A New Fault Detection Tool for Single Phasing of a Three Phase Induction Motor. S.H.Haggag, Ali M. El-Rifaie,and Hala M.

Similar documents
Fault Detection and Analysis of three-phase induction motors using MATLAB Simulink model

A new scheme based on correlation technique for generator stator fault detection-part π

An Ellipse Technique Based Relay For Extra High Voltage Transmission Lines Protection

INVESTIGATION OF THE IMPACT OF SPEED-RIPPLE AND INERTIA ON THE STEADY-STATE CURRENT SPECTRUM OF A DFIG WITH UNBALANCED ROTOR

Stator Fault Detector for AC Motors Based on the TMS320F243 DSP Controller

Voltage Sag Effects on the Process Continuity of a Refinery with Induction Motors Loads

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

MITIGATION OF VOLTAGE SAGS/SWELLS USING DYNAMIC VOLTAGE RESTORER (DVR)

Symmetrical Components in Analysis of Switching Event and Fault Condition for Overcurrent Protection in Electrical Machines

Generator Protection GENERATOR CONTROL AND PROTECTION

INDUCTION MOTOR FAULT DIAGNOSTICS USING FUZZY SYSTEM

An Enhanced Symmetrical Fault Detection during Power Swing/Angular Instability using Park s Transformation

Simulation Programs for Load Shedding Studies: Expermintal Results

A Novel Islanding Detection Technique for Distributed Generation (DG) Units in Power System

International Journal of Scientific & Engineering Research, Volume 7, Issue 12, December-2016 ISSN Ribin MOHEMMED, Abdulkadir CAKIR

Voltage Sag Effects on the Process Continuity of a Refinery with Induction Motors Loads

Simulation of Thyristor Operated Induction Generator by Simulink, Psim and Plecs

MATHEMATICAL MODELING OF POWER TRANSFORMERS

Voltage Sag Effects on a Refinery with Induction Motors Loads

Unsymmetrical Fault Analysis & Protection Of The Existing Power System

Multimeter 500CVD21 RTU500 series

Control of Induction Motor Fed with Inverter Using Direct Torque Control - Space Vector Modulation Technique

Overcurrent and Overload Protection of AC Machines and Power Transformers

ISSN: Page 298

Wind Power Facility Technical Requirements CHANGE HISTORY

Wavelet Transform Based Islanding Characterization Method for Distributed Generation

Differential Protection with REF 542plus Feeder Terminal

BED INTERCONNECTION TECHNICAL REQUIREMENTS

Current Signature Analysis to Diagnose Incipient Faults in Wind Generator Systems

Simulation and Comparison of DVR and DSTATCOM Used For Voltage Sag Mitigation at Distribution Side

Protection of Electrical Networks. Christophe Prévé

Electrical Protection System Design and Operation

PJM Manual 07:: PJM Protection Standards Revision: 2 Effective Date: July 1, 2016

Vibration Analysis of Induction Motors with Unbalanced Loads

Fuseless Capacitor Bank Protection

Power System Protection Manual

The Occurrence of Faults in Permanent Magnet Synchronous Motor Drives and its Effects on the Power Supply Quality

Phoenix DX Clean Power (18 Pulse) AC Drive

RT- HIL Implementation of Hybrid Synchrophasor and GOOSE- based Passive Islanding Schemes

Differential Protection for Microgrids with Embedded Generations

Doãn Văn Đông, College of technology _ Danang University. 2. Local Techniques a. Passive Techniques

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 5: (August 2, 2013) Page 1 of 76

Instantaneous Overcurrent Relay

Volume I Issue VI 2012 September-2012 ISSN

ROTOR FAULTS DETECTION IN SQUIRREL-CAGE INDUCTION MOTORS BY CURRENT SIGNATURE ANALYSIS

Effects of the Short-Circuit Faults in the Stator Winding of Induction Motors and Fault Detection through the Magnetic Field Harmonics

889 Advanced Generator Protection Technical Note

Reducing the Effects of Short Circuit Faults on Sensitive Loads in Distribution Systems

SPEED CONTROL OF INDUCTION MOTOR WITHOUT SPEED SENSOR AT LOW SPEED OPERATIONS

Current-Based Diagnosis for Gear Tooth Breaks in Wind Turbine Gearboxes

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

Modified three phase Unified Power Quality Conditioner with capacitor midpoint topology

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 4: (June 10, 2013) Page 1 of 75

Distance Relay Response to Transformer Energization: Problems and Solutions

Swinburne Research Bank

Fault Detection of Induction Motor Using Fuzzy Logic

Impact Assessment Generator Form

AN ANN BASED FAULT DETECTION ON ALTERNATOR

Journal of Engineering Technology

Power System Stability. Course Notes PART-1

New Direct Torque Control of DFIG under Balanced and Unbalanced Grid Voltage

Induction Machine Test Case for the 34-Bus Test Feeder -Distribution Feeders Steady State and Dynamic Solutions

Protection of Extra High Voltage Transmission Line Using Distance Protection

Design and Simulation of DVR Used For Voltage Sag Mitigation at Distribution Side

ANALYSIS OF V/f CONTROL OF INDUCTION MOTOR USING CONVENTIONAL CONTROLLERS AND FUZZY LOGIC CONTROLLER

Protective Relaying for DER

A Low Torque Ripple PMSM Drive for EPS Applications

A Comparative Study of Wavelet Transform Technique & FFT in the Estimation of Power System Harmonics and Interharmonics

Volume 1, Number 1, 2015 Pages Jordan Journal of Electrical Engineering ISSN (Print): , ISSN (Online):

PAPER-II (Subjective)

ELECTRONIC CONTROL OF A.C. MOTORS

Grid Code Violation during Fault Triggered Islanding of Hybrid Micro-grid

Hysteresis Controller and Delta Modulator- Two Viable Schemes for Current Controlled Voltage Source Inverter

SHORT CIRCUIT ANALYSIS OF 220/132 KV SUBSTATION BY USING ETAP

Study and Simulation of Phasor Measurement Unit for Wide Area Measurement System

Modelling of Phasor Measurement Unit and Phasor Data Realisation with 2 Bus System

System Stability and Virtual Synchronous Machines. Why we need grid forming converters, and the metrological challenges of incentivising them.

Chapter -3 ANALYSIS OF HVDC SYSTEM MODEL. Basically the HVDC transmission consists in the basic case of two

System Protection and Control Subcommittee

Orbital GFI Inverter Series

SPEED CONTROL OF BRUSHLESS DC MOTOR USING FUZZY BASED CONTROLLERS

ISSN Vol.04,Issue.08, July-2016, Pages:

Analysis, Modeling and Simulation of Dynamic Voltage Restorer (DVR)for Compensation of Voltage for sag-swell Disturbances

A Novel Measurement Technique for Extra High Voltage Busbar Fault Detection

Embedded Generation Connection Application Form

AC : APPLICATIONS OF WAVELETS IN INDUCTION MACHINE FAULT DETECTION

DESIGN OF A MODE DECOUPLING FOR VOLTAGE CONTROL OF WIND-DRIVEN IG SYSTEM

A Robust Fuzzy Speed Control Applied to a Three-Phase Inverter Feeding a Three-Phase Induction Motor.

Position Control of AC Servomotor Using Internal Model Control Strategy

Keywords: Wavelet packet transform (WPT), Differential Protection, Inrush current, CT saturation.

Performance Analysis of Matrix Converter Fed Induction Motor with Different Switching Algorithms

Mitigation of voltage disturbances (Sag/Swell) utilizing dynamic voltage restorer (DVR)

Implementation and Evaluation a SIMULINK Model of a Distance Relay in MATLAB/SIMULINK

CHAPTER 4 CONTROL ALGORITHM FOR PROPOSED H-BRIDGE MULTILEVEL INVERTER

Fuzzy Logic based Fault Detection of PMSM Stator Winding Short under Load Fluctuation using Negative Sequence Analysis

SYNCHRONOUS MACHINES

Protection Basics Presented by John S. Levine, P.E. Levine Lectronics and Lectric, Inc GE Consumer & Industrial Multilin

Voltage Unbalance Effects on Induction Motor Performance

Eyenubo, O. J. & Otuagoma, S. O.

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Wind Aggregated Generating Facilities Technical Requirements

Transcription:

Proceedings of the World Congress on Engineering 013 Vol II,, July 3-5, 013, London, U.K. A New Fault Detection Tool for Single Phasing of a Three Phase Induction Motor S.H.Haggag, Ali M. El-Rifaie,and Hala M. Abdel Mageed Abstract-This paper introduces a new tool for fault detection in high voltage electrical networks; the new tool can be used by high speed digital relays to detect fault presence besides selecting the faulted phase(s). The suggested tool uses a new technique that squares both of the instantaneous voltage signal and its complement to produce a unity relation in normal operating conditions. The unity relation will remain undistorted as long as the power system is operating normally; however, the unity relation will change with any sudden change in the voltage signals due to any abnormal conditions. The suggested tool is being applied to detect the single phasing case for a three phase, high voltage induction motor. The simulation was done using Matlab simulink, where the simulation results showed great success of the suggested tool in detecting the single phasing case for all loading conditions. The new technique is then practically applied on a three phase induction motor, where the single phasing case is successfully detected. The practical results showed compliance with the simulink results in distinguishing the single phasing fault. Index Terms -Induction motors, Single Phasing, Digital relays I. INTRODUCTION A three-phase induction motor operating in the steadystate will continue to operate when a disturbance on the system causes the terminal voltages to become single phased. This condition is referred to as single phasing and will result in an operating condition that produces excess heating in the motor. Such a condition requires that the motor be provided with protection that will disconnect it from the system before the motor is permanently damaged. Single phasing in three phase induction motors can occur as a result of a fuse blowing or a protective device opening on one phase of the motor. Other possibilities include feeder or step-down transformer fuses blowing. Even though the motor will continue to operate in this condition, the motor will heat up very quickly, and it is essential that the motor be removed from service by the opening of a motor circuit breaker or some other types of protective devices [1,]. When one phase opens, the current to a motor in the two remaining phases theoretically increases to 1.73 (173%) times the normal current draw of the motor. The increase can be as much as times (00%) because of power factor changes. Where the motor has a high inertia load, the current can approach locked rotor values under singlephased conditions Manuscript received February 04, 013; revised February 1, 013 Ali Mohamed El-Rifaie is with the High Voltage Department at the National Institute for Standards, Giza, Egypt. P.O.136, Code 111 e-mail: alisystem11@ yahoo.com. Hala Mohamed Abd Elmageed is with the Electrical Quantities Department at the National Institute for Standards, Giza, Egypt. P.O.136, Code 111 e-mail: halaabdelmegeed@ yahoo.com. Three properly sized time-delay, dual-element fuses, and/or three properly sized overload devices will sense and respond to this overcurrent [3]. Methods for prediction and detection of motor faults are extensively documented in the research literature; many of these methods use stator currents and voltage signals in some form along with signature algorithms to determine or predict fault conditions in an induction motor [4]. Wavelet signal processing, and Fourier analysis are two techniques that can be used to discriminate the single phasing case from other voltage unbalance cases [5]. In this paper, a new fault detection tool that uses the square value of the instantaneous voltage signal and its complement to produce a unity relation in normal conditions is introduced. The suggested Cos-Sin tool [6] is being applied to detect the case of single phasing (open of one phase) in large induction motors where Matlab simulink is used to simulate a.3 KV, 50 Hp three phase induction motor, the simulation results showed the capability of the suggested tool to detect the case of single phasing, relying on the motor's voltage signal during single phasing. A practical application of the Cos-Sin tool is also shown using Lab View, where the Single phasing case is practically simulated and successfully detected. II. THE COS-SIN ALGORITHM The Cos-Sin algorithm is given as follows: the voltage signal at any instant for a given bus-bar is represented by V(t) where: V(t) Vmax cos(wt Ø) (1) On the other hand the complement of this signal could be obtained as V 0 (t) where: V (t) V sin(wt Ø) () 0 max By squaring, adding and normalizing the above two equations, a discrimination signal S CS (t) can then be introduced as follows: V ( t) V0 ( t) SCS(t) V V (t) S CS max max Cos²(wt Ø) Sin²(wt Ø) 1.0 (3) The value of S CS (t) is unity as long as there is no effective change in the value of V max and no extra-ordinary condition taking place. This unity relation is distorted as soon as a fault occurs. The peak voltage value is updated every one complete cycle (0 msec for f=50 Hz), where full synchronization is done between the actual voltage signal V(t) and its complement V 0 (t) by acquiring the utilized values at the same instant. Fig. 1 shows V(t) with some disturbances due to a fault at peak voltage, while its complement signal V 0 (t) appears to depend only on the pre-

V, Vo Proceedings of the World Congress on Engineering 013 Vol II,, July 3-5, 013, London, U.K. fault peak voltage. Fig. shows S CS (t) during normal operation, where the unity relation is kept steady. III. SIMULATION STUDY FOR SINGLE PHASING IN THREE PHASE INDUCTION MOTORS The case of one phase open in an induction motor is simulated using MATLAB simulink [7]. Figure 3 shows the simulink model for a three phase wound rotor induction motor. The parameters of the simulated wound motor are as given in Table I. An open of one phase case is simulated after 1.5 seconds of the motor operation. Figure 4 shows the deviation in the nominal operating current values at the instant of fault occurrence, the opened phase has a zero current, while the currents of other phases increased to an extent of double the normal operating current. Figure 5 shows the measured voltage signal at the instant of fault occurrence, the opened phase voltage decreased slightly in value while the other phases remained unchanged. The suggested Cos-Sin technique is applied and S CS (t) is obtained following equations 1 to 3. The simulation is done for three different load cases, no load, half load and full load where S CS (t) for all cases are shown in Figure 6. It appears clearly that the amount of maximum and minimum deviation from the unity relation of S CS (t) increases as the load increases from zero to maximum value. Table II, shows the deviation in the unity value of S CS (t) during single phasing of phase A for a time of 0. sec. From the shown values, it appears clearly that the new Cos-Sin tool can safely detect the case of single phasing (open of one phase) for high voltage, three phase induction motors TABLE I PARAMETERS OF SIMULATED MOTOR Parameter Value in SI units Unit FREQUENCY 60 HZ NOMINAL POWER 50 HP VOLTAGE (L-L) 300 V STATOR RESISTANCE 0.09 OHM STATOR INDUCTANCE 0.000605 H ROTOR RESISTANCE 0.0 OHM ROTOR INDUCTANCE 0.000605 H MUTUAL INDUCTANCE 0.0346 H INERTIA FACTOR 63.087 KG.M PAIRS OF POLES 4 600 400 V(t) Vo(t) 00 Fig. 3. Matlab simulink model for single phasing of a three phase wound rotor induction machine 0-00 -400-600 0 100 00 300 400 500 600 700 800 Sampling Time Fig. 1. Normal voltage signal and its complement during abnormal condition Fig. 4. Deviation of the three phase currents during single phasing at phase-a Phase-A Fig.. Discrimination signal during normal operation Fig. 5. Three phase voltages during single phasing at phase-a

Proceedings of the World Congress on Engineering 013 Vol II,, July 3-5, 013, London, U.K. IV. FAULT DETECTION CRITERION FOR SINGLE PHASING To avoid the errors that may occur in the unity relation due to any variation in the peak voltage during normal operation, and since the maximum permissible variation in the peak value of the simulated network's voltage is 5 %, a voltage detection threshold Ɛ" of a value 0.05 (0.05 ) is used; However, Ɛ will just act as a trigger that initiates the operation of the Cos-Sin tool obtainer to start its mission of detecting fault presence. This is done via calculating the deviation δ in S CS (t) in one complete cycle time starting from the instant of fault occurrence, and is given as follows: 1 1 n n i 1 S ( i CS )...(4) Where n: is the number of samples of one complete cycle of the system power frequency. One complete cycle time is used to avoid wrong triggering due to transients. TABLE II DEVIATION IN S CS (t) AT DIFFERENT LOAD VALUES OF THE FAULTED PHASE Load level δ-faulted phase No load 0.185 Half load 0.115 Full load 0.101 Fig. 6-C. S CS (t) of the opened phase at full load Start Read VA, VB, VC at motor terminals and IA, IB, IC Apply the Cos-Sin tool to obtain SCS(t) SCS(t)>1±Ɛ? No Calculate δ No δ Ɛ? Read IA, IB, IC Fig. 6-A. S CS(t) of the opened phase at no load. Declare Unbalance No I i = Zero? Declare Single Phasing Fault on Phase (i) END Fig.7. Flow chart of the proposed Cos-Sin tool for single Phasing detection in Three Phase Induction Motors Figure 7 shows the flow chart of the proposed technique for single phasing fault detection, where both the voltage and current signals are used to differentiate between voltage unbalance and single phasing. Fig. 6-B. S CS(t) of the opened phase at half load V. PRACTICAL SIMULATION FOR SINGLE PHASING The suggested tool was practically simulated to check its applicability for implementation in reality. All the network component were modelled where a 400 V power source linked to an auto transformer was used as a supply, a three phase low voltage induction motor that is loaded by a gear

Proceedings of the World Congress on Engineering 013 Vol II,, July 3-5, 013, London, U.K. box was connected to it and a set of both single and 3 phase circuit breakers were connected in series and inserted in between. On the other hand the proposed technique was programmed using the LabVIEW software [8] and all system signals were delivered to the DAQ via voltage and current transformers where they occupied no.6 analogue inputs. Tables III and IV offer the specifications of the data acquisition card and the parameters of the used motor respectively. Figure 8 presents the connection of the laboratory equipments where the motor phasing condition can be obtained using the single phase circuit breaker shown. Figure 9 represents the voltage of the opened phase besides its generated complementary signal while figure 10 represents the correspondent currents of the motor during single phasing occurrence respectively. The discrimination signal obtained is illustrated in figure 11. Table V. provides the deviation in the discrimination signal S CS (t) before and after the single phasing incident. Fig. 9. Opened phase voltage and its generated complementary. TABLE III DATA ACQUISITION DATA DAQ Specifications Series M Analogue I/Ps 3 SE/16 DI PC connection USB Analogue O/Ps 4 Sampling 1.5 MS/s Digital I/Os 48 Counter-Timers TABLE IV DATA OF USED MOTOR Frequency (HZ) 50 Voltage (V) 30/400 Δ/Υ Capacity (KW) 4 Current (A) 14.3-8. Cos φ 0.83 RPM 1440 IP 55 CTs PTs Fig.10. Motor 3 phases currents. Elec. Source Auto Transformer 1 phase CB DAQ. (Load) Motor 3 Phase CB Terminal Blocks Gear Box Lap. top Fig. 8. Laboratory model connection. Fig.11. S CS(t) before and after single phasing.

Proceedings of the World Congress on Engineering 013 Vol II,, July 3-5, 013, London, U.K. TABLE V DEVIATION "δ" DURING SINGLE PHASING INCIDENT AT NO LOAD Period covered δ during normal operation δ After single phasing Half Cycle 0.05 0.05 Full Cycle 0.04 0.193 The calculated value for δ during normal operation exceeded the threshold value used in simulation owing to the harmonic content in the voltage signal besides the error in detecting the peak value of the original voltage signal every one complete cycle time. That resulted in using another threshold value of Ɛ= 0.06 to avoid any wrong operation. The practical simulation results acquired from the laboratory model almost concurred with the MATLAB simulink simulation outcomes, they both showed the capability of the proposed Cos-Sin tool in capturing the case of single phasing of a motor by using the voltage signal on machine terminals. REFERENCES [1] W. H. Kersting, Causes and effects of unbalanced voltages serving an induction motor, IEEE Trans. Ind. Appl., vol. 37, no. 1, pp. 165 170, Jan./Feb. 001 [] On line protection systems for induction motors, I. C olak et al. Energy Conversion and Management 46 (005) 773 786 [3] Benbouzid M, Vieira M, Theys C. Induction motors fault detection and localization using stator current advanced signal processing techniques. IEEE Trans Power Electron 1999;14:14 [4] Thomson WT, Fenger M. Current signature analysis to detect induction motor faults. IEEE Ind Appl Mag 001;7:6 34. [5] Filippetti F, Franceschini G, Tassoni C, Vas P. Recent development of induction motor drives fault diagnosis using AI techniques. IEEE Trans Ind Electron 000;47:994 1004. [6] S.H.Haggag, Ali M.El-Rifaie, R. M. Sharkawy "A novel measurement technique for extra high voltage bus bar fault detection" EEEIC 01 pp 403-406 [7] Matlab Simulink,Matlab R 010b. [8] National Instruments, LabVIEW, 010. VI. CONCLUSION The paper introduced a new fault detection tool that can be safely used to detect the case of single phasing in three phase induction motors. The simulation results using Matlab simulink showed complete success of detecting the single phasing case for all load conditions. The laboratory results showed full success of applying the new Cos-Sin tool practically besides showing the capability of detecting the single phasing fault and differentiating between voltage unbalance case and single phasing one. The results of the two implemented simulations showed a large extent of compliance with each other and a great success in detecting the open of one phase case. The suggested tool is characterized by being simple, fast, accurate and executable within digital relaying schemes.