Bulletin 800R 30.5 mm Push Button Stations Hermetically Sealed for Division 2/Zone 2

Similar documents
Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below.

800T T2 H2 E E X X. a b c d e f g Right Left Right Left. d, e, f, g. c (cont'd) 1-, 2-, 3-, 4-Way Toggle Switches (Bul. 800T only)

M = Maintained S = Spring Return. Operator Only ➊ No Contacts M M 800T-00HX2KB6 M M 800T-24HR2KB6AX 800T-24HR17KB6AX Incandescent

1.3. Pushbuttons and Indicating Lights.

Table of Contents. 22mm Push Buttons. 30mm Metal Push Buttons. 22mm Plastic Enclosures, Control Boxes & Installation Instructions 30-35

Open Type Without Enclosure

AGUB Instrument and Meter Enclosures Explosionproof, Dust-Ignitionproof Furnished with aluminum body and solid or window cover.

Limit Switch Style Inductive Prox

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

REPLACING ACC7B WITH CAT2

GENERAL PURPOSE RELAYS

AC-Operated Latch Units PKLL11. Reset Input. DC-Operated Latch Units DC-PKLL10

Echotel Model 910 Ultrasonic Level Switch

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

Echotel Model 910 Ultrasonic Level Switch

T S 15KVA 1PH 240/480 Transformer

Flow Detection MDS Integral or Remote Housing FUNCTION TYPICAL USES. Microwave Doppler Switch Solids - Chute and Conveyor GHz Sender Receiver

Electro-Magnetic Flowmeters COPA-XE

Class 1 Division 2 Fluorescent Light - 2 Foot 3 Lamp - Corrosion Resistant Requirements

Instruction Manual. Model MLA & MLD Loop Powered Process Indicators IM 61A01A-01E-A. Model MLA (Analog) Model MLD (Digital)

Level Lance Model 5100

Open Type Without Enclosure

Process display RIA 261

BVP SERIES Brass Lighting for Marine and Hazardous Environments

General Specifications

Echotel Model 911/921 Ultrasonic Level Switches

Shrink temperature of 120 C. Rated for 600V, 90 C continuous use. T&B recommended up to 1kV. HS Series Specifications

Cast Iron Junction Boxes

DISCONNECT SWITCHES. UL Listed CSA Certified

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

G5LE. Ordering Information. PCB Relay. A Cubic, Single-pole 10-A Power Relay J MODEL NUMBER LEGEND G5LE PCB Relay G5LE

Loop Powered Indicator

FSK1VDRA 1G Al DPLX RCPT CVR

TGF2200 Micro Pulse Level Meter

Portable Hacksaws for Tough Duty

ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE)

GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS

OPTIWAVE 1010 Technical Datasheet

Echotel Trident 91S/92S Ultrasonic Level Switches

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

FAIRBANKS NIJHUIS 1590 SERIES SINGLE STAGE VERTICAL INLINE PUMP.

Local control stations for Zone 1 and Zone 21. Features. Description

Spring Return DuraDrive Proportional Actuator

Slim compact safety relay

Heat-Shrinkable Tubing

Level Measurement Continuous level measurement Radar transmitters

FLUORESCENT/AREA: NEC/CEC EXPLOSIONPROOF. Applications. Illustrated Features

Control Stations ø 22

AVP SERIES Aluminum Lighting for Hazardous and Severe Environments

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

21R14A Receiver 14 Control/1 Alarm/1 Safety relays 120 VAC Power Supply

Type Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage

Complete units: Selector switches ø 22mm

Areamaster Generation 2 HL LED Luminaire Floodlight for Hazardous Locations

KFS. Flap-type flow meter. Design and range of application

Shrink temperature of 120 C. High-impact, abrasion, corrosion and chemical resistance. Rated for 600V, 90 C continuous use

Description Cast Device Box, Height Inch; Width 2.81 Inch; Depth 2.69 Inch; Capacity 25 Cu Inch; 1 Gang; 2 Hub(S); Hub Location End;

Universal Voice Coil and 70 Volt Door Speaker V / V

Applications. Illustrated Features. Certifications and Compliances

PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL.

Portable Hacksaws for Tough Duty

SECTION 1 SOCKET COMPATIBLE AND FLANGE MOUNTED RELAYS 1 TO 30 AMPERES

COMMERCIAL AND INDUSTRIAL FITTINGS: CAST DEVICE BOXES. Applications

MODEL AT-10 ANALOG TRANSMITTER

Complete units: Push-buttons ø 22mm

Complete units: Mushroom heads ø 22mm

Fuzzy Temperature Controllers E5AF

Design and applications

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Compliant with European standards 1a/1c 6A Slim power relays

Baymaster LED Luminaire High Bay for Hazardous Locations

Series 80 In-Line Mounted Centrifugal Pumps

KRPA, KRP, KA, KR series

Flow Detection MDS Integral or Remote Housing. Installation and Operating Instructions

Steps for Selecting the Proper Transformer

HLC-1000 High-limit Humidity Control

Series 5 Die Cast Aluminum Conduit Outlet Bodies, Covers and Gaskets

NEMA Contactor and Starter Specifications

Bulletin 700-RTC Solid-State Timing Relay

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service

Baymaster HL LED Luminaire High Bay for Hazardous Locations

Temperature Controllers E5 J

onlinecomponents.com

PCR Polarization Cell Replacement. The Polarization Cell Replacement (PCR) Technical Literature COMMON APPLICATIONS

General-purpose Relay

200 Watt Passive Shunt Module

LUXTRAN Luminaires for Tunnel Applications

Bulletin 1497 Global Control Transformers

General-purpose Relay

Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1

D-subminiature Metal Shell and All Plastic Solder Cup and IDC T* Series

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

PRODUCT SPECIFICATION

OPERATION MANUAL FOR ALLIGATOR TUMBLE STIRRER* VP 710A

Technical Instructions Document No EA GQD October 25, OpenAir GQD Series

Mercmaster LED Low Profile Luminaires with Emergency Battery Backup Enclosed and Gasketed Fixtures

IP26 Series Current to Pneumatic Converter

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

Transcription:

30.5 mm Stations Hermetically Sealed for Division 2/Zone 2 10 Bulletin 800R Hazardous Location Stations Classes I and II Division 2/Zone 2 30.5 mm Mounting Hole Types4/13and4/4X/13 0 TABLE OF CONTENTS Description Page Description Page Specifications...10-107 800T Operators...10-6 800H Operators....10-60 Stations Complete Assembled, Metallic Enclosures....... 10-108 CompleteAssembled,Non-MetallicEnclosures...10-109 Custom Built Stations....10-110 Enclosures Only...10-110 Approximate Dimensions and Shipping Weights....10-111 10-106 AB Parts

30.5 mm Stations Hermetically Sealed for Division 2/Zone 2 Specifications ➊ Contact Ratings Dielectric Strength Electrical Design Life Cycles Vibration Shock Degree of Protection Mechanical Design Life Cycles s Selector Switches (Momentary, Non-Illuminated) (Momentary, Illuminated) (-Pull/Twist-to-Release) (Non-Illuminated) (Illuminated) ➊ Performance Data See page Important-2. Electrical Ratings Refer to the Contact Ratings tables below. 2200V for one minute, 1300V for one minute (Logic Reed) 1,000,000 at maximum rated load, 200,000 at maximum rated load (Logic Reed) Mechanical Ratings 10 2000 Hz 1.52mm displacement (peak-to-peak) Max./10 G Max. (except Logic Reed) 1/2 cycle sine wave for 11 milliseconds 25 G (contact fragility) and no damage at 100 G, 4/13; Watertight/Corrosion-Resistant IEC 529 IP66/65 10,000,000 min. 250,000 min. 250,000 min. 1,000,000 min. 200,000 min. 200,000 min. All other devices Contact Operation Logic Reed and Sealed Switch Contact Blocks: Single break magnetic Typical Operating Forces Operators without contact blocks Flush, Extended, Standard Mushroom, Jumbo Plastic Mushroom: 2 lbs max. Selector Switch: 3.6 in.-lbs maximum Spring Return Selector Switches 3.6 in.-lbs to stop 0.2 in.-lbs to return Illuminated s and -to-test s 5 lbs maximum 3-Position -Pull 8 lbs maximum push to in position or pull to center position (15 lbs maximum pull to out position) -Pull and -Pull/Twist 9 lbs maximum push or pull 30 in.-oz. maximum twist, 6 in.-oz. minimum return Logic Reed 1lbmaximum Contact Blocks Sealed Switch 3 lbs maximum at 0.205" plunger travel Stackable Sealed Switch 1lbmaximum Operating Temperature Range Storage Note: Operating temperatures below freezing are based on the absence of moisture and liquids. Contact your local Allen-Bradley sales office for use in lower temperature applications. Humidity Environment 40...+131 F ( 40...+55 C) 40...+185 F ( 40...+85 C) 50% at +104 F (+40 C) 1 Control Stations Bulletin 800R control stations are designed for Division 2/Zone 2 hazardous locations. They consist of Bulletin 800H () or Bulletin 800T (Type 4/13) operators with sealed contact blocks. Bulletin 800R units are available as factory assembled stations or as components for field assembly. Hazardous Locations Since the contacts are enclosed in a hermetically sealed chamber, the contact block is suitable for use in Class I and II, Division 2/Zone 2 Groups A, B, C, D, F and G hazardous locations and is listed by Underwriters Laboratories for this class of service. Complete stations as shown on page 10-108 can be used for Class I and II Division 2/ Zone 2 applications. The individual components shown in the 800T and 800H sections are also suitable for Class I and II Division 2/Zone 2 locations providing they are suitably mounted by the customer in an enclosure as required for the application and by applicable codes and laws. Class I Zone 2 protection method Ex nw IIc Temp. Code T3/T6, Demko 97.Y.122018 U applies to operators and contacts. Per National Electrical Code: Zone 2. InClassI, Zone 2 locations, all wiring methods permitted for Class I, Division 2, Class I, Division 1 or Division 2, and Class I, Zone 0 or Zone 1 locations, including requirements for sealing, shall be permitted. Note: Allen-Bradley Logic Reed contact blocks are also listed by Underwriters Laboratories for the Division 2/Zone 2 hazardous locations listed above.! CAUTION: The complete stations and individual components listed herein are not suitable for use in Class I and II Division 1 hazardous locations. For Class I and II Division 1 hazardous locations, order Bulletin 800H Type 7 & 9 stations and units. Sealed Switch Contact Ratings Maximum continuous current I th 5 A. Bulletin 800T and 800H units have control circuit ratings with sealed switch contact blocks as follows: Max. Opertnl. Utilization Category Rated Operational Currents Volts Ue IEC NEMA Volts Ue Make Break 120 600 3600 VA 360 VA AC 600 AC-15 B600 0 120 30 A 3A DC 300 DC-13 P300 Stackable Sealed Switch Contact Ratings Maximum continuous current I th 2.5 A. Bulletin 800T and 800H units have control circuit ratings with sealed switch contact blocks as follows: Logic Reed Contact Ratings Maximum DC: 30V, 0.06 A Maximum AC: 150V, 0.15 A Shouldonlybeusedwithresistiveloads. Approvals UL Listed File: E10314 Guide: NOIV CSA Certified: LR11924 IEC Compliance Demko 97.Y.122018 U 24 300 0 24 138 VA 5.0 A Max. Opertnl. Utilization Category Rated Operational Currents Volts Ue IEC NEMA Volts Ue Make Break AC 300 AC-15 C300 120 300 1800 VA 180 VA 0 120 15 A 1.5 A DC 150 DC-13 Q150 24 150 69 VA 0 24 2.5 A 10-107

30.5 mm Stations Hermetically Sealed for Division 2/Zone 2 Complete Assembled Stations, Metallic Enclosures Class I, Division 2/Zone 2 button operators for Class I, Division 2/Zone 2 are offered in Bulletin 800T page 10-4 and Bulletin 800H page 10-58. Surface Mount Cat. No. 800R-1TA Booted Operator Station Cat. No. 800R-1HA4T Bootless Operator Station Cat. No. 800R-1HA4TL 0 Operator Two s Two s Contact Symbol Red Type/Color Legend Marking Cast Aluminum Enclosures ➊ Surface Mount Stainless Steel Enclosures ➋ Booted Operator Station Bootless Operator Station Cat. No. Cat. No. Cat. No. 800R-1TB 800R-1HB4T 800R-1HB4TL 800R-1TA 800R-1HA4T 800R-1HA4TL No Legend 800R-1TX 800R-1HX4T 800R-1HX4TL 800R-2TA 800R-2HA4T 800R-2HA4TL No Legends 800R-2TX 800R-2HX4T 800R-2HX4TL No Legend 800R-2TAR 800R-2HAR4T 800R-2HAR4TL No Legends 800R-2TXR 800R-2HXR4T 800R-2HXR4TL 3-Position Selector Switch HAND OFF AUTO 800R-R3TA 800R-R3HA4TL No Legend 800R-R3TX 800R-R3HX4TL -Pull/Twist Red EMRG. 800R-1TAM 800R-1HAM4TL Two s 800R-2TAM 800R-2HAM4T 800R-2HAM4TL No Legends 800R-2TXM 800R-2HXM4T 800R-2HXM4TL ➊ Type 4/13 ➋ Approximate Dimensions Page 10-111 10-108 AB Parts

30.5 mm Stations Hermetically Sealed for Division 2/Zone 2 Complete Assembled Stations, Non-Metallic Enclosures Class I, Division 2/Zone 2 button Operators for Class I, Division 2/Zone 2 are offered in Bulletin 800T page 10-4 and Bulletin 800H page 10-58. Booted Operator Station Cat. No. 800R-1HA4R Bootless Operator Station Cat. No. 800R-1HA4RL Operator Two s Two s Contact Symbol Red Type/Color Legend Marking Rosite Glass Polyester Enclosures Booted Operator Station Bootless Operator Station Cat. No. Cat. No. 800R-1HB4R 800R-1HB4RL 800R-1HA4R 800R-1HA4RL No Legend 800R-1HX4R 800R-1HX4RL 800R-2HA4R 800R-2HA4RL No Legends 800R-2HX4R 800R-2HX4RL No Legend 800R-2HAR4R 800R-2HAR4RL No Legends 800R-2HXR4R 800R-2HXR4RL 1 3-Position Selector Switch HAND OFF AUTO 800R-R3HA4RL No Legend 800R-R3HX4RL -Pull/Twist Red EMERG. 800R-1HAM4RL Two s 800R-2HAM4R 800R-2HAM4RL No Legends 800R-2HXM4R 800R-2HXM4RL Approximate Dimensions Page 10-111 10-109

30.5 mm Stations Hermetically Sealed for Division 2/Zone 2 Custom Built Stations Description The tables on pages 10-108 and 10-109 list the most commonly used push button stations. Stations not listed in the tables may be ordered as custom built stations. Cat. No. The cat. no. used to identify custom built Bulletin 800R push button stations, which are built at the factory, will be cat. nos. listed for the enclosure only, except letter W will be substituted for the letter Z and with a station serial number. Ordering Information The following information is required when ordering custom built push button stations. 1. Cat. no. of enclosure. 2. Cat. no. of control units. 3. Legend plate cat. no. and/or marking for each unit. 4. Specify vertical or horizontal mounting. 5. Specify desired operator mounting sequence. Inclusion of a sketch is recommended. If no information is given, best judgement will be used. Enclosures Only 0 Die Cast Cat. No. 800R-2TZ Stainless Steel Cat. No. 800R-2HZ4 Rosite Glass Polyester Cat. No. 800R-2HZ4R Fiberglass Cat. No. 800H-2HZ4Y Die Cast (Type 4/13) Stainless Steel () Note: Enclosure and conduit dimensions are detailed on page 10-111, except for the fiberglass enclosures which are found on page 10-105. ➊ Number of units that can be mounted in enclosure. ➋ Extra deep. Accomodates two levels of stackable sealed switch contact blocks. Rosite Glass Polyester () Fiberglass ➋ (Type 4/4X/12/13) Units ➊ Cat. No. Cat. No. Cat. No. Cat. No. 1 800R-1TZ 800R-1HZ4 800R-1HZ4R 800H-1HZ4Y 2 800R-2TZ 800R-2HZ4 800R-2HZ4R 800H-2HZ4Y 3 800R-3TZ 800R-3HZ4 800R-3HZ4R 800H-3HZ4Y 4 800R-4TZ 800R-4HZ4 800R-4HZ4R 5 800R-5HZ4 800R-5HZ4R 6 800R-6TZ 800R-6HZ4 800R-6HZ4R 10-110 AB Parts

30.5 mm Stations Hermetically Sealed for Division 2/Zone 2 Approximate Dimensions and Shipping Weights Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Stainless Steel Watertight/Oiltight/ Corrosion-Resistant Enclosure 3 15 / 32 (88.1) 2 1 / 4 3 (57.2) 5 / 8 (92) Rosite Glass Polyester Watertight/Oiltight/ Corrosion-Resistant Enclosure 3 13 / 16 (96.9) 3 (76.2) 3 31 / 32 (100.8) 3 (76.2) Type 4/13 Watertight/Oiltight Cast Aluminum Enclosure 3 13 / 16 (96.9) 3 7 / 32 (81.8) A B 23 / 32 (28.6) Max. ➊ C A B 21 / 32 (16.7) Max. ➋ Dimension Number of Units 1 2 3 4 5 6 Stainless Steel A 5-5/32 (135) 7 (178) 8-27/32 (225) 10-11/16 (271) 12-17/32 (318) 14-3/8 (360) B 6-13/32 (163) 8-1/4 (210) 10-1/8 (257) 11-31/32 (304) 14-1/32 (359) 15-7/8 (403) Pipe Tap Size 3/4 1 Glass Polyester A 4-1/2 (114) 4-1/2 (114) 6-1/4 (159) 8 (203) 12-1/8 (308) 12-1/8 (308) B 7-1/32 (181) 7-1/32 (181) 8-23/32 (221) 10-21/32 (271) 14-7/8 (378) 14-7/8 (378) C 5-7/8 (149) 5-7/8 (149) 7-9/16 (192) 9-1/2 (241) 13-1/2 (343) 13-1/2 (343) Pipe Tap Size 3/4 1 Cast Aluminum Type 4/13 A 2-3/4 (69.8) 4-1/2 (114) 6-1/4 (159) 8 (203) 12-1/8 (308) B 4-3/16 (106) 5-7/8 (149) 7-9/16 (192) 9-1/2 (241) 13-1/2 (343) Conduit Opening 3/4" 14 N.P.T. 1" 11-1/2 N.P.T. 1 27 / 32 (46.8) 1 / 4 (6.4) Dia. Drill Mounting Instructions (for Panel Mounting) 2 1 / 4 (57.2) 9 / 16 (14.3) A B ➍ 1 27 / 32 (46.8) 1 13 / 64 Dia. (30.5) 21 / 32 Max. ➌ (16.7) Minimum Spacing 1 ➊ Selector switch is 1-5/32 (29.4) maximum; pilot light is 1-7/32 (31). ➋ Selector switch is 1-3/32 (27.8) maximum; pilot light is 1-5/32 (29.4) maximum. ➌ Selector switch is 1-7/32 (30.9) maximum; pilot light is 1-9/32 (32.5). ➍ Minimum vertical spacing dimension for jumbo legend plate is 2-15/32 (62.7). Operator Extension in Front of Panel ➎ Booted Flush and Extended Head Type 4/13 and Bootless Flush and Extended Head Type 4/13 Type 4/13 and 4/4X/13 Standard Knob Selector Switches 1 3 / 8 (34.9) Dia. 1 19 / 32 Dia. (40.5) 1 31 / 64 (37.3) Extended Head Only 3 / 16 (4.76) 1 31 / 64 Dia. (37.7) 1 31 / 64 (37.3) 23 / 32 (18.2) 1 7 / 32 (31) 15 / 32 (11.9) 1 9 / 32 (32.5) 1 7 / 32 (30.9) ➎ See pages 10-52 thru 10-55 for additional Type 4/13 outlines and pages 10-100 thru 10-103 for additional outlines. 10-111