Assembly. Front view. Power Rail

Similar documents
Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Assembly. Front view. Switch Power Rail

Assembly. Front view. Switch Power Rail

Assembly. Front view. DIP switch. LED yellow: Relay output 1. LED yellow: Relay output Power Rail

Connection. Input EEx ia IIC. Input I. Input II R 1 R 1 A B A 2+ B LB SC. yellow. red. Composition

Assembly. Front view. DIP switch. LED yellow: Relay output I. LED yellow: Relay output II. Potentiometer Hysteresis relay I Power Rail

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

Assembly. Front view. HiC2441. SL2 1b. Termination Board

Assembly. Front view. Parametrization interface. Power Bus

Connection. Thermocouple. Output (4 ma ma) Power supply Power Rail. Composition

Connection. Composition

Temperature Transmitter itemp RTD DIN rail TMT 127

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring

Temperature transmitter itemp PCP DIN rail TMT 121

Isolating Repeater Input Series 9163

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

itemp HART DIN rail TMT112

Temperature transmitter itemp RTD DIN rail TMT 127

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

itemp PA TMT184 Technical information

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

Technical Information Barrier RB223

Signal conditioner - MACX MCR-UI-UI-NC

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

0 2 1 â Ó. itemp HART TMT182. Technical Information

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

0 2 1 â Ó. itemp HART TMT182. Technical Information

Binary Output without Power Supply Series 9176

Isolators A3/1. Vibration Transducer Supply Unit Series

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Temperature Input Module for Zone 1 Series 9482/32

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Binary Output Series 9175

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Temperature Transmitters TMT 136, TMT 137

Isolators A3/1.

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

Temperature head transmitter itemp TC TMT 188

Technical Data. General specifications. Rated operating distance s n 3 mm

Head mounted Temperature Transmitter TF02/TF02-Ex

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Safety Barriers 2/1. Hazardous area. 250 V max I.S.

PRetrans Table of contents

Inductive sensor slot-type SI2-K08-AP7

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

MINI MCR-SL-UI-I-LP-NC

K AS-Interface. K Test input

Rail mounted Temperature Transmitter TH102/TH102-Ex

Positioner with HART Communication Type 3780

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Assembly 249 (9.80) 259 (10.2) Example: level probe with Pt100 and HUT temperature head transmitter ( ma) ma. Core colors: RD BK YE BU

Temperature head transmitter itemp PCP TMT 181

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

SINEAX B 811 Power Pack with additional Functions

SINEAX TI 807 Passive DC signal isolator

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

SALES SERVICE +358 (0)

Plug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Single-Channel Safety Barriers Series 9001

MINI MCR-SL-UI-f(-SP)

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

Analog Universal Module HART for Zone 2 Series 9468/33

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

CATALOGUE ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES ATEX

Level Limit Switch nivotester FTL 370, FTL 372

STT 3000 Smart Temperature Transmitter Series STT170 Specifications

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Temperature Measurement

Rosemount 148 Temperature Transmitter

R88000 T (including ATEX)

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

OPTITEMP TT 10 C/R Technical Datasheet

Digital Input Output Module for Zone 2 Series 9470/33

Resistance thermometer Model TR30, compact design

FieldIT Temperature Transmitter, head mounted TH02/TH02-Ex

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

User and Safety Manual ProLine P224xx P1

Level Measurement. Applications. Special features. Description

Isolators A3/1.

OPTIFLUX 5000 Technical Datasheet

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

RLK39-54/31/40a/116 with terminal compartment

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Digital temperature transmitter with HART protocol Model T32.1S, head mounting version Model T32.3S, rail mounting version

Transcription:

Thermometer Resistance Repeater Features Assembly 1-channel isolated barrier 24 V DC supply (Power Rail) RTD/resistance input Resistance output Accuracy 0.1 % Front view Removable terminals blue Function 1 2 3 4 5 6 This isolated barrier is used for intrinsic safety applications. It transfers RTD resistance values from hazardous areas to safe areas. A 2-, 3-, or 4-wire mode is available depending on the required accuracy. The configuration must be the same in the hazardous and safe area. The monitor registers the same load as if it were connected directly to the resistance in a hazardous area. All resistive sensors are connectable as long as the limit "measurement current x (R m + 900 Ω) < 10 V" is not exceeded and the measurement voltage is smaller than 7 V. 7 10 8 11 9 12 Removable terminals green Connection Zone 0, 1, 2 Div. 1, 2 4 3 1 2 5 V+ I+ I- V- 24 V DC Power Rail 9+ 10+ 11-12- 7+ 8-24 V DC Zone 2 Div. 2 Pepperl+Fuchs Group Tel.: Germany +49-621-776-0 USA +1-330-4253555 Singapore +65-67-799091 Internet www.pepperl-fuchs.com 1

General specifications type Supply Analog input Connection Power Rail or terminals 7+, 8- Rated voltage 20... 35 V DC Ripple within the supply tolerance Rated current < 20 ma Power loss 0.25 W (24 V and 1 ma sense current) Input Connection terminals 1, 2, 3, 4, 5 Line resistance 10 % of resistance value Transmission range 0... 10 ma Available voltage 9 V Output Connection terminals 12-, 11-, 10+, 9+ Current 0... 10 ma Available voltage 0... 7 V Transfer characteristics Deviation I m 1 ma: ± 0.1 % of R m or ± 0.1 Ω (the larger value is applicable) I m < 1 ma: accuracy reduces in proportion to I m. e. g. I m = 0.1 ma: ± 1 % of R m or 1 Ω (the larger value is applicable). Influence of ambient temperature I m 1 ma, R m 100 Ω : 0.01 % / K in the range -20... +60 C (253... 333 K) I m < 1 ma or R m < 100 Ω: temperature stability reduces in proportion to I m or R m Rise time signal response time 2 ms (10... 90 %) response to application of I m : R m > 50 Ω and I m < 5mA: < 5ms response to application of I m : R m > 30 Ω and I m < 5mA: < 10ms response to application of I m : R m > 18 Ω and I m < 5mA: < 20ms Electrical isolation Output/power supply basic insulation acc. to EN 50178, rated insulation voltage of 50 V AC Directive conformity Electromagnetic compatibility Directive 2004/108/EC EN 61326-1:2006 Conformity Insulation coordination EN 50178 Electrical isolation EN 50178 Electromagnetic compatibility NE 21 Protection degree IEC 60529 Ambient conditions Ambient temperature -20... 60 C (253... 333 K) Mechanical specifications Protection degree IP20 Mass approx. 100 g Dimensions 20 x 107 x 115 mm (0.8 x 4.2 x 4.5 in), housing type B1 Data for application in conjunction with hazardous areas EC-Type Examination Certificate BAS 01 ATEX 7282, for additional certificates see www.pepperl-fuchs.com Group, category, type of protection II (1)GD [EEx ia] IIC (-20 C T amb 60 C) Voltage U o 12.4 V Current I o 17 ma Power P o 53 mw Supply Safety maximum voltage U m 250 V (Attention! The rated voltage can be lower.) Type of protection [EEx ia] Output Safety maximum voltage U m 250 V (Attention! The rated voltage can be lower.) Statement of conformity TÜV 99 ATEX 1499 X, observe statement of conformity Group, category, type of protection, II 3G EEx na II T4 temperature classification Electrical isolation Input/output safe electrical isolation acc. to EN 50020, voltage peak value 375 V Input/power supply safe electrical isolation acc. to EN 50020, voltage peak value 375 V Directive conformity Directive 94/9/EC EN 50014, EN 50020, EN 50021 International approvals FM approval Control drawing 116-0129 Pepperl+Fuchs Group Tel.: Germany +49-621-776-0 USA +1-330-4253555 Singapore +65-67-799091 Internet www.pepperl-fuchs.com 2

UL approval Control drawing 116-0173 (culus) CSA approval Control drawing 116-0132 General information Supplementary information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperlfuchs.com. Pepperl+Fuchs Group Tel.: Germany +49-621-776-0 USA +1-330-4253555 Singapore +65-67-799091 Internet www.pepperl-fuchs.com 3

Additional information Function When a signal, a DCS or PLC is connected to terminals 9, 10, 11, and 12 (control side), the measuring current is transferred to terminals 1 and 2 (field side). The resulting voltage at terminals 3, 4, and 5 is transferred to terminals 9, 10, 11, and 12. In the case of fast multiplex input cards, transmission problems might be experienced in connection with low resistance values and/or high sensor currents. For data see rise time. Connection types control side (safe area) 2-wire mode 3-wire mode negative measuring line 3-wire mode positive measuring line 4-wire mode 9 10 11 12 9 10 11 12 9 10 11 12 9 10 11 12 Measurement range The resistance repeater can convey a maximum of 10 ma and a maximum of 7 V. The maximum connectable resistance value can be derived from the following equation: Resistance value = 7 V/measuring current The measuring current is determined by control. Measuring current I (ma) 10 8 6 4 2 0.5 2 4 6 8 10 12 14 kω max. Resistance Temperature sensor An example of the maximum transferable resistance value: 14 kω at 0.5 ma measuring current 3.5 kω at 2 ma measuring current Accessories Power feed modules KFD2-EB2... The power feed module is used to supply the devices with 24 V DC via the Power Rail. The fuse-protected power feed module can supply up to 100 individual devices depending on the power consumption of the devices. A galvanically isolated mechanical contact uses the Power Rail to transmit collective error messages. Power Rail UPR-03 The Power Rail UPR-03 is a complete unit consisting of the electrical inset and an aluminium profile rail 35 mm x 15 mm. To make electrical contact, the devices are simply engaged. The Power Rail must not be fed via the device terminals of the individual devices! Pepperl+Fuchs Group Tel.: Germany +49-621-776-0 USA +1-330-4253555 Singapore +65-67-799091 Internet www.pepperl-fuchs.com 4

Pepperl+Fuchs Group Tel.: Germany +49-621-776-0 USA +1-330-4253555 Singapore +65-67-799091 Internet www.pepperl-fuchs.com 5