Item ref: UK MTM01 DIGITAL MULTITESTER. User Manual

Similar documents
Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

INSTRUCTION MANUAL DIGITAL MULTIMETER

NOTE: Fully read and understand this manual before using this Digital Multimeter.

OPERATOR S INSTRUCTION MANUAL

Digital Multimeter with Backlight

AMM-1022 Digital Multimeter USER`S MANUAL

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

M-1000D DIGITAL MULTIMETER

DMM8900 SERIES USERS MANUAL

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

Table of Contents Title Page

KMD-S04 Multímetro de bolsillo

Model DIGITAL MULTIMETER

AUTO RANGING DIGITAL MULTIMETER

Model : OPERATING MANUAL Table of Contents (1)

User Manual Digital Multimeter

User Manual Digital Multimeter. model no.: MSR-U1000

DVM1190 DIGITAL MULTIMETER

UT207A/208A/209A Operating Manual. Table of Contents

3B SCIENTIFIC PHYSICS

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

DIGIT & POINTER MULTIMETER

Model UT10A: OPERATING MANUAL Table of Contents (1)

Digital Clamp Meter Model: &

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

Digital Multimeter AX-572. Instruction manual

Model UT20B: OPERATING MANUAL Table of Contents (1)

Pocket Size Digital Multimeter Models: and

Model UT39A/B/C: OPERATING MANUAL

Internetowy sklep elektroniczny. Kontakt. Tel Tel. Kom Fax

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

VC835 DIGTAL MULTIMETER Operation Manual

AC/DC CLAMP METER USER S MANUAL

DIGITAL MULTIMETER AUTORANGING

DIGITAL MULTIMETER INSTRUCTION MANUAL

Table of Contents GDM-356. Page

Sales: Technical: Fax:

Model UT201/202: OPERATING MANUAL. Table of Contents

DIGITAL MULTIMETER AX-588B

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

MS8223A. CAT.IIi 600 V

DIGITAL MULTIMETER OPERATING INSTRUCTIONS MODEL CDM-35. Part No

UT132 Series Manual. UT132 Series. Palm Size Digital Multimeter. Operating Manual -1-

Pen-type DIGITAL MULTITESTER

METRAVI. Table of Contents

Model: &

Model UT50D: OPERATING MANUAL. Table of Contents

ProfiScale MULTI Multimeter

The Meter Structure The Figure 2-1 shows the Meter structure.

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

Digital Multimeter, Pen Type

HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

USER'S MANUAL DMR-6700

Digital Multi Meter OPERATING INSTRUCTION. Table of Contents

OS-81B TECPEL CO. LTD.

312, 316, 318. Clamp Meter. Users Manual

True RMS Digital Multimeter Model:

User Guide. Digital AC/DC Clamp Meter Model 38394

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

User Manual. All rights reserved. Specifications are subject to change without notice.

Analog Technologies VC99. Multimeter FEATURES

User s Guide. Digital AC/DC Clamp Meter Model 38394

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Handheld Digital Multimeter PRO-50A

SAFETY PRECAUTIONS: Before use, read the following safety precautions

INSTRUCTION MANUAL MODEL 21 MULTI-TESTER

MS8216 DIGITAL MULTIMETER OPERATOR S MANUAL

UT207/208. Digital Clamp Multimeter P/N:

Title Page Overview Unpacking Inspection Safety Information

R/C SMD Tweezers Multimeter Model RC200

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

770E DIGITAL MULTIMETER OPERATOR S MANUAL

DIGITAL MULTIMETER. MODEL CDM-50 Part No OPERATING INSTRUCTIONS

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL. Table of Contents

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

User Manual Digital Clamp Multimeter. model no.: MSR-C600

OPERATING INSTRUCTION

RAGU 81D DIGITAL MULTIMETER OPERATION MANUAL

Accuracy : ± (0.8% rdg + 1dgt) on all ranges except Ranges : 200mV, 2V, 20V, 200V, 1000V

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

AVM360 Analog multimeter OPERATION MANUAL GEBRUIKERSHANDLEIDING MANUEL D UTILISATEUR

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

User Manual. All rights reserved. Specifications are subject to change without notice.

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.

CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

Handheld Digital Multimeter

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

MANUAL DE INSTRUÇÕES DO MULTÍMETRO DIGITAL MODELO MD-6456 Inglês

ET-3888 True RMS Clamp Meter. User Manual

Transcription:

Item ref: 600.100UK MTM01 DIGITAL MULTITESTER User Manual

Please read this manual thoroughly and ensure all contents are fully understood before using the apparatus. Warning To avoid possible electric shock or personal injury, and to avoid possible damage to the tester or to the equipment under test, adhere to these following rules: Before using the tester inspect the case. Do not use the tester if it is damaged or the case (or part of the case) is removed. Look for cracks or missing plastic. Pay attention to the insulation around the connectors. Inspect the test leads for damaged insulation or exposed metal. Check the test leads for continuity. Do not apply more than the rated voltage, as marked on the tester, between the terminals or between any terminal and grounding. The rotary switch should be in the right position and no changeover of range shall be made while measurement is conducted to prevent damage. When the tester is working at an effective voltage over 60V in DC or 30Vrms in AC, special care should be taken for there is danger of electric shock. Use the proper terminals, function, and range for your measurements. Do not use or store the tester in an environment of high temperature, humidity, explosive, flammable, damp or of a strong magnetic field. The performance of the tester may deteriorate after being exposed to any of these elements. When using the test leads, keep your fingers behind the finger guards. Disconnect circuit power and discharge all high-voltage capacitors before testing resistance, continuity, diodes.

Replace the battery as soon as the battery indicator appears. With a low battery, the meter may produce false readings that can lead to electric shock and personal injury. Remove the connection between the testing leads and the circuit being tested, and turn the meter power off before opening the meter case. The internal circuit of the meter shall not be altered at will to avoid damage of the meter and any accident. A soft cloth and mild detergent should be used to clean the surface of the tester on a regular basis. No abrasive and solvent should be used to prevent the surface of the tester from corrosion or damage. The tester is suitable for indoor use only. Turn the tester power off when it is not in use and take out the battery when not using for a long time. Check the battery regularly; replace the battery immediately if any signs of leaking appear. Battery acid will damage the tester. General Specifications Max display: LCD (1999 count) 67 x 42mm Polarity: Automatic, indicated minus, assumed plus Measure method: double integral A/D switch implement Sampling speed: 2 times per second Over-load indication: 1 is displayed Operating Environment: 0ºC-40ºC, at <80%RH Storage Environment: -10ºC-50ºC, at <85%RH Power: 9Vdc (1 x PP3 battery supplied) Low battery indication: Dimensions: 190 x 90 x 33mm Weight: 190g (including battery)

LCD Power Button HOLD Button Range switch A/mA terminal 10A terminal COM terminal VΩ terminal Multi-function adapter

Multitester comparison table Model DCV ACV DCA ACA Ω hfe Cap MTP01 Y Y Y Y Y Y Y Y Y Technical Specifications Accuracies are guaranteed for 1 year, 23ºC ± 5ºC, less than 80% RH. DC Voltage RANGE RESOLUTION ACCURACY 200mV 100uV ± (0.5% of rdg + 3D) 2V 1mV 20V 10mV ± (0.8% of rdg + 5D) 200V 100mV 600V 1V ± (1.0% of rdg + 5D) Input Impedance: 10MΩ Overload Protection: 1000V DC or 750V AC rms Max. Input voltage: 1000V DC AC Voltage RANGE RESOLUTION ACCURACY 200V 100mV ± (2.0% of rdg + 10D) 500V 1V ± (2.0% of rdg + 10D) Input Impedance: 10MΩ Frequency Range: 40Hz ~ 400Hz Overload Protection: 1000V DC or 750V AC rms Response: Average, calibrated in rms of sine wave Max. Input voltage: 750V AC rms

Audible Continuity RANGE DESCRIPTION Remark Built-in buzzer sounds if resistance is less than 30±20Ω Open circuit voltage: about 2.8V The approximate forward voltage drop will be displayed Open circuit voltage: about 2.8V Overload Protection: 250V DC/AC rms DC Current RANGE RESOLUTION ACCURACY 2mA 1uA ± (1.8% of rdg + 2D) 20mA 10uA 200mA 100uA ± (2.0% of rdg + 2D) 10A 10mA ± (2.0% of rdg + 10D) Overload Protection: ma: F0.5A/600V fuse 10A: F10A/600V fuse Voltage Drop: 200mV AC Current RANGE RESOLUTION ACCURACY 2mA 1uA ± (2.0% of rdg + 2D) 20mA 10uA 200mA 100uA ± (2.0% of rdg + 2D) 10A 10mA ± (2.5 of rdg + 10D) Overload Protection: ma: F0.5A/600V fuse (DT9205A, DT9207A, DT9208A) 10A: F10A/600V fuse Voltage Drop: 200mV Frequency Range: 40Hz ~ 400Hz Response: Average, calibrated in rms of sine wave

Resistance RANGE RESOLUTION ACCURACY 200Ω 0.1Ω ± (1.0% of rdg + 10D) 2KΩ 1Ω 20kΩ 10Ω ± (1.0% of rdg + 4D) 200kΩ 100Ω 2MΩ 1kΩ 20MΩ 10kΩ ± (1.0% of rdg + 10D) 200MΩ 100kΩ ±[5%*(rdg-10) + 10D) Open Circuit Voltage: about 3V Overload Protection: 250V DC/AC rms Capacitance RANGE RESOLUTION ACCURACY 2nF 1pF 20nF 10pF 200nF 100pF ± (4.0% of rdg + 5D) 2uF 1nF 20uF 10nF Overload Protection: F0.5A/600V fuse Over-load protect: 250V DC/AC rms

OPERATING INSTRUCTIONS VOLTAGE MEASUREMENT 1. Connect red test lead to VΩ jack, black lead to COM jack. 2. Set RANGE switch to desired VOLTAGE position, if the voltage to be measured is not known beforehand, set switch to the highest range and reduce it until satisfactory reading is obtained. 3. Connect test leads to device or circuit being measured. 4. Turn on power of the device or circuit being measured voltage value will appear on Digital Display along with the voltage polarity. Please note: In small range, the meter may display an unstable reading when the test leads have not been connected to the load to be measured. It is normal and will not affect the measurements. When the meter shows the over range symbol 1, a higher range must to be selected. To avoid damage to the meter, don t measure a voltage which exceeds 600Vdc (for DC voltage measurement) or 600Vac (for AC voltage measurement). CURRENT MEASUREMENT 1. For reading less than 200mA connect red lead to ma and black lead to COM (for measurements between 200mA and 10A, connect red lead to 10A ) ensure jacks are fully depressed.

2. Set the range switch to desired AC or DC position. If the current magnitude to be measured is not known beforehand, set the ranges switch to the highest range position and then reduce it range by range until satisfactory resolution is obtained. 3. Open the circuit to be measured, and connect test leads in SERIES with the load in with current is to measure. 4. Current reading will be displayed on LCD, for DC current measurement, the polarity of the red probe will also be indicated. Please note: When the display shows the over range symbol 1, a higher range must be selected. In addition 10A function is designed for intermittent use only. RESISTANCE MEASUREMENT 1. Connect red lead to VΩ, black lead to COM. 2. Set the range switch to desired Ω range. 3. If the resistance being measured is connected to a circuit, turn off power and discharge all capacitors before measurement. 4. Connect test leads to circuit being measured. 5. Read resistance value on Digital Display. Please note: For resistance measurements >1MΩ, the meter may take a few seconds to stabilize reading. This is normal for high-resistance measurement. When the input is not connected, i.e. at open circuit, the symbol 1 will be displayed as an over range indicator.

CAPACITY MEASUREMENT 1. Connect the BLACK test lead to the COM jack and the RED to the ma jack. 2. Set the Range switch at F position. (NOTE: The polarity of the RED lead is positive + ) 3. Connect test leads across the capacitor under measure and be sure the polarity of connection is observed. Please Note: To avoid damage to the Meter, disconnect circuit power and discharge all high-voltage capacitors before measuring capacitance. The tested capacitor should be discharged before the testing procedure. Never apply voltage to the input, or serious damage may result. CONTINUITY TEST 1. Connect the BLACK test lead to the COM jack and the RED to the VΩ jack (Note: The polarity of the red test lead is positive + ). 2. Set the range switch to range 3. Connect the test leads across the load to be measured. 4. If the circuit resistance is lower than about 30±20Ω, the builtin buzzer will sound. DIODE MEASUREMENT 1. Connect red lead to VΩmA, black lead to COM. 2. Set RANGE switch to position. 3. Connect the red test lead to the anode of the diode to be measured and black test lead to cathode.

4. The meter will show the approximate forward voltage of the diode. If the connections are reversed, 1 will be shown on the display. TRANSISTOR hfe MEASUREMENT 1. Set the range switch to hfe range. 2. Connect the adapter to the COM jack and the hfe jack. Don t reverse the connection. 3. Identify whether the transistor is NPN or PNP type and locate Emitter, Base and Collector lead. Insert the leads of the transistor to be tested into the proper holes of the transistor test socket of the adaptor. 4. LCD display will show the approximate hfe value. BATTERY AND FUSE REPLACEMENT 1) Battery and fuse replacement should only be done after the test leads have been disconnected and power is off. 2) Loosen screws with suitable screwdriver and remove case bottom. 3) The meter is powered by a single 9V PP3 battery. Snap the battery connector leads to the terminals of a new battery and reinsert the battery into the case top. Dress the battery leads so that they will not be pinched between the case bottom and case top. 4) The meter is protected by fuse: A) ma: F0.5A/600V Fast, Breaking capacity is 10KA, dimensions are 20 x 5mmØ. B) 10A: F10A/600V Fast, Breaking capacity is 10KA, dimensions are 20 x 5mmØ.

Replace the case bottom and reinstall the three screws. Never operate the meter unless the case bottom is fully closed. ACCESSORIES Instruction manual Set of test leads (red and black) 9V PP3 battery EN61010 1:2010 This product is classed as Electrical or Electronic equipment and should not be disposed with other household or commercial waste at the end of its useful life. The goods must be disposed of according to your local council guidelines. Errors and omissions excepted. Copyright 2014. AVSL Group Ltd.