Digital Clamp Meter (TRMS) Model : 2727

Similar documents
DIGITAL CLAMP ON METER MODEL : 3600

Accuracy : ± (0.8% rdg + 1dgt) on all ranges except Ranges : 200mV, 2V, 20V, 200V, 1000V

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

AC/DC CLAMP METER USER S MANUAL

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

NOTE: Fully read and understand this manual before using this Digital Multimeter.

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

OPERATING INSTRUCTION

User s Guide. 400A AC/DC Clamp Meter. Model MA220

ET-3888 True RMS Clamp Meter. User Manual

OPERATOR S INSTRUCTION MANUAL

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL- KM 2782 / 2782-T

M-1000D DIGITAL MULTIMETER

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

AMM-1022 Digital Multimeter USER`S MANUAL

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

400Amp True RMS AC Clamp Meter + NCV

User s Guide. Digital AC/DC Clamp Meter Model 38394

Pen-type DIGITAL MULTITESTER

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

DVM1190 DIGITAL MULTIMETER

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

User Guide. Digital AC/DC Clamp Meter Model 38394

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

USER'S MANUAL DMR-6700

HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

UT207A/208A/209A Operating Manual. Table of Contents

200Amp AC Clamp Meter + NCV Model MA250

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

DMM8900 SERIES USERS MANUAL

CONTENTS MS2033A. 1.Introduction Safety Information...01

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

MS2030 CAT III 600 V A V AUTO RS232

400Amp True RMS AC/DC Clamp Meter Model EX613

INSTRUCTION MANUAL DIGITAL MULTIMETER

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

PCMT20 PYLE C;",D J WWWPYLEAUDIO.COM

OPERATOR S INSTRUCTION MANUAL

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.

Sales: Technical: Fax:

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

MW3105 DIGITAL CLAMP MULTIMETER

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

312, 316, 318. Clamp Meter. Users Manual

KMD-S04 Multímetro de bolsillo

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

Digital Clamp Meter Model: &

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

MS8216 DIGITAL MULTIMETER OPERATOR S MANUAL

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

1.General instructions Specifications Description...7

Autoranging Multimeter Extech EX503

2000 A AC TRUE RMS DIGITAL CLAMP METER WITH NON-CONTACT EF-DETECTION

R/C SMD Tweezers Multimeter Model RC200

DIGITAL CLAMP METER Use s Manual

Multifunction Digital

Not for Reproduction

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

600A Clamp Meters w/tightsight Display

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

Model UT10A: OPERATING MANUAL Table of Contents (1)

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

USER'S MANUAL DMR-4300

Model DIGITAL MULTIMETER

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

USER'S MANUAL TBM061 TBM062 TBM063 TBM065

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

MODEL: D03128 CLAMP METER

USER S MANUAL DMR-1500

DM-46 Instruction Manual

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

Table of Contents Title Page

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

DIGITAL CLAMPMETER MODEL

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

User Manual Digital Multimeter. model no.: MSR-U1000

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

True RMS Digital Multimeter Model:

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

79/26 Series III Multimeter

DM-46 Instruction Manual

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

USER'S MANUAL DMR-4350

User Manual Digital Clamp Multimeter. model no.: MSR-C600

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

INSTRUCTION MANUAL IDM17 PEN-TYPE MULTIMETER

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

AUTO RANGING DIGITAL MULTIMETER

Transcription:

Digital Clamp Meter (TRMS) Model : 2727 Instruction Manual 1. SPECIFICATIONS 1.1 General Specifications Display : 3 ¾ digit liquid crystal display (LCD) with a maximum reading of 3999. Polarity : Automatic, positive implied, negative polarity indication. Overrange : (OL) or (-OL) is displayed. Zero : Automatic. Low battery indication : (+ -) is displayed when the battery voltage drops below the operating level. Measurement rate : 2.5 times per second, nominal. Operating Environment :0 0 C to 50 0 C at < 70% relative humidity. Storage Temperature : -20 0 C to 60 0 C, 0 to 80% R.H. with battery removed from meter. : Stated accuracy at 27 0 C ± 5 0 C, <75% relative humidity. Power : Single standard 9 Volt battery EVEREADY TYPE 216 or Equivalent. Battery life : 200 hours typical with carbon-zinc. Dimension 2727 : 192mm(H)x82mm(W)x33mm(D). Weight 2727 : 270grams approx. Accessories : One K type thermocouple, one pair of test leads 9V battery (installed), instruction manual. Maximum Jaw Opening : 2727 : 30mm. 1 2 1.2 Electrical Specifications AC CURRENT (True RMS) Overload Protection 40A 50/60Hz ± (2%rdg+4dgt) 1000A 40-500Hz ± (3.5%rdg+5dgt) ac max. 400A/600A (2727) 40-500Hz ± (3.5%rdg+5dgt) for 1 min. AC VOLTS (True RMS) (50 Hz - 500Hz) Input lmpedance DC VOLTS Input lmpedance RESISTANCE Open circuit voltage 400V,750V 100mV ± (2.9%rdg+4dgts) 10MV 1000V DC or 750V AC rms 1000V 1V ± (1.5%rdg+1dgt) 10MV 1000V DC or 750V AC rms 400V, 400KV 100mV ± (1.5%rdg+3dgt) 0.6V DC (3.0V DC on 400V range) 500V DC or AC rms DIODE TEST Test Current Open circuit volts FREQUENCY (Autoranging) s Overload Protection TEMPERATURE s CONTINUITY Audible indication 1.0mA ± 0.6mA ± (3%rdg + 3dgt) 3.0V DC typical 500V DC or AC rms 4kHz - 40kHz ± (1%rdg+2dgt) 100V rms min 500V DC or AC rms (50Hz-1KHz) - 20 0 C ~ 750 0 C 1 0 C ± (2.0% rdg + 3 dgts ) on -20 0 C ~ 500 0 C ± (3.0% rdg + 2 dgts ) on 500 0 C ~ 750 0 C less than 100V 500V DC or AC rms 3 4

2. OPERATION Before taking any measurements, read the safety information section Always examine the instrument for damage, contamination (excessive dirt, grease, ect.) and defects. Examine the test leads for cracked or trayed insulation. If any abnormal conditions exist do not make any measurements. MAX. DATA HOLD SWITCH The push switch (push Latch, Push Release) will hold the maximum reading on the display. The display will update if a higher value is measured. A p will appear in the display when this feature is enabled. 2.1 Current Measurements 1. Set the Function/ switch on the highest 600A AC range. 2. Press the trigger to open transformer jaws and clamp onto one conductor only. Read the current directly on the display. It is recommenced that the conductor be placed at the center of the closed jaws for maximum accuracy. 3. When the reading is lower than 400 counts, set the range switch to the next lower range position. For maximum accuracy, select the lower range possible without over ranging the meter. 2.2 Voltage Measurements 1. Connect the red test lead to the VV jack and the black test lead to the COM jack. 2. Set the Function/ switch to the desired Voltage type (AC or DC) and range. If magnitude of voltage is not known, set switch to the highest range and reduce until a satisfactory reading is obtained. 3. Connect the test leads to the device or circuit being measured. 4. For DC, a (-) sign is displayed for negative polarity; positive polarity is implied. 2.3 Frequency Measurements 1. Set the Function/ switch to the Hz position. 2. Connect the red test to the VV jack and the black test lead to the COM jack. 3. Connect the test leads ro the point of measurements and read the frequency from the display. 2.4 Temperature Measurements WARNING : Remove test leads before measuring temperature 1. Set the Function/ switch to the 0 C position. 2. Connect a k type thermocouple to the jack on the instrument. Place the probe or thermocouple tip on or in the material to be measured and take the temperature reading directly from the display. 2.5 Diode Test 1. Connect the red test lead to the VV jack and black test lead 1o the COM jack. 2. Set the Function/r switch to the diode position. 3. Turn off power to the circuit under test. 4. Touch probes to the diode. A forward-voltags drop is about 0.6V (typical for a silicon diode.) 5. Reverse probes It the diode is good, display will be between 2.800V and 3.200V. If the diode is shorted,.000 or another number is displayed. 6. If the diode is open, display will be between 2.800V and 3.200V, in both directions. 7. If the diode is measured in a circuit and a low reading is obtained with both lead connections, the diode may be shunted by a resistance of less than 1kV. In this case the diode must be disconnected from the circuit for accurate tasting 2.6 Resistance and Continuity Measurements 1. Set the Function/ switch to the desired resistance range or continuity position. 2. Disconnect power from the equipment under test. 3. Connect the red test lead to the VV jack and the black test lead to the COM jack. 4. Touch the probes to the test points. In ohms, the value indicated in the display is the measured value of resistance. In continuity test, the beeper sounds continuously if the resistance is less than 100V. 5 6 3. MAINTENANCE WARNING Remove test leads before changing battery or performing any servicing. Battery Replacement Power is supplied by a 9 volt transistor battery EVEREADY TYPE 216 or Equivalent. The (+ -) appears on the LCD display when replacement is needed To replace the battery, remove the screw from the meter and lift off the battery cover Remove the battery from battery contacts and replace cover. 4. SAFETY INFORMATION CERTIFICATE OF CALIBRATION We hereby certify that this product has been calibrated and found to be in accordance with the applicable SPECIFICATIONS and MECO STANDARDS. Accuracies of the standard equipment used in this calibration are traceable to the National Standards. The following safety information must be observed to ensure maximum personal safety during the operation of this meter : 1. Do not use the meter if the meter or test leads lock damaged, or if you suspect that the meter is not operating properly. 2. This clamp meter is designed to take current measurements on circuit with a maximum voltage difference of 500VAC between any conductor and ground potential. Using the instrument for current measurements on circuit above this voltage may cause electric shock, instrument damage or damage lo the equipment under test. 3. Turn off power to the circuit under test before cutting, unsoldering, or breaking the circuit Small amounts of current can be dangerous. 4. Use caution when working above 60V DC or 30V AC rms. Such voltages pose a shock hazard. 5. When using the probes, keep your fingers behind the finger guards on the probes. 6. Measuring voltage which exceeds the limits of the clamp meter may damage the meter and expose the operator to a shock hazard. Always recognize the meter voltage limits as stated on the meter. MECO METERS PVT. LTD. Block 9, Plot 270, 2nd Floor, Rup-Udey Niwas, Sion (E), Mumbai - 400 022 (INDIA) Correspondance Address : Plot No. EL-1, MIDC Electronic Zone, TTC Industrial Area, Mahape, Navi Mumbai - 400710 (INDIA) Tel : 0091-22-27673311-16, 27673300 (Board) Fax : 0091-22-27673310, 27673330 E-mail : sales@mecoinst.com Web : www.mecoinst.com SR. NO CHECKED BY : : 7 8 DATE MODEL NO : :

1 DIGITAL CLAMP METER MODEL : 2025-Hz TRMS INSTRUCTION MANUAL 1. SPECIFICATIONS 1.1 General Specification Display n 3¾ digit liquid crystal display (LCD) with a maximum reading of 3999. Polarity n Automatic, positive implied, negative polarity indication. Overrange n (OL) or (-OL) is displayed. Zero n Automatic. Low battery n is displayed when the battery indication voltage drops below the operating level. Measurement n 3 times per second, nominal. rate Operating n 0 C to 50 C at < 70% relative humidity. Environment Storage n -20 C to 60 C, 0 to 80% R.H. with battery Temperature removed from meter. Power n Two 1.5V AAA Size Battery Battery life n 200 hours typical Dimensions n 250mm X 98mm X 35mm Weight n 400 grams approx. Accessories n One pair of test leads, instruction manual, 1.5V batterys (installed), Carring Case, Maximum Jaw n 55mm Opening 2 1.2 Electrical Specification Accuracies are ± (% reading + number of digits) at 27 ± 5 C and humidity of less than 75% RH. AC CURRENT (True RMS) Overload Protection 40A 50-60Hz ±(3% rdg+ 6dgt) 1000A AC Max. 400A / 1000A 40-500Hz ±(3.5% rdg+ 5dgt) for 1 minute DC VOLTAGE (Auto Ranging) s : 4V, 40V, 400V, 1000V : ± (1% of rdg + 2 dgt) : 1mV to 1V Input Impedance : 10MV on all ranges except, 11MV on 4V Overload Protection : 1200V DC/800V AC AC VOLTAGE (Auto Ranging) 40-500Hz : 4V, 40V, 400V, 750V : ± (1.5% rdg + 6 dgt) : 1mV to 1V Input Impedance : 10MV on all ranges except, 11MV on 4V Overload Protection : 1200V DC/800V AC RESISTANCE (Auto Ranging) : 400V, 4KV, 40KV, 400KV, 4MV, 40MV : ± (2.5% of rdg + 3 dgt) Test Current Overload Protection Continuity Check Threshold Level Response Time Open Circuit Voltage : 0.1V to 0.01MV : 0.7mA on 400V, 0.1mA on 4KV, 30µA on 40KV, 4µA on 400KV : 500V DC/AC : 40V Approx. : 1m Sec. Approx. : 0.4V Approx. Indication : is displayed on LCD and buzzer sounds at continuity. Overload Protection : 500V DC / AC Diode Test Measurement Current : 1.0 ± 0.6 ma Approx. Open Circuit Voltage : 0.4V Approx. Overload Protection : 500V DC / AC Frequency (Auto Ranging) : 10.00Hz, 50.00Hz, 500.0Hz, 5.000kHz, 50.00kHz, 500.0kHz : ± (0.5% rdg + 5 dgt) : 3V Overvoltage Protection : 200V DC or AC peak % Duty Cycle (Auto Ranging) : 1% to 90% : ± (0.5% rdg + 5 dgt) : 0.1% Overvoltage Protection : 200V DC or AC peak 3 4

2. OPERATION Before taking any measurements, read the safety information section. Always examine the instrument for damage, contamination (excessive dirt, grease, etc.) and defects. Examine the test leads for cracked or frayed insulation. If any abnormal conditions exist do not attempt to make any measurements. SELECT BUTTON In ACV it will select ACV / Hz/Duty function. In V/ / range it will select resistance or diode or countinuity function. In Hz it will select Hz/Duty function. DATA HOLD BUTTON Press Data Hold button to toggle in and out of Data Hold mode, In the Data Hold mode, the HOLD annunciator is displayed. 2.1 Current Measurements 1. Set the Function / switch to the highest 1000A AC range. 2. Press the trigger to open transformer jaws, clamp onto one conductor only and release trigger. Jaws should be completely closed. Read the current directly on the display. It is recommended that the conductor be placed at th e center of the closed jaws for maximum accuracy (Fig. - 1). Fig. 1 7 3 3. When the reading is lower than 400 counts, set the range switch to the next lower range position. For maximum accuracy, select the lowest range possible without over 5 ranging the meter. 2.2 Voltage Measurements 1. Connect the red test lead to the VV jack and the black test lead to the COM jack. 2. Set the Function/ switch to the desired Voltage type (AC or DC) 3. Connect the test leads to the device or circuit being measured. 4. For DC, a (-) sign is displayed for negative polarity; positive polarity is implied. 2.3 Resistance Measurements 1. Connect red test lead to the VV jack and black test lead to the COM jack. 2. Set function / switch to V/ / position. 3. If the resistance being measured is connected to a circuit, turn off power to the circuit being tested and discharge all capacitors. 4. Connect test leads across the resistance being measured. When measuring high resistance, be sure not to contact adjacent points even if insulated because some insulators have a relatively low insulation resistance, causing the measured resistance to be lower than the actual resistance. 5. Read resistance value on digital display. If a high resistance vaiue is shunted by a large value of capacitance allow display to stabilize. 2.4 Diode Test 1. Connect the red test lead to the VV jack and black test lead to the COM jack. 2. Set the Function / switch to the V/ / position, select by pressing select key. 3. Turn off power to the circuit under test. 6 4. Touch probes to the diode. A forward-voltage drop is about 0.6V (typical for a silicon diode). 5. If the digital display reads overrange OL, reverse the lead connections. The placement of the test leads when the forward reading is displayed indicates the orientation of the diode. The red lead is positive and the black lead is negative. If overrange OL is displayed with both lead connections, the junction is open. If a low reading (less than 1000) is obtained with both lead connections, the junction is shorted internally or (if junction is measured in a circuit) the junction is shunted by a resistance less than 1KV. In the letter case the junction must be disconnected from the circuit in order to verify its operartion. 2.5 Continuity Measurement In continuity test, the beeper sounds continuously, if the resistance is less than 40V. 2.6 Frequency & Duty Cycle Measurement There are 2 positions for Frequency & Duty cycle measurements. a) Hz position (Not for line frequency measurement.) b) ACV position. (for line frequency measurement) 2.6a Hz position (Not for line frequency measurement.) : 3V Frequency : 10Hz to 500kHz Duty Cycle : 1% to 90% Overvoltage Protection : 200V DC or AC peak 1. Connect test lead to VV and COM terminal. 2. Set rotary switch to Hz posotion. 3. Select Frequency or Duty cycle by pressing Select key. 4. Connect the test leads across the source or load under measurement. 2.6b ACV position (For line frequency measurement.) : 2V Frequency : 40Hz to 500Hz Duty Cycle : 10% to 90% Overvoltage Protection : 1000V DC or 750V AC peak 1. Connect test lead to VV and COM terminal. 2. Set rotary switch to ACV posotion. 3. Select Frequency or Duty cycle by pressing Select key. 4. Connect the test leads across the source or load under measurement. 3. MAINTENANCE WARNING Remove test leads before changing battery or servicing. Battery Replacement Power is supplied by two 1.5V AAA size battery or Equivalent. The appears on the LCD display when replacement is needed. To replace the battery, remove the screw from the battery cover and lift off the battery case. Remove the batterys & repleced with new batterys. 4. SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: 1. Do not use the meter if the meter or test leads look damaged, or if you suspect that the meter is not operating properly. 2. This Clamp Meter is designed to take current measurements on circuits with a maximum voltage difference of 500VAC between any conductor and ground potential. Using the instrument for current measurements on circuits above this voltage may cause electric shock, instrument damage or damage to the equipment under test. 7 8

Before measuring current make certain the test leads are removed from the instrument. 3. The instrument is protected for overload upto 500 VAC for 1 minute. Do not take current readings on circuits where the maximum current potential is not known. Do not exceed the maximum currents that this instrument is designed to measure. 4. Turn off power to the circuit under test before cutting, unsoldering, or breaking the circuit. Small amounts of current can be dangerous. 5. Use caution when working above 60V DC or 30V AC rms. Such voltages pose a shock hazard. 6. When using the probes, keep your fingers behind the finger guards on the probes. 7. Measuring voltage which exceeds the limits of the clamp meter may damage the meter and expose the operator to a shock hazard. Always recognize the meter voltage limits as stated on the front of the meter. N O T E 9 10 N O T E CERTIFICATE OF CALIBRATION We hereby certify that this product has been calibrated and found to be in accordance with the applicable SPECIFICATIONS and MECO STANDARDS. Accuracies of the standard equipment used in this calibration are traceable to the National Standards. MECO METERS PVT. LTD. Block 9, Plot 270, 2nd Floor, Rup-Udey Niwas, Sion (E), Mumbai - 400 022 (INDIA) Correspondance Address : Plot No. EL-1, MIDC Electronic Zone, TTC Industrial Area, Mahape, Navi Mumbai - 400710 (INDIA) Tel : 0091-22-27673311-16, 27673300 (Board) Fax : 0091-22-27673310, 27673330 E-mail : sales@mecoinst.com Web : www.mecoinst.com SR. NO CHECKED BY : : DATE : 11 MODEL NO : 12

SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation at this meter: 1. Do not use the meter if the meter or test leads look damaged, or if you suspect that the meter is not operating properly. 2. Use caution when working above 60V dc or 30V ac rms. Such voltages pose a shock hazard. 3. When Using the probes, keep your fingers behind the finger guards on the probes. 4. Measuring voltage which exceeds the limits of the clamp meter may damage the meter and expose the operator to a shock hazard. Always recognize the meter voltage limits as stated on the front of the meter. 5. If the equipment is used in a manner not specified by the manufacturer, the protection provided the equipment may be impaired. DIGITAL CLAMP ON METER MODEL : 3636 USER MANUAL 1 2 SPECIFICATIONS Display : 3½ digit liquid crystal display (LCD) with a maximum reading of 1999. Polarlty : Automatic, positive implied, negative polarity indication. Overrange : (OL) or (-OL) is displayed. Zero : Automatic. Low battery indlcation : the is displayed when the battery voltage drops below the operating level. Measurement rate : 2.5 times per second, nominal. Operating Environment : 0 0 C to 40 0 C at < 70% relative humidity. Storage Temperature : -20 0 C to 60 0 C, 0 to 80% R.H. with battery removed from meter. : Stated accuracy at 23 0 C ± 5 0 C, <75% relative humidity. Safety : According to EN61010-1 protection class II overvoltage category (CAT III 600V) pollution degree 2. Clamp jaw : According ro EN61010-2-032 CAT IV 600V. Power : single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22. Battery life : 200 hours typical with carbon-zinc, Dimensions : 250mm (H) x 100mm (W) x 46mm (D). Weight : Approx. 380g including battery. Accessories : One pair test leads, 9V battery (installed). DC VOLTS s : 600V : ±(0.5% rdg + 1dgt) Input Impedance : 10MV AC VOLTS (True RMS) (50Hz - 500Hz) s : 200V, 600V : ±(1.2% rdg + 10dgts) Input Impedance : 10MV Overload protectlon : 600VDC or AC rms RESISTANCE a : 2KV, 200KV : ±(1.2% rdg + 1dgt) Open circuit volts : 0. 3Vdc FREQUENCY (Autoranging) s : 2KHz, 20KHz : ±(0.1% rdg + 3dgts) on all ranges : 80Vrms min CONTINUITY Audible lndication : less than 30V on 2KV range 3 4

DIODE TEST Test current : 1.0mA ± 0.6mA : ±(6.0% rdg + 3dgts) Open circuit volts : 3.0Vdc typical Audible Indication : < 30mV AC CURRENT (True RMS) (Put conductor at the center of the jaws) s : 20A, 200A, 1000A : ±(1.5%rdg + 10dgts) on all ranges (50Hz/60Hz) ±(3.5%rdg + 10dgts) on 700A(40Hz/500Hz) ±(2.0%rdg+ 10dgts) on700a to 1000A(50Hz/60Hz) : 1000Aac max. for 1 minute OPERATION Before taking any measurements, read the Safety Information Section. Always examine the instrument for damage, contamination (excessive dirt, grease, etc.) and defects. Examine the test leads for cracked or frayed insulation. If any abnarmal conditions exist do not attempt to make any measurements. H Button : Press H button to toggle in and out of DATA Hold mode, In the DATA Hold mode, the H annunciator is displayed. (The DATA Hold mode may be exited when changing function.) 5 MAX HOLD Button : Press MAX button to toggle in and out of MAX Hold mode (holding the highest absolute reading). In the MAX Hold mode, the MAX annunciator is displayed. Current and Hz ranges without MAX HOLD function. PEAK HOLD Button : (only current ranges 40-60Hz) Press PEAK button to toggle in and out of PEAK Hold mode. In the PEAK Hold mode, the P annunciator is displayed. { : ± [10% (readind -residual offset) + 10dgts], effect reading : 80~2000} Voltage Measurements 1. Connect the red test lead to the V jack and the black test lead to the COM jack. 2. Set the Function/ switch to the desired Voltage type (AC or DC) and range. If magnitude of voltage is not known, set switch to the highest range and reduce until a satisfactory reading is obtained. 3. Connect the test leads to the device or circuit being measured. 4. For dc, a (-) sign is displayed for negative polarity, positive polarity is implied. Curreat Measurements 1. Set the Function/ switch to the highest 1000A ac range. 2. Press the trigger to open transformer jaws and clamp onto one conductor only, Read the current directly on the display. It is recommended that the conductor be placed at the center of the closed jaws for maximum accuracy. 6 3. When the reading is lower than 200 counts, set the range switch to the next lower range position. For maximum accuracy, select the lower range possible without overranging the meter. Resistance Measurements 1. Set the Function/ switch to the desired resistance range. 2. Remove power from the equipment under test. 3. Connect the red test lead to the + jack and the black test lead to the COM jack. 4. Touch the probes to the test points. In ohms, the value indicated in the display is the measured value of resistance. WARNING The accuracy of the functions might be slightly affected, when exposed to a radiated electromagnetic field environment, eg, radio, telephone or similar. Frequency Measurements 1. Set the Functian/ switch to the Hz position. 2. Connect the red test lead to the + jack and the black test lead to the COM jack. 3. Connect the test leads to the point of measurement and read the frequency from the display. Continuity Measurements 1. Set the Function/ switch to the / 2KV position. 2. Touch the probes to the test points. the beeper sounds continuously, if the resistance is less than 30V. 7 Diode Tests 1. Connect the red test lead to the + jack and the black test lead to the COM jack. 2. Set the Function/ switch to the position. 3. Turn off power to the circuit under test. 4. Touch probes to the diode. A forward-voltage drop is about 0.6V (typical for a silicon diode). 5. Reverse probes. If the diode is goad, OL is displayed. If the diode is shorted,.000 or another number is displayed. 6. If the diode is open, OL is displayed in both directions. 7. If the junction is measured in a circuit and a low reading is obtained with both lead connections, the junction may be shunted by a resistance of less than 1kV. In this case the diode must be disconnected from the circuit for accurate testing, MAINTENANCE WARNING : Remove test leads before changing battery or performing any servicing. Battery Replacement Power is supplied by a 9 volt transistor battery. (NEDA 1604, IEC 6F22). The appears on the LCD display when replacement is needed. Ta replace the battery, remove the two screws from the back of the meter and lift off the battery cover. Remove the battery from battery contacts. Cleaning Periodically wipe the case with a damp cloth and detergent, do not use abrasives or solvents. 8

N O T E Certificate of Calibration We hereby certify that this product has been calibrated and found to be in accordance with the applicable SPECIFICATIONS and STANDARDS. Accuracies of the standard equipment used in this calibration are traceable to the National Standards. MECO METERS PVT. LTD. Block 9, Plot 270, 2nd Floor, Rup-Udey Niwas, Sion (E), Mumbai - 400 022 (INDIA) Correspondance Address : Plot No. EL-1, MIDC Electronic Zone, TTC Industrial Area, Mahape, Navi Mumbai - 400710 (INDIA) Tel : 0091-22-27673311-16, 27673300 (Board) Fax : 0091-22-27673310, 27673330 E-mail : sales@mecoinst.com Web : www.mecoinst.com SR. NO. : CHECKED BY : DATE : 9 MODEL NO. : 10 N O T E N O T E 11 12