SLIT LAMP BQ 900 Sophisticated microscopy

Similar documents
SLIT LAMP BI 900 Simplified operation high reliability

IMAGING MODULES IM 900 & IM 600 From the leader in slit lamp imaging

SLIT LAMPS Confidence that lasts

CONTACT LENSES Discover a different world

ioct Discover the next generation of efficiency enhancement

Look closer. See further.

Headline. SL 130 Slit Lamp. Subline. Maximum quality for optimum performance

Beautifully Crafted Slit Lamps

Beautifully Crafted Slit Lamps

Xcel 255 & 455 Slit Lamps

Lumenis Array LaserLink Pattern Scanning Laser Technology RETINA

you can We have an eye for detail. CF-1 HIGH RESOLUTION DIGITAL RETINAL CAMERA Camera Canon EOS 1Ds Mark III f7.1 1/800 ISO 320

KTP LASER. Photocoagulation System

CONNECTING VISIONS. TRC-50DX Digital Ready Retinal Camera

A DIVISION OF FORENSIC TECHNOLOGY SEE MORE. SOLVE MORE. CLASS-LEADING COMPARISON MICROSCOPES FOR FORENSIC INVESTIGATIONS

The TRC-NW8F Plus: As a multi-function retinal camera, the TRC- NW8F Plus captures color, red free, fluorescein

KL Series. Fiber optic illumination for stereo microscopy

Basic Principles of the Surgical Microscope. by Charles L. Crain

A DIVISION OF FORENSIC TECHNOLOGY. UCM pia The Universal Comparison Macroscope for Forensic Investigations

OLYMPUS Digital Cameras for Materials Science Applications: Get the Best out of Your Microscope

Marine Invertebrate Zoology Microscope Introduction

Contact lenses Goldmann/Diagnostics/Laser

OCULUS ImageCam 2. Slit lamp documentation. We focus on progress

INSTRUCTIONS FOR USE Slit Lamp BQ 900

SCHWIND AMARIS. We have redefined perfection for you

Integre Pro Scan combines pattern scanning and multi-color photocoagulation in our unique all-in-one laser/slit lamp design.

you can See more with fundus autofluorescence. CR-2 PLUS NON-MYDRIATIC DIGITAL RETINAL CAMERA

VISULAS Trion. Treatment flexibility to the power of three. Multicolor Photocoagulation Laser

Beautifully Crafted Slit Lamps.

A DIVISION OF FORENSIC TECHNOLOGY. UCM pia The Universal Comparison Macroscope for Forensic Investigations

Impressive Wide Field Image Quality with Small Pupil Size

What s Fundus photography s purpose? Why do we take them? Why do we do it? Why do we do it? Why do we do it? 11/3/2014. To document the retina

11/10/2015. Haag Streit Topcon Zeiss Kowa Add On Systems- OIS/Escalon and Others. The Original Design. Photo Slit lamp Systems. Who Makes Them?

Optical Coherence Tomography Retina Scan Duo

The First True Color Confocal Scanner

The First True Color Confocal Scanner on the Market

Catalogue No. 109, valid as of May The Full HD Video Colposcope

Camera Overview. Olympus Digital Cameras for Materials Science Applications: For Clear and Precise Image Analysis. Digital Cameras for Microscopy

TRC-NW400 Non-Mydriatic Retinal Camera

EnFocus Your Upgrade Path to High Performance Intrasurgical OCT

UCM: The Universal Comparison Macroscope for Forensic Investigations

ISO INTERNATIONAL STANDARD. Ophthalmic instruments Slit-lamp microscopes. Instruments ophtalmiques Microscopes avec lampe à fente

Keeler Catalogue. All Keeler products are designed to offer the ultimate in professional performance.

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

The First True-Color Wide-Field Confocal Scanner

INSTRUCTIONS FOR USE Slit lamp BM 900

Stereo Viewing Systems

INSTRUCTION FOR USE Photo slit lamp BX 900

Contact glasses & magnifying glasses Goldmann/Diagnostics/Laser

Family of Stereo Microscopes Quality microscopes for industry and life sciences

Improving outcomes LENSTAR LS 900. Biometry

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

INTERFEROMETER VI-direct

Better diagnosis and treatment all-in-one.

OCULUS Keratograph 4. Topographer. We focus on progress

OCT-A. Perimetry. Slit lamps. Retinal imaging OCOCTT. Microperimetry. Ultrasound. Lasers. HAAG-STREIT UK Product Portfolio

Ultimate DR flexibility

ADVANCED MEDICAL SYSTEMS PTE LTD Singapore Malaysia India Australia

Stereo Viewing Systems

HEINE QUALITY. :- HEINE Hand-held Ophthalmic Instruments

Zoom Stereo Microscope NYMCS-360 Instruction Manual

RADspeed Pro DIGITAL RADIOGRAPHIC SYSTEM. IBD-RADProAeroDR

CX-1 digital retinal camera mydriatic & non-mydriatic. Redefining true versatility.

MAGNIFIERS & TASK LAMPS FOR INDUSTRY. presented by

The pattern scanning multi-color photocoagulator that puts you in control

Instruments Commonly Used For Examination of the Eye

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

UCM: The Universal Comparison Macroscope for Forensic Investigations

HEINE Direct Ophthalmoscopes

Going beyond the surface of your retina

Variable microinspection system. system125

Sparkasse zu Lübeck (Sort code ) Acc.No

The ultimate in 4K laser projection

Improving the Collection Efficiency of Raman Scattering

Digital Slit Lamp Photography. A User s Primer

ML7520 ML7530 DIOPTER ADJUSTMENT RING BINOCULAR BODY, INCLINED 30. (a) Field Iris Control Lever. (c) Filter Slots EYEPIECES, KHW10X

TEM Cameras. Digital Cameras for Electron Microscopy

CLEMENT CLARKE OPHTHALMIC

Characterization Microscope Nikon LV150

INSTRUCTIONS FOR USE Slit lamp BI 900

Wide Angle Ophthalmoscope Instructions

The light microscope

Dornier Genesis. Urology Imaging System with FPD

Optical basics for machine vision systems. Lars Fermum Chief instructor STEMMER IMAGING GmbH

EXTERNAL LIGHT SOURCES FOR STEREOMICROSCOPES

OCULUS Easygraph. So Small and Yet a Topographer. Small, but Efficient As a Big One. All Important Parameters at a Glance

pco.edge 4.2 LT 0.8 electrons 2048 x 2048 pixel 40 fps up to :1 up to 82 % pco. low noise high resolution high speed high dynamic range

DIGITAL IMAGING NON-MYDRIATIC FUNDUS CAMERA NM-1000

C501-E029C. RADspeed. GENERAL RADIOGRAPHIC SYSTEM Automatic

Veraviewepocs 2D High Speed Panoramic X-Ray Crystal Clear Images with Reduced Radiation

BA310POL ADVANCED POLARIZATION MICROSCOPE

Kinder products for your most precious patients

Green Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500 US EDITION

Types of lenses. Shown below are various types of lenses, both converging and diverging.

WF WF Tool Milling Machines. Milling Machines for Die Making with digital position indicator.

Optical Sensor Systems from Carl Zeiss CORONA PLUS. Tuned by Carl Zeiss. The next generation in the compact class

ddr Compact Series Setting a new benchmark in digital radiography.

you can Portable DR with High Sensitivity. Less is more. CXDI-501C DIGITAL RADIOGRAPHY SYSTEM

GYN / US. VITOM A Unique Visualization System for Vaginal Hysterectomy in the Operating Room

Luminos RF Classic. Where value meets performance.

Transcription:

SLIT LAMP BQ 900 Sophisticated microscopy Tradition and Innovation Since 1858, visionary thinking and a fascination with technology have guided us to develop innovative products of outstanding reliability: Anticipating trends to improve the quality of life.

THE VERSATILE SLIT LAMP BQ 900 Sophisticated microscopy, outstanding performance Since its introduction in 1958, the famous Goldmann slit lamp BM 900 enjoys remarkable popularity amongst our customers because of its excellent optics and the impressive longevity. As a result, there are well over 100 000 of these original Haag-Streit slit lamps in daily use including many from the first years of manufacturing. Further innovations have followed to cover more advanced needs in slit lamp examination including the unique stereo variator, a wider range of magnifications and innovative imaging solutions. The basic goal of each Haag-Streit slit lamp development however has always been the same: to provide a slit lamp with excellent optics, optimum illumination and perfect mechanics. Following this tradition of slit lamp innovation, the BQ 900 LED was introduced in 2010 as the first LED slit lamp in the world. While the LED illumination allows brighter and more homogeneous illumination, the BQ 900 offers many other advantages including excellent optics, versatility and ease of operation. Therefore, it has become the standard slit lamp for those requiring advanced slit lamp microscopy. 02

Slit lamp BQ 900 1. LED illumination head 2. Eyepiece with double cross hair reticule 3. Switch for beam splitter 4. Diffusor 5. Pivoting background illumination 6. Imaging Module IM 900 7. Release bar 8. Illumination control 1 2 3 4 5 6 7 8 04

VERSATILE OPTIONS Wide range of accessories APPLANATION TONOMETER AT 900 The original Goldmann tonometer Because it is fast and reproducible, Goldmann applanation tonometry has been the gold standard in tonometry for many decades. It is based on the Goldmann principle tried and tested during more than 50 years of usage with millions of patients. Furthermore, thanks to the high precision of manufacturing at Haag- Streit the Goldmann applanation tonometer offers reliable performance during many years without the need for manufacturer maintenance. ZOOM OBJECTIVE A view with no limits APPLANATION TONOMETER AT 900 AND AT 900 D With the zoom objective, the magnification can be continuously changed from 6 up to 40x. Reference points are set at magnifications 10, 16 and 25 x to allow easy orientation. The zoom objective offers excellent diagnostic capabilities especially when used in conjunction with the video function. Any existing BQ 900 can be modified from a standard model to a BQ 900-Zoom. INCLINED EYEPIECE ADAPTOR Ergonomic and fatigue-free working With the inclined eyepiece adaptor, the view into the microscope is inclined at 20 degrees to the horizontal. Consequently, the examiner is able to maintain his head in a fatigue-free position. ZOOM-OBJECTIVE INCLINED EYEPIECE ADAPTOR 06

STEREO VARIATOR Enhanced view on fundus Unique to the BQ 900, the stereo variator reduces the angle of stereoscopic observation from 13 to 4.5. This facilitates the stereoscopic examination of the fundus, peripheral parts of the retina and the vitreous, even under unfavourable conditions such as high myopia and small pupils. The reduction of the angle enlarges the stereoscopic field of view under the described conditions, maintaining depth information in the stereoscopic observation. STEREO VARIATOR BEAM SPLITTER Connection to a wide range of accessories The beam splitter diverts a portion of the light to secondary attachments such as the second observer tube, video or digital cameras. Beam Splitters are available in different versions. The beam splitter for cameras diverts 70% of the light to the secondary attachment, the one for co-observation under equal conditions diverts only 50% of the light. Video or digital cameras can be connected to the beam splitter with a range of C-mount adapters, which offer different focus length for variable sensor sizes. There are also two versions of second observer tubes available: One short version for co-observing in sitting and a long version for co-observing in upright position. BEAM SPLITTER CONTRAST ENHANCING FILTER Fluorescence enhancement This yellow barrier filter provides additional contrast to fluorescein images. It can be mounted permanently on the slit lamp and easily inserted or removed as required. CONTRAST ENHANCING FILTER 07

Excellent optics The quality of the optical system determines the results of whatever application a slit lamp is used for. The BQ 900 is equipped with a elaborated optical system, manufactured for highest quality requirements. The result is a superb view, allowing accurate diagnostics, safe patient treatment and stunning imaging results. Optimum illumination The new LED illumination systems on our slit lamps deliver our sharpest, brightest and most homogeneous slit ever. The light spectrum was specially designed for Haag-Streit to meet the highest quality standards and to achieve results that are even superior to those delivered by tungsten light. This ensures optimal diagnostic details from the cornea to the retina. Perfect mechanics Since its foundation more than 150 years ago, Haag-Streit has stood for highprecision mechanics. This experience, combined with outstanding Swiss engineering and the use of high grade materials, ensures perfect mechanics in the BQ 900, which can last for decades. 03

FROM THE LEADER IN SLIT LAMP IMAGING Imaging Module IM 900 Intuitive imaging best results The Imaging Module IM 900 is a fully integrated compact imaging solution for the BQ 900 slit lamp. It is equipped with an ultra-sensitive camera which produces images of exceptional quality even under difficult light conditions. Designed for optimal user friendliness it provides you with features which make slit lamp imaging more convenient than ever before. Ideal workflow no distraction The control panel allows you to operate both the camera and the slit lamp illumination. Located in front of the joystick of the slit lamp, it can be used blindly while you are focused on your patient. The release bar is at your finger tip! The compact and modern design conforms to the design of the slit lamp. Thus the Imaging Module comes as a component of the whole system, thereby supporting an ideal examination workflow. CONTROL PANEL Simple image capturing Our fast and accurate automatic exposure control ensures correct illumination of the image while you are concentrating on your examination. Thanks to the History Trigger function, you do not need to worry about a patient blinking or moving when you take an image. The History Trigger does not just capture a single image, but records the last few seconds in real time and lets you select the perfect image HISTORY TRIGGER Intuitive software EyeSuite Imaging is a straightforward imaging software supporting the Haag-Streit imaging solutions. Easy image capture, efficient image editing and a well-structured patient management system make the software a perfect team player for daily practice. EyeSuite makes your slit lamp networkable both with other Haag-Streit devices and your practice network. It does not require any proprietary third-party software to provide connectivity. EYESUITE

CONNECTIVITY IS KEY EyeSuite Platform Flexible interfaces for easy integration into your network The EyeSuite software is designed for optimal patient flow in busy practices. Supporting the Haag-Streit imaging solutions, the software makes the BQ 900 networkable both with other Haag-Streit devices and your practice network. EyeSuite does not require any proprietary third-party software to provide connectivity. Furthermore, the EyeSuite Script Language or standardized interfaces, such as GDT or DICOM, connect easily to almost any electronic medical record (EMR) system. Patient orders can be received from the EMR system and the captured images are then automatically returned to it. If the BQ 900 is connected to an EyeSuite server, all the images taken can be accessed remotely from any number of viewing stations connected to the same database. 08

Technical specifications BQ 900 Illumination Light-source LED for examination (slit and background illumination) Slit width Slit length Illumination field diameter Slit image rotatability ± 90 Swiveling of the slit illumination to the microscope axis Filters Microscope Ocular magnification 12.5 Stereo angle Range of adjusting eye-pieces Pupil distance 0 14 mm continuous 1 14 mm continuous and fixed apertures ø 8 / 5 / 3 / 2 / 1 / 0.2 mm Horizontal ± 90, vertical 0 20 Blue, red-free (green), grey (10 %) and optional yellow 13 (convergent optics) +7 to -7 diopters 52 78 mm Magnification changer 6.3 / 10 / 16 / 25 / 40 Object field ø in mm 32.0 / 20.0 / 12.7 / 8.0 / 5.1 Instrument base Operation Single handed 3-dimensional operation of the control lever Measures (W x L x H) Spatial adjustment of the instrument base 100 mm (length), 100 mm (side), 30 mm (height) 312 mm x 305 mm x 676 mm IM 900 Camera Beam Beam path right Sensor size 1 / 1.2" Pixel size 5.86 μm Resolution 1936 x 1216 Dynamic range (sensor) 73 db Quantum efficiency at 525 nm 76 % Frame rate (frames per second) 30 Interface USB 3.0 Software EyeSuite Imaging Patient Manager, Capture Module, Image Viewer EMR Interfaces EyeSuite Script Language, DICOM (SCU), GDT AT 900 Measuring force Installation Measurement range Generated by leverage weight AT 900 model BQ, assembly on the microscope arm. 0 80 mm Hg 09

HS-Art.No. 1511.7200699.02060 Members of HAAG-STREIT Group HAAG-STREIT Holding AG www.haag-streit-holding.com HAAG-STREIT Deutschland GmbH www.haag-streit.de HAAG-STREIT AG www.haag-streit.com IPRO GmbH www.ipro.com SPECTROS AG www.spectros.ch CLEMENT CLARKE Ltd. www.clement-clarke.com HAAG-STREIT Medtech AG www.haag-streit-medtech.com HAAG-STREIT UK www.haag-streit-uk.com HAAG-STREIT France EURL www.haag-streit.fr John Weiss Ltd. www.johnweiss.com HAAG-STREIT Far East www.haag-streit-fareast.com HAAG-STREIT USA www.haag-streit-usa.com HAAG-STREIT AG Gartenstadtstrasse 10 3098 Koeniz Switzerland Phone +41 31 978 01 11 Fax +41 31 978 02 82 info@haag-streit.com www.haag-streit.com HAAG-STREIT Surgical GmbH www.haag-streit-surgical.com Möller-Wedel GmbH & Co KG www.moeller-wedel.com Möller-Wedel Optical GmbH www.moeller-wedel-optical.com Reliance Medical Inc. www.haag-streit-usa.com Asetronics AG www.asetronics.ch ComLab AG www.comlab.ch HAAG-STREIT AG, 3098 Koeniz, Switzerland 6. Edition/2015-10