Isolation Transformer Series

Similar documents
500 kva Dry-type Isolation Transformer V-Delta to 208Y/120V 3PH - NEMA 1/Indoor

ULTRA-K Series 600K - he

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

80 kva Isolation Transformer - 480V AC Primary - 20V AC Secondary - NEMA 3R - Single Phase

500 kva Isolation Transformer - 480V Delta Primary - 400Y/231 Wye Secondary - NEMA 3R

T S 15KVA 1PH 240/480 Transformer

7.5 kva Isolation Transformer - 460V Primary - 230V Secondary - NEMA 3R - Single Phase - 50/60 Hz

Power-Sure 700. Technical Data TD158001EN. Contents

1.5 kva Single Phase Transformer - 120V Primary Voltage - 277V Secondary Voltage - NEMA 3R

225 kva Autotransformer - 240V Delta Primary Voltage - 220V Delta Secondary Voltage - NEMA 3R

Arild Furnes,ATPA OGP/Petrobras workshop, Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems

10 kva Transformer - 480V Primary Voltage - 208V Secondary Voltage - Single Phase - NEMA 3R

GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS

Power Quality Solutions

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

Tel: Fax:

75 kva Isolation Transformer V Delta Primary Voltage - 480Y/277 Secondary Voltage - NEMA 3R

75 kva Isolation Transformer - 480V Delta Primary - 208V Delta Secondary - NEMA 3R

Non-Linear Load Transformers

2kVA EARTH TESTING CURRENT INJECTION SYSTEM 4046 / 4047 DATASHEET REDPHASE INSTRUMENTS

SHORE TO SHIP FREQUENCY

OUTDOOR VOLTAGE TRANSFORMERS (Indoor units available) Description:

TOSHIBA International Corp

SWF DV/DT Solutions Sinewave Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

5 kva Isolation Transformer - 115V Primary Voltage - 230V Secondary Voltage - Single Phase - NEMA 3R

INTERNATIONAL TRANSFORMERS. Acme Electric s broad selection of CSA energy efficient transformers

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

2.2 American National Standards Institute Corporation and its applicable standards C39.1, C80.1, C89, C84.1.

Energy Efficient Distribution Transformers

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

VGM Series. 100 & 60 W, Efficient, CV Class 2 LED Drivers for Signage Applications ORDERING INFORMATION

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

WDG 61 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 12 - Technical Data Sheet

SINGLE PHASE BUCK & BOOST TRANSFORMERS INSTRUCTION MANUAL

and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads.

WDG 83 - Technical Data Sheet

Low Pass Harmonic Filters

PANELMDP Main Distribution Panel. Descriptions Energy Efficient Transformer

Compliant to DOE 10, CFR Part 431 (effective as of January 1 st, 2016)

VIM Series. 90 & 60 W, Efficient, CV Class 2 LED Drivers ORDERING INFORMATION

15 kva Isolation Transformer - Single Phase - 208V Primary - 120/240V Secondary - NEMA 3R

These true on-line inverters incorporate pulse width modulation (PWM) control combined with high frequency igbt power transistors.

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

SPECIFICATION FOR HORIZONTAL AIRFLOW OUTDOOR RESISTIVE LOAD BANK

2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers

Power Processor - Series 700F 10KVA to 150KVA

Est Static Frequency Converter. SFX 10kVA - 10MVA

Introduction. Centrado leading-edge transformer. Introduction

Est Static Frequency Converter. SFX 10kVA - 10MVA

High voltage shunt capacitor banks HIGH VOLTAGE COMPENSATION AND HARMONIC FILTERING PRODUCTS

K Factor Power Transformers

WDG 51 - Technical Data Sheet

FCL VOLTAGE & FREQUENCY CONVERTERS. FCL H SERIES - SINGLE PHASE - 2 to 30 kva H SERIES MODELS. AC SINGLE PHASE 2 TO 30 kva STATIC VARIABLE AC

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection:

PI734F - Winding 07. Technical Data Sheet APPROVED DOCUMENT

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

PI734F - Winding 28. Technical Data Sheet APPROVED DOCUMENT

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Load Isolation Transformers

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

Onsite Mobile AC High Voltage Test System

WDG 12 - Technical Data Sheet

These true online inverters integrate pulse width modulation (PWM) control combined with high frequency IGBT power transistors.

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

WDG 12 - Technical Data Sheet

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

WDG 71 - Technical Data Sheet

WDG 13 - Technical Data Sheet

WDG 07 - Technical Data Sheet

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

AC-DC ITE & Medical Switching Power Supply

StatiVolt. Inverter UPS Systems. Features. Contents

USER S MANUAL. 3KSS6050/ nd Edition

ISOLATING TRANSFORMERS FOR TLC PLANTS

PIRANHA 3 (3-phase, Power Conditioning Voltage Regulator)

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

General Description & Features Selection Charts Definition of Terms... 42

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

Dry Type Transformers Full Line Catalog. jeffersonelectric.com

S10N06P02P 2KVA 1PH 120/240V 16/32V Buck Boost Transformer. Descriptions

Copper Sheathed Cable Sheath Currents

VLM60/40 Series. 60 & 40 W, Efficient, Compact Constant Voltage Class 2 LED Drivers

Line Frequency Transformer

PI734E - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734C - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734B - Winding 312. Technical Data Sheet APPROVED DOCUMENT

USER S MANUAL. 1KSS60400/ ST Edition

SHI Series Pure Sine Wave Inverter (SHI2000 AND SHI3000) User s Manual

AC Resonant Test Systems Tank Type Up to 500 kv

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

Alternating Current Power

Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V

VOF XX - XXX - X

MYS WWSP PLUS III POWER UNIT

Transcription:

Isolation Transformer Series

Unit Shown With Options ITS Series - Isolation Transformer Series The La Marche Isolation Transformer Series (ITS) is designed for installation in industrial and harsh environment applications where reliable power is required. The La Marche ITS transformer protects circuits, equipment, and people from electric shocks and short circuits. The transformers are designed per UL safety requirements and manufactured using insulated copper windings with Class H insulation system. The La Marche ITS transformers are specifically engineered to operate at full load and full harmonic rating providing years of trouble free service. ITS is offered in a wide range of electrical transformers based on customer requirements and specifications. Single and three phase configurations are available in indoor and outdoor enclosures from 1 kva 40 kva. Specifications and Ratings 1 kva - 40 kva Single & Three Phase Dry Type Transformer NEMA 1 Robust Enclosure Design Copper Wound Designs High Efficiency Class H (180 C) Insulation System High Dielectric Strength IEC Terminal Blocks Convection Cooled UL Listing 10 Year Warranty Input Breaker* ISOLATION TRANSFORMER Output Breaker* Ground (Faraday) Shield Input / Output Breakers AC Metering (Voltage & Current) Harsh Environment Tropicalization (Glyptol Dip) Emergerncy Stop Switch AC ON LED NEMA 3R Enclosure Stainless Steel Enclosure Input Source Isolated Output PE

ITSM Series - Marine Isolation Transformer Series The danger of electrical shock and galvanic corrosion are greatly increased whenever 120V or 240V AC shore power is connected to a ship s electrical system. The function of the La Marche Marine Isolation Transformer is to reduce the potential between the ship and the shore in order to achieve: Personnel boarding the ship, personnel aboard the ship and the ship s metal parts will not be subject to electrical shock Electrolysis corrosion of the metal hull or hull fastenings will be reduced to a safe level Reduce EMI Interference and static from affecting the ship s electronic components Specifications and Ratings Earth Ground and Ship Ground Galvanic Isolation Ground (Faraday) Shield Water - Tight Cables Entry Harsh Environment Tropicalization (Glyptol Dip) NEMA 3R Robust Enclosure Design Same as ITS Series Same as ITS Series Unit Shown With Options The La Marche Marine Isolation Transformer features a Ground (Faraday) Shield between the power windings. This ground shield, when connected to the shore ground, provides protection against capacitive coupling between the shore power and the boat s electrical systems. This protects the boat electrical equipment against shore power issues, common mode voltage spikes, and the transfer of harmful energy between both systems. Reliable, Long Life - The ITSM is conservatively designed for continuous operation in harsh marine conditions inside an engine room environment. Trouble Free - Silent convection cooling eliminates the need for noisy fans and filter maintenance. There are not external controls or adjustments.

ITS - Isolation Transformer Technical Specifications ITS - kva - Ph - F - Vin - Vout - O Rating Winding Input Voltage 1 Phase or Three Phase (Delta/Star/ 3 Wires or 4 Wire) 110V, 120V, 208V, 480V, 600V (Multi-tap input is available) Output Voltage 110V, 120V, 208V, 480V, 600V (Multi-tap output is available) Frequency 1-40 kva 50Hz or 60Hz Effeciency Up to 99% Insulation Class H Insulation Di-Electric Strength 2500 Vac for 120 Secs Connectors IEC Approved Operating Ambient Temperature 50 C Model Number Rating Phase Frequency Input Voltage Output Voltage ITSM - Marine Isolation Transformer ITSM - kva - Ph - F - Vin - Vout - O Model Number Rating Phase Frequency Input Voltage Output Voltage www.lamarchemfg.com

Since 1945, La Marche has been providing reliable power conversion products. We are dedicated to the development and production of innovative quality products to meet our customer s electrical power requirements. La Marche products include Battery Chargers, UPS, Rectifiers, Power Supplies, Inverters, and others. We serve Utility, Telecommunications, Engine Start, Material Handling, Railroad, Marine and Mining markets. The Company is headquartered in Des Plaines, IL, USA. La Marche has over 45 representatives covering the USA, Canada, Hawaii, Alaska, Mexico, South America, Caribbea Islands, Africa and other locations. La Marche has built reputation by controlling all aspects of the development process including design, in-house manufacturing and testing. THE POWERFUL ADVANTAGE RELIABILITY YOU CAN TRUST CUSTOM SOLUTIONS U.S. COMPANY TECHNOLOGY 24 HOUR SERVICE www.lamarchemfg.com

La Marche Mfg Co. 106 Bradrock Dr Des Plaines, IL 60018 Tel: 001.847.299.1188 Fax: 001.847.299.3061 lamarche@lamarchemfg.com www.lamarchemfg.com