The MFT B-Series Flow Controller.

Similar documents
Kurz Instruments Inc. 19 August 2010

Application Note CTAN #287

PID-CONTROL FUNCTION AND APPLICATION

Micro Motion Model 2700 Transmitters with Configurable Input/Outputs 2700***B 2700***C. Configuration and Use Manual Supplement

Bulletin 1402 Line Synchronization Module (LSM)

HPVFP High Performance Full Function Vector Frequency Inverter

VS-616G5 Series (Revision F) Programming Manual. Constant Torque Inverter with Adaptive Vector Control (AVC )

MA7200 PLUS INVERTER SERIES PID Quick Start Manual For Fan and Pump Applications

8510 AC Spindle Drive System

Micro Motion Model 1700 Transmitters with Analog Outputs 1700***A. Configuration and Use Manual Supplement. Configuration Operation Maintenance

Product Manual SE1000. Description The SE1000 is a microprocessor-based pulse monitoring interface designed to monitor up to four pulse inputs.

GB QUICK GUIDE FOR THE CONFIGURATION OF VARIABLE SPEED DRIVES

Basic Tuning for the SERVOSTAR 400/600

Enhanced PID for Air Compressors F7 Drive Software Technical Manual

USER MANUAL. EPP Intelligent Positioner Control Unit 1/22.

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

CSMIO/IP-A motion controller and Mach4

Kurz Instruments Inc. December 27, 2007

Servo Indexer Reference Guide

SRV02-Series Rotary Experiment # 3. Ball & Beam. Student Handout

vacon 100 flow ac drives application manual

vacon 100 flow ac drives application manual

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

SxWEB PID algorithm experimental tuning

CHAPTER 11: DIGITAL CONTROL

Servo Tuning Tutorial

Effective Teaching Learning Process for PID Controller Based on Experimental Setup with LabVIEW

STEP 3: TIME PROPORTIONING CONTROL If you re using discrete outputs for PID control, you will need to determine your time period for the output.

HC-220 PID Controller

A U T O E S C M E N U

Actuating Terminal Equipment Controller (ATEC) Base VAV - Cooling or Heating, Application Application Note

Mercury Firmware Release Notes

QUICK GUIDE PUMP CONTROL. Frequency inverter for pump control and HVAC applications. Date Version 24/10/

Teaching Mechanical Students to Build and Analyze Motor Controllers

Application Note #2442

Feedback Systems in HVAC ASHRAE Distinguished Lecture Series Jim Coogan Siemens Building Technologies

Multi-function, Compact Inverters. 3G3MV Series

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

1. INTRODUCTION Fire Mode PID Application Parameter lists DESCRIPTION OF PARAMETERS... 8

Different Controller Terms

Before you operate the inverter, the parameters that you must first program are the basic parameters.

EE 308 Spring Preparation for Final Lab Project Simple Motor Control. Motor Control

Chapter 10 Digital PID

Automate. Hardware: Software: 1. Somove Lite V (or latest version available) for drive configuration optional

Draw the symbol and state the applications of : 1) Push button switch 2) 3) Solenoid valve 4) Limit switch ( 1m each) Ans: 1) Push Button

Automationdirect.com. D i r e c t L o g i c L o o p P I D C o p r o c e s s o r F P I D

Procidia Control Solutions Dead Time Compensation

Rotary Motion Servo Plant: SRV02. Rotary Experiment #02: Position Control. SRV02 Position Control using QuaRC. Student Manual

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

Rectilinear System. Introduction. Hardware

CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6

TC LV-Series Temperature Controllers V1.01

E3 Adjustable Speed Drive Engineering Specification

FUJI Inverter. Standard Specifications

THE APOLLO INTELLIGENT METER SERIES MODEL IMD1 INSTRUCTION MANUAL

Application Note AN-SERV-002

BOILER MANAGEMENT SYSTEM

5 Lab 5: Position Control Systems - Week 2

Granular Spinner Spreader Module Quick Reference Sheet

The Discussion of this exercise covers the following points: Angular position control block diagram and fundamentals. Power amplifier 0.

QUICK GUIDE PUMP CONTROL. Frequency inverter for pump control and HVAC applications. Date Version 22/09/

Determining the Dynamic Characteristics of a Process

Application Note. Renu Electronics Private Limited. PID Instruction In IEC. Page 1

P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control

Advanced user guide. Commander SX. IP66/Nema 4X AC Variable Speed Drive en / a. Part Number :

1. Vacon Startup Startup Wizard PID Mini-Wizard Multi-pump mini-wizard... 5

CHAPTER 1 INTRODUCTION...

Step vs. Servo Selecting the Best

HITACHI. L100-M Series Inverter Quick Reference Guide. Hitachi Industrial Equipment Systems Co., Ltd. Single-phase Input 100V Class

Elmo HARmonica Hands-on Tuning Guide

Appendix F: PID Control...F 1 PID Control...F 2

TECHNICAL DOCUMENT EPC SERVO AMPLIFIER MODULE Part Number L xx EPC. 100 Series (1xx) User Manual

Ch 5 Hardware Components for Automation

THE APOLLO INTELLIGENT METER SERIES MODEL IMS INSTRUCTION MANUAL

THE APOLLO INTELLIGENT METER SERIES MODEL IMP INSTRUCTION MANUAL

Technical Information

Rotary Motion Servo Plant: SRV02. Rotary Experiment #03: Speed Control. SRV02 Speed Control using QuaRC. Student Manual

Instruction Notes for 108A L Sensor Input

ET2000e IRRIGATION CONTROLLER

Lab 2, Analysis and Design of PID

The GS1 Digital Keypad LED Display Function Keys Displaying the Status of the GS1 AC Drive Programming the GS1 AC Drive...

TABLE OF CONTENTS CHAPTER TITLE PAGE DECLARATION DEDICATION ACKNOWLEDGEMENT ABSTRACT ABSTRAK

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

CHAPTER 8 SUMMARY OF PARAMETER SETTINGS

TECHNICAL BULLETIN. Direct Impulse Control for Einstein RX

NX Series Inverters. HVAC Pocket Programming Guide

Motomatic via Bode by Frank Owen, PhD, PE Mechanical Engineering Department California Polytechnic State University San Luis Obispo

Kelba (Australia) Pty Ltd. PA8101S Manual ~ TABLE OF CONTENTS

User s Manual. Model US1000 Digital Indicating Controller Functions. IM 5D1A01-02E 2nd Edition IM 5D1A01-02E

GE420 Laboratory Assignment 8 Positioning Control of a Motor Using PD, PID, and Hybrid Control

Application Note Loop Tuning

Field Devices and Wiring

International Journal of Research in Advent Technology Available Online at:

Model 805 PWM Proportional Valve / Solenoid Driver with Peak and Hold Control Modes

CCD temperature control. CTIO 60 inches Echelle ECH60HF 4.1

Global Water Instrumentation, Inc.

TOSVERT TM VF-nC3 Parameter List

Closed-Loop Speed Control, Proportional-Plus-Integral-Plus-Derivative Mode

Figure 1: Unity Feedback System. The transfer function of the PID controller looks like the following:

vacon nxp arfiff30 user manual generator application ac drives

Transcription:

The MFT B-Series Flow Controller. There are many options available to control a process flow ranging from electronic, mechanical to pneumatic. In the industrial market there are PLCs, PCs, valves and flow meters, all of which are capable of implementing a flow control system. The features on these controllers range from very basic to advanced, with learning curves to match. The MFT B-Series has a very basic built-in flow controller which is manually configured. If a simple local flow control PID loop fits into your application, then this may be all you need. This section describes the setup of the flow control functions, nomenclature and also includes a short tutorial on feedback control systems. Summary of capabilities Control Output 4-20 ma positional signal Fixed output position control for testing in program mode (% of AO range). Fix flow, menu programmed. Modbus write register 4-20 ma input, engineering units scaled. Set Point Register Analog Input Set point Reference Meter 1, Flow Rate Meter PID Manual gain setting. Normalized coefficients P: gain I: time constant D: time constant 360209-O Rev. B Flow Controller O-1

Flow Controller Setup To use the MFT B-Series as an automatic flow controller, you connect one of its 4-20 ma outputs to your control valve, damper or motor controller and it will regulate the flow based on a fixed flow set point value or an analog Input for the set point. The 4-20 ma output can be used as a position command signal for a control valve or motor drive RPM. SP TI FTC GAS The example above has the MFT B-Series flow meter actuating a valve based on an external set point of the flow rate. The second 4-20 ma output channel is sending the flow rate signal elsewhere, although it could be temperature instead of flow rate. PID control of the process is manually configured. The control output may be controlled manually from the LCD display to verify the range operation of the control loop or to manually set the output (control valve) at a fixed position. PID Setup Steps 1. Mechanically mount all components, test for leaks and check flow control actuator motion or motor controller action. 2. Electrically connect all components. Decide which 4-20 ma output will be the control output and wire this in. The default output of the MFT units is for loop powered 4-20 ma. If you need it to be self powered, see the wiring diagrams. 3. Configure the output 4-20 ma scale for the control device using engineering units of velocity or flow rate. You tell the controller in process flow units what the flow rate is at 4 ma output position and 20 ma output position. 4. Configure the set-point source: External analog input. Configure the 4-20 ma scale with the proper engineering units. Internal Set point: a set point (Flow Rate or Velocity) value is entered to maintain the PID control variable (Flow Rate or Velocity) at a fixed value. This set point can be changed at the meter keypad or via a Modbus command. 360209-O Rev. B Flow Controller O-2

5. Tune the control loop for stable operation over the flow range of interest. The setup of the above parameters are done from Program Mode of the Flow meter which are covered next. Setup PID Data Menu Enter Program Mode, by pressing P, the access code (654321), and E. Press 2 to invoke the Quick Jump option entry method and select Option #21, for the Setup PID Data menu. If the screen displays PID FUNCTION IS NOT INSTALLED!! the meter was not purchased with this option. Section I defines each version of the hardware to check if this feature is available for your meter. The meter will prompt to set the PID function ON or OFF. Use the ^ or v key to change the selection to 'ON' then press E to accept the selection. PID STATE >ON ^v The next screen will prompt for the PID mode of operation. The selection can be AUTOMATIC or MANUAL. AUTOMATIC is used for constant flow control which adjusts based on an external or internal set point. MANUAL is used for manual flow control using the PID Manual Control Menu to set the PID Control to a fixed position. PID OPERATION >MANUAL ^v Use the ^ or v key to select the mode of operation and press E to accept the selection or P to skip to the next display. The next screen prompts for the control variable. The selection can be FLOW RATE or VELOCITY. Select FLOW RATE for volumetric and mass flow or VELOCITY for flow velocity. PID CONTROL TO >FLOW RATE ^v 360209-O Rev. B Flow Controller O-3

Use the ^ or v key to select the variable to be controlled. Press E to accept the selection or P to skip to the next display. The next screen prompts for the PID set point reference. The selection can be INTERNAL or EXTERNAL. INTERNAL is selected if the PID variable is controlled with respect to an internal (internally stored in the meter s nonvolatile memory) set point value specified by the user. EXTERNAL is selected if the PID variable is controlled with respect to a measured analog input. PID SETPT REF >INTERNAL ^v Use the ^ or v key to select the PID set point reference. If EXTERNAL is selected, the External Analog Input channel must be assigned to the PID EXT. REF option (Program Mode Option #20). If INTERNAL is selected, the meter will prompt for the set point value. The set point will be in the same units as the CONTROL TO variable selected previously. Use the numeric and decimal keys to enter the PID set point and press E to accept the entry or P to skip to the next display. PID SETPOINT >1234.5600 SCFM The set point value can also be specified using Modbus command 0x06, register 44. The next screens prompt for the PID tuning parameters Proportional Gain, Integral Time Constant, and Derivative Time Constant. The Integral Gain is the Proportional Gain divided by the Integral Time Constant. This linking of the Integral Time Constant with the Proportional Gain makes it easier to manually tune the system. The Derivative Gain is the Proportional Gain multiplied by the Derivative Time Constant. This linking of the Derivative Time Constant with the Proportional Gain makes it easier to manually tune the system. PP GAIN (KP) >0.300 INTEGRAL TC >1.000 SEC DERIVATIVE TC >0.300 SEC 360209-O Rev. B Flow Controller O-4

Use the numeric and decimal keys to enter the PID tuning parameters and press E to accept the entry or P to skip to the next display. The meter next prompts for the PID low (output) limit. This limit is the lowest flow rate or velocity (depends on the CONTROL TO variable selected) that the meter will control to (see the section on 4-20 ma output range for control output in flow units). Its output will saturate 10% below the entered value. The limit will also prevent the integral term wind up or accumulation. Use the numeric and decimal keys to enter a PID Low Limit and press E to accept the entry or P to skip to the next display. PID LOW LIMIT >0.000 SCFM The meter next prompts for the PID high (output) limit. This limit is the highest flow rate or velocity (depends on the CONTROL TO variable selected) that the meter will control to (see the section on 4-20 ma output range for control output in flow units). Its output will saturate 10% above the entered value. The limit will also prevent the integral term wind up or accumulation. Use the numeric and decimal keys to enter a PID High Limit and press E to accept the entry. PID HIGH LIMIT >5000.00 SCFM Pressing E or P will exit out of the Setup PID Data Menu and return to the Program Mode Option Entry screen. Setup for the PID 4-20 ma Control Output The PID control output is a 4-20 ma positional signal. It uses either one of the 4-20 ma analog outputs. An analog output (AO1 or AO2) must be configured to the PID output. The analog output setup is performed in Program Mode as described below. Enter Program Mode by pressing P, the access code (654321), and E. Press 2 to invoke the Quick Jump option entry method and select Option #5 or #6, for the Setup AO1 or Setup AO2 menu, respectively. The following key/display sequences demonstrate setting up Analog Output #2 as the PID output (if the PID output is needed on Analog Output #1, select Option #5 at the Program Mode Option Entry screen) 360209-O Rev. B Flow Controller O-5

The meter will prompt for a function to assign to the analog output. Use the ^ or v key to scroll through the selection list until PID is displayed. Press E to accept PID. ANALOG OUT 2 >PID ^v The meter will next prompt for the analog output signal at 4mA. This is the value of the controlled variable (Flow Rate or Velocity) when the valve or damper is fully closed or the fan is OFF; this value is usually zero. AO1 at 4mA >0.00000000 SCFM Use the numeric and decimal keys to enter a value and press E to accept the entry or P to skip to the next display. The meter will next prompt for the analog output signal at 20mA. This is the value of the controlled variable (Flow Rate or Velocity) when the valve or damper is 100% open or the fan is at full speed (controlled device). AO1 at 20mA >12345.678 SCFM Use the numeric and decimal keys to enter a value and press E to accept the entry. Pressing E or P will exit out of the Setup AO Menu and return to the Program Mode Option Entry screen. Setup for the External Input for PID Remote Reference The PID is controlled from a set point reference. The PID set point reference can be defined as either INTERNAL or EXTERNAL. When the set point reference is INTERNAL, the set point value is specified by the user and stored in the MFT-B. This value can be changed at the meter keypad or can be specified via Modbus. Alternatively, the reference set point can be read from an ANALOG INPUT (4-20mA) signal. When the PID is controlled from an ANALOG INPUT signal, the PID set point reference is configured as EXTERNAL. The Analog Input for the EXTERNAL PID set point is setup in Program Mode as described below. 360209-O Rev. B Flow Controller O-6

Enter Program Mode by pressing P, the access code (654321), and E. Press 2 to invoke the Quick Jump option entry method and select Option #20, for the Setup External Input menu. If the screen displays EXTERNAL INPUT IS NOT INSTALLED the meter was not purchased with this option. Section I defines each version of the hardware to check if this feature is available for your meter. If the meter is factory configured with the external analog input feature, the meter will prompt to assign a function to the External (Analog) Input. EXT. INPUT USAGE >PID EXT. REF ^v Use the ^ or v key to scroll to PID EXT. REF and press E to accept the selection or P to skip to the next display. The next menu items setup the 4-20mA range of the external analog input. The meter first prompts for the External Input value at 4.00 ma. This is the minimum value of the PID set point that can be used. The value is in the same units as the controlled variable configured when the PID was set up (Flow Rate or Velocity). The example below shows a flow meter with the PID controlled variable as the Flow Rate. INP VAL AT 4mA >0.000000 SCFM Use the numeric and decimal key to enter the minimum PID set point and press E to accept the new entry or P to skip to the next display. The meter will next prompt for the External Input value at 20.00 ma. This is the maximum value of the PID set point that can be used. The value is in the same units as the controlled variable configured when the PID was set up (Flow Rate or Velocity). INP VAL AT 20mA >0.000000 SCFM Use the numeric and decimal key to enter the maximum PID set point and press E to accept the new entry or P to skip to the next display. 360209-O Rev. B Flow Controller O-7

The meter will next prompt for the External Input digital filter time constant, the default is 0.5 seconds. FILTER TC >0.500 SEC Use the numeric and decimal key to enter the FILTER TIME CONSTANT and press E to accept the new entry. Pressing E or P will exit out of the Setup External Input Menu and return to the Program Mode Option Entry screen. PID CONTROLLER OPERATION The PID controller can be setup to operate in Automatic or Manual mode. The PID operation is configured in Program Mode using the Setup PID Data menu (Option #21). PID Control in Automatic Mode PID control action will start as soon as the Automatic mode is set in the PID setup menu (in Program mode). The flow rate or velocity is maintained to the PID set point value. The PID control is in the Automatic mode if the PID operation selected is AUTOMATIC. Refer to the section Setup PID Data Menu. PID Control in Manual Mode The PID control is in the Manual mode if the PID operation selected is MANUAL and the PID State is ON. Refer to the section Setup PID Data Menu. The manual control is performed by manually adjusting the PID output or 4-20 ma position signals in Program Mode as described below. Enter Program Mode by pressing P, the access code (654321), and E. Press 2 to invoke the Quick Jump option entry method and select Option #22, for the Manual PID Control menu. If the screen displays PID FUNCTION IS NOT INSTALLED!! the meter was not purchased with this option. Section I defines each version of the hardware to check if this feature is available for your meter. If the screen displays 360209-O Rev. B Flow Controller O-8

PID STATE IS OFF NOT ACTIVE the PID state needs to be turned ON in the Setup PID Data menu (Option #21). If the screen displays PID IS AUTOMATIC SET MANUAL MODE the PID operation needs to be set to MANUAL in the Setup PID Data menu. If the meter is factory configured with the PID function, the PID state is ON, and the PID Operation is set to MANUAL, the meter will display the following prompt for the PID manual control. OUT= 0 PERCENT ^=OPEN v=close Use the ^ key to increase the output and the v key to decrease the output. When 100 percent is displayed, the maximum PID limit equivalent to the maximum output current is reached. When 0 percent is displayed, the minimum PID limit equivalent to the minimum output current is reached. Displaying the PID Remote Reference Reading The External Input reading can be viewed in Display Mode. Enter Display Mode by pressing D and 2 to invoke the Quick Jump option entry method and select Option #41 for the External Input display. The screen will display the following IN= XX.XXX AT YYYY.YY ma SCFM The XX.XXX value is the 4-20mA signal (current) read from the Analog Input and the YYYY.YY value is the equivalent PID reference (Flow Rate or Velocity) at the XX.XXX current level. The mapping of input current to Flow Rate or Velocity is configured in the Set External Input Data menu. Press H to exit from the External Input display and return to the Option Entry screen of Display Mode. Press H again to return to Run Mode. 360209-O Rev. B Flow Controller O-9

PID Tuning. Manual tuning of a PID loop can be done by following the steps listed below. 1. Place the unit in manual control mode or open loop control. Increase or decrease the 4-20 ma output by 5 to 10%. Note the flow response change. Then the Proportion Gain starting point is: 2 x Output change (engineering units)/(flow Response change) (this is a unit less number) Note the system response time (0 to 63% change) to the change. Set the Integral response time to this number. Set the derivative time constant to 1/6 of the integral time. 2. Now place the system in closed loop or automatic operation. Do a small change of the set point and observe how it reacts. Example system responses 3 Over Damped Response Response 2 1 Increase the proportional Gain and reduce the integral time constant. 0 10 5 0 5 10 Time 360209-O Rev. B Flow Controller O-10

3 Critically Damped Response Response 2 1 System tuned just right. Note the parameters and you are done. 0 10 5 0 5 10 Time 3 Under Damped Response Response 2 1 Reduce the proportional gain and increase the integral time constant by the same percentage, say 25%. 0 10 5 0 5 10 Time 3. Some systems require different parameters at different operating points. The best way to handle this is to optimally tune it at the normal flow rate and live with the non-ideal response at the other flow rates. If the variation in loop stability is too large over the normal operating flow ranges, then an advanced PID controller with variable gain settings will be required instead of the built-in flow controller. 360209-O Rev. B Flow Controller O-11