Imaging Beyond the Basics: Optimizing Settings on the Leica SP8 Confocal

Similar documents
Confocal imaging on the Leica TCS SP8. 1) Turn the system on. 2) Use TCS user account. 3) Start LAS X software:

Leica TCS SP8 Quick Start Guide

Supplemental Method Information Zeiss LSM710

Leica TCS SP8 Quick Start Guide

3 Choose the Channels button and set the Channel Settings. Set the Pinhole to 1 Airy unit.

Cell Biology and Bioimaging Core

Leica SP8 TCS Users Manual

1 Set up the confocal light path for imaging a green dye (Alexa488-EGFP). For example, the

Quick Start Guide. Leica SP5 X

Leica Sp5 II Confocal User Guide

Training Guide for Leica SP8 Confocal/Multiphoton Microscope

Leica SP8 Resonant Confocal. Quick-Start Guide

Leica SPEII confocal microscope. Short Manual

Imaging Retreat - UMASS Customized real-time confocal and 2-photon imaging

Things to check before start-up.

Operating Checklist for using the Laser Scanning Confocal Microscope. Leica TCS SP5.

Microscopy from Carl Zeiss

Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009

LSM 710 Confocal Microscope Standard Operation Protocol

Usermanual for Leica SP8 confocal

Why and How? Daniel Gitler Dept. of Physiology Ben-Gurion University of the Negev. Microscopy course, Michmoret Dec 2005

BASICS OF CONFOCAL IMAGING (PART I)

Training Guide for Carl Zeiss LSM 510 META Confocal Microscope

Zeiss 780 Training Notes

Zeiss LSM 510 Confocor III Training Notes. Center for Cell Analysis & Modeling

Nikon A1Rsi Confocal Start-Up Sequence

TRAINING MANUAL. Olympus FV1000

LEICA TCS SP5 AOBS TANDEM USER MANUAL

Zeiss 880 Training Notes Zen 2.3

The Zeiss AiryScan System, Confocal Four.

Training Guide for Carl Zeiss LSM 880 with AiryScan FAST

Guide to Confocal 5. Starting session

ScanArray Overview. Principle of Operation. Instrument Components

Akinori Mitani and Geoff Weiner BGGN 266 Spring 2013 Non-linear optics final report. Introduction and Background

Supplemental Figure 1: Histogram of 63x Objective Lens z axis Calculated Resolutions. Results from the MetroloJ z axis fits for 5 beads from each

Training Guide for Carl Zeiss LSM 5 LIVE Confocal Microscope

Multifluorescence The Crosstalk Problem and Its Solution

LSM 780 Confocal Microscope Standard Operation Protocol

Practical work no. 3: Confocal Live Cell Microscopy

Contents. Introduction

Non-Descanned FLIM Detection in Multiphoton Microscopes

Boulevard du Temple Daguerrotype (Paris,1838) a busy street? Nyquist sampling for movement

Confocal Microscopy. (Increasing contrast and resolu6on using op6cal sec6oning) Lecture 7. November 2017

Leica SP8 TCS Users Manual

Nikon A1R. Multi-Photon & Laser Scanning Confocal Microscope. Kyle Marchuk Adam Fries Jordan Briscoe Kaitlin Corbin. April 2017.

Quick Guide. LSM 5 MP, LSM 510 and LSM 510 META. Laser Scanning Microscopes. We make it visible. M i c r o s c o p y f r o m C a r l Z e i s s

ZEISS LSM510META confocal manual

Renishaw InVia Raman microscope

ZEISS LSM 710 NLO Multiphoton microscope Manual/Quick guide

Confocal Application Letter No. 13. Sequential Scan for Leica TCS NT/SP systems

1 Co Localization and Working flow with the lsm700

Nikon AZ100. Laser Scanning Macro Confocal Microscope. Jordan Briscoe Adam Fries Kyle Marchuk Kaitlin Corbin. May 2017.

Basics of confocal imaging (part I)

Development of a Next-Generation Laser-Scanner System for Life Science Research

Zeiss LSM 880 Protocol

Zeiss LSM 780 Protocol

Confocal Microscopy. Kristin Jensen

PZ-FLIM-110. Piezo Scanning FLIM System. Based on bh s Megapixel FLIM Technology. Complete FLIM Microscopes FLIM Upgrades for Existing Microscopes

DCS-120. Confocal Scanning FLIM Systems. Based on bh s Multidimensional Megapixel FLIM Technology

University of Wisconsin Chemistry 524 Spectroscopic Components *

Point Spread Function. Confocal Laser Scanning Microscopy. Confocal Aperture. Optical aberrations. Alternative Scanning Microscopy

User Guide to the IBIF Leica TCS SP8 MP Confocal Microscope

Olympus LEXT OLS 4000 Confocal Laser Microscope

Locating Molecules Using GSD Technology Project Folders: Organization of Experiment Files...1

Confocal, hyperspectral, spinning disk

ZEISS LSM 710 CONFOCAL MICROSCOPE USER MANUAL

Opterra II Multipoint Scanning Confocal Microscope. Innovation with Integrity

Operating Instructions for Zeiss LSM 510

OPERATING INSTRUCTIONS

Spectroscopy in the UV and Visible: Instrumentation. Spectroscopy in the UV and Visible: Instrumentation

Title: Leica SP5 Confocal User Manual

Examination, TEN1, in courses SK2500/SK2501, Physics of Biomedical Microscopy,

Components of confocal and two-photon microscopes

Improving Image Quality on the UACC Leica SP5 confocal

(Quantitative Imaging for) Colocalisation Analysis

TRAINING MANUAL. Multiphoton Microscopy LSM 510 META-NLO

Zeiss LSM880 Operating Instructions. UTMB Optical Microscopy Core Jan. 16, 2018

NIS-Elements C (For CONFOCAL MICROSCOPE A1) Instructions (Ver. 4.40)

Topics. - How to calibrate the LSM scanner. - How to clean the microscope. - How to adjust the pinhole alignment. - How to adjust the Collimator

Confocal Application Notes Vol. 5 July 2010

ADVANCED METHODS FOR CONFOCAL MICROSCOPY II. Jean-Yves Chatton Sept. 2006

GenePix Application Note

Non-Linear Optical Flow Cytometry Using a Scanned, Bessel Beam Light-Sheet

Swept-Field User Guide

LSM 510 META in Chang Gung University

DCS-120. Confocal Scanning FLIM Systems. Based on bh s Multidimensional Megapixel FLIM Technology

Overview. About other software. Administrator password. 58. UltraVIEW VoX Getting Started Guide

Observational Astronomy

LSM 510 Training Notes

Zeiss LSM 510 Multiphoton Confocal Microscope

MIF ZEISS LSM510 CONFOCAL USER PROTOCOL

Operation Of The Leica SP8 Multiphoton Confocal System Using Single Or Multiple Fluorochromes

Rates of excitation, emission, ISC

CHAPTER 7. Components of Optical Instruments

Multi-channel imaging cytometry with a single detector

Spectral Imaging with the Opterra Multipoint Scanning Confocal

Instructions for the Experiment

Nikon. King s College London. Imaging Centre. N-SIM guide NIKON IMAGING KING S COLLEGE LONDON

TCSPC at Wavelengths from 900 nm to 1700 nm

Nikon Eclipse Ti A1-A Confocal Operating Manual. Start-up. Microscope

Transcription:

Imaging Beyond the Basics: Optimizing Settings on the Leica SP8 Confocal

Todays Goal: Introduce some additional functionalities of the Leica SP8 confocal HyD vs. PMT detectors Dye Assistant Scanning By Frame vs. By Line Bi directional and resonant scanning Optimizing resolution and pixel size Using the Histogram and QuickLUT Linear Z compensation

Spectral Detection with the Leica SP8 Light emitted from the sample passes through a prism There are 5 detectors in the scan head Movable slits and mirrors in front of the detectors determine what wavelengths are captured

PMT vs. HyD Detectors Photomultiplier tubes (PMT): Detectors 1,2,3,5 Hybrid Detector (HyD) Detector 4: Convert photons to photoelectrons Low sensitivity (30% QE) Inexpensive Cross between PMT and APD More sensitive (45% QE) Use for low light applications Lower Noise Expensive Can be damaged

Using the HyD Detector on the SP8 Auto shutoff will engage if HyD is exposed to too much light Start with low laser power and gain Gain is in % (not V)

Dye Assistant A wizard to help you configure the excitation and detection settings quickly Pick a dye Pick a color Pick a detector

Dye Assistant A wizard to help you configure the detector quickly Simultaneous scan Sequential : 2 scans crosstalk speed Apply the detector settings you want Sequential : 3 scans

Dye Assistant Note The Wizard will choose the 496 nm laser for Alexa 488 While 496 nm is closer to the actual excitation peak of Alexa 488.The 488 nm laser is much stronger You will have to manually choose 488 nm excitation for this channel

Scanning Sequentially By Line Scans 1 line of each channel, one after the other All channels will appear to be captured simultaneously Wavelength sliders cannot move between channels during this type of scan NO MOVING PARTS Fastest method of sequential scanning Slightly less photon efficient than By Frame

All wavelength slider positions must not change between sequences

Scanning Sequentially By Frame Scans entire image of one channel before moving to the next channel All channels will be captured one by one Wavelength sliders can move between frames during this type of scan MOVING PARTS Slowest method of sequential scanning More range/flexibility in setting emission bandwidth, more photon efficient One application would be to use the HyD detector for multiple channels

Wavelength slider positions can be changed between sequences

Acquisition Speed Comparison 400 lps scan speed 512 x 512 pixels 3 channels 10 um z range, 30 planes By Frame By Line 3 min 46 sec 1 min 52 sec Between Stacks not recommended

Bi Directional Scanning Capture is usually done in only one direction of the beam scan Imaging can also be done on the return pass of the beam 2X as fast Reverses the direction in which pixels are recorded Alignment of the scan phase is needed

The Control Panel dials can be configured to control Phase

Acquisition Speed Comparison 400 lps scan speed 512 x 512 pixels 3 channels 10 um z range, 30 planes By Frame By Line By Line + Bidirectional 3 min 46 sec 1 min 52 sec 56 sec

Resonant Scanning for large samples The excitation beam is usually raster scanned by the movement of galvanometer driven mirrors flexible scan speeds but slow These can be replaced by faster resonant scanning mirrors which oscillate more rapidly, fast but fixed scan speed Select Resonant On at Startup Resonant Mirror

Scan speed is fixed at 8000 lps

Line accumulations help image quality

Acquisition Speed Comparison 400 or 8000 lps scan speed 512 x 512 pixels 3 channels 10 um z range, 30 planes By Frame By Line By Line + Bidirectional By Line + Resonant* 3 min 46 sec 1 min 52 sec 56 sec 17 sec *w/3 line accumulations

Combining By Line + Resonant + Bi directional

Acquisition Speed Comparison 400 or 8000 lps scan speed 512 x 512 pixels 3 channels 10 um z range, 30 planes By Frame By Line By Line + Bidirectional By Line + Resonant* 3 min 46 sec 1 min 52 sec 56 sec 17 sec 9 sec 25X Faster! By Line + Resonant* + Bidirectional *w/3 line accumulations

Optimizing Resolution and Pixel Size Each objective lens is capable of achieving only so much resolution The pixel size of the image must be set properly to achieve the max resolution (lens resolution / 2.3) There are two ways to do this: 1. Increase zoom factor 2. Increase the number of pixels The software has a button that will increase the number of pixels to maximize resolution for a given lens However, more pixels take longer to scan Pixels smaller than theoretical best size have no additional benefit

Optimizing Images with the Histogram or Quick LUT Your eyes can deceive you. Don t trust them. Obi Wan Kenobi Images which are under or oversaturated are not using the dynamic range of the detector Undersaturated Oversaturated Properly saturated These images are missing information There are quantitative tools to help you choose the best laser power and gain

Saturated pixels @ 255 Frequency Pixel intensity values

Fill, but do not exceed the dynamic range of the detector

Blue pixels are saturated (intensity = 255)

Decrease laser power and/or gain until blue saturation indicator just disappears

Linear Z Compensation Optical aberrations get worse the deeper you image into a specimen z One result is decreasing signal during z stacks (usually noticeable > 20 um) x Laser power and gain can be automatically increased as a function of depth to help keep intensity constant through the sample confocal.uconn.edu/resources/

120 um z stack through mouse hippocampus

confocal.uconn.edu