PLOT PLAN INSTRUCTIONS ROOF MOUNT SOLAR AN ACCURATE PLOT PLAN IS NECESSARY TO PROCESS YOUR PERMIT

Similar documents
Basic Information Required for Photovoltaic Plan Check Submittal *Informational Purposes Only* 2013 CEC

Basic Information Required for Photovoltaic Plan Check Submittal *Informational Purposes Only*

SOLAR PV MICROINVERTER/ACM STANDARD PLAN - COMPREHENSIVE Microinverter and ACM Systems for One- and Two- Family Dwellings

RESIDENTIAL SOLAR ROOF TOP EXPEDITED PERMITTING GUIDELINE. 10 KW OR LESS

Supplemental Calculation Sheets for Inverter #2

Single-Family Dwelling Submittal Requirements

Residential Plot Plans

Planning and Building Services Solar PV Standard Plan Simplified Central/String Inverter Systems (One- and Two-Family Dwellings)

City of Lompoc Building & Safety Services Section 100 Civic Center Plaza Lompoc, CA Phone: Fax:

Estimated Cost of Project Contractor License No. Contractor Qualifier No.

PLAN SUBMITTAL REQUIREMENTS

FSEC APPROVAL # XL15-NT

CP /240-MC4 User Manual

RESIDENTIAL BUILDING PERMIT REQUIREMENTS

Energy Management Service

APS M1P Single-phase Micro-inverter Installation and User Manual

Article 225: Outside Branch Circuits And Feeders

APS M1P Single-phase Micro-inverter Installation and User Manual

RESIDENTIAL DEMOLITION PERMIT APPLICANT CHECKLIST

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Residential Construction Checklist Single and Two Family Construction

TRIBAL BUILDING AND DEVELOPMENT Plan Check Submittal

City of Santa Paula Planning Department

APPLICATION FOR CERTIFICATE OF APPROPRIATENESS IN THE HISTORIC DESIGN REVIEW DISTRICT

Permits (Submitted to Permit Counter) APPLICATION CHECKLIST

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5

Signs, Canopies & Awnings City of Oshkosh Department of Community Development

2. Determine the number of Modules/Microinverters required. (1134 modules is 2 less than 250 KW but works well with max comm.

SUMMIT COUNTY PLANNING AND ENGINEERING DEPARTMENT

Mailing Address: Fax number: City: State: Zip: Property Owner: City: State: Zip: City: State: Zip:

White Lake Township Building Dept Highland Rd. (248) White Lake, MI Fax (248)

Tel: Fax:

SUBMITTAL REQUIREMENTS FOR COMMERCIAL SIGNAGE PROJECTS

DESIGN REVIEW BOARD APPLICATION EXTERIOR PLAN / LANDSCAPE PLAN

Non-Residential and Multi-Family Plan Check Submittal Requirements

Installation requirements

University of Central Florida Main Campus. Electric. Service and Meter Installations Requirements. Issued January 26 th, 2017.

DEVELOPMENT SERVICES SITE PLAN SUBMITTAL 2.2.3

PLANNING DEPARTMENT SUBMITTAL REQUIREMENTS FOR CONDITIONAL USE PERMITS CLASS 4 DEVELOPMENT REVIEW PROCESS. A. Written Material

Developer Design Review Submittal Requirements - SECTION 5

Clear Creek County Site Development

SINGLE PHASE BUCK & BOOST TRANSFORMERS INSTRUCTION MANUAL

b. Building Areas or Building Pads having an average grade steeper than 5% (some elevation information may be required to verify grade).

Installation/User Manual

2014 NEC Changes Part 1

UNITY/I TM. Installation Manual. UT3K, UT4K, UT5K and UT8K. Single-Phase Uninterruptible Power Systems

Residential Room Addition / Remodel Submittal Requirement Checklist

CHECKLIST THE FOLLOWING INFORMATION AND DOCUMENTATION MUST BE SUBMITTED TO DEVELOPMENT SERVICES BEFORE YOUR APPLICATION CAN BE PROCESSED.

REQUIRED MATERIALS FOR RESIDENTIAL ACCESSORY STRUCTURE PERMITS (Garages, Sheds, and other structures over 200 sq ft or on a permanent foundation)

BETTER DESIGN BETTER MATERIALS BETTER PROCESSES BETTER MODULES

Community & Economic Development Department Planning Division Frederick Street PO Box 8805 Moreno Valley, CA SUBMITAL REQUIREMENTS

Code Red: Notable Changes in the 2011 NEC

CBCT TM CIRCUIT BREAKER COIL TESTER

Application Note: String sizing Conext CL Series

I n s ta l l at i o n M a n u a l f o r T E D P r o H o m e T E D P r o L i t e A B C Rev 4.0

Residential Room Additions

SUBMITTAL REQUIREMENTS FOR COMMERCIAL BUILDING PROJECTS

DECK PERMIT APPLICATION PACKET

REQUIRES LESS LABOR MADE NESTS TOGETHER FOR LOW COST SHIPPING UNIVERSAL MOUNTING MADE IN THE USA LOWER FREIGHT MESSENGER WIRE NO SHARP EDGES

SECTION EMERGENCY RESPONDER RADIO COVERAGE SYSTEMS

City of Del Mar Planning Department Submittal Checklist ADR ADMINISTRATIVE DESIGN REVIEW PERMIT

I n s t a l l a t i o n M a n u a l. T E D P r o L i t e A B C. f o r. Shop for The Energy Detective products online at: Rev 3.

Checklist for Minor Plan Modification

Minor Site Plan Review Process

LARAMIE COUNTY PLANNING & DEVELOPMENT OFFICE 3966 Archer Pkwy Cheyenne, WY Phone (307) Fax (307)

City of Whitefish Planning & Building Department PO Box E 2 nd Street Whitefish, MT Phone: Fax:

New Tools for PV Array Commissioning and Troubleshooting

Photovoltaic System Commissioning and Testing A Guide for PV System Technicians and Engineers

DOCUMENT SUBMITTAL REQUIREMENTS FOR A NEW SINGLE-FAMILY DWELLING

City of Whitefish 418 E 2 nd St PO Box 158 Whitefish, MT Phone: Fax:

National Marine Manufacturers Association Compliance Specialist Examination A.C. Electrical (2018 Model Year) ABYC E-11 Supplement 56

MULTIPLE-FAMILY DESIGN REVIEW SUBMITTAL CHECKLIST

CITY OF BURLINGAME - PLANNING COMMISSION SUBMITTAL REQUIREMENTS RESIDENTIAL DESIGN REVIEW

NEW SINGLE FAMILY HOMES

NON-RESIDENTIAL DEVELOPMENT

Table K. Input/Output Ratings & External Wiring Requirements for the Powerware /80 Rating 50/60 Hz. kva kw VOLTS VOLTS / /220

Emergency responder radio coverage in new buildings. California Fire Code Section is hereby amended to read:

The Bluffs at Eagle. Design Review Application. Date Bluffs Lot Number Street Address. Address. and/or fax. Address. Owner (if different) Phone

GENERAL REQUIREMENTS (Print or Type) PROJECT DESCRIPTION OWNER CERTIFICATION

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

Promontory Architectural Review Committee

PROJECT ENTITLEMENT APPLICATION

BUILDING & SAFETY DIVISION 110 E. LA HABRA BLVD. LA HABRA, CA Rev. 06/17

Remotes Case 2&3 Form REINDEER Cases 2&3 -Connection Impact Assessment (CIA) Application

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section ELECTRICAL IDENTIFICATION

Checklist for Tentative Subdivision Map

SIGN PERMIT APPLICATION

Applying for a Site Development Review (Sign CVCBD only)

Calculating AC Line Voltage Drop for M215 Microinverters with Engage Cables

APPLICATION DESIGN REVIEW Please Print or Type

Installation Instructions

SECTION CABLE TRAYS

Operating Manual SUNNY CENTRAL 500CP-US/CA / 500CP-US/CA 600V / 630CP-US/CA / 720CP-US/CA / 750CP-US/CA / 800CP-US/CA / 850CP-US/CA / 900CP-US/CA

Yavapai County Development Services

60 cell LG300N1K-G4. Key Features. High Power Output. Enhanced Performance Warranty. Outstanding Durability. Aesthetic Roof

701 OCEAN STREET, 4 TH FLOOR, SANTA CRUZ, CA (831) FAX: (831) TDD: (831)

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

dpd client assistance memo CAM Plot Plan Requirements Basic Plot Plan What is a Plot Plan?

Information package for obtaining a building permit

Transcription:

PLOT PLAN INSTRUCTIONS ROOF MOUNT SOLAR Building Division 1855 Placer Street, Suite 102 Redding, California 96001 Phone: (530) 225-5761 Fax: (530) 245-6468 Inspection Request Line: (530) 244-5068 Web: building.co.shasta.ca.us Email: resourcemanagement@co.shasta.ca.us (Rev: 08-09-17) AN ACCURATE PLOT PLAN IS NECESSARY TO PROCESS YOUR PERMIT A plot plan is necessary to establish a clear record of the permitted development and use(s) on the property prior to the installation of your solar project. You may start with an Assessor s plat map (copies available at the Assessor s office) for an accurate outline of your property. On 8-1/2 x 11 paper or larger you will need to include the elements noted below and keep the size proportionate based on parcel size, location of equipment, and structures. The following elements will need to be illustrated and identified on the Roof Mount Solar plot plan: 1. Property owner s name 2. Assessor s Parcel Number for the property 3. Address of property 4. North arrow and scale 5. Identify the primary residence with square footage(s) a. Include all attached structures to the residence (carport, awnings, garage) labeled with square footage 6. Identify accessory buildings and attachments with square footages only if served by or housing the solar equipment including, but not limited to, solar panels, inverters, disconnects, rapid shutdown, batteries, sub-panel, and main service panel. a. This element is not required if no solar equipment is located on or within the accessory structure 7. Dimension fire setbacks of the solar panels on the roof structure including distances from ridge, valley, eave and rake. 8. Identify access roads, driveways, drainages and waterways; including seasonal or dry creek beds 9. Identify existing electrical utility locations, new utility locations, and any trenching for this project ** Note: an example is provided on the back of this page for guidance.

Building Division 1855 Placer Street, Suite 102 Redding, California 96001 Phone: (530) 225-5761 Fax: (530) 245-6468 Inspection Request Line: (530) 244-5068 Web: building.co.shasta.ca.us Email: resourcemanagement@co.shasta.ca.us ROOF MOUNT PV SOLAR SUBMITTAL CHECKLIST (Rev: 08/09/17) As the applicant you are acknowledging all of the checklist information is included and understand an incomplete submittal may not be accepted or processed. Please initial next to each line item below to confirm the roof mount solar submittal is complete. 1. 2 copies of the complete and accurate plot plan (see roof mount plot plan); and a. [ ] 2 signed copies by the Fire District office (if other than Shasta County Fire) 2. A complete building permit application with the Qualified Personnel identified (CEC 690.4 c) that will perform the work with an approved State of California Contractor s License. 3. 2 complete sets of the following permit documents stapled together using a min. 12 pt. font. b. [ ] Manufacturer cut sheets and manufacturer s installation manual for all equipment to be used for the project. These documents can be separate from the plans, but the equipment submittal will be specific to this project, easily identified, and highlighted with all of the required Class A fire rating, UL Listing, and engineering for all solar and solar racking systems including 2703 certification for grounding/bonding of the module/racking assembly and connectors. c. [ ] Complete and accurate PV Solar System Summary sheet (attached) d. [ ] Cost breakdown of solar equipment, labor, and structural costs for PV Solar systems. e. [ ] Roof Plan showing arrangement of panels setbacks, combiner box, inverter, disconnect, main service, show approx. distance from panel to all components and required Fire Code clearances. f. [ ] Electrical one-line diagram of system (module wiring (series/parallel), disconnects, grounding/bonding, wire, conduit size, and number of conductors in each section of conduit). When batteries are to be installed, include them in the diagram, the location, cabinet, listing, required venting, and show working clearances. g. [ ] Size and location of the service panel side connection per CEC article 705 h. [ ] Load calculations are provided for the proposed or required de-rated service panel. i. [ ] UL (1-800-595-9844) will re-certify the service panel prior to final, if a tap is made. j. [ ] Design criteria with the 2016 California Model Codes, including 110mph wind speed, and the accurate snow load based on Shasta County s non-reducible loading is provided. k. [ ] A complete signage plan is included. (See example) 4. The solar system will be installed on pre-engineered plant manufactured trusses with a maximum spacing of roof attachments not to exceed 4 o.c. I also understand Shasta County reserves the right to require engineering for any roof system regardless of the configuration 5. The solar system is proposed to be installed on hand cut rafters and the span chart is supplied and highlighted from the building code; or the required engineering is included with this submittal. 6. Conductors that penetrate the building will be installed in a metallic raceway or enclosure that will be attached to the first readily accessible disconnect at the exterior of the building. 7. Conductors will be PV specific, approved for outdoor - wet condition(s), and UV protected. 8. This solar system is proposed to be installed on an Agricultural exempt structure and the required engineering for the structure is included with this submittal. 9. This system is greater than 30KW and has PG&E approval with electrical engineered plans. 10. I understand that field changes or any deviation from the approved plans will incur additional fees

ROOF MOUNT PV SOLAR SYSTEM SUMMARY KW [ ] Off-Grid [ ] Grid Tie [ ] Backup Generator [ ] Batteries ROOF MOUNTED SYSTEMS PROVIDE Existing Roof type: (circle one) Truss or Stick Frame If the roof is stick-frame, provide the following: Rafter size Rafter Spacing Rafter Span INVERTER(S): Number of Inverter(s) Model Number DC Input Voltage Range Listed for Utility Interconnection (Y, N) Inverter Continuous AC out current rating x 1.25 = Inverter output conductor sizing: listed continuous output x 1.25) CEC Section 690.8 (3) and 690.8 (B)(1) MODULES Total number of modules per inverter From the module listing: *Maximum system voltage Short-circuit current (Isc) Maximum series fuse rating Model Number Open-circuit voltage (Voc) Voltage at Pmax Current a Pmax Calculated system voltage = (Voc x #of modules in series x 1.13) NEC 690.7 Calculated system voltage must be less than or equal to the *Maximum system voltage. ARAY INFORMATION Total number of modules Number of modules in each series Number of parallel source circuits Operating voltage volts (Voltage at Pmax x number of modules in series) Operating current amps (Current at Pmax x number of strings in parallel) Minimum PV source circuit ampacity for conductor sizing x 1.25 x 1.25 = (Isc x number of parallel circuits x 1.25 x 1.25) NEC 690.8A-1, 690.8B-1 and NOTE 2. Explanation: To determine wire sizing and over current protection you must determine the minimum source circuit conductor ampacity which is 125% of the maximum PV source circuit current ampacity (NEC 690.8.A-1). The maximum PV source circuit current ampacity is 125% of the source circuit ampacity or Isc (NEC 690.8B-1). NOTE 1: NOTE 2: All wiring rated at 90 degrees and equipment on array side of the inverter must be DC rated. Further ampacity adjustments are necessary when more than 3 current carrying conductors are installed in the conduit. See NEC Table 310.15(B)(2)(a)

REQUIRED WARNING LABELS Include diagrams of warning labels on the plans per Article 690 of the California Electrical Code. Examples and required locations are shown below. CAUTION: SOLAR CIRCUIT Conduit raceways, enclosures, cable assemblies, and junction boxes shall be marked with this label. CAUTION: SOLAR ELECTRIC SYSTEM The electrical main service disconnect shall be marked with this label. WARNING: ELECTRIC SHOCK HAZARD DO NOT TOUCH THE TERMINAL The inverter shall be marked with this label TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION DIRECTORY PLAQUE When service disconnecting means and PV system disconnecting means are NOT located at the same location, install a directory plaque at the service and PV system disconnecting means. Art. 690.56(B) PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN The electrical main service panel shall be marked with this label. Art. 690.56(C)