MINI MCR-SL-UI-I-LP-NC

Similar documents
MACX MCR-UI-UI-UP(-SP)(-NC)

MINI MCR-SL-UI-f(-SP)

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

Extract from the online catalog

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

Signal conditioner - MACX MCR-UI-UI-NC

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

MCR-C-UI-UI-DCI. Extract from the online catalog. Order No.:

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

MINI-PS AC/24DC/1.3

PACT RCP-4000A-UIRO-Dxxx

MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

QUINT-PS AC/24DC/40

MINI-PS AC/2X15DC/1

QUINT-PS-24DC/24DC/10

PSD-S AE SM DB/1

QUINT-PS/ 3AC/24DC/10

QUINT-PS/ 3AC/24DC/40

PRetrans Table of contents

MCR-T-UI(/NC) MCR-T-UI-E(/NC)

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

QUINT-PS/ 1AC/24DC/20

PHOENIX CONTACT

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

PHOENIX CONTACT - 09/2009

PHOENIX CONTACT

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

OPTITEMP TT 10 C/R Technical Datasheet

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

TRIO-PS-2G/1AC/24DC/5

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply

CompactLogix 5370 L3 Control System

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

MACX MCR-EX-SL-RPSSI-I

VariTrans P V. Safe and Sound.

Assembly. Front view. Parametrization interface. Power Bus

Liquid level monitoring relay CM-ENS.2x

58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4

Power supply CP-T 24/20.0 Primary switch mode power supply

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Power supply CP-E 24/2.5

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

Power supply CP-E 24/20.0

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Power supply CP-T 48/20.0 Primary switch mode power supply

PHOENIX CONTACT - 01/2007

Operating Instructions

Power supply CP-T 48/5.0 Primary switch mode power supply

MODEL: M2DYS SEN TRONIC AG

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

Power supply CP-D 24/1.3

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Inductive sensor slot-type SI2-K08-AP7

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

This data sheet is only valid in association with the IL SYS INST UM E user manual.

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

Thermocouple - Transducer

FOUNDATION Fieldbus Junction Box

Power supply CP-D 12/2.1

Pressure transmitter AKS 32 and AKS 33

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

3B SCIENTIFIC PHYSICS

Power supply CP-E 24/0.75

Power supply CP-E 24/2.5

Three-phase monitoring relay CM-PFS

IB IL TEMP 2 RTD (-PAC)

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

2-WiRE LEvEL TRansmiTTER PRELEvEL 5343 ConTEnTs

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Isolators A3/1.

Assembly. Front view. HiC2441. SL2 1b. Termination Board

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Assembly. Front view. Power Rail

Coupling Relays and Converters

5 years! Modular Housings. VariTrans P Warranty

User and Safety Manual ProLine P224xx P1

Temperature Input Module for Zone 1 Series 9482/32

WS12EX Position Sensor with Analog output Dust explosion-proof

MDC4500-4B Amplifier/Combiner Data Sheet & User Manual. February Rev 0.95

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Transcription:

2-way isolation amplifier Data sheet 105263_en_02 PHOENIX CONTACT 2013-12-13 1 Description The configurable 2-way isolation amplifiers are used to electrically isolate, convert and filter standard signals. You can configure analog voltage or current signal areas on the input side using the DIP switch. The isolation amplifier supplied by the output loop enables connection of ah active analog input module of a controller. Supply takes place via the active 4...20 ma loop of the controller. Features Configurable 2-way isolation amplifier Approval for Ex-zone 2 (na) Screw or spring-cage connection can be provided NOTE: Correct usage in potentially explosive areas The module is a category 3 item of electrical equipment. It is absolutely vital to follow the instructions provided here during installation and observe the information in the "Safety regulations and installation notes". Make sure you always use the latest documentation. It can be downloaded from the product at phoenixcontact.net/products. This data sheet is valid for all products listed on the following page:

2 Table of contents 1 Description... 1 2 Table of contents... 2 3 Ordering data... 3 4 Technical data... 4 5 Safety regulations and installation notes... 7 5.1 Installation notes... 7 5.2 Installation in the Ex area (zone 2)... 7 6 Installation... 8 6.1 Connection notes... 8 6.2 Structure... 8 6.3 Block diagram... 8 6.4 Power supply... 8 6.5 Assembly... 9 6.6 Connection of the cables... 9 7 Configuration... 10 7.1 Configuration table... 11 8 Adjustment... 12 8.1 Easy adjustment... 12 8.2 Output with adjustment point calculation... 12 105263_en_02 PHOENIX CONTACT 2

3 Ordering data Description Type Order No. Pcs. / Pkt. 2-way loop-powered isolating amplifier (supplied on the output side), can be configured via DIP switches, with screw connection technology and standard configuration. 2-way loop-powered isolating amplifier (supplied on the output side), can be configured via DIP switches, with spring-cage connection technology and standard configuration. MINI MCR-SL-UI-I-LP-NC 2902829 1 MINI MCR-SL-UI-I-LP-SP-NC 2902830 1 Accessories Type Order No. Pcs. / Pkt. Eight MINI analog signal converters with screw connection method can be connected to a control system using a system adapter and system cabling with a minimum of wiring and very low error risk. Fold up transparent cover for MINI MCR modules with additional labeling option using insert strips and flat Zack marker strip 6.2 mm Label for extended marking of MINI MCR modules in connection with the MINI MCR-DKL MINI MCR-SL-V8-FLK 16-A 2811268 1 MINI MCR DKL 2308111 10 MINI MCR-DKL-LABEL 2810272 10 105263_en_02 PHOENIX CONTACT 3

4 Technical data Input Voltage input signal Max. voltage input signal 0 mv... 1000 mv 0 mv... 750 mv 0 mv... 500 mv 0 mv... 300 mv 0 mv... 250 mv 0 mv... 200 mv 0 mv... 150 mv 0 mv... 125 mv 0 mv... 120 mv 0 mv... 100 mv 0 mv... 75 mv 0 mv... 60 mv 0 mv... 50 mv 0 V... 10 V 0 V... 7.5 V 0 V... 5 V 0 V... 3 V 0 V... 2.5 V 0 V... 2 V 0 V... 1.5 V 0 V... 1.25 V 0 V... 1.2 V 0 V... 30 V 0 V... 25 V 0 V... 20 V 0 V... 12.5 V 0 V... 12 V 0 V... 15 V -1000 mv... 1000 mv -750 mv... 750 mv -500 mv... 500 mv -300 mv... 300 mv -250 mv... 250 mv -200 mv... 200 mv -125 mv... 125 mv -120 mv... 120 mv -150 mv... 150 mv -100 mv... 100 mv -75 mv... 75 mv -60 mv... 60 mv -50 mv... 50 mv -10 V... 10 V -7.5 V... 7.5 V -5 V... 5 V -3 V... 3 V -2.5 V... 2.5 V -2 V... 2 V -1.25 V... 1.25 V -1.2 V... 1.2 V -1.5 V... 1.5 V -30 V... 30 V -25 V... 25 V -20 V... 20 V -12.5 V... 12.5 V -12 V... 12 V -15 V... 15 V 1 V... 5 V < 40 V 105263_en_02 PHOENIX CONTACT 4

Input [...] Current input signal 0 ma... 40 ma 0 ma... 30 ma 0 ma... 20 ma 0 ma... 12 ma 0 ma... 10 ma 0 ma... 8 ma 0 ma... 7.5 ma 0 ma... 5 ma 0 ma... 6 ma 0 ma... 4 ma 0 ma... 3 ma 0 ma... 2.5 ma 0 ma... 2 ma 4 ma... 20 ma 2 ma... 10 ma 1 ma... 5 ma Max. current input signal < 50 ma (Dielectric strength up to 30 V) Input resistance of voltage input approx. 100 kω (At 1 V, otherwise approximately 1 MΩ) Input resistance current input Output Current output signal 50 Ω 4 ma... 20 ma Max. current output signal 35 ma (output limit) Configurable/programmable Yes, preconfigured Ripple < 20 mv PP (at 500 Ω) Load/output load current output ((U B - 8 V) / 22 ma) Supply Supply voltage range Power consumption 8 V DC... 30 V DC 28 mw (without signal) General data Limit frequency (3 db) approx. 30 Hz Maximum transmission error < 0.1 % (of final value) < 0.2 % (Without adjustment) Temperature coefficient, typical 0.005 %/K Maximum temperature coefficient 0.01 %/K Alignment zero ± 2 % Alignment span ± 2 % Step response (10-90%) approx. 16 ms Electrical isolation Basic insulation according to EN 61010 Surge voltage category II Mounting position any Degree of protection IP20 Pollution degree 2 Rated insulation voltage 50 V AC/DC Dimensions W / H / D 6.2 mm / 93.1 mm / 102.5 mm Type of housing PBT green Connection data Screw connection Spring-cage conn. Conductor cross section, solid 0.2 mm²... 2.5 mm² 0.2 mm²... 2.5 mm² Conductor cross section, stranded 0.2 mm²... 2.5 mm² 0.2 mm²... 2.5 mm² Stripping length 12 mm 8 mm 105263_en_02 PHOENIX CONTACT 5

Ambient conditions Ambient temperature (operation) -25 C... 70 C Ambient temperature (storage/transport) -40 C... 85 C Conformance with EMC Directive 2004/108/EC Noise immunity according to EN 61000-6-2 When being exposed to interference, there may be minimal deviations. Noise emission according to EN 61000-6-4 Conformance / approvals Conformance ATEX UL, USA / Canada UL, USA / Canada UL, USA / Canada CE-compliant II 3 G Ex na IIC T4 Gc X UL 508 Listed Class I, Div. 2, Groups A, B, C, D T5 Class I, Zone 2, Group IIC 105263_en_02 PHOENIX CONTACT 6

5 Safety regulations and installation notes 5.1 Installation notes The category 3 device is suitable for installation in the zone 2 potentially explosive area. It fulfills the requirements of EN 60079-0:2009 and EN 60079-15:2010. Installation, operation, and maintenance may only be carried out by qualified electricians. Follow the installation instructions described. When installing and operating the device, the applicable regulations and safety directives (including national safety directives), as well as general technical regulations, must be observed. The technical data is provided in this package slip and on the certificates (conformity assessment, additional approvals where applicable). It is not permissible to open or modify the device. Do not repair the device yourself but replace it with an equivalent device. Repairs may only be carried out by the manufacturer. The manufacturer is not liable for damage resulting from violation. The IP20 degree of protection (IEC 60529/EN 60529) of the device is intended for use in a clean and dry environment. Do not subject the device to any load that exceeds the described limits. The device is not designed for use in atmospheres with a danger of dust explosions. 5.2 Installation in the Ex area (zone 2) Observe the specified conditions for use in potentially explosive areas. The device must be installed in a housing (control or distributor box) which meets the requirements of EN 60079-15 and provides at least IP54 (EN 60529) degree of protection. During installation and when connecting the supply and signal circuits, observe the requirements of EN 60079-14. Devices may only be connected to circuits in zone 2 if they are suitable for operation in Ex zone 2 and for the prevailing conditions at the place of use. In potentially explosive areas, terminals may only be snapped onto or off the DIN rail connector and wires may only be connected or disconnected when the power is switched off. The device must be stopped and immediately removed from the Ex area if it is damaged, has been subjected to an impermissible load, has been stored incorrectly, or if it malfunctions. You can download the latest documents for these devices from phoenixcontact.net/products. 105263_en_02 PHOENIX CONTACT 7

6 Installation 6.1 Connection notes 6.3 Block diagram Sensor / Field IN OUT PLC / DCS NOTE: electrostatic discharge! The device contains components that can be damaged or destroyed by electrostatic discharge. When handling the device, observe the necessary safety precautions against electrostatic discharge (ESD) according to EN 61340-5-1 and EN 61340-5-1. U S U S 4-wire 4-wire OUT I OUT U 1 2 + 1 IN I PWR IN 5 + passive 2 OUT I 6 3 + 3 4 4 IN U 7 8 5 6 PWR active 6.2 Structure 8 6 www.phoenixcontact.com 5 Serial No. 32825 Blomberg, Germany MINI MCR SL UI I LP NC Ord. No.: 29 02 82 9 Configurable Isolator (Loop-powered) IN U: +/ 50mV DC up to +/ 30V DC IN I: +/ 2mA up to +/ 40mA OUT: 4...20mA Loop: 8...30VDC T 25...+70 C amb PLC / DCS Sensor / Field PWR active 4 ZERO PWR IN passive OUT I 3 SPAN IN I IN U OUT I OUT U 4-wire 4-wire 5 + 5 1 + 1 6-6 2-2 7 3 + 3 8 4-4 1 0 ON S1 OFF U S U S II 3 G Warning Do n ot seperate when energized 7 1 Ex na II C T4 Gc X 9 2 10 Figure 2 Block diagram Zone 2 6.4 Power supply An ME 6,2 TBUS-2 DIN rail connector (Order No.: 2869728) is used to supply active devices. A DIN rail connector is not necessary for operation of this loop-powered device. This device can be snapped onto a DIN rail connector an electrically conductive connection is not established. This means that you do not need to disconnect an existing DIN rail connector element connection. Figure 1 Structure 1. Input: voltage signals 2. Input: current signals 3. Cover 4. ZERO potentiometer for adjustment 5. Groove for ZBF 6 zack marker strip 6. SPAN potentiometer for adjustment 7. Input supply voltage 8. Output 4... 20 ma 9. Universal snap-on foot for EN DIN rails 10. DIP switch S1 105263_en_02 PHOENIX CONTACT 8

6.5 Assembly Screw connection: B A www.interface.phoenixcontact.com SerialNo.XXXXXXXX Figure 3 Mounting and removing Figure 4 Screw connection Mount the module on a 35 mm DIN rail according to EN 60715. 6.6 Connection of the cables The MINI MCR-SL-UI-I-LP... is available in two connection versions: Screw terminal blocks (MINI MCR-SL-UI-I-LP-NC) Spring-cage terminal blocks (MINI MCR-SL-UI-I-LP- SP-NC) Insert the wire into the corresponding connection terminal block. Use a screwdriver to tighten the screw in the opening above the connection terminal block. Spring-cage connection: B A www.interface.phoenixcontact.com Serial No. XXXXXXXX Figure 5 Spring-cage connection Insert a screwdriver into the opening above the connection terminal block. Insert the wire into the corresponding connection terminal block. 105263_en_02 PHOENIX CONTACT 9

7 Configuration DIP switch S1 is used to specify the combination of input and output standard signal ranges (see "Configuration table"). Standard Configuration If it is an "NC version", the device has the standard configuration: Input 2...10 V Output 4...20 ma (All DIP switches are set to the off position, transmission error < 0.1%.) 105263_en_02 PHOENIX CONTACT 10

7.1 Configuration table DIP switch S1 is used to specify the combination of input and output standard signal ranges (see "Configuration table"). IN = ON DIP S1 Terminal Unipolar Bipolar Live Zero 1 2 3 4 5 6 7 8 9 0 0...40mA (1) (2) 0...30mA (1) (2) 0...20mA 4...20mA (1) (2) 0...12mA (1) (2) 0...10mA 2...10mA (1) (2) 0...8mA (1) (2) 0...7.5mA (1) (2) 0...5mA 1...5mA (1) (2) 0...6mA (1) (2) 0...4mA (1) (2) 0...3mA (1) (2) 0...2.5mA (1) (2) 0...2mA (1) (2) 0... 1000 mv ±1000 mv (3) (4) 0... 750 mv ±750 mv (3) (4) 0... 500 mv ±500 mv (3) (4) 0... 300 mv ±300 mv (3) (4) 0... 250 mv ±250 mv (3) (4) 0... 200 mv ±200 mv (3) (4) 0... 125 mv ±125 mv (3) (4) 0... 120 mv ±120 mv (3) (4) 0... 150 mv ±150 mv (3) (4) 0... 100 mv ±100 mv (3) (4) 0...75mV ±75mV (3) (4) 0...60mV ±60mV (3) (4) 0...50mV ±50mV (3) (4) 0... 10 V ±10 V 2... 10 V (3) (4) 0...7.5V ±7.5V (3) (4) 0...5V ±5V 1...5V (3) (4) 0...3V ±3V (3) (4) 0...2.5V ±2.5V (3) (4) 0...2V ±2V (3) (4) 0... 1.25 V ±1.25 V (3) (4) 0... 1.2 V ±1.2 V (3) (4) 0...1.5V ±1.5V (3) (4) 0... 30 V ±30 V (3) (4) 0... 25 V ±25 V (3) (4) 0... 20 V ±20 V (3) (4) 0... 12.5 V ±12.5 V (3) (4) 0... 12 V ±12 V (3) (4) 0... 15 V ±15 V (3) (4) Signal conversion IN bipolar / OUT Live zero (4... 20 ma) IN unipolar / OUT Live zero (4... 20 ma) IN Live zero / OUT Live zero (4... 20 ma) Additional signal combinations that are not listed in the table are available on request. 105263_en_02 PHOENIX CONTACT 11

8 Adjustment Two potentiometers are located under the cover. These are used for fine adjustment of the analog signals after the configuration of the DIP switches has been changed. The transmission error without adjustment is < 0.2 %. The transmission error without adjustment is <0.1%. You require measuring equipment with the corresponding accuracy for exact adjustment! 8.1 Easy adjustment Adjustment of the module via two potentiometers. ZERO potentiometer: zero point adjustment SPAN potentiometer: final value adjustment 8.2 Output with adjustment point calculation Specify the final value of the input signal with a calibration source initial and final value. Note the respective measured output value. Output signal: 4...20 ma Specification (input) Initial value Final value Measured value (output) MV 1 [ma] MV 2 [ma] Calculate the FS adjustment point A Specify the initial value of the input signal with a calibration source. SPAN potentiometer: FS adjustment point A ± 1 μa ZERO potentiometer: 20 ma ± 1 μa A = MV 2 x 16 ma MV 2 - MV 1 105263_en_02 PHOENIX CONTACT GmbH & Co. KG 32823 Blomberg Germany 12 phoenixcontact.com