solution = Number Of Samples 4 www.tektronix.com/signal_generators

Creating Calibrated UWB WiMedia Signals Sample Rate Reference Record Length Sample Rate Record Length 20 GSamples/s 4848 samples 25 GSamples/s 6061 samples 40 GSamples/s 9697 samples 50 GSamples/s 12121 samples 20 GSamples/s 65536 + 2424 = 67960 samples 25 GSamples/s 65536 + 3031 = 68567 samples 40 GSamples/s 131072 + 4849 = 135921 samples 50 GSamples/s 131072 + 6061 = 137133 samples Table 2. Sample rate and corresponding reference signal length. Table 3. Sample rate and corresponding record length. Time-domain Alignment Correct phase analysis requires applying the FFT algorithm to signals properly aligned in the time domain. Although phase analysis could be theoretically obtained by using standard hardware techniques such as triggering, this option is not desirable for the following reasons: It requires a second connection between the AWG being calibrated and the calibration oscilloscope for the synchronization signal. Even to connect that signal, proper alignment will require precise delay adjustment to compensate for differential delay including the effect of different bandwidth. Marker signals may inject some jitter due to their timing granularity. Signal correlation is an alternative method that does not show any of the above problems. Correlation compares a signal with another. When similar signals are aligned in time, the output of correlation shows a peak. The proposed alignment method takes a reference signal consisting of a single channel estimation symbol modulated at the target carrier frequency. For a given oscilloscope acquisition there will be several alignment events, as the signal repeats seamlessly. In any case, as the record length will be slightly larger than the FFT analysis length, the correlation should be limited to the central region of the acquisition. There will be one perfect alignment setting in ±(Reference Signal Length)/ 2 samples around the central location. Limiting the search area also speeds up the process as correlation is time consuming. Acquisition Sampling Rate 128 Reference Signal Length = 528 MHz It is necessary that the length of the acquired signal contains at least one FFT frame and the FFT frame be a power of 2. The analysis area may be shifted by half the reference signal length. The minimum acquisition length that would be required to be captured on the oscilloscope so as to obtain an FFT resolution in the region of 300-400 KHz is given above. www.tektronix.com/signal_generators 5

Application Note Figure 4. Correlation signal over the entire record length. Figure 5. Correlation signal in the central region. Correlation The correlation algorithm consists of multiplying the samples in the reference signals by the corresponding samples in the analyzed waveform to obtain one of the samples of the correlation waveform. The same process is repeated around the area of interest by shifting the analysis window by one sample. The region to cover is the central area of the acquired signal and the size of the area is equal to the reference signal length. The correlation waveform will show peaks when the reference signal is properly aligned. There are positive and negative peaks due to the instantaneous carrier phase alignment between both waveforms. The search algorithm takes the absolute value of the correlation signal and looks for the maximum value. The obtained value will define the FFT analysis area. Figures 4 and 5 show the correlation signal over the entire record length and in the center region respectively. 6 www.tektronix.com/signal_generators

Creating Calibrated UWB WiMedia Signals Figure 6. Magnitude plot. Figure 7. Phase plot. Raw Data Processing Once the analysis region is selected, the FFT algorithm is applied to the real values of that region. The resulting real and imaginary values must be processed to obtain the required magnitude and phase values. This process may take place between the complete frequency domain waveform or just at the discrete frequencies of interest. Magnitude and phase are obtained using the following equations: Figures 6 and 7 show the amplitude and phase plot obtained using the above equations. Amplitude calculation is straightforward. The phase process requires an extra step because phases are shifted π*i as the signal is shifted by half the analysis length. The Phase shift may be handled by adding 180º to every two samples. 2 2 10 i Amplitude [ i[ = 10 log ( real[ i] + Imag[ ] Phase [ i] = arctg( imag[ i], real[ i]) ) Where arctg is a four quadrant arctangent function. www.tektronix.com/signal_generators 7

Application Note Figure 8. Phase response showing 180 shift. Figure 9. Phase after shift removal. Phase Wrapping Handling Ideal channel estimation signals show phases transitioning between +135º and -45º for the lower sideband and +45º and -135º for the upper sideband. Actual values in the resulting phase waveform will not follow this range due to the following reasons: Absolute phase will depend on the carrier phase that should be seen as random value. Tiny residual group delay coming from alignment errors due to the timing granularity of the correlation process. Phase impairments - these values are to be obtained by the algorithm. The combined phase shift may take the absolute values to go beyond the arctangent function limits of ±180º, making it important to take care of the phase wrapping effects. An evident solution is processing the phase waveform to unwrap it before calculating the correction. This solution and the additional phase normalization (so average phase =0) is necessary to show the right phase values in graphs as shown in Figures 8 and 9. A simpler, more straightforward solution is processing the error signal. Basically it takes the following steps: For each carrier frequency the raw difference between the ideal and actual carrier phase is obtained. This value may range from -360º up to +360º. These phase differences must be limited to the ±180º range by adding or subtracting 360º to the value if it goes under -180º or over +180º. The resulting raw phase correction array may be shifted to its average value so the common phase error component is eliminated and the overall correction is minimized. 8 www.tektronix.com/signal_generators

Creating Calibrated UWB WiMedia Signals Arbitrary Waveform Generator Oscilloscope CH1: Interleave Channel Figure 10. Instrument setup. Amplitude Processing Although amplitude processing is straightforward, correction data cannot be obtained from the relative errors around the average value at a given band within a band group. The reason is that doing so will result in amplitude imbalances between different bands in the same band group, which will show up as amplitude changes as the signal hops. This means that the absolute values must be stored and processed at correction time to normalize the amplitude to all the bands at the same consistent value. Using RFXpress to Calibrate the System for WiMedia Signal Generation from an AWG7122B This note provides for a procedure to generate and apply corrections for distortions in the system while generating Direct RF WiMedia signals using an AWG7122B with product option 06, Interleave operation with up to a 24 GS/s sample rate. In this example procedure we will generate a WiMedia compliant Band Group 5 UWB signal. Instruments needed: The Tektronix AWG7122B with option 06 is used to generate the RF WiMedia signal. The Tektronix oscilloscope is used to capture the signal. Instrument Setup The AWG7122B is operated in the interleave mode. The AWG interleave output channel is connected to channel 1 of the Tektronix oscilloscope as shown in the instrument set up in Figure 10. Note: Make sure that the instruments are individually calibrated using the calibration verification procedures provided in the instruments. www.tektronix.com/signal_generators 9

Application Note Figure 12. Warning message. Figure 11. Calibration dialog. Procedure to Generate the Correction File 1. In RFXpress, select WiMedia Application. Click Calibration and the following dialog, as shown in Figure 11, will guide you through the calibration process. 2. Select the Signal Type as RF. 3. The list in the grid is populated with instruments found on the local subnet with their Model, Status, Connection Type and Name (Alias). For example, select the oscilloscope (as shown in Figure 11), then select Connect, and the Status will update to Connected. 4. Select Interleave, in order to generate signals with sampling rates of 23.993786 GS/s. 5. The Sample Rate field is used to set the AWG sample rate. Set the sample rate to 23.993786 GS/s. 6. The Average field is used to generate statistically averaged correction data by multiple captures of the signals on the oscilloscope. Set the Average to 10. 7. Set the Band Group to Band Group 5. 8. Select the band to be calibrated. Note that the Band Frequencies are calculated in accordance with the WiMedia specifications, that is: Band Group Center Frequency -528 MHz, Band Group Center Frequency and Band Group Center Frequency +528 MHz. 9. Select the channel (channel 1) for which the correction file is to be generated. 10. Set the Amplitude for channel 1 to 0.5 Vpp. 11. Under the select Correction File provide the path and the file name where the correction data is to be stored. 12. Click the Calibrate button. 13. An alert message, as in Figure 12, appears, prompting you to check the connection. Check the connection and click continue. 14. Note that during calibration, the AWG will be re-set to the factory default state. 15. Test signals will be generated for each of the bands and captured from the oscilloscope. When using RFXpress, the status of the entire process is shown in the calibration dialog. 16. The Error Correction for the setup is generated and stored in a file with extension *.rfc. 10 www.tektronix.com/signal_generators

Creating Calibrated UWB WiMedia Signals Figure 13. Spectrum before calibration. Figure 14. Spectrum after calibration. Applying the Correction File 1. To apply the correction, in the Calibration menu select the correction file just generated and click OK. 2. Generate a WiMedia signal with following specs: a. Select IF/RF as the Signal format b. Select the WiMedia example packet from Setup c. Set the Band Group to Band Group 5. (Band Group 5 Center Frequency of 10296 MHz.) 3. In Compile Settings, set the Over sampling to 3.60, which will set the sampling rate to 23.993786 GS/s. Make sure CH1 is selected under Correction File. 4. Compile. 5. The Correction will be applied to the UWB WiMedia waveform created. Summary This application note described the procedure that can be used for signal path calibration when applied to UWB signal generation using: Direct RF signal generation IF signal generation using an upconverter Solutions such as AWG Series arbitrary waveform generators with RFXpress software tools were explained. To maintain the integrity of the signals over the whole band, pre-distorting the waveform becomes necessary, therefore the need to calibrate the whole system. Examples of pre-and post-calibration are shown in Figures 13 and 14. Figure 13 shows the spectrum of the Band Group 5 signal captured on the oscilloscope and analyzed using the Tektronix UWB oscilloscope software. This degradation in the frequency response of the Band Group 5 signal is due to the analog bandwidth upper boundary of the AWG. This kind of difference in the spectrum could also arise due to the bandwidth of the cables. Figure 14 shows the spectrum after correction is applied to the signal. Now the flatness of the signal is improved. Similar to the direct sampling advantage of oscilloscopes, the AWG utilizes direct RF synthesis which can minimize the need for continued calibration. Controlled thermal behavior, low drift in time, and lack of external equipment can allow a calibrated signal to remain within acceptable limits over a long period of time. www.tektronix.com/signal_generators 11

Contact Tektronix: ASEAN / Australasia (65) 6356 3900 Austria +41 52 675 3777 Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777 Belgium 07 81 60166 Brazil & South America (11) 40669400 Canada 1 (800) 661-5625 Central East Europe, Ukraine and the Baltics +41 52 675 3777 Central Europe & Greece +41 52 675 3777 Denmark +45 80 88 1401 Finland +41 52 675 3777 France +33 (0) 1 69 86 81 81 Germany +49 (221) 94 77 400 Hong Kong (852) 2585-6688 India (91) 80-22275577 Italy +39 (02) 25086 1 Japan 81 (3) 6714-3010 Luxembourg +44 (0) 1344 392400 Mexico, Central America & Caribbean 52 (55) 5424700 Middle East, Asia and North Africa +41 52 675 3777 The Netherlands 090 02 021797 Norway 800 16098 People s Republic of China 86 (10) 6235 1230 Poland +41 52 675 3777 Portugal 80 08 12370 Republic of Korea 82 (2) 6917-5000 Russia & CIS +7 (495) 7484900 South Africa +27 11 206 8360 Spain (+34) 901 988 054 Sweden 020 08 80371 Switzerland +41 52 675 3777 Taiwan 886 (2) 2722-9622 United Kingdom & Eire +44 (0) 1344 392400 USA 1 (800) 426-2200 For other areas contact Tektronix, Inc. at: 1 (503) 627-7111 Updated 12 November 2007 For Further Information Tektronix maintains a comprehensive, constantly expanding collection of application notes, technical briefs and other resources to help engineers working on the cutting edge of technology. Please visit www.tektronix.com Copyright 2008, Tektronix. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks or registered trademarks of their respective companies. 08/08 DM 76W-20861-1