Pen-type DIGITAL MULTITESTER

Similar documents
ET-3888 True RMS Clamp Meter. User Manual

EARTH RESISTANCE TESTER

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

8PK-ST1520 Digital Earth Resistance Tester

R/C SMD Tweezers Multimeter Model RC200

CONTENTS MS2033A. 1.Introduction Safety Information...01

User Manual 4 wire Earth Resistance Tester Model GRT300

AMM-1022 Digital Multimeter USER`S MANUAL

AC/DC CLAMP METER USER S MANUAL

User Guide. 4 wire Earth Resistance Tester Model GRT Washington Street Melrose, MA Phone Toll Free

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

KMD-S04 Multímetro de bolsillo

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

Digital Multimeter, Pen Type

OPERATOR S INSTRUCTION MANUAL

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

OPERATOR S INSTRUCTION MANUAL

Multifunction Digital

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

Item ref: UK MTM01 DIGITAL MULTITESTER. User Manual

USER'S MANUAL DMR-6700

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

Digital Clamp Meter (TRMS) Model : 2727

User Guide. Digital AC/DC Clamp Meter Model 38394

Mini Clamp Meter Model:

User s Guide. Digital AC/DC Clamp Meter Model 38394

DIGITAL MULTIMETER AUTORANGING

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

INSTRUCTION MANUAL IDM17 PEN-TYPE MULTIMETER

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

User Manual Digital Clamp Multimeter. model no.: MSR-C600

Model UT10A: OPERATING MANUAL Table of Contents (1)

DVM1190 DIGITAL MULTIMETER

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

Pen Multimeter. Model

UT207A/208A/209A Operating Manual. Table of Contents

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

NOTE: Fully read and understand this manual before using this Digital Multimeter.

AM

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

MS2030 CAT III 600 V A V AUTO RS232

Autoranging Multimeter Extech EX503

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

USER S MANUAL DMR-1500

INSTRUCTION MANUAL DIGITAL MULTIMETER

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

USER'S MANUAL DMR-4300

DMM8900 SERIES USERS MANUAL

DM-45 Digital Multimeter

Model : OPERATING MANUAL Table of Contents (1)

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

Table of Contents Title Page

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

Digital Multimeter with Backlight

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

Digital Clamp Meter. User Manual

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

ACA LEAKAGE TESTER OPERATION MANUAL. auto range, true rms. Model : DL-9954

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

200Amp AC Clamp Meter + NCV Model MA250

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

USER'S MANUAL DMR-4350

ATK Clamp Meter

400Amp True RMS AC Clamp Meter + NCV

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Digital Clamp Meter Model: &

400Amp True RMS AC/DC Clamp Meter Model EX613

Model DIGITAL MULTIMETER

600A Clamp Meters w/tightsight Display

M-1000D DIGITAL MULTIMETER

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Data sheet IDM 99III Digital Multimeter

2,000 counts, 200 Amp ACA/DCA, 600 V ACV/DCV, True RMS, OHMS, Continuity, Hold, Peak Hold FORK CURRENT TESTER. Model : FT-9950

MT /6 Smart Digital Clamp Meter. User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd.

MS8216 DIGITAL MULTIMETER OPERATOR S MANUAL

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

Data sheet IDM 98III Digital Multimeter

User Manual Digital Multimeter

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

MS8223A. CAT.IIi 600 V

MS2109A AC/DC Clamp Meter. User Manual. Contents

Model UT201/202: OPERATING MANUAL. Table of Contents

True RMS Digital Multimeter Model:

BM22s, BM25s, BM25a & BM27s USER'S MANUAL

Transcription:

BST-MT267 Pen-type DIGITAL MULTITESTER INSTRUCTION MANUAL

Index 1. Introduction... 2. Safety Notes... 3. Features... 4. Specifications... 5. General... 6. Instrument Layout... 7. Measurement... 8. Maintenance... 9. Fuse Replacement... Page 1 1-2 2-3 3-4 4-5 5-7 8-9 9-10 10

1. Introduction NOTE This meter has been designed and tested According to CE Safety Requirements for Electronic Measuring Apparatus, IEC / EN 61010-1 and other safety standards. Follow all warnings to ensure safe operation. WARNING READ "SAFETY NOTES" (NEXT PAGE) BEFORE USING THE METER. 2. Safety Notes Read the following safety information carefully before attempting to operate or service the meter. Use the meter only as specified in this manual. Otherwise, the protection provided by the meter may be impaired. Rated environmental conditions : (1) Indoor Use. (2) Installation Category III. (3) Pollution Degree 2. (4) Altitude up to 2000 meters. (5) Relative humidity 80% max. (6) Ambient temperature 0 C~40 C. -1-

Observe the International Electrical Symbols listed below : Meter is protected throughout by double insulation or reinforced insulation. Warning! Risk of electric shock. Caution! Refer to this manual before using the meter. AC... Alternating current. DC... Direct current. 3. Features 4000 - count LCD. Full automatic measurement. Voltage measurement. Resistor measurement. Data Hold function. Continuity check. Diode measurement. Low battery indication. Pen light provided. Back light LCD. 3V DC power supply. -2-

Input impedance : 10MΩ Safety Standard : EN 61010-1 CAT III 600V EN 61326-1 : 2006 IEC 61000-4-2 IEC 61000-4-3 CISPR11 4. Specifications (All at 23 C±5 C, 80%R.H) AC Voltage Range Resolution Accuracy 4 V 1 mv 40 V 10 mv 400 V 100 mv ± (1.5% rdg+5dgt) 600 V 1 V Input impedance : 10MΩ DC Voltage Range Resolution Accuracy 4 V 1 mv 40 V 10 mv 400 V 100 mv ± (1% rdg+3dgt) 600 V 1 V Input impedance : 10MΩ -3-

Resistance Range Resolution Accuracy 400 Ω 0.1 Ω 4 KΩ 1 Ω 40 KΩ 10 Ω ± (1.5% rdg+3dgt) 400 KΩ 100 Ω 4 MΩ 1 KΩ 40 MΩ 10 KΩ ± (2.5% rdg+4dgt) Overload Protection 500V DC Continuity Test Range Audible threshold 400 Ω Less than 25 Ω 4. General Dimensions : 196mm(L) x 35.8mm(W) x 28.3mm(D) Weight : Approx. 105g (battery included) Power source : CR2032 battery 3V x 1 Low Battery Indication : "BATT" sign appears on the display when the battery voltage drops below accurate operating level. -4-

Accessories : Battery Soft pouch Instruction Manual Probe mounting fixture 6. Instrument Layout (7) (9) (4) (5) (10) (2) (6) (8) (3) (1) (1) Function Selection Switch (6) LED Light (2) LCD Display (7) Red Test Pin (+) (3) Select Button (8) Black Test Lead (-) (4) HOLD Button (9) Cap (5) Back Light Button (10) Fixture -5-

(1) Function selection switch The function selection switch selects the function. (2) LCD Display 3999 count LCD with LOW BATTERY indication. (3) Select Button For AC/DC function selection. In the resistance + continuity + diode function, press the Select button to select resistance, continuity or diode function. (4) HOLD Button Press the HOLD button (HOLD annunciator turns on) to make the meter stop updating the LCD display. This mode can be nested in most of the special modes. Enabling HOLD function in automatic mode makes the meter switch to manual mode, but the full scale range remains the same. HOLD function can be cancelled by changing the measurement mode, pressing range, or push HOLD again. (5) Pen Light / Back Light Button ON : Press the pen light / back light button. The pen light and LCD backlight will light. OFF : The lights will be off automatically in about 50 seconds. If you press the button when the lights are on, the lights will be off as well. -6-

(6) LED Light For penlight function in dark place. (7) Red Test Pin (+) Red Test Pin for positive polarity connection. (8) Black Test Lead (-) Black test lead (-) negative polarity connection. (9) Cap For protection of the tip of the red test pin. (10) The fixture of the black test lead The fixture is used to fix the black test lead for testing. -7-

7. Measurement Before proceeding with measurement, read the safety notes. (1) Voltage measurement Switch to V function for ACV or DCV function. Use the test lead tip to the circuit and read the reading of display directly. If the readings exceed AC 600V(DC 600V), maybe the reading value is wrong and it is dangerous. (Refer to the safety notes) (2) Resistance Measurement Switch to OHM range and make sure there is no power in the circuit being measured. Insert the Connect the test leads to the circuit or device under test and read the display directly. (3) Continuity Check Continuity check shares the same configuration with 400.0Ω manual resistance measurement mode, but with buzzer output to indicate continuity. The buzzer generates a 2KHz sound whenever the digit number less than 25Ω. Because the cycle time of measurement is only 50ms, the least significant digit will not display. -8-

(4) Diode Measurement Diode measurement mode shares the same configuration with 4.000V manual voltage measurement mode. If the test circuit is open or the voltage drop between the two ports of the device (diode) under test are larger than 2V, the LCD panel will show "OL". The buzzer generates a 2KHz sound whenever the digit number is less than 0.25V. Because the cycle time of measurement is only 50ms, the least significant digit will not display. 8. Maintenance Battery replacement When low battery warning appears, change new battery as follows : (1) Disconnect the test leads from the instrument and turn off power. (2) Unscrew the case and replace new battery. (3) Close the case and lock the screw. -9-

Cleaning and Storage WARNING To avoid electrical shock or damage to the meter, Do not get water inside the case. Periodically wipe the case with a damp cloth and detergent. Do not use abrasives or solvents. If the meter is not used for over 60 days, remove the battery for storage. 9. Fuse Replacement Only replace with the same specification fuse. -10-