Project of RF System for 2.2 GeV Electron Storage Ring Zelenograd SR Source.

Similar documents
Tutorial on Design of RF system for Indus Accelerator. Maherdra Lad Head, Radio Frequency Systems Division RRCAT, Indore

MAX II RF system 100 MHz technology Lars Malmgren 10th ESLS RF Meeting Dortmund September 27-28, 2006

1997 Particle Accelerator Conference, Vancouver, B.C., Canada, May 12-16, 1997 BNL

Detailed Design Report

Jørgen S. Nielsen Institute for Storage Ring Facilities, Aarhus, University of Aarhus Denmark

Resonator System for the BEST 70MeV Cyclotron

Design and performance of LLRF system for CSNS/RCS *

10th ESLS RF Meeting September ALBA RF System. F. Perez. on behalf of the ALBA RF Group. ALBA RF System 1/21

Low-Level RF. S. Simrock, DESY. MAC mtg, May 05 Stefan Simrock DESY

Calibrating the Cavity Voltage. Presentation of an idea

Acceleration of High-Intensity Protons in the J-PARC Synchrotrons. KEK/J-PARC M. Yoshii

Normal-conducting high-gradient rf systems

Main Injector Cavity Simulation and Optimization for Project X

2008 JINST 3 S The RF systems and beam feedback. Chapter Introduction

ALICE SRF SYSTEM COMMISSIONING EXPERIENCE A. Wheelhouse ASTeC, STFC Daresbury Laboratory

Experiment-4 Study of the characteristics of the Klystron tube

Superconducting RF System. Heung-Sik Kang

MG7095 Tunable S-Band Magnetron

Lawrence Berkeley Laboratory UNIVERSITY OF CALIFORNIA

S-band Magnetron. Tuner revolutions to cover frequency range 4.75 (note 3) Mounting position (note 4) Any Cooling (note 5) Water

REVIEW ON SUPERCONDUCTING RF GUNS

Automatic phase calibration for RF cavities using beam-loading signals. Jonathan Edelen LLRF 2017 Workshop (Barcelona) 18 Oct 2017

Project X Cavity RF and mechanical design. T. Khabiboulline, FNAL/TD/SRF

Abridged Data. General Data. MG7095 Tunable S-Band Magnetron for Switched Energy Applications. Cooling. Electrical. Accessories.

Available online at ScienceDirect. Physics Procedia 84 (2016 )

X band Magnetron. Water: Anode cavity Forced-air: Input ceramics and terminals Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent

Harald Klingbeil GSI Helmholtzzentrum für Schwerionenforschung GmbH. Contents

Maurizio Vretenar Linac4 Project Leader EuCARD-2 Coordinator

REVIEW OF HIGH POWER CW COUPLERS FOR SC CAVITIES. S. Belomestnykh

Summary LOI Developments

Predictions of LER-HER limits

Booster High-level RF Frequency Tracking Improvement Via the Bias-Curve Optimization

1.5 GHz Cavity design for the Clic Damping Ring and as Active Third Harmonic cavity for ALBA.

X-band Magnetron. Cooling (note 5) Water Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent

A Synchrotron Phase Detector for the Fermilab Booster

JUAS 2018 LINACS. Jean-Baptiste Lallement, Veliko Dimov BE/ABP CERN.

New apparatus for precise synchronous phase shift measurements in storage rings 1

R.Bachimanchi, IPAC, May 2015, Richmond, VA

CEBAF Overview June 4, 2010

FAST RF KICKER DESIGN

MG5193 Tunable S-Band Magnetron

C100 Cryomodule. Seven cell Cavity, 0.7 m long (high Q L ) 8 Cavities per Cryomodule Fits the existing Cryomodule footprint

Beam Infrared Detection with Resolution in Time

Grounding for EMC at the European XFEL

Coupler Electromagnetic Design

RF design studies of 1300 MHz CW buncher for European X-FEL. Shankar Lal PITZ DESY-Zeuthen

R.K.YADAV. 2. Explain with suitable sketch the operation of two-cavity Klystron amplifier. explain the concept of velocity and current modulations.

Conceptual Design of a Table-top Terahertz Free-electron Laser

MEASURES TO REDUCE THE IMPEDANCE OF PARASITIC RESONANT MODES IN THE DAΦNE VACUUM CHAMBER

Does the short pulse mode need energy recovery?

ERL based FELs. Todd I Smith Hansen Experimental Physics Laboratories (HEPL) Stanford University Stanford, CA

Performance of the Reference and Timing Systems at SPring-8

Beam Diagnostics, Low Level RF and Feedback for Room Temperature FELs. Josef Frisch Pohang, March 14, 2011

J. Jacob: Status of the ESRF RF upgrade

CHAPTER 6 BOOSTER RF SYSTEMS

MICROWAVE MICROWAVE TRAINING BENCH COMPONENT SPECIFICATIONS:

Physics Requirements Document Document Title: SCRF 1.3 GHz Cryomodule Document Number: LCLSII-4.1-PR-0146-R0 Page 1 of 7

Commissioning of the ALICE SRF Systems at Daresbury Laboratory Alan Wheelhouse, ASTeC, STFC Daresbury Laboratory ESLS RF 1 st 2 nd October 2008

Jørgen S. Nielsen Center for Storage Ring Facilities (ISA) Aarhus University Denmark. ESLS-RF 22 (8/ ), ASTRID2 RF system 1

(i) Determine the admittance parameters of the network of Fig 1 (f) and draw its - equivalent circuit.

Bunch-by-Bunch Broadband Feedback for the ESRF

RF Design of Normal Conducting Deflecting Cavity

Thermionic Bunched Electron Sources for High-Energy Electron Cooling

MICROWAVE AND RADAR LAB (EE-322-F) LAB MANUAL VI SEMESTER

M5028 Precision Tuned Magnetron

EC 1402 Microwave Engineering

FLASH at DESY. FLASH. Free-Electron Laser in Hamburg. The first soft X-ray FEL operating two undulator beamlines simultaneously

ERLP Status. Mike Dykes

LOI Progress Report -- Summary of Experiment in January

Third Harmonic Superconducting passive cavities in ELETTRA and SLS

MG6090 Tunable S-Band Magnetron

Stability Analysis of C-band 500-kW Klystron with Multi-cell. Output cavity

The HPRF system for a new 6 GeV synchrotron light source in Beijing

Chapter 6 Antenna Basics. Dipoles, Ground-planes, and Wires Directional Antennas Feed Lines

Introduction to Synchrotron Radio Frequency System

LHC TRANSVERSE FEEDBACK SYSTEM: FIRST RESULTS OF COMMISSIONING. V.M. Zhabitsky XXI Russian Particle Accelerator Conference

CST MWS simulation of the SARAF RFQ 1.5 MeV/nucleon proton/deuteron accelerator

The BESSY Higher Order Mode Damped Cavity - Further Improvements -

4X150A/7034 Radial Beam Power Tetrode

Motivation: ERL based e linac for LHeC

MG5223F S-Band Magnetron

Prospects for an Inductive Output Tube (IOT) Based Source

QUESTION BANK SUB. NAME: RF & MICROWAVE ENGINEERING SUB. CODE: EC 2403 BRANCH/YEAR/: ECE/IV UNIT 1 TWO PORT RF NETWORKS- CIRCUIT REPRESENTATION

Re-commissioning the Recycler Storage Ring at Fermilab

The European Spallation Source. Dave McGinnis Chief Engineer ESS\Accelerator Division IVEC 2013

FLASH Operation at DESY From a Test Accelerator to a User Facility

Breakdown in Waveguides and Components

Dhanalakshmi College of Engineering Department of ECE EC6701 RF and Microwave Engineering Unit 4 Part A

Advance on High Power Couplers for SC Accelerators

RF Upgrade at DELTA. P. Hartmann DELTA, TU Dortmund

Input Return Loss, db > 26 Narrowband to Narrowband Isolation, db > 30

LLRF Operation and Performance of the European XFEL. An overview

Circumference 187 m (bending radius = 8.66 m)

Accelerator Complex U70 of IHEP-Protvino: Status and Upgrade Plans

INSTALLATION AND FIRST COMMISSIONING OF THE LLRF SYSTEM

VEPP-2000 COLLIDER CONTROL SYSTEM*

The Australian Synchrotron. Crowbar Less High Voltage Power Supplies (HVPS) 7th ESLS RF meeting, Oct Karl Zingre RF Engineer

Borut Baricevic. Libera LLRF. 17 September 2009

RF Cavity Design. Erk Jensen CERN BE/RF. CERN Accelerator School Accelerator Physics (Intermediate level) Darmstadt 2009

Short-Pulse X-ray at the Advanced Photon Source Overview

Transcription:

Project of RF System for 2.2 GeV Electron Storage Ring Zelenograd SR Source. I.K. Sedlyarov V.S. Arbuzov, E.I Gorniker, A.A. Kondakov, S.A. Krutikhin, G.Ya. Kurkin, I.V.Kuptsov, V.N. Osipov, V.M. Petrov, A.V.Philipchenko, A.M. Pilan, A.G. Tribendis, V.A. Ushakov. Budker Institute of Nuclear Physics SB RAS, Lavrentiev 11, 630090 Novosibirsk, Russia.

New electron storage ring designed at BINP SB RAS is being built in Zelenograd, Russia as dedicated technological synchrotron radiation (SR) source. This machine will provide SR in the range of 0.1 2000 Å. Maximum electron beam energy SR energy loss at this energy - Energy loss due to insertion devices - 2.2 GeV. 409 kev per turn. + 105 kev. In single bunch mode average beam current -0.1 A In multi-bunch mode average beam current - 0.3 A.

RF system consists of: 1. Two bi-metal cavities. The cavities are placed in the storage ring at a distance between their centers of half-wavelength. 2. Single generator with CW output power of 300 kw. 3.One waveguide (986mm 150mm). The generator and the cavities are connected to the waveguide through waveguide-to-coaxial transitions. 4.Accelerating voltage and phase are controlled by control subsystem. Main parameter of the RF system are listed in table 1.

Table 1: Parameters of the storage ring RF system Operating frequency 181.33 MHz Harmonic number 70 Number of cavities 2 Total accelerating voltage Cavity frequency tuning range Gap voltage U (ampl.) per cavity 0.2 1 MV ±180 khz 0.1 0.6 MV Transit time factor 0.9 Cavity quality factor 39000 Cavity shunt impedance R= U²/2P Power loss per cavity at U max Generator output power 5.2 MOhm 35 kw 300 kw

Bi-metallic cavity of Novosibirsk FEL injector analogous to the cavity of Zelenograd storage ring.

Schematic view of accelerating bimetallic cavity

2 contactless fundamental mode tuners 2 higher order modes tuners Coaxial power coupler Inductive probe

Coaxial power coupler (side-view)

V fil Test tube T H 781 Regime CW, testing Frequency of 176 MHz RF output power of 150 kw I fil V anode V screen grid V contro l grid I anode P rf inpu t P anode dissipatio n V A kv V V A kw kw 9.5 330 10 1200-350 22 7 77 Calculated Regime CW, Performance for TNK Frequency of 181 MHz RF output power of 150 kw V fil I fil V anode V screen grid V contr ol grid I anode P rf input P anode dissipatio n V A kv V V A kw kw 9.5 330 9 1200-350 25 9 84

View from above to the output stage of RF generator of Siberia-2 storage ring in Moskow, which design is analogous to one of Zelenograd.

Scheme of RF feeder between the waveguide and one of the cavities. 1- waveguide, 2- waveguide-to-coaxial transition, 3-coaxial feeder of 75 Ohm, 4-directional couplers, 5- current pick-up loops, 6- quarter wavelength transformer, 7- cavity.

View of feeders between the waveguide and two cavities of Siberia-2 storage ring, which design is analogous to Zelenograd The cavities are driven in anti-phase due to proper rotation of the coupler Loops. Both feeders are connected to the waveguide at the same cross-section symmetrically relative to the middle of its wide wall. The distance between the waveguide and the cavities is multiple odd number of quarter wavelengths.

Control sub-system Control sub-system has feedback loops for adjustment and stabilization of the total accelerating voltage. Time constant of 100µs. Control sub-system has feedback loop for resonant frequency tuning. Time constant of 0,1s. The total accelerating voltage is phased by the storage ring master oscillator signal at 181,33 MHz. Also the RF voltage of the injector is phased by the same master oscillator which ensures precise synchronization of the Injection to the storage ring. Control sub-system has an interlock board that protects the equipment and personnel in case of failure.

Conclusion RF system that allows obtaining the design parameters of the technological electron storage ring -SR source has been developed. The design work is being completed. A new RF generator had been developed using Thales tetrode TH781 Parts of the RF system are in production at the moment. After assembling and testing at BINP the 2 cavities and generator will sent to Zelenograd. Commissioning of the RF system is scheduled for the 1st half of 2009.