HMI Components. Series. Raised design PCB (with adaptor) Machinery and Automation. Indicator Illuminated pushbutton

Similar documents
HMI Components. Series. Flush design Raised design PCB (with adaptor) Indicator Pushbutton Illuminated pushbutton

HMI Components. Series

EAO Product Information. Series 84

Accessories. Accessories

OMRON MK-I / -S RELAY

Model Number Structure

Snap Action Switches Technical Guide

General-purpose Relay

Operator Heads: ø 22mm

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

Control Stations ø 22

Complete units: Mushroom heads ø 22mm

Complete units: Push-buttons ø 22mm

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

RU Series Universal Relays

Q6 series. Ø6 mm panel mount LED indicators DISTINCTIVE FEATURES ENVIRONMENTAL SPECIFICATIONS GENERAL SPECIFICATIONS MATERIALS MOUNTING LED INDICATORS

Complete units: Selector switches ø 22mm

62 Series - Power relays 16 A. Features / /

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

General-purpose Relay

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES

DPDT MY2N-D2 MY2IN-D2 --- (DC only) 4PDT MY4N-D2 MY4IN-D PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- With built-in CR

2 or 4 pole changeover contact Plug-in/Faston 187

Operator Heads: ø 22mm

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

Separate units: Blocks

PHOENIX CONTACT

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

PHOENIX CONTACT

Indicator actuator, white bezel, IP40 front protection, 16mm mounting - Indicator element, mounting flange and LED needed for complete unit

Round Indicator Lights Mounting Hole Page

HMI Components. Series. Front mounting Glass mounting. Illuminated pushbutton Indicator Warning indicator Emergency call button. Public transportation

62.22 Copper side view

PCB relay for DC voltage, polarized, monostable or bistable

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES resistance ORDERING INFORMATION. Ex. DSP 1 L DC12V R

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

Relays & Sockets. RF2V 2-Pole Force Guided Relays/SJ Series Relay Sockets. UL/Recogntion File No. E55996 TÜV SÜD. EU Low Voltage Directive

62 Series - Power relays 16 A. Features SERIES / / Printed circuit mount 16 A Power relay

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

Electronic Circuit Breaker with reset input ESS20-1..

Solid-state Timer H3DS

Electronic Circuit Protector ESX10-T

Electronic Step Controller

Solid-State Digital Counter H7AN

Details on the New G2RS

Relays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection

SMT TR series. Surface mount tiny washable rocker switches. Distinctive features and specifications.

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

4 AMP POLARIZED HIGH DENSITY RELAY WITH HIGH SENSITIVITY FEATURES

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

PHOENIX CONTACT - 09/2009

MINIATURE RELAY FOR WIDER APPLICATIONS

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category


High Capacity of Max. 1,000 V DC Cut-off Possible

Classification Contact form Contact type Contact material Enclosure Rating Model Standard DPDT Bifurcated crossbar Ag (Au alloy) Fully sealed G5V-2

No-wear isolation of potentials in terminal block design

Data Sheet for Precision Potentiometer

Slim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type

UNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY. UL File No.: E43149 CSA File No.: LR26550

All-or-nothing relay RH(M) 1000 in plug-in case and case for top-hat rail or wall mounting

RELOG. All-or-nothing Relay

550-xx mm LED CBI. Circuit Board Indicator Square Back Housing, Tri-Block x x x 3

Relay for control panel of 1c 10A, 2c 5A and 1a 16A

Rotary Measurement Technology Incremental Encoders

LED Driver Linear / area fixed output

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

SLIM COMPACT SAFETY RELAY

Datasheet. Electronic Circuit Protection ESX10-T

Safety switches with slotted hole lever

8 A MINIATURE POWER RELAY IN DS RELAY SERIES

Compact size 2 Form A and 2 Form A 1 Form B 35A power relays for energy management and industrial equipment. Conditions. Mirror contact mechanisms

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal

8 A MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

550-xx mm LED CBI. Circuit Board Indicator Sloped Back Housing, Quad Block x x x 4

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

Phase-sequence Phase-loss Relay

Slim compact safety relay

LED Driver Compact dimming

Relay for control panel of 1c 10A, 2c 5A and 1a 16A

Model Number Structure

550-xx07. 5mm LED CBI Circuit Board Indicator Sloped Back Housing with Standoffs x x Features

Electronic Circuit Breaker ESS20-0..

Data Sheet for Angle Sensors

PROXIMITY SENSOR TERMINOLOGY

LED Driver Compact dimming

PHASED OUT. LED Driver Compact dimming. Driver LCAI 55W 900mA 1750mA ECO C ECO series

Remote Sensor Amplifier Terminal

20 Series Power Relays

APEM COMPONENTS LIMITED

Modular step relays 16 A

Transcription:

Edition 10/2016 HMI Components 41 Series Characteristics The rectangular design of the Series 41 (18 x 24 mm) makes it especially suited: Raised design PCB (with adaptor) Functions The Series 41 incorporates the following functions: Indicator Illuminated pushbutton Market segments The EAO Series 41 is especially suited for applications in the segment: Machinery and Automation The series features a compact double-lit element that can be fitted from the front as a snap-on module. Please refer to the EAO website to obtain detailed information regarding this series www.products.eao.com Configure a product to your exact needs and request a quotation.

Content 41 Overview Raised design Indicator 4 Illuminated pushbutton 5 Accessories 7 Drawings 14 Technical data 15 Marking 17 Guidelines for use 18 Index 19 3

41 Raised design Indicator, IP 40 3 max. Equipment consisting of (schematic overview) Lens page 7 L H 2 LEDs page 10 10.5 27.5 3 43.5 Actuator Product can differ from the current configuration. Dimensions [mm] L = Solder terminal, H = Universal terminal 2.0 x 0.5 mm Each Part Number listed below includes all the black components shown in the 3D-drawing. To obtain a complete unit, please select the red components from the pages shown. Mounting cut-outs [mm] Terminal Part No. Wiring diagram Weight Indicator, Front dimension 18 x 24 mm Solder 41-040.005 1 0.009 kg Indicator, Front dimension 18 x 24 mm Universal 2.0 x 0.5 mm 41-041.006 1 0.009 kg x1+ x2+ x3- x4- Wiring diagram 1 4

Raised design 41 Illuminated pushbutton, IP 40 Equipment consisting of (schematic overview) 3 max. Lens page 7 2 LEDs page 10 L H Actuator 10.5 36.5/44/51.5/59 3 43.5 Each Part Number listed below includes all the black components shown in the 3D-drawing. To obtain a complete unit, please select the red components from the pages shown. Dimensions [mm] L = Solder terminal, H = Universal terminal 2.0 x 0.5 mm Product can differ from the current configuration. Mounting cut-outs [mm] Switching system Contacts Switching action Terminal Part No. Wiring diagram Weight Illuminated pushbutton, Front dimension 18 x 24 mm Snap-action switching element 1 NC + 1 NO B Solder 41-121.0252 1 0.011 kg C Solder 41-261.0252 2 0.011 kg 2 NC + 2 NO B Solder 41-122.0252 3 0.012 kg C Solder 41-262.0252 4 0.013 kg 3 NC + 3 NO B Solder 41-123.0252 5 0.014 kg C Solder 41-263.0252 6 0.014 kg 4 NC + 4 NO B Solder 41-124.0252 7 0.015 kg C Solder 41-264.0252 8 0.015 kg Illuminated pushbutton, Front dimension 18 x 24 mm Low-level element 2 NO B Universal 2.0 x 0.5 mm 41-421.036 9 0.014 kg Contacts: NC = Normally closed, NO = Normally open Switching action: B = Momentary, C = Maintained C Universal 2.0 x 0.5 mm 41-461.036 10 0.014 kg 2 NC B Universal 2.0 x 0.5 mm 41-422.036 11 0.014 kg C Universal 2.0 x 0.5 mm 41-462.036 12 0.014 kg 1 NC + 1 NO B Universal 2.0 x 0.5 mm 41-423.036 13 0.014 kg C Universal 2.0 x 0.5 mm 41-463.036 14 0.014 kg 5

41 Raised design 1 3 x1+ I x2+ 1 3 x1+ I x2+ 1 3 1 3 x1+ I II x2+ 2 4 x3- x4-2 4 x3- x4-2 4 2 4 x3- x4- Wiring diagram 1 Wiring diagram 2 Wiring diagram 3 1 3 1 3 x1+ I II x2+ 1 3 1 3 1 3 x1+ I II III x2+ 2 4 2 4 x3- x4-2 4 2 4 2 4 x3- x4- Wiring diagram 4 Wiring diagram 5 1 3 1 3 1 3 x1+ I II III x2+ 1 3 1 3 1 3 1 3 x1+ I II III IV x2+ 2 4 2 4 2 4 x3- x4-2 4 2 4 2 4 2 4 x3- x4- Wiring diagram 6 Wiring diagram 7 1 3 1 3 1 3 1 3 x1+ I II III IV x2+ 1 3 a+ b+ 1 3 a+ b+ 2 4 2 4 2 4 2 4 x3- x4-2 4 a'- b'- 2 4 a'- b'- Wiring diagram 8 Wiring diagram 9 Wiring diagram 10 1 3 a+ b- 1 3 a+ b- 1 3 a+ b+ 1 3 a+ b+ 2 4 a'- b'- 2 4 a'- b'- 2 4 a'- b'- 2 4 a'- b'- Wiring diagram 11 Wiring diagram 12 Wiring diagram 13 Wiring diagram 14 6

Accessories 41 Front Lens plastic single-colour Product attribute Dimension Lens Part No. Weight Lens plastic single-colour flat, illuminative 15.3 x 21.5 mm red transparent 41-903.2 0.001 kg orange transparent 41-903.3 0.001 kg yellow transparent 41-903.4 0.001 kg green transparent 41-903.5 0.001 kg blue transparent 41-903.6 0.001 kg colourless transparent 41-903.7 0.001 kg flat, illuminative, less suitable for film insert 15.3 x 21.5 mm red transparent 41-904.2 0.001 kg orange transparent 41-904.3 0.001 kg yellow transparent 41-904.4 0.001 kg green transparent 41-904.5 0.001 kg colourless transparent 41-904.7 0.001 kg Lens plastic bi-colour Product attribute Dimension Lens Part No. Weight Lens plastic bi-colour flat, illuminative 15.3 x 21.5 mm red-orange transparent 41-907.2/3 0.002 kg red-yellow transparent 41-907.2/4 0.002 kg red-green transparent 41-907.2/5 0.002 kg red-colourless transparent 41-907.2/7 0.002 kg orange-green transparent 41-907.3/5 0.002 kg orange-blue transparent 41-907.3/6 0.002 kg orange-colourless transparent 41-907.3/7 0.002 kg yellow-green transparent 41-907.4/5 0.002 kg yellow-blue transparent 41-907.4/6 0.002 kg yellow-colourless transparent 41-907.4/7 0.002 kg green-blue transparent 41-907.5/6 0.002 kg green-colourless transparent 41-907.5/7 0.002 kg colourless-colourless transparent 41-907.7/7 0.002 kg flat, illuminative, less suitable for film insert 15.3 x 21.5 mm red-orange transparent 41-908.2/3 0.002 kg red-green transparent 41-908.2/5 0.002 kg flat, illuminative, less suitable for film insert 15.3 x 21.5 mm yellow-green transparent 41-908.4/5 0.002 kg colourless-colourless transparent 41-908.7/7 0.002 kg 7

41 Accessories Protective cover, IP 40 Additional Information Hinged, with means for sealing 12.75 Front panel thickness reduces by 2 mm Please note that bigger minimum distances are necessary 24.5 10.2 42.5 25.5 14 32 Dimensions [mm] Product attribute Dimension Material Optics Part No. Weight Protective cover for button with front dimension 15 x 21 mm 18 x 24 mm Plastic transparent 41-925 0.002 kg Blind plug Einbauöffnungen [mm] Dimension Material Colour Part No. Weight Blind plug 18 x 24 mm Plastic black 41-947.0 0.002 kg 8

Accessories 41 Rear side PCB plug-in base Dimension Pins Terminal Part No. Weight PCB plug-in base 23.8 x 17.7 x 9.8 mm axial PCB 41-940 0.004 kg The component layouts you will find from page 14 Flat receptacle Product attribute Part No. Weight Flat receptacle 2.0 x 0.5 mm plug-in terminal 31-945 0.001 kg Insulation sleeve Product attribute Part No. Weight Insulation sleeve for flat receptacle 2.0 mm 31-928 0.001 kg 9

41 Accessories Illumination LED, T1 3/4 MG Additional Information Due to high surface temperatures, the series resistor must not be soldered directly to the terminals of the equipment (use a terminal plate) 16 max. Order two LEDs When using AC/DC types with AC operation, slight flickering can occure Luminous intensity data of the LEDs on direct voltage Electrical and optical data are measured at 25 C The specified versions are built with a protection diode (halve wave rectifier) in series and the LED Luminosity and wave length variations caused by LED manufacturing processes may cause slight differences regarding the illumination If the 24VDC Bi-colour lamp is driven with normal polarity (plus on middle contact of the lamp) the first mentioned colour will light up, with inverted polarity the second colour will ligth up Dimensions [mm] Ø6.1 max. LED colour Operating voltage Operation current Lumi. intensity Dom. wavelength Part No. Weight Single-LED Single-LED red 6 VDC +10 % 15 ma ±15 % 350 mcd 630 nm 10-2J06.3142 0.002 kg 12 VAC/DC +10 % 7/14 ma ±15 % 330 mcd 630 nm 10-2J09.1062 0.002 kg 24 VAC/DC +10 % 7/14 ma ±15 % 330 mcd 630 nm 10-2J12.1062 0.002 kg 28 VAC/DC +10 % 7/14 ma ±15 % 330 mcd 630 nm 10-2J13.1062 0.002 kg 48 VAC/DC +10 % 4/8 ma ±15 % 200 mcd 630 nm 10-2J19.1042 0.002 kg Single-LED yellow 6 VDC +10 % 15 ma ±15 % 300 mcd 587 nm 10-2J06.3144 0.002 kg 12 VAC/DC +10 % 7/14 ma ±15 % 280 mcd 587 nm 10-2J09.1064 0.002 kg 24 VAC/DC +10 % 7/14 ma ±15 % 280 mcd 587 nm 10-2J12.1064 0.002 kg 28 VAC/DC +10 % 7/14 ma ±15 % 280 mcd 587 nm 10-2J13.1064 0.002 kg 48 VAC/DC +10 % 4/8 ma ±15 % 180 mcd 587 nm 10-2J19.1044 0.002 kg Single-LED green 6 VDC +10 % 7 ma ±15 % 1050 mcd 525 nm 10-2J06.3145 0.002 kg 12 VAC/DC +10 % 4/7 ma ±15 % 1050 mcd 525 nm 10-2J09.1065 0.002 kg 24 VAC/DC +10 % 4/7 ma ±15 % 1050 mcd 525 nm 10-2J12.1065 0.002 kg 28 VAC/DC +10 % 4/7 ma ±15 % 1050 mcd 525 nm 10-2J13.1065 0.002 kg 48 VAC/DC +10 % 2/4 ma ±15 % 600 mcd 525 nm 10-2J19.1045 0.002 kg Single-LED blue 6 VDC +10 % 15 ma ±15 % 680 mcd 470 nm 10-2J06.3146 0.002 kg 12 VAC/DC +10 % 7/14 ma ±15 % 650 mcd 470 nm 10-2J09.1066 0.002 kg 24 VAC/DC +10 % 7/14 ma ±15 % 650 mcd 470 nm 10-2J12.1066 0.002 kg 28 VAC/DC +10 % 7/14 ma ±15 % 650 mcd 470 nm 10-2J13.1066 0.002 kg 48 VAC/DC +10 % 4/8 ma ±15 % 400 mcd 470 nm 10-2J19.1046 0.002 kg 10

Accessories 41 LED colour Operating voltage Operation current Lumi. intensity Dom. wavelength Part No. Weight Single-LED white 6 VDC +10 % 15 ma ±15 % 750 mcd x0.31/y0.32 nm 10-2J06.3149 0.002 kg 12 VAC/DC +10 % 7/14 ma ±15 % 700 mcd x0.31/y0.32 nm 10-2J09.1069 0.002 kg 24 VAC/DC +10 % 7/14 ma ±15 % 700 mcd x0.31/y0.32 nm 10-2J12.1069 0.002 kg 28 VAC/DC +10 % 7/14 ma ±15 % 700 mcd x0.31/y0.32 nm 10-2J13.1069 0.002 kg 48 VAC/DC +10 % 4/8 ma ±15 % 400 mcd x0.31/y0.32 nm 10-2J19.1049 0.002 kg Filament lamp, T1 3/4 MG Order two filament lamps Operating voltage Operation current Part No. Weight Filament lamp 12 VAC/DC 75 ma±10 % 10-1309.1309 0.001 kg 14 VAC/DC 80 ma±10 % 10-1310.1319 0.001 kg 24 VAC/DC 35 ma±10 % 10-1312.1229 0.001 kg 28 VAC/DC 30 ma±10 % 10-1313.1209 0.001 kg 28 VAC/DC 40 ma±10 % 10-1313.1249 0.001 kg 36 VAC/DC 20 ma±10 % 10-1316.1179 0.001 kg 36 VAC/DC 30 ma±10 % 10-1316.1209 0.001 kg 48 VAC/DC 25 ma±10 % 10-1319.1199 0.001 kg Series resistor Additional Information Only for filament lamp 48 VAC, 25 ma For lamp voltage reduction Keep to the country specific safety instructions Due to high surface temperatures, the series resistor must not be soldered directly to the terminals of the equipment (use a terminal plate) Operating voltage Resistance Part No. Weight Series resistor 110 VAC 2.7 kohm 02-904.0 0.003 kg 125 VAC 3.3 kohm 02-904.1 0.003 kg 145 VAC 4.7 kohm 02-904.3 0.003 kg 240 VAC 10 kohm 02-904.7 0.003 kg 11

41 Accessories Terminal plate empty Product attribute Dimension Part No. Weight Terminal plate empty 5 spaces 62.5 x 60 x 15 mm 02-912.1 0.025 kg 10 spaces 125 x 60 x 15 mm 02-912.2 0.045 kg 15 spaces 187.6 x 60 x 15 mm 02-912.3 0.090 kg 20 spaces 250 x 60 x 15 mm 02-912.4 0.095 kg 12

Accessories 41 Mounting Lens remover Product attribute Part No. Weight Lens remover for raised design 02-905 0.011 kg Lamp remover Additional Information p Caution: A switching process might be released when replacing the lamp Part No. Weight Lamp remover 61-9740.0 0.003 kg Dismantling tool Part No. Weight Dismantling tool 41-939 0.027 kg 13

41 Drawings Drawings 18 5.08 2.54 24 M2 Ø1.0 (10x) 3.81 4 2 10 7.62 12.7 Ø2.1 hole for central mounting with M2 screw if desired 10.16 17.78 14

Technical data 41 Actuator with snap-action switching element Switching system Self-cleaning, double-break, snap action switching system (with contact gap 2 x 0.5 mm). 1 normally closed or 1 normally open contact per element. Up to 4 switching elements can be on a pushbutton (max. 4 normally closed and 4 normally open contacts). Material Material of contacts gold-plated silver Switching element Soldering terminal: PA 6.6 Ultramid Actuator case Polysulfone, heat-resistant and self-extinguishing Mechanical characteristics Connection method Snap-action switching element with tinned soldering terminals at the sides: max. wire diameter: 2 wires à 1.2 mm max. wire cross-section of stranded cable: 1x 1 mm 2 Actuating force 2-5.5 N, depending on the number of switching elements Actuating travel 3 mm Mechanical life Momentary action 2 million cycles of operation Maintained action 1 million cycles of operation Electrical characteristics Standards IEC 61058 EN 61 058 Rated voltage 250 VAC / VDC Rated current 5 A Volume resistance Starting value 50 mω Conventional free air thermal current l th 5 A The maximum current in continuous operation and at ambient temperature not exceeding the quoted maximum values. Switch rating 250 VAC / 5 A (cosφ 1) 250 VAC / 3 A (cosφ 0.3) Switch rating AC, cos φ 0.7: Voltage 125 V 250 V Current 3 A 2 A Switch rating DC (inductive), L:R = 30 ms Voltage 24 V 60 V 110 V 220 V Current 2 A 0.7 A 0.2 A 0.1 A Electric strength 2500 VAC, 50 Hz, 1 min. between all terminals and earth, as per IEC 60512-2-11 Protection class II Environmental conditions Storage temperature 40 C to +85 C Service temperature -25 C to +55 C for indicators and illuminated pushbuttons mounted as a block, make sure the heat can escape freely Degree of protection Front as per IEC 60529: IP 40 Resistance to shock (single impacts, semi-sinusoidal) 15 g for 11 ms as per IEC 60512-4-3, IEC 60068-2-27 Resistance to vibration (sinusoidal) 10 g at 0-2000 Hz, amplitude 1.5 mm as per IEC 60512-4-4, IEC 60068-2-6 Resistance to climate Standard condition as per IEC 60068-2-3 and 2-30 Changing condition as per IEC 60068-2-14 and 2-33 Approvals Approbations CB (IEC 61058) CSA UL Germanischer Lloyd Declaration of conformity CE 15

41 Technical data Actuator with Low Level switching element Switching system This low level switching element was designed for switching low powers in electronic circuits. The mechanism assures reliable switching of loads ranging from a few ma / mv up to 100 ma /42 VAC/VDC. Single-break momentary contact, as normally open or normally closed with 4 independent points of contact. 2 momentary contacts per switching element; combination of normally open and normally closed is possible. Special features are the long life, extremely short rebound time and stable contact resistance. Material Actuator case Polysulfone, heat-resistant and self-extinguishing Material of contacts gold-plated Switching element Polysulfone, heat-resistant and self-extinguishing Mechanical characteristics Connection method The universal terminals permit these units to be mounted on printed circuit boards (PCB). These terminals can also be used as soldering or plug-in terminals. For these terminals we can also supply a plug-in base which, when soldered on to the board, enables the switch to be plugged in. Soldering terminal max. wire diameter: 2 wires of 0.8 mm max. wire cross-section of stranded cable: 1 x 0.75 mm 2 Plug-in terminal 2.0 x 0.5 mm Actuating force 3-3.5 N Rebound time Typ. < 100 μs Mechanical life Momentary action 5 million cycles of operation Maintained action 1 million cycles of operation Electrical characteristics Volume resistance starting value 50 mω Switch rating 10 μa /100 μv to 100 μa at 42 VAC / VDC Electric strength 2500 VAC, 50 Hz, 1 min. between all terminals and earth, as per IEC 60512-2-11. Protection class II Environmental conditions Storage temperature 40 C to +85 C Service temperature -25 C to +55 C for indicators and illuminated pushbuttons mounted as a block, make sure the heat can escape freely Degree of protection Front as per IEC 60529: IP 40 Resistance to shock (single impacts, semi-sinusoidal) 15 g for 11 ms as per IEC 60512-4-3, IEC 60068-2-27 Resistance to climate Standard condition as per IEC 60068-2-3 and 2-30 Changing condition as per IEC 60068-2-14 and 2-33 Actuating travel 3 mm 16

General notes Marking 41 1. Engraving Typefaces In addition to the most commonly used world languages (see DIN 1451) with close spacing, the following typefaces are available: Scandinavian, Slavian, Greek, Russian. Coloured filling of engraving Specify whether engraving should be on the diffuser, or on the lens. Specify the infill colour, character height and the text or symbol orientation. Symbols A list of the symbols available can be supplied on request. 2. Hot stamping For large batches it is worth while to have the lettering produced by hot stamping. Symbols A list of the symbols available can be supplied on request. 3. Film inserts Instead of using engraving, the lenses can be fitted with transparent film inserts. For this purpose, though, it is advisable to use transparent lenses. To insert the film, the feet of the lens support have to be pushed together far enough to enable the lens to be lifted off easily. Film dimensions max. 12.7 x 18.7 mm (monocolour lens) max. 9 x 12.7 mm (two-colour lens) Film thickness 0.2 mm Important: Before engraving, check the position of the illuminated pushbuttons or indicator. Typefaces For letters and figures, typefaces with 2.5 mm, 3 mm and 4 mm are available. All dimensions in mm Height of letters h Thickness of letters s Number of lines Number of capital letters per line (target value) Number of small letters per line (target value) 2.5 0.4 4 11 12 B1 3 0.4 3 9 10 10 11 B1 4 0.5 2 7 7 8 B1 5 0.5 2 5 6 6 B1 6 0.6 1 4 5 5 B1 8 0.6 1 3 4 3 4 B1 2.5 0.4 5 7 8 8 B2 3 0.4 4 6 7 7 B2 4 0.5 3 4 5 5 B2 5 0.5 2 3 4 4 B2 6 0.6 2 3 3 4 B2 8 0.6 1 2 3 2 3 B2 2.5 0.4 4 5 6 5 6 B3 3 0.4 3 4 5 5 B3 4 0.5 2 3 3 4 B3 5 0.5 2 2 3 3 B3 6 0.6 1 2 2 3 B3 8 0.6 1 1 2 1 2 B3 2.5 0.4 2 7 8 8 B4 3 0.4 2 6 7 7 B4 4 0.5 1 4 5 5 B4 5 0.5 1 3 4 4 B4 6 0.6 1 3 3 4 B4 8 0.6 1 2 3 2 3 B4 B1 B2 B3 B4 Image Film AB abc AB abc h AB abc AB abc 17

41 Application guidelines Suppressor circuits When switching inductive loads such as relays, DC motors, and DC solenoids, it is always important to absorb surges (e. g. with a diode) to protect the contacts. When these inductive loads are switched off, a counter emf can severely damage switch contacts and greatly shorten lifetime. Fig. 1 shows an inductive load with a free-wheeling diode connected in parallel. This free-wheeling diode provides a path for the inductor current to flow when the current is interrupted by the switch. Without this free-wheeling diode, the voltage across the coil will be limited only by dielectric breakdown voltages of the circuit or parasitic elements of the coil. This voltage can be kilovolts in amplitude even when nominal circuit voltages are low (e. g. 12 VDC) see Fig. 2. The free-wheeling diode should be chosen so that the reverse breakdown voltage is greater than the voltage driving the inductive load. The DC blocking voltage (VR) of the free-wheeling diode can be found in the datasheet of a diode. The forward current should be equal or greater than the maximum current flowing through the load. To get an efficient protection, the free-wheeling diode must be connected as close as possible to the inductive load! Switching with inductive load Fig. 1 Counter EMF over load without free-wheeling diode Fig. 2 Switch ON OFF 0 VDC + _ Free-wheeling diode Inductive load Several hundred to several thousend volts e = L di dt 18

Index 41 Index from Part No. Part No. Page Part No. Page 02-904.0... 11 02-904.1... 11 02-904.3... 11 02-904.7... 11 02-905... 13 02-912.1... 12 02-912.2... 12 02-912.3... 12 02-912.4... 12 10-1309.1309... 11 10-1310.1319... 11 10-1312.1229... 11 10-1313.1209... 11 10-1313.1249... 11 10-1316.1179... 11 10-1316.1209... 11 10-1319.1199... 11 10-2J06.3142... 10 10-2J06.3144... 10 10-2J06.3145... 10 10-2J06.3146... 10 10-2J06.3149... 11 10-2J09.1062... 10 10-2J09.1064... 10 10-2J09.1065... 10 10-2J09.1066... 10 10-2J09.1069... 11 10-2J12.1062... 10 10-2J12.1064... 10 10-2J12.1065... 10 10-2J12.1066... 10 10-2J12.1069... 11 10-2J13.1062... 10 10-2J13.1064... 10 10-2J13.1065... 10 10-2J13.1066... 10 10-2J13.1069... 11 10-2J19.1042... 10 10-2J19.1044... 10 10-2J19.1045... 10 10-2J19.1046... 10 10-2J19.1049... 11 31-928... 9 31-945... 9 41-040.005... 4 41-041.006... 4 41-121.0252... 5 41-122.0252... 5 41-123.0252... 5 41-124.0252... 5 41-261.0252... 5 41-262.0252... 5 41-263.0252... 5 41-264.0252... 5 41-421.036... 5 41-422.036... 5 41-423.036... 5 41-461.036... 5 41-462.036... 5 41-463.036... 5 41-903.2... 7 41-903.3... 7 41-903.4... 7 41-903.5... 7 41-903.6... 7 41-903.7... 7 41-904.2... 7 41-904.3... 7 41-904.4... 7 41-904.5... 7 41-904.7... 7 41-907.2/3... 7 41-907.2/4... 7 41-907.2/5... 7 41-907.2/7... 7 41-907.3/5... 7 41-907.3/6... 7 41-907.3/7... 7 41-907.4/5... 7 41-907.4/6... 7 41-907.4/7... 7 41-907.5/6... 7 41-907.5/7... 7 41-907.7/7... 7 41-908.2/3... 7 41-908.2/5... 7 41-908.4/5... 7 41-908.7/7... 7 41-925... 8 41-939... 13 41-940... 9 41-947.0... 8 61-9740.0... 13 19