DIGITAL UNDER-OVER VOLTAGE RELAY DMPVR SERIES

Similar documents
DIGITAL UNDER-OVER VOLTAGE RELAY DMPVR SERIES

STATIC UNDER-OVER VOLTAGE RELAY VD SERIES

DIGITAL EARTH FAULT RELAY

STATIC PHASE FAILURE RELAY

STATIC EARTH FAULT RELAY

MOTOR PROTECTION RELAY

RESTRICTED EARTH FAULT RELAY

DIGITAL EARTH FAULT RELAY

Voltage Relays. Ensuring Reliable Protection for Electrical Systems against Voltage Faults. ISO 9001:2008 Certified.

Earth Fault Relay EFSPL-1A/5A

Technical Datasheet. True RMS Digital Protection Relay. Voltage Protection Relay

Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

Guidelines to Using a Three Phase Voltage Monitor

Relay. Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W

XP2-R Power and reverse power relay. (January 2006) Manual XP2-R (Revision New)

XP2-R Power and Reverse Power Relay

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

USER MANUAL ULD 910. October 2003 Revision: 03. Single Channel Vehicle Detector ULD 910. Part Number: MIC

SCR CONTROLLER SYSTEM

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS

Installation and start up instructions. Detection of vector shift. Detection of over- and underfrequency. Generator disconnection on mains failure

WD series DIN Rail or Screw Mounted Protective Relays

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

IPS INTELLIGENT PUMP STARTER. Integrated Tru-power electronic motor and pump protection

MOTOR / PUMP PROTECTION RELAYS

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

3-phase voltage monitoring relay EMR SU31D

MT 560/UMT TRANSDUCER & ANALYZER

Dual Channel Vehicle Detector ULD 920 USER MANUAL Part Number: MIC ULD 920

Fan and Pump AC Inverter

Universal Protective Relay Test Set

AC Magnetic Starters (GE)

RMV-122D, RMV-132D ANSI

Technical Data Sheet

High speed bus transfer function block description Operation Manual

ATS Controller (KSC-5000) Manual

Overvoltage and undervoltage. Dr Audih 1

Stabilized Differential Relay SPAD 346. Product Guide

www. ElectricalPartManuals. com Basler Electric P. 0. BOX 269 HIGHLAND, ILLINOIS 62249, U.S.A. PHONE FAX

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

ELSEMA GLR Applications Automatic gates. Security systems. Timer controlled outputs. Simple on/off functions.

Functional Range. IWE - Earth Fault Relay. C&S Protection & Control Ltd.

Cover Page - Electric Actuators & Accessories. Standard & Optional Features. OM Actuator Standard Features. OM Actuator Optional Features

GS1 Parameter Summary Detailed Parameter Listings...4 9

1. INTRODUCTION Fire Mode PID Application Parameter lists DESCRIPTION OF PARAMETERS... 8

Digital Multifunction Instrument - Rish Master 3440

ECET 211 Electric Machines & Controls Lecture 7 Relays. Lecture 7 Relays

200ADM-P. Current Injection System with Phase Shift A 3.000s 2.000A 50.00Hz 0.0. Features

DATA SHEET Reverse power relays, RMP-121D ANSI code 32

PHASE FAILURE RELAYS. FEATURES Fixed/adjustable unbalance settings Fixed/adjustable undervoltage/over-voltage PROTECTIONS / FUNCTIONS

Typical Oscillography Settings For the G60 GE Multilin No. GET-8481 Prepared by Darryl Brunner C.E.T.

5 Channel Multifunctional PWM Controller. HomLiCon LCH5T. Technical Specifications

METERSUK. SmartLink D Y N A M i T E. EM735 S Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION.

NTG MULTIFUNCTON GENERATOR PROTECTION RELAY. NTG-Slide

Signet 9900 Transmitter

Application and Commissioning Manual for Numerical Over Current Protection Relays Type MIT 121/131 CONTENTS PAGE APPLICATION 2-4 INSTALLATION 5-11

Protective Relays Digitrip 3000

Signet 9900 Transmitter

Variable Speed Brushed DC Motor Drive

Type VAEM 22 Negative Potential Biasing Relay

Power systems Protection course

Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide

Electronic circuit breaker ESS30-Sxxx-DC24V

Ziegler EM 1320/30/40


NICE900 -Door Drive Setup Manual for Asynchronous / Synchronous Motor with Encoder Feedback (Document Release Dt ) Sr. No

Transformer Winding Machine Controller (CNC-07SG)

Utility Interconnection and System Protection

How to Guide: Controlling Blinds in C-Bus

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

3. Be aware of the ambient temperature. Use the unit within the specified ambient temperature only.

Voltage Monitors & Phase Monitors

RI-R11 series RI-R11D series

SHORT FORM. Product Catalog. (800) time-mark.com

Application: Product Features: On site programmable PT/CT ratios: User selectable CT Secondary 5A/1A. User selectable PT Secondary

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Microprocessor Control Board Set Up Procedures (OR PLC)

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Introduction: TAS PowerTek Ltd. MAVROS

Power Factor Correction

Technical Data Sheet. x1000. kwh R Y B

02/11/2015

CET 5 Motor Protection Relay. Programming Menu Structure

Product Data Sheet. Models 1022/1025/1029C/1032/3629B 3629B. Models 1022/1025/1032. Model 1029C. Model 3629B. Phase Angle Power Control

WHEN A PLC IS TOO MUCH, AND SPACE FOR

EARTH LEAKAGE RELAY RELAY FOR PERMANENT CONTROL OF THE MCCB S TRIPPING CIRCUIT AND ACTUATOR FOR SAFETY CIRCUITS

General Purpose Drives

Content. Monitoring relay pluggable. 1-phase current monitoring relay phase direct-current voltage monitoring relay... 5.

www. ElectricalPartManuals. com Type CGR Ratio Ground Relay Descriptive Bulletin Page 1

Operating Instructions for SymCom s INFORMER MS EDITION DIAGNOSTIC TOOL

NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives

MFJ ENTERPRISES, INC.

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

Substation Monitoring with TESLA

Electronic measuring and monitoring relays CM-range

Transcription:

DIGITAL UNDER-OVER VOLTAGE RELAY

Features User friendly setting Parameters Monitor the line to line voltages continuously Built in on delay and trip delay time settings Field configurable reset gap voltage Direct display of line to line voltages in 3 Phase models Set value of Under Voltage (UV) and Over Voltage (OV) in terms of Set voltage directly Phase fail and phase reversal protection in 3 phase models Indication of faults through LED and LCD Independent potential free output contacts for Under Voltage (UV)/ph. fail,ph reversal and Over Voltage(OV) Applications Protection of Synchronous and induction motor of any HP Rating Protection of Generators, AMF switched Board Transformer Feeder Panel Distribution Boards Voltage Regulators Protection of UPS and Single phase application Specifications 1. Under Voltage Range:- 070V to 105V in steps of 1V for 110V L-L (Un) 300V to 410V in steps of 1V for 415V L-L (Un) 150V to 230V in steps of 1V for 240V P-N (Un) 2. Under Voltage trip time: - 0.1 to 20 sec in steps of 0.1 sec 3. Over Voltage (OV) Range:- 115V to 140V in steps of 1V for 110V L-L (Un) 420V to 500V in steps of 1V for 415V L-L (Un) 250V to 300V in steps of 1V for 240V P-N (Un) 4. Over Voltage (OV) trip time:- 0.1 to 20 sec in steps of 0.1 sec 5. Reset gap for Under Voltage (UV)/Over Voltage (OV):- 5 to 20V in steps of 5V 6. On Time delay: - 1 to 30 sec in steps of 1sec 7. Trip time for phase fail & phase reversal: 2 sec 8. Auxiliary supply - 85-275VAC/DC Note: Under Voltage (UV) Relay energize /de energize option for factory setting, Default: Under Voltage (UV) De Energize Over Voltage (OV) Relay energize /de energize option for factory setting, Default: Over Voltage(OV) De Energize

SETTING PROCEDURE * Refer to the wiring diagram. Connect the Aux supply (85-275V AC/DC) & 3 Phase sensing voltage to the DIGITAL MICROCONTROLLER BASED THREE PHASE OVER VOLTAGE (OV) AND UNDER VOLTAGE (UV). Display shows for a while. Vltg Rly 3PH V2.0 And then display line to neutral voltages VRY VYB 400 400 VBR L-L 400 V L-L Press key & key simultaneously and release display shows- menu for Over Voltage (OV) Select the desired Over Voltage (OV) in the range of 420 to 500v OV =460V 420-500V Use or key to enter the required Over Voltage (OV) voltage directly in steps of 1V, press SET key to save the value and move on to the next parameter. Now display shows -menu for Under Voltage Select the desired Under Voltage in the range of 300 to 410V UV =360V 300-410V Use or key to enter the required Under Voltage (UV) voltage directly in steps of 1V, press SET key to save the value and move on to the next parameter. Now Display shows - menu for Reset Gap for Over Voltage (OV)/Under Voltage (UV)( RG - Reset Gap) RG=05.0V 5-20V Use or key to enter the required Reset Gap voltage value in steps of 5V, press SET keyto save the value and move on to the next parameter. Display shows -menu for On Time Delay for OD( OD- On Time Delay) OD = 10 S 1-30 S Use or key to enter the required On delay in steps of 1 S, press SET key to save the value and move on the next parameter. Display shows - menu for Time delay for Under Voltage (UV)( UTT- Under Voltage Trip Time) Use or key to enter the required Trip delay for Under Voltage (UV) in steps of 0.1 S, press SET key to save the value and move on the next parameter UTT = 5.0 0.1- - 20 S Display shows menu for Time delay for Over Voltage (OV)( OTT- Over Voltage (OV)er Voltage Trip Time) OTT = 5.0 0.1-20 S Use or key to enter the required Trip delay for Over Voltage (OV) in steps of 0.1 S, press SET key to save the value. Display shows all the three phase voltages.( when all 3phase sensing voltages are connected) 400 400 400 V L-L This completes the setting of the voltage relay. In the absence of sensing input voltages display shows by indicating the Under Voltage (UV) LEDIf the sensing voltage input VRY, VYB, VBR UV TRIP BR< 25

Mechanical Dimensions DIGITAL MICROCONTROLLER BASED THREE PHASE OVER VOLTAGE (OV) AND UNDER VOLTAGE (UV) RELAY FLUSH MOUNTING DIN MOUNTING

Wiring Diagram DIGITAL MICROCONTROLLER BASED THREE PHASE OVER VOLTAGE (OV) AND UNDER VOLTAGE (UV) RELAY FLUSH MOUNTING MCCB/ACB/CONTACTORS DIN MOUNTING MCCB/ACB/CONTACTORS

ISO 9001-2015 PROK DEVICES PRIVATE LIMITED nd rd B-80, 2 & 3 Floor, KSSIDC Industrial Estate th th 4 Main Road, 6 Block, Rajajinagar Bengaluru-560010 Karnataka,India Ph. No: 080-4148 0777 080-4115 7700 Fax:+91 80 26761720 For Marketing Information & Assistance enquiry@prokdvs.com marketing@prokdvs.com For Product Information & Technical Details info@prokdvs.com For Service Information service@prokdvs.com