Series CCT-59S Multi-Throw DC-18 GHz, SP7T & SP8T Latching Coaxial Switch, Internal 50Ω Termination

Similar documents
Series CCT-38S Multi-Throw DC 12 GHz, SP7T & SP8T Normally Open Coaxial Switch

Series CCR-39S/CR-39S Multi-Throw DC-18 GHz/DC-22 GHz Latching Coaxial Switch

Series CCT-58S/CT-58S Multi-Throw DC-26.5 GHz Normally Open Coaxial Switch

Series CCT-58S/CT-58S Multi-Throw DC-26.5 GHz Normally Open Coaxial Switch

Series CCT-38S/CT-38S Multi-Throw DC 18 GHz/DC-22 GHz Normally Open Coaxial Switch

Series CCR-58S/CR-58S Multi-Throw DC 26.5 GHz Normally Open Coaxial Switch

Series CCS-19 Multi-Throw DC-2 GHz Latching Coaxial Switch

Series CCT-59S/CT-59S Multi-Throw DC-26.5 GHz Latching Coaxial Switch

Series CCR-48K/CR-48K Multi-Throw DC 40 GHz Normally Open Coaxial Switch

Series CCRS-53S/CRS-53S Miniature DC 26.5 GHz Latching 2P3T Coaxial Switch

Series CCRT-33S/CRT-33S Internal 50Ω Termination DC 18 GHz/DC-22 GHz Latching SPDT Coaxial Switch

Series CCRT-33S/CRT-33S Internal 50Ω Termination DC 18 GHz/DC-22 GHz Failsafe SPDT Coaxial Switch

Series CCRT-53S/CRT-53S Internal 50Ω Termination DC-26.5 GHz Failsafe SPDT Coaxial Switch

Series CCR-33S/CR-33S Miniature DC 18 GHz/DC-22 GHz Latching SPDT Coaxial Switch

Series CCRS-53S/CRS-53S Miniature DC 26.5 GHz Failsafe 2P3T Coaxial Switch

Series CCS-37S/CS-37S Miniature DC 18 GHz Latching TRANSFER Coaxial Switch

Series CCRS-33S/CRS-33S Miniature DC 18 GHz Failsafe 2P3T Coaxial Switch

Series CCP-47N Low PIM DC 3 GHz Latching TRANSFER Coaxial Switch

Series CCS-37S/CS-37S Miniature DC 18 GHz Failsafe TRANSFER Coaxial Switch

Series CCP-32N Low PIM DC 3 GHz Latching SPDT Coaxial Switch

Series CCR-33S/CR-33S Miniature DC 18 GHz/DC-22 GHz Failsafe SPDT Coaxial Switch

Series CCR-53S/CR-53S Miniature DC 26.5 GHz Latching SPDT Coaxial Switch

Series CCR-33K/CR-33 K Miniature DC 33.5 GHz Failsafe SPDT Coaxial Switch

Series CCR-40K/CR-40K Miniature DC 40 GHz Latching SPDT Coaxial Switch

Series CCS-47/CS-47 High Power DC 12 GHz Failsafe TRANSFER Coaxial Switch

Series CCS-47/CS-47 High Power DC 12 GHz Latching TRANSFER Coaxial Switch

Series CCR-33K/CR-33K Miniature DC 33.5 GHz Failsafe SPDT Coaxial Switch

Series CCR-33K/CR-33K Miniature DC 33.5 GHz Latching SPDT Coaxial Switch

Series CCS-37K/CS-37K Miniature DC 36 GHz Latching TRANSFER Coaxial Switch

Series CCS-32/CS-32 High Power DC 12 GHz Failsafe SPDT Coaxial Switch

Series H-33S DC up to 26.5 GHz Latching SPDT Space Grade Coaxial Switch

Series H-47N DC up to 12 GHz Latching Transfer Space Grade Coaxial Switch

PAGE 1/12 ISSUE SERIES DP3T/SPDT PART NUMBER R595 XXX XXX

Failsafe Latching SPDT. Up to 8T High Power

TITANIUM SERIES R 51 PART NUMBER SELECTION. High Performance Multiport Switches. Our Most Important Connection is with You.

DPDT/TRANSFER COAXIAL SWITCH

DPDT (TRANSFER) COAXIAL SWITCH

FMSW6129 DATA SHEET. SP4T Normally Open Electro-Mechanical Relay Switch From DC to 22 GHz, 20 Watts with Indicators, TTL, Diodes, SMA.

Standard Custom Electro-Mechanical Switches

RAMSES SERIES R 570 PART NUMBER SELECTION. SPDT up to 18 GHz. Our Most Important Connection is with You. N - TNC - BNC

FMSW6097 DATA SHEET. SPDT Failsafe Electro-Mechanical Relay Switch From DC to 26.5 GHz, 20 Watts with TTL, Diodes, Indicators, SMA.

Standard Custom Electro-Mechanical Switches

SEMS-4079-SP8T-SMA DATA SHEET

Standard Custom Electro-Mechanical Switches

MAGNETIC-LATCHING DPDT HALF-SIZE CRYSTAL CAN HIGH POWER RF RELAY DC-3 GHZ

FMSW6124 DATA SHEET. Transfer Latching Electro-Mechanical Relay Switch From DC to 40 GHz, 5 Watts with Indicators, TTL, Self Cut Off, Diodes, 2.

MAGNETIC-LATCHING DC-8 GHz TO-5 RELAYS 4PST

433 & 443 Series INTELLIGENT RELAY SP3T & SP4T IN-LINE Multithrow Switches

Stocked Electro-Mechanical Switches

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT DC-4 GHz

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

HIGH REPEATABILITY, TO-5 RELAYS DPDT

Our Experience As the world s largest manufacturer of electromechanical switches, Dow-Key Microwave Corporation is committed to providing unparalleled

Agilent 8761A/B Microwave Switches

SDA SMA DATA SHEET

Solid State PIN Control Products

Series HD 2A, 60Vdc, True Output Status Feedback, Short-Circuit Protected DC Solid-State Relay

TABLE OF CONTENTS. RF Connector/Type. Dow-Key Microwave Ordering Information. Power Chart: Standard Switches.

Agilent 8761A/B Microwave Switches

COAXIAL SWITCHES GENERAL INFORMATION WIDE FIELD OF ACTIVITY EXPERIENCE

Coaxial switching products

100W Wide Band Power Amplifier 6GHz~18GHz. Parameter Min. Typ. Max. Min. Typ. Max. Units. Frequency Range GHz Gain db

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

PAGE 1/6 ISSUE SERIES Micro-SPDT PART NUMBER R516 XXX 10X. (All dimensions are in mm [inches]) R 516 _ 1 0 _

Parameter Min. Typ. Max. Units. Frequency Range 8-11 GHz. Saturated Output Power (Psat) 52 dbm. Input Max Power (No Damage) Psat Gain dbm

MAGNETIC-LATCHING ESTABLISHED RELIABILITY TO-5 RELAYS DPDT RELAY TYPE. DPDT relay with internal diode for coil transient suppression

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

MSW3T SP3T Surface Mount High Power PIN Diode Switch

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

Keysight Technologies 87104/6D Multiport Electromechanical Coaxial Switches

Return Loss Bridge Basics

SP4T RF Switch 50 Ω Absorptive RF switch 1 to 6000 MHz Internal driver, Single Supply Voltage 2.3V to 3.6V

Features. = +25 C, Vdd = +5 Vdc, 50 Ohm System. trise, tfall (10/90% RF) ton, toff (50% CTL to 10/90% RF)

MSW2T /MSW2T /MSW2T SP2T Surface Mount High Power PIN Diode Switch

Solid State PIN Control Products

20W Solid State Power Amplifier 26.2GHz~34GHz. Parameter Min. Typ. Max. Min. Typ. Max. Units. Frequency Range GHz.

Isolation db Input VSWR : 1 Output VSWR : 1 RF Input Power (Pulsed, 10% Duty Cycle, 20us pulse

Agilent 87104/87106A, B, C Multiport Coaxial Switches dc to 4 GHz, dc to 20 GHz, dc to 26.5 GHz

Coaxial Switch. Ordering Information. High-frequency, High-capacity Coaxial Switch Supporting Bandwidth to 26.5 GHz. Model Number Legend:

HIGH REPEATABILITY SPDT, BROADBAND 12 GHZ, 20 Gbps MAGNETIC-LATCHING RF RELAY

ponents Com ped Lum Lumped Components

PAGE 1/6 ISSUE Jul SERIES Micro-SPDT PART NUMBER R516 XXX 10X R 516 _ 1 0 _

CENTIGRID ESTABLISHED RELIABILITY RELAYS

SURFACE MOUNT HIGH REPEATABILITY SPDT, BROADBAND 18 GHZ 40GBPS MAGNETIC-LATCHING RF RELAY

Agilent 8766/7/8/9K Microwave Single-Pole Multi-Throw Switches

LoopBack Relay. GLB363 Series. With Built-in AC Bypass Capacitors / DC LoopBack Relay

HIGH-VALUE PHASE-LOCKED COAXIAL RESONATOR OSCILLATOR

LoopBack Relay. LB363 Series. With Built-in AC Bypass Capacitors. LoopBack Relay, Sensitive Coil, thru-hole with AC Bypass Capacitors

Solid State General Communication Power Amplifier

HIGH REPEATABILITY, DC-8 GHz/20Gbps TO-5 RELAYS, DPDT

SURFACE MOUNT HIGH REPEATABILITY SPDT, BROADBAND 16 GHZ 40GBPS MAGNETIC-LATCHING RF RELAY

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

12D05A L- & S-Band Solid State Power Amplifier

MSW2T /MSW2T /MSW2T SP2T Surface Mount High Power PIN Diode Switch

Solid State PIN Control Products

Transcription:

COAX SWITCHES Series CCT-59S PART NUMBER CCT-59S DESCRIPTION Commercial Latching Multi-throw, DC-18GHz The CCT-59S is a broadband, multi-throw, electromechanical coaxial switch designed to switch a microwave signal from a common input to any of 7 or 8 outputs. The characteristic impedance is 50 Ohms. Each position has an individual actuator mechanism allowing random position selection. This also minimizes switching time. The CCT-59S comes with a latching actuator. The latching switch remains in the last position selected when the switch is de-energized. STD dual command requires a reset pulse before a new selected position. A separate reset circuit allows all positions to be set to an open position. User must provide both reset (clear) and set (select new position) commands. ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS Operating Temperature Commercial Model, CCT-39S 40 C to 65 C Vibration (MIL-STD-202 Method 214, 10 g s RMS Condition D, non-operating) Shock (MIL-STD-202 Method 213, 500 g s Condition D, non-operating) Standard Actuator Life Actuator Life w/ Additional Features Connector Type Humidity (Moisture Seal) Weight 3,000,000 cycles 1,000,000 cycles SMA Available 9 oz. (255.2g) (max.) ELECTRICAL CHARACTERISTICS Form Factor Multi-Throw, break before make Frequency Range CCT-39S DC 18 GHz Characteristic Impedance 50 Ohms Operate Time 20 ms (max.) Actuation Voltage Available 12 15 24 28 V Actuation Current 140 105 90 105 ma Reset Currents (# of positions) (7) 770 735 630 735 ma (8) 880 840 720 840 ma TYPICAL PERFORMANCE CHARACTERISTICS Frequency DC 6 GHz 6 12 GHz 12-18 GHz Insertion Loss, db, typ. 0.20 0.40 0.60 Isolation, db, typ. 70 60 60 VSWR, typ. 1.30:1 1.40:1 1.70:1 For maximum limits, please see charts on pages 7 PART NUMBERING SYSTEM CCT-59 S 6 8 C - T **1 Series Connectors Actuator Voltage Options Actuator Type Number of Positions CONNECTOR ACTUATOR VOLTAGE NUMBER OF POSITIONS ACTUATOR TYPE OPTIONS S: SMA FEMALE 6: 28 VDC LATCHING 7: SP7T 0: NO INDICATOR CONTACTS T: TTL DRIVERS WITH DIODES 7: 15 VDC LATCHING 8: SP8T C: INDICATOR CONTACTS D: COIL TRANSIENT SUPPRESSION DIODES 8: 12 VDC LATCHING D: SELF CUTOFF ONLY*** R: POSITIVE + COMMON 9: 24 VDC LATCHING E: INDICATORS AND SELF CUTOFF*** TD: DECODERS AND TTL DRIVERS WITH DIODES ** SEE PART NUMBER ON PAGE 10 M: MOISTURE SEAL *** Indicator Contacts Operating Temperature -50 C to 85 C (Elite Model Only) S: D-SUB CONNECTOR* For additional options, please contact factory. * D-Sub Connector may be 15 or 26 pin depending on number of throws. (See Connector Pinout page) ** 1 D-Sub Connectors is standard configuration on all models unless otherwise specified 2018 TELEDYNE RELAYS (800) 284-7007 www.teledynecoax.com CCT-59S Page 1

Series CCT-59S COAX SWITCHES SCHEMATICS AND MECHANICAL OUTLINE -S OPTION 15-PIN D-SUB OR 26-PIN D-MICRO CONNECTOR (EXAMPLE: CCT-39S680-S) CCT-59 Page 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 2018 TELEDYNE COAX SWITCHES

COAX SWITCHES Series CCT-59S CONNECTOR PINOUT FOR LATCHING SP7T MULTI-THROW SWITCHES EXAMPLE CCT-59S670-S CCT-59S67C-S CCT-59S670-TS CCT-59S67C-TS CCT-59S670-TDS CCT-59S67C-TDS INDICATOR YES YES YES TTL YES YES DECODERS & TTL YES YES PIN NO. 15-PIN 26-PIN 15-PIN 26-PIN 15-PIN 26-PIN 1 PORT 1 PORT 1 TTL 1 TTL 1 LOGIC 1 LOGIC 1 15-PIN D-SUB CONNECTOR 2 PORT 2 PORT 2 TTL 2 TTL 2 LOGIC 2 LOGIC 2 3 PORT 3 PORT 3 TTL 3 TTL 3 LOGIC 3 LOGIC 3 4 PORT 4 PORT 4 TTL 4 TTL 4 5 PORT 5 PORT 5 TTL 5 TTL 5 6 PORT 6 PORT 6 TTL 6 TTL 6 7 PORT 7 PORT 7 TTL 7 TTL 7 26-PIN D-SUB CONNECTOR 8 9 10 11 12 13 VSW VSW VSW VSW 14 Reset Reset Reset Reset 15 COMMMON COMMMON COMMMON COMMMON COMMMON COMMMON 16 D Indicator (COM) D Indicator (COM) D Indicator (COM) 17 E Indicator E Indicator E Indicator 18 F Indicator F Indicator F Indicator 19 G Indicator G Indicator G Indicator 20 H Indicator H Indicator H Indicator 21 K Indicator K Indicator K Indicator 22 L Indicator L Indicator L Indicator 23 M Indicator M Indicator M Indicator 24 25 26 2018 TELEDYNE RELAYS (800) 284-7007 www.teledynecoax.com CCT-59S Page 3

Series CCT-59S COAX SWITCHES SP7T TRUTH TABLE Latching CCT-59SX7C-T Logic Input RF Path Indicator Switches 1 2 3 4 5 6 7 R J1 J2 J3 J4 J5 J6 J7 Reset E F G H K L M 1 0 0 0 0 0 0 0 On Off Off Off Off Off Off Off C 0 0 0 0 0 0 0 1 0 0 0 0 0 0 Off On Off Off Off Off Off Off 0 C 0 0 0 0 0 0 0 1 0 0 0 0 0 Off Off On Off Off Off Off Off 0 0 C 0 0 0 0 0 0 0 1 0 0 0 0 Off Off Off On Off Off Off Off 0 0 0 C 0 0 0 0 0 0 0 1 0 0 0 Off Off Off Off On Off Off Off 0 0 0 0 C 0 0 0 0 0 0 0 1 0 0 Off Off Off Off Off On Off Off 0 0 0 0 0 C 0 0 0 0 0 0 0 1 0 Off Off Off Off Off Off On Off 0 0 0 0 0 0 C TRUTH TABLE Latching CCT-59SX7C-TD Logic Input RF Path Indicator Switches 1 2 3 4 J1 J2 J3 J4 J5 J6 J7 Reset E F G H K L M 0 0 0 0 On Off Off Off Off Off Off Off C 0 0 0 0 0 0 1 0 0 0 Off On Off Off Off Off Off Off 0 C 0 0 0 0 0 0 1 0 0 Off Off On Off Off Off Off Off 0 0 C 0 0 0 0 1 1 0 0 Off Off Off On Off Off Off Off 0 0 0 C 0 0 0 0 0 1 0 Off Off Off Off On Off Off Off 0 0 0 0 C 0 0 1 0 1 0 Off Off Off Off Off On Off Off 0 0 0 0 0 C 0 0 1 1 0 Off Off Off Off Off Off On Off 0 0 0 0 0 0 C 1 1 1 0 Off Off Off Off Off Off Off Reset 0 0 0 0 0 0 0 1 1 1 1 COIL OFF 0 0 0 0 0 0 0 CCT-59 Page 4 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 2018 TELEDYNE COAX SWITCHES

COAX SWITCHES Series CCT-59S CONNECTOR PINOUT FOR LATCHING SP8T MULTI-THROW SWITCHES EXAMPLE CCT-59S680-S CCT-59S68C-S CCT-59S680-TS CCT-59S68C-TS CCT-59S680-TDS CCT-59S68C-TDS INDICATOR YES YES YES TTL YES YES DECODERS & TTL YES YES PIN NO. 15-PIN 26-PIN 15-PIN 26-PIN 15-PIN 26-PIN 1 PORT 1 PORT 1 TTL 1 TTL 1 LOGIC 1 LOGIC 1 15-PIN D-SUB CONNECTOR 2 PORT 2 PORT 2 TTL 2 TTL 2 LOGIC 2 LOGIC 2 3 PORT 3 PORT 3 TTL 3 TTL 3 LOGIC 3 LOGIC 3 4 PORT 4 PORT 4 TTL 4 TTL 4 LOGIC 4 LOGIC 4 5 PORT 5 PORT 5 TTL 5 TTL 5 6 PORT 6 PORT 6 TTL 6 TTL 6 7 PORT 7 PORT 7 TTL 7 TTL 7 26-PIN D-SUB CONNECTOR 8 PORT 8 PORT 8 TTL 8 TTL 8 9 10 11 12 13 Vsw Vsw Vsw Vsw 14 Reset Reset Reset Reset 15 Common Common Common Common Common Common 16 D Indicator (COM) D Indicator (COM) D Indicator (COM) 17 E Indicator E Indicator E Indicator 18 F Indicator F Indicator F Indicator 19 G Indicator G Indicator G Indicator 20 H Indicator H Indicator H Indicator 21 K Indicator K Indicator K Indicator 22 L Indicator L Indicator L Indicator 23 M Indicator M Indicator M Indicator 24 N Indicator N Indicator N Indicator 25 26 2018 TELEDYNE RELAYS (800) 284-7007 www.teledynecoax.com CCT-59S Page 5

Series CCT-59S COAX SWITCHES SP8T TRUTH TABLE Latching CCT-59SX8C-T Logic Input RF Path Indicator Switches 1 2 3 4 5 6 7 8 R J1 J2 J3 J4 J5 J6 J7 J8 Reset E F G H K L M N 1 0 0 0 0 0 0 0 0 On Off Off Off Off Off Off Off Off C 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 Off On Off Off Off Off Off Off Off 0 C 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 Off Off On Off Off Off Off Off Off 0 0 C 0 0 0 0 0 0 0 0 1 0 0 0 0 0 Off Off Off On Off Off Off Off Off 0 0 0 C 0 0 0 0 0 0 0 0 1 0 0 0 0 Off Off Off Off On Off Off Off Off 0 0 0 0 C 0 0 0 0 0 0 0 0 1 0 0 0 Off Off Off Off Off On Off Off Off 0 0 0 0 0 C 0 0 0 0 0 0 0 0 1 0 0 Off Off Off Off Off Off On Off Off 0 0 0 0 0 0 C 0 0 0 0 0 0 0 0 1 0 Off Off Off Off Off Off Off On Off 0 0 0 0 0 0 0 C TRUTH TABLE Latching CCT-59SX8C-TD Logic Input RF Path Indicator Switches 1 2 3 4 J1 J2 J3 J4 J5 J6 J7 J8 Reset E F G H K L M N 0 0 0 0 On Off Off Off Off Off Off Off Off C 0 0 0 0 0 0 0 1 0 0 0 Off On Off Off Off Off Off Off Off 0 C 0 0 0 0 0 0 0 1 0 0 Off Off On Off Off Off Off Off Off 0 0 C 0 0 0 0 0 1 1 0 0 Off Off Off On Off Off Off Off Off 0 0 0 C 0 0 0 0 0 0 1 0 Off Off Off Off On Off Off Off Off 0 0 0 0 C 0 0 0 1 0 1 0 Off Off Off Off Off On Off Off Off 0 0 0 0 0 C 0 0 0 1 1 0 Off Off Off Off Off Off On Off Off 0 0 0 0 0 0 C 0 1 1 1 0 Off Off Off Off Off Off Off On Off 0 0 0 0 0 0 0 C 0 0 0 1 Off Off Off Off Off Off Off Off Reset 0 0 0 0 0 0 0 0 1 1 1 1 COIL OFF 0 0 0 0 0 0 0 0 CCT-59 Page 6 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 2018 TELEDYNE COAX SWITCHES

COAX SWITCHES Series CCT-59S TYPICAL RF PERFORMANCE CURVES Insertion Loss (DC-12 GHz) 0-0.1-0.2 Insertion Loss (db) -0.3-0.4-0.5-0.6-0.7-0.8-0.9-1 0 2 4 6 8 10 12 Frequency (GHz) 2.0 1.9 1.8 VSWR (DC-12 GHz) VSWR ( db) 1.7 1.6 1.5 1.4 1.3 1.2 1.1 1.0 0 2 4 6 8 10 12 Frequency (GHz) 0 Isolation (DC-12 GHz) -20 Isolatioin (db) -40-60 -80-100 -120-140 0 2 4 6 8 10 12 Frequency (GHz) TYPICAL MAXIMUM TEST LIMIT 2018 TELEDYNE RELAYS (800) 284-7007 www.teledynecoax.com CCT-59S Page 7

Series CCT-59S COAX SWITCHES TYPICAL POWER PERFORMANCE CURVE 3000 2000 Power Handling vs. Frequency 1000 800 600 Power (W) 400 300 200 100 80 60 STANDARD SMA SWITCHES 40 30 20 10.1.2.3.4.6.8 1 2 4 6 8 10 12 Frequency GHz Estimates based on the following reference conditions: Ambient temperature of 40 C or less Sea level operation Load VSWR of 1.20:1 maximum No high-power (hot) switching Please contact Teledyne Coax Switches for derating factors when applications do not meet the foregoing reference conditions. CCT-59 Page 8 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 2018 TELEDYNE COAX SWITCHES

COAX SWITCHES Series CCT-59S GLOSSARY Actuator An actuator is the electromechanical mechanism that transfers the RF contacts from one position to another upon DC command. Arc Suppression Diode A diode is connected in parallel with the coil. This diode limits the reverse EMF spike generated when the coil de-energizes to 0.7 volts. The diode cathode is connected to the positive side of the coil and the anode is connected to the negative side. Date Code All switches are marked with either a unique serial number or a date code. Date codes are in accordance with MIL-STD-1285 Paragraph 5.2.5 and consist of four digits. The fi rst two digits defi ne the year and the last two digits defi ne the week of the year (YYWW). Thus, 1032 identifi es switches that passed through fi nal inspection during the 32nd week of 2010. Indicator Indicators tell the system which position the switch is in. Other names for indicators are telemetry contacts or tellback circuit. Indicators are usually a set of internally mounted DC contacts linked to the actuator. They can be wired to digital input lines, status lights, or interlocks. Unless otherwise specifi ed, the maximum indicator contact rating is 30 Vdc, 50 ma, or 1.5 Watts into a resistive load. Isolation Isolation is the measure of the power level at the output connector of an unconnected RF channel as referenced to the power at the input connector. It is specifi ed in db below the input power level. Multi-Throw Latching Switch A multi-throw switch is a switch with one input and three or more output ports. The CCR-39 can switch a microwave signal to any of 8 outputs from a single common input. Switching Time Switching time is the total interval beginning with the arrival of the leading edge of the command pulse at the switch DC input and ending with the completion of the switch transfer, including contact bounce. It consists of three parts: (1) inductive delay in the coil, (2) transfer time of the physical movement of the contacts, and (3) the bounce time of the RF contacts. TTL Switch Driver Option As a special option, switch drivers can be provided for both failsafe and latching switches, which are compatible with industry-standard low-power Schottky TTL circuits. Actuator Current vs Temperature The resistance of the actuator coil varies as a function of temperature. There is an inverse relationship between the operating temperature of the switch and the actuator drive current. For switches operating at 28 VDC, the approximate actuator drive current at temperature, T, can be calculated using the equation: I T = Where: I A [1 +.00385 (T-20)] I T = Actuator current at temperature, T I A = Room temperature actuator current see data sheet T = Temperature of interest in C Magnetic Sensitivity An electro-mechanical switch can be sensitive to ferrous materials and external magnetic fi elds. Neighboring ferrous materials should be permitted no closer than 0.5 inches and adjacent external magnetic fi elds should be limited to a fl ux density of less than 5 Gauss. SPECIAL FEATURE Switching High-Power or Highly Sensitive Signals Ensure the most linear response with the best galvanically matched contact system in the industry. Extremely low passive intermodulation is standard on all of our switches. Carrier Frequency 1 Carrier Frequency 2 PIM 3rd Order Frequency PIM 5th Order Frequency 870 MHz 893 MHz 847 MHz 824 MHz Multiple Positions 3rd Order Intermodulation 5th Order Intermodulation 96 dbm 115 dbm 139 dbc 158 dbc TD-Option This option includes a decoder. The 3-bit parallel command is decoded to internally select the appropriate position. See the logic tables. The TD-Option increases the Vsw supply current demand by 50mA max at 28Vdc and +20 C. Performance Parameters vs Frequency Generally speaking, the RF performance of coaxial switches is frequency dependent. With increasing frequency, VSWR and insertion loss increase while isolation decreases. All data sheets specify these three parameters as worst case at the highest operating frequency. If the switch is to be used over a narrow frequency band, better performance can be achieved. 2018 TELEDYNE RELAYS (800) 284-7007 www.teledynecoax.com CCT-59S Page 9

Series CCT-59S COAX SWITCHES LATCHING CCT-39S PART NUMBER LIST PART NO. PART NO. PART NO. PART NO. 1 CCT-59SX7C 43 CCT-59SX70-TMS 85 CCT-59SX8C-MS 127 CCT-59SX8D-RS 2 CCT-59SX7C-D 44 CCT-59SX70-TS 86 CCT-59SX8C-R 128 CCT-59SX8D-S 3 CCT-59SX7C-DM 45 CCT-59SX7D 87 CCT-59SX8C-RM 129 CCT-59SX8D-T 4 CCT-59SX7C-DR 46 CCT-59SX7D-M 88 CCT-59SX8C-RMS 130 CCT-59SX8D-TD 5 CCT-59SX7C-DRM 47 CCT-59SX7D-MS 89 CCT-59SX8C-RS 131 CCT-59SX8D-TDM 6 CCT-59SX7C-DRS 48 CCT-59SX7D-R 90 CCT-59SX8C-S 132 CCT-59SX8D-TDMS 7 CCT-59SX7C-DS 49 CCT-59SX7D-RM 91 CCT-59SX8C-T 133 CCT-59SX8D-TDS 8 CCT-59SX7C-M 50 CCT-59SX7D-RMS 92 CCT-59SX8C-TD 134 CCT-59SX8D-TM 9 CCT-59SX7C-MS 51 CCT-59SX7D-RS 93 CCT-59SX8C-TDM 135 CCT-59SX8D-TMS 10 CCT-59SX7C-R 52 CCT-59SX7D-S 94 CCT-59SX8C-TDMS 136 CCT-59SX8D-TS 11 CCT-59SX7C-RM 53 CCT-59SX7D-T 95 CCT-59SX8C-TDS 137 CCT-59SX8E 12 CCT-59SX7C-RMS 54 CCT-59SX7D-TD 96 CCT-59SX8C-TM 138 CCT-59SX8E-M 13 CCT-59SX7C-RS 55 CCT-59SX7D-TDM 97 CCT-59SX8C-TMS 139 CCT-59SX8E-MS 14 CCT-59SX7C-S 56 CCT-59SX7D-TDMS 98 CCT-59SX8C-TS 140 CCT-59SX8E-R 15 CCT-59SX7C-T 57 CCT-59SX7D-TDS 99 CCT-59SX80 141 CCT-59SX8E-RM 16 CCT-59SX7C-TD 58 CCT-59SX7D-TM 100 CCT-59SX80-D 142 CCT-59SX8E-RMS 17 CCT-59SX7C-TDM 39 CCT-59SX7D-TMS 101 CCT-59SX80-DM 143 CCT-59SX8E-RS 18 CCT-59SX7C-TDMS 60 CCT-59SX7D-TS 102 CCT-59SX80-DR 144 CCT-59SX8E-S 19 CCT-59SX7C-TDS 61 CCT-59SX7E 103 CCT-59SX80-DRM 145 CCT-59SX8E-T 20 CCT-59SX7C-TM 62 CCT-59SX7E-M 104 CCT-59SX80-DRS 146 CCT-59SX8E-TD 21 CCT-59SX7C-TMS 63 CCT-59SX7E-MS 105 CCT-59SX80-DS 147 CCT-59SX8E-TDM 22 CCT-59SX7C-TS 64 CCT-59SX7E-R 106 CCT-59SX80-M 148 CCT-59SX8E-TDMS 23 CCT-59SX70 65 CCT-59SX7E-RM 107 CCT-59SX80-MS 149 CCT-59SX8E-TDS 24 CCT-59SX70-D 66 CCT-59SX7E-RMS 108 CCT-59SX80-R 150 CCT-59SX8E-TM 25 CCT-59SX70-DM 67 CCT-59SX7E-RS 109 CCT-59SX80-RM 151 CCT-59SX8E-TMS 26 CCT-59SX70-DR 68 CCT-59SX7E-S 110 CCT-59SX80-RMS 152 CCT-59SX8E-TS 27 CCT-59SX70-DRM 69 CCT-59SX7E-T 111 CCT-59SX80-RS 28 CCT-59SX70-DRS 70 CCT-59SX7E-TD 112 CCT-59SX80-S 29 CCT-59SX70-DS 71 CCT-59SX7E-TDM 113 CCT-59SX80-T 30 CCT-59SX70-M 72 CCT-59SX7E-TDMS 114 CCT-59SX80-TD 31 CCT-59SX70-MS 73 CCT-59SX7E-TDS 115 CCT-59SX80-TDM 32 CCT-59SX70-R 74 CCT-59SX7E-TM 116 CCT-59SX80-TDMS 33 CCT-59SX70-RM 75 CCT-59SX7E-TMS 117 CCT-59SX80-TDS 34 CCT-59SX70-RMS 76 CCT-59SX7E-TS 118 CCT-59SX80-TM 35 CCT-59SX70-RS 77 CCT-59SX8C 119 CCT-59SX80-TMS 36 CCT-59SX70-S 78 CCT-59SX8C-D 120 CCT-59SX80-TS 37 CCT-59SX70-T 79 CCT-59SX8C-DM 121 CCT-59SX8D 38 CCT-59SX70-TD 80 CCT-59SX8C-DR 122 CCT-59SX8D-M 39 CCT-59SX70-TDM 81 CCT-59SX8C-DRM 123 CCT-59SX8D-MS 40 CCT-59SX70-TDMS 82 CCT-59SX8C-DRS 124 CCT-59SX8D-R 41 CCT-59SX70-TDS 83 CCT-59SX8C-DS 125 CCT-59SX8D-RM 42 CCT-59SX70-TM 84 CCT-59SX8C-M 126 CCT-59SX8D-RMS * X = 6 (28Vdc), 7 (15Vdc), 8 (12Vdc) and 9 (24Vdc) CCT-59 Page 10 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 2018 TELEDYNE COAX SWITCHES