U of I Facilities Standards Updates for 2017

Similar documents
University of Houston Master Construction Specifications Insert Project Name SECTION MECHANICAL SCOPE OF WORK PART 1 - GENERAL

OCPS Submittal Register for Product Data and Shop Drawing Reviews

PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS. room) Scalable bubble diagrams schedules describing programmatic

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Design Deliverables. Summary. A. Expectations for Design Deliverables:

SECTION MECHANICAL IDENTIFICATION

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

SECTION MECHANICAL IDENTIFICATION

Daniel S Wentworth Elementary School

PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

Philip Rogers Elementary School

Excavating, Backfilling, and Compaction for Utilities Piping (Plumbing).

Travis County ESD #1. Building Plan Submittals. Information Bulletin. Fire Marshal Hancock

Charles G Hammond Elementary School 2819 W 21st Pl Chicago, IL 60623

A/E REVIEW CHECKLIST PLUMBING/FIRE PROTECTION/SANITARY

Industrial Pipe Marking

Andrew Carnegie Elementary School

Residential Construction Checklist Single and Two Family Construction

1. State that all workmanship must conform to all pertinent laws, ordinances and regulations of all bodies having jurisdiction.

05BDB ADDENDUM 002. Thomas W. Wathen Business Division Building Renovation GENERAL ITEMS:

BUILDING PLAN REVIEW REQUIREMENTS

ARCHITECTURE CADD Course Syllabus

Johann W von Goethe Elementary School 2236 N Rockwell St Chicago, IL 60647

Morton School of Excellence

Paul Cuffe Math-Science Technology Academy ES 8324 S Racine Ave Chicago, IL 60620

Thomas Chalmers Specialty Elementary School 2745 W Roosevelt Rd Chicago, IL 60608

ADDENDUM #2 September 12, 2018

Facility Services Subgroup Preface for Divisions 21` through 28

Charles N Holden Elementary School

Marcus Moziah Garvey Elementary School

STEM Magnet Academy. Definitions EXTERIOR W Fillmore St Chicago, IL 60607

A/E REVIEW CHECKLIST HVAC

SECTION MECHANICAL IDENTIFICATION

Marcus Moziah Garvey Elementary School S Morgan St Chicago, IL 60643

Arthur E Canty Elementary School

Multicultural Academy of Scholarship

Feedback Systems in HVAC ASHRAE Distinguished Lecture Series Jim Coogan Siemens Building Technologies

SECTION PROJECT COORDINATION VIA BIM

Architecture, Construction, and Engineering Technical Charter

DOCUMENT SUBMITTAL REQUIREMENTS FOR A NEW MULTI-FAMILY DWELLING

SITE $1,539,659. Item - Type Quantity Unit Rank Cost. Entrance Control - Audio and Video 2 EA Exterior Doors - Exterior Wood Door 2 EA

Philip Rogers Elementary School 7345 N Washtenaw Ave Chicago, IL 60645

William H Seward Communication Arts Academy ES 4600 S Hermitage Ave Chicago, IL 60609

Amos Alonzo Stagg Elementary School

John F Kennedy High School

Josefa Ortiz De Dominguez Elementary School 3000 S Lawndale Ave Chicago, IL 60623

Norman A Bridge Elementary School

Rufus M Hitch Elementary School

George Washington Elementary School 3611 E 114th St Chicago, IL 60617

James Shields Middle School 2611 W 48th St Chicago, IL 60632

John Harvard Elementary School of Excellence

Thomas A Edison Regional Gifted Center ES 4929 N Sawyer Ave Chicago, IL Co-locating on this campus are EDISON and ALBANY PARK

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

Friedrich Ludwig Jahn Elementary School 3149 N Wolcott Ave Chicago, IL 60657

University of Chicago Charter - Carter G Woodson

James Monroe Elementary School 3651 W Schubert Ave Chicago, IL 60647

Perspectives - Math and Science Academy 3663 S Wabash Ave Chicago, IL 60653

George Washington High School

Wendell Smith Elementary School

George Washington Elementary School

UTSA Facilities Condition Assessment. Out Brief August XX, 2009

Everett McKinley Dirksen Elementary School

Element Z General Design Requirements Standards and Other Requirements

Franklin Elementary Fine Arts Center 225 W Evergreen Ave Chicago, IL 60610

John Milton Gregory Elementary School

Jackie Robinson Elementary School

John Barry Elementary School 2828 N Kilbourn Ave Chicago, IL 60641

Robert Fulton Elementary School

Heat Exchanger Construction Checklist

John L Marsh Elementary School

Lorenz Brentano Math & Science Academy ES 2723 N Fairfield Ave Chicago, IL 60647

University of Chicago Charter - NKO

Wendell E Green Elementary School 1150 W 96th St Chicago, IL 60643

Disney II Magnet School

SECTION MECHANICAL IDENTIFICATION. 1. Identification of mechanical products installed under Division 15.

SECTION MECHANICAL IDENTIFICATION. 1. Identification of mechanical products installed under Division 15.

George W Tilton Elementary School

Ellen Mitchell Elementary School 2233 W Ohio St Chicago, IL 60612

William Rainey Harper High School 6520 S Wood St Chicago, IL 60636

Marshall Truck Station Laboratory Addition Project No. TZ MnDOT

Joseph Lovett Elementary School 6333 W Bloomingdale Ave Chicago, IL 60639

CPM revision date: 8/5/2018 page 1

KIPP Charter Bloom. Definitions EXTERIOR S Lowe Ave Chicago, IL Co-locating on This Campus: Hope HS and Kipp Chtr Bloom

Alexander Graham Bell Elementary School

John Spry Elementary Community School

Mahalia Jackson Elementary School 917 W 88th St Chicago, IL 60620

William Howard Taft High School

Charles P Caldwell Academy of Math & Science ES 8546 S Cregier Ave Chicago, IL 60617

03/7/12 Issuance UTD Section Page 1 of 5 Electrical General

James Otis Elementary School 525 N Armour St Chicago, IL 60642

John Palmer Elementary School 5051 N Kenneth Ave Chicago, IL 60630

ELECTRICAL GENERAL DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Electrical/Telecommunications Design

Brian Piccolo Elementary Specialty School

Bowen High School. Definitions EXTERIOR E 89th St Chicago, IL Co-locating on This Campus: Bowen HS and Noble St Chtr-Orange

2. Electrical rooms shall be centrally located and stacked so that feeder conduits and bus duct are run as straight and short as possible.

Joseph E Gary Elementary School

University of Chicago - North Kenwood/Oakland 1119 E 46th St Chicago, IL Co-locating on this campus are U OF C - NKO and ARIEL

Emmett Louis Till Math and Science Academy 6543 S Champlain Ave Chicago, IL 60637

Joseph E Gary Elementary School 3740 W 31st St Chicago, IL 60623

Transcription:

U of I Facilities Standards Updates for 2017 Updates to the U of I Facilities Standards will occur on a periodic basis (typically all standards will be reviewed for accuracy & completeness every 3 years), as noted by the LAST UPDATED date in the document footer or title block of a drawing. These updates shall be in force at the time of posting on the U of I Facilities Standards website. Standards in force at the time of an AE signed contract shall apply through the life of the project s contract. For convenience, updates will be incorporated into the main body of the Standards with revisions clearly shown. Notation used in the Updated Documents: Revised File: A vertical line in the margin of a document indicates that the material differs from the previous edition. This material should be reviewed carefully, as some requirements may have changed. Completely Revised File: Occasionally a standard will need to be completely or almost completely revised. There will not be a vertical line in the margin of a document indicating all the changes. The footer date will be updated and the document should be reviewed as a new standard. File: A new file within the General Requirements, General Guidelines, Technical Sections, Exhibits or Drawing Details directory will not have a vertical line. PLEASE REVIEW THE FILES LISTED BELOW FOR THE EDITS THAT HAVE BEEN MADE TO THE STANDARD. Section General Requirements Application of Standards Classroom Lecture Halls General Design Codes, Standards and Regulations Historic Preservation Review Procedures LEED Requirements Requirements for Project Design Calculations Sustainability U OF I FACILITIES STANDARDS Page 1 of 7 LAST UPDATED OCTOBER 1, 2017

General Guidelines Building Elements General Guidelines Building Systems General Guidelines - Sites & Grounds Doors & Windows, Glazing Finishes, Treatments, & Trim, Interior Floors Foundations, Below-Grade Construction Keying Systems & Lockset Functions MEP Space Requirements Service Entrances, Material & Waste Handling Space Calculations for Offices and Classrooms Storm Refuge Areas Chemical Treatment, Water Conditioning Systems Energy Conservation Heating Systems HVAC Systems Hydronic Heating, Cooling Systems Laboratory Ventilation Ventilation Systems Construction Staging Area General Site Civil Requirements Parking Streets, Sidewalks & Bicycle Network Yes Replaced Tornado Shelters ENTIRE SECTION EDITED U OF I FACILITIES STANDARDS Page 2 of 7 LAST UPDATED OCTOBER 1, 2017

General Guidelines - Utilities Division 01 - Administrative Division 08 - Openings (Doors and Windows) Division 11 - Equipment Division 12 - Furnishings Division 21 - Fire Suppression Division 22 - Plumbing Chilled Water Distribution System Water Distribution Systems 01 33 23 - Shop Drawings, Product Data, and Samples 01 35 00 - Special Procedures 01 55 00 - Vehicular Access and Parking 01 56 00 - Temporary Barriers and Enclosures 01 78 23 - Operation and Maintenance Data 01 78 39 - Project Record Documents 08 11 13 - Hollow Metal Doors and Frames 11 53 13 - Chemical Fume Hoods and Biological Safety Cabinets 11 53 53 - Biological Safety Cabinets 12 61 00 - Fixed Audience Seating 21 10 00 - Water-Based Fire-Suppression Systems 22 07 16 - Plumbing Equipment Insulation 22 07 19 - Plumbing Piping Insulation 22 10 00 - Plumbing Piping 22 11 23.13 - Domestic Water Pressure Boosting Systems, VFD 22 13 16 - Sanitary Waste and Vent Piping 22 13 29 - Sanitary and Storm Sewer Pumps 22 40 00 - Plumbing Fixtures 23 05 19 - Meters and Gauges for HVAC Piping U OF I FACILITIES STANDARDS Page 3 of 7 LAST UPDATED OCTOBER 1, 2017

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC) 23 05 93 -Testing, Adjusting and Balancing for HVAC 23 07 13 - Duct Insulation 23 07 16 - HVAC Equipment Insulation 23 07 19 - HVAC Piping Insulation 23 09 13 - Instrumentation and Control Devices for HVAC 23 09 13.33 - Control Valves 23 09 13.34 - Control Valve Actuators 23 09 13.43 - Control Dampers 23 09 23 - Building Automation System (BAS) for HVAC 23 09 43 - Pneumatic Controls for HVAC 23 20 00 - Pipe Joining 23 21 13 - Hydronic Piping 23 21 16 - Hydronic Specialties 23 21 23 - Hydronic Pumps 23 22 13 - Steam and Condensate Piping 23 22 16 - Steam and Condensate Specialties 23 22 23 - Steam Condensate Pumps 23 25 10 - Fluid Filtration 23 34 00 - HVAC Fans 23 36 00 - Air Terminal Units 23 73 13 - Modular Air Handling Units 23 73 23 - Custom AHU 23 82 16 - Air Coils U OF I FACILITIES STANDARDS Page 4 of 7 LAST UPDATED OCTOBER 1, 2017

Division 26 - Electrical 26 05 33 Raceways 26 05 53 - Identification for Electrical Systems 26 09 23 - Lighting Controls 26 11 16 - Secondary Unit Substations 26 22 13 - Transformers 26 23 00 - Low Voltage Switchgear 26 24 13 - Switchboards 26 24 16 - Panelboards 26 27 13 - Electrical Metering 26 29 13 - Motor Control 26 56 00 - Exterior Lighting Division 32 - Exterior 32 13 13 - Sidewalks & Pavers Improvements Division 33 - Utilities 33 63 00 - Tunnel Steam and Condensate Systems Exhibits Drawing Details Exhibit 01 33 23-01 Electronic Construction Submittal Process Exhibit 23 09 23-08a, VAV Box Sequence of Operation Exhibit 23 09 23-09 AHU Standard VAV AHU Sequence of Operation Exhibit 23 09 23-14 Energy Recovery Wheel Standard Sequence of Operation Exhibit 23 09 23-15 Energy Recovery Run Around Coil Standard Sequence of Operation Exhibit 23 09 23-16 Two Pump HTX Sequence of Operation Exhibit 27 40 00-02, AV Basis of Design Drawing 01 58 13-01, Project Site Sign Template Drawing 12 93 53-02, Post and Chain U OF I FACILITIES STANDARDS Page 5 of 7 LAST UPDATED OCTOBER 1, 2017

Variance Process Drawing 23 05 17-01, Pipe Penetration Interior Wall Drawing 23 05 17-02, Pipe Penetration Fire Wall Drawing 23 05 17-03, Pipe Penetration Exterior Wall Drawing 23 05 17-04, Pipe Penetration Floor Drawing 23 09 05-03, Type VAV AHU, Minimum OA, HW Preheat Drawing 23 09 05-11, Steam to Hot Water Heat Exchanger HW System Controls Drawing 23 09 13-01, Differential Pressure Instrumentation-Model Drawing 23 09 13-02, Static Pressure Instrumentation Drawing 23 09 13-03, Central Chilled Water System Metering Station Drawing 23 20 00-01, Central Chilled Water System - Building Service Entrance Drawing 23 21 00-01, Flow Diagram - Hot Water Heating System Drawing 23 21 13-01, Hydronic Air-Dirt Separator Installation Detail Drawing 23 22 00-01, Flow Diagram - Steam Heating Systems Drawing 23 22 00-02, Flow Diagram - Steam PRV and Condensate Return System Drawing 23 25 10-01, Bypass Filtration Piping Detail Drawing 23 36 00-01, Air Terminal Unit Ventilation Connection Drawing 23 36 00-02, Air Terminal Unit Installation Drawing 23 82 16-01, Freeze Protection Thermostat Installation Drawing 26 56 00-02, Pedestrian Area Light Installation Drawing 26 56 00-03, Parking Lot Light Installation Drawing 32 13 13-01, Concrete Sidewalk Installation Drawing 32 17 23-02, Motorcycle Parking, Single Loaded Bay Drawing 33 05 23-01, Utility Requirements Under Tree Root Zones Variance Approval Request Form U OF I FACILITIES STANDARDS Page 6 of 7 LAST UPDATED OCTOBER 1, 2017

Variance Rejection Appeal Form Variances U OF I FACILITIES STANDARDS Page 7 of 7 LAST UPDATED OCTOBER 1, 2017